HomeMy WebLinkAboutZ-10352 Site Plan - REVISED 072026GATE TOALLEY WITHKNOX BOXRECONFIGUREDPARKINGSUPERVISEDANIMALRELIEFFENCED AREAABANDONEDDRIVEPROPOSEDDRIVE24.00'9.00'18.00'
5.00'
5.00'5.00'MONUMENTSIGNAGE84PROPOSED 5'SIDEWALK5.00'PROPOSED 5'SIDEWALKC1.01NORTHPROJECT TITLE:PROJECT NO:SHEET NO:SHEET TITLE:
DEVELOPMENT CONSULTANTS INCORPORATED
20267-13-20261" = 10'DATE:SCALE:COPYRIGHT:REVISIONS
2200 N. RODNEY PARHAM ROAD SUITE 220LITTLE ROCK, AR 72212501-221-7880G:\201X\XX-XX\XXXXXX\XX-XXX XXXXXX.DWG
SITE PLAN
W MARKHAM VETERINARY CLINIC
LITTLE ROCK, ARKANSASXX-XXXINCORPORATEDCONSULTANTSDEVELOPMENTGENERAL NOTES:1.CONTRACTOR SHALL NOTIFY PROJECT ENGINEER PRIOR TO BEGINNING WORK.2.CONTRACTOR IS RESPONSIBLE FOR APPLICATION, PAYMENT, AND ACQUISITION OF ALL PERMITSNECESSARY FOR THE CONSTRUCTION ACTIVITIES RELATED TO THIS PROJECT.3.CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES IN ACCORDANCE WITH THE ARKANSASUNDERGROUND FACILITIES DAMAGE PREVENTION ACT. THIS LAW REQUIRES THAT THE CONTRACTORMAKE A TELEPHONE CALL TO THE ARKANSAS ONE-CALL SYSTEM AT 1-800-482-8898 AT LEAST FOURWORKING DAYS PRIOR TO EXCAVATION TO ENSURE THAT ANY EXISTING UTILITIES CAN BE LOCATED.4.THE LOCATIONS OF EXISTING UTILITIES AS SHOWN HEREON ARE BASED ON ABOVEGROUND STRUCTURES,MARKINGS AND RECORD DOCUMENTS. LOCATIONS OF UNDERGROUND UTILITIES MAY VARYSIGNIFICANTLY FROM LOCATIONS SHOWN HEREON. ADDITIONAL BURIED UTILITIES/STRUCTURES MAY BEENCOUNTERED. THE CONTRACTOR SHALL MARK LOCATE & MARK UTILITY LINES BEFORE CONSTRUCTIONAND UNCOVER AS NEEDED.5.EXISTING UTILITIES TO REMAIN SHALL BE PROTECTED. CONTRACTOR SHALL BEAR ALL RESPONSIBILITYAND COST OF REPAIR OR REPLACEMENT OF EXISTING UTILITIES, DAMAGED OR INTERRUPTED AS ARESULT OF THIS CONSTRUCTION PROJECT.6.CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER AND THE OWNER OF ANY DAMAGED ORINTERRUPTED UTILITIES IMMEDIATELY.7.CONTRACTOR IS RESPONSIBLE FOR RETURNING ALL EXISTING SITE CONDITIONS DISTURBED BYCONSTRUCTION ACTIVITIES BACK TO EXISTING OR BETTER CONDITION.8.ALL SEWER LINES AND APPURTENANCES SHALL BE INSTALLED IN ACCORDANCE WITH THE LITTLE ROCKWATER RECLAMATION AUTHORITY STANDARD PIPELINE MATERIALS AND CONSTRUCTIONSPECIFICATIONS, LATEST EDITION.9.ALL WATER LINES AND APPURTENANCES SHALL BE INSTALLED IN ACCORDANCE WITH CENTRALARKANSAS WATER STANDARD PIPELINE MATERIALS AND CONSTRUCTION SPECIFICATIONS, LATESTEDITION.10.EXISTING UTILITIES TO REMAIN ARE TO BE PROTECT AND ADJUSTED TO MATCH PROPOSED GRADE ASNEEDED11.ALL AREAS WITHIN THE PARKING LOT ARE TO RECEIVE A GRAVEL BASE TO PROVIDE EROSION CONTROL IFWORK IS NOT PROGRESSING IN AN ORDERLY MANNER. A RATE OF 135 TONS/ACRE IS TO BE APPLIEDWITHIN TWO WEEKS OF FINAL GRADING.12.ALL AREAS NOT WITHIN THE PARKING LOT ARE TO RECEIVE LOOSE STRAW TO PROVIDE EROSIONCONTROL IF WORK IS NOT PROGRESSING IN AN ORDERLY MANNER. A RATE OF 1.5 TONS/ACRE IS TO BEAPPLIED WITHIN TWO WEEKS OF FINAL GRADING.13.WHEN NEW INLETS ARE CONSTRUCTED, INLET PROTECTION MEASURES ARE TO BE INSTALLED.14.CONTRACTOR WILL CONTROL AND PREVENT OFF-SITE TRACKING OF CONSTRUCTION RUNOFF ANDSEDIMENT TO ADJACENT PROPERTY AND PUBLIC ROADS.15.CONTRACTOR IS TO INSTALL INLET PROTECