Mechanical Permit
Permit No: 201710637
Issue Date: 12/12/2017
Expiration Date: 1211212018
Permission is given to:
Contractor: GTS & Construction, Inc* Owner: N/A
r
To perform the following work:
Class of Work: New Construction Valuation: $0
Sq Ft: 10,678.00
Job Description: all new mec** 2 STY SLAB, 5 BDRM, 9 1/2 BA, KITCHEN, DINE, GREAT, MEDIA, SHOE,
PRAYER, STUDY,t4 CAR GAR, HEARTH, COV PORCHES, CABANA
Project -Number: '201704449
At the following location:
Subdivision/Lot/Block: CHENAL VALLEY, L17&18, B96
Address: 80 HALLEN Ct
To be used as (occupancy): One & Two Family Residential
This permit is issued on the express condition that the above work shall conform in al respects to.the statements certified
to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building,
electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkansas.
I or we further agree to abide by the applicable conditions as printed on the permit card. I or we further certify that we have
read and understand the requirements of this permit and that all statements made by us in securing this permit are true
and complete to the best of our knowledge.
Permit Fees:
Data Processing $4.00
Mechanical Permit Fees $880.94
Total: $884.94
Licensed tractor or. Owner ~
Issued by: TSTEELE For: Charles G. Givens
Building Official
To schedule Mechanical inspections call: 501-918-5292 or 501-918-5282 c : tC
City of Little Rock '
U
'?yi ysyE
CITY OF LITTLE ROCK
DEPARTMENT OF PLANNING 8 DEVELOPMENT APPLICATION FOR:
BUILDING CODES DIVISION
723 WEST MARKHAM, 2ND FL MECHANICAL (HVACR) PERMIT
LITTLE ROCK, AR 72201
PHONE (501) 918-5282 OR (501) 918�292_
FAX: (501) 371-4546
OFF/CIAI :' 10637
PERMIT No-201 J
DATE ISSUED
ISSUED BY
INSPECTIONS
APPLICANT (Please Check)
WILL CALL ❑ ROUGH
❑SLAB ❑ FINAL
❑OTHER
INSPECTOR'S COMMENTS
PROJECTADDRES5: l cp —' PROJECTNO.:
(Same as Building Permit No.)
LEGAL DESCRIPTION: LOT_BLOCK SUBDIVISION
TELEPHONE:
OWNERITENANT
ADDRESS: FAX: r
r ` LICENSE NO.: '
CONTRACTOR: r V
ADDRE55/� TELEPHONEIFAi:[,�
CLASS OF WORK: EW ❑ADDITION ❑REPLACEMENT ❑ ALTERATION ❑OUT OF CITY
PROPOSED USE (OCCUPANCY): ❑COMMERCIAL RESIDENTIAL ❑ MODULARJMOBILE HOME ❑BOILER'
:
Q �� -
SQUARE FEETVALUATION:
HeatinglAirt'llechanical Permit Fees:
A. New one and two-family DWELLING Construction - $.0825/sgft (INCLUDES ROUGH & FINAL IN
OTHER CCUPANCIES
met[ rtial— healing, venlilatian, ductwork, air conditioning, i3oilers', and refrigerahan
8. Replacements• repairs, allerations and additions and new co
systems shall be as follows.
$31.00 for the first $500.00 up to $1,000 plus $5.16 for each additianal thousand a fraction thereof to and including 5500,00 - .
• $2.569.85 for the first $500.00a plus $4.10 for each add ltlanal thousand or fraction thereof, to and including $1,000,000.
• $4.619.36 for the first S1,000.000 plus $3.09 for each additional thousand arfractlori thereof
THESE PRICES INCLUDE ONLY ONE INSPECTION: ADDITIONAL INSPECTIONS ARE $20.50 EACH:
Minimum fee for any permit shall be S31.00. Additional fee for Data Processing: $4.00 Tres+ ntial) $6.00 (comm.)
NO.Of Air -Conditioning Units: - . — Du�afk` Yes ❑ Np
NQ Of Heating Unils:� — (ALL AUCTVi0 j<REQUIRESA ROUGH INSPECTION)
Commercial Ventilation System .
Commercial Refrigeration Split System . Na• Of Inspectlans
CH VZK ONE OR MORE BELOW:
ctricOGas Fred ❑Splil System❑Package Unit (Water Source ❑Condenser Coil ❑Condenser ❑ Evaporative Coil 00ther (Explain)
NOTE: BOILER PERMITS ARE ISSUED WITH PROOF OF SPECIAL BOILER LICENSE
Penalties (Working without a permit): Where work for which a permit is required by the 2010 Arkansas Mechanical payment of such triple fee shall not relieve any
anical Code in the execution of the work nor from any penalties prescribed herein and
person from fully complying with the requirements of the 2010 Arkansas Mech
no additional permits shall be granted until all fees have been paid. c ` I' " ' • " ' '
NOTICE: SEPARATE PERMITS ARE REQUIREPDIIFOR cation IEt ECTRICAand tL,AGAS,
ny PLUMBation from N mation ANDDHVaIACdR WORK.
I hereby certify that the data submitted an or
with
Unless approved by the Building Official will render this permit null and void.
r'o&ti Ins
SIGNATURE OF CONTRACTOR, OWNER OR AGENT
OATS
' .:
RECEIVED 12/12/2017 15:57 5013714546 CITY OF LR
2017-12-12 15:08 GTSyINC 5016231808 >> 5013714546 P 1/1
Summary
Project Job:
J Summary Sato: Nov 26, 2016
TR1xp►f' Entire House By:
GTS Inc
P.O. Box 2624. Hot Sollt s. Alt 71014 rot ane:501.700.3032 Fax. 501.020.180E Wbb; w.w.g 7HCe m�r,(gn
Project
For Hallen Court
Little Rock, AR
Notes:
Design Information
Weather:
Winter Design Conditions
Outside db 21 IF
Inside db 68 IF
Design TO 47 IF
Heating Summary
Structure 93023 Btuh
Duds 56434 Stub
Central vent (0 cfm) 0 Stuh
Humidification 0 Btuh
Piping - 0 Btuh
Equipment load 149457 Btuh
Infiltration
Little Rock AFB, AR, US
Method
Simplified
Construction quality
Semi -tight
Fireplaces
1 (Average)
Heating
Cooling
Volume�(P)
9508
9500887
Airchangesthour
0.26
0.13
Equiv. AVF (den)
416
206
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Healing input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
80 AFUE
0 Stub
U Stub
IF
4588 Cfm
0.031 dmlBtuh
0 In H2O
Summer Design Conditions
Outside db
101 IF
inside db
75 IF
Design TD
26 OF
Daily range
M
Relative humidity
50 %
Moisture difference
57 grAb
Sensible Cooling Equipment Load Sizing
Structure
70870 Stub
Ducts
36522 Stub
Central vent (0 cfm)
0 Stub
Blower
0 Stub
Use manufacturers data
n
Ratelswing multiplier
1.06
Equipment sensible load
113836 Stub
Latent Cooling Equipment Load Sizing
Structure
9929 Stub
Duds
12636 Btuh
Central vent (0 cfm)
0 Stub
Equipment latent load
22564 Stub
Equipment total load
136401 Btuh
Req. total Capacity at 0.70 SHR
13.6 ton
Cooling Equipment Summary
Make
Trade
Cond
Coil
AHRI ref
Efficiency
0 SEER
Senslble Cooling
0 Btuh
Latent cooling
0 Btuh
Total cooling
0 Bluh
Actual air flow
4588 dm
Air flow factor
0,042 cfm/Btuh
Static pressure
0 in H2O
Load senslble heat rati6
0.83
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightSOft RI911$u11e0Unuerso1201515.0.23 ASt100e00
AI.Ck...gebroboMDoam"i%TranoWlko%Hotten Court.ru0 Colo- MJO Front Door faces: N
2017-May-1010:20:13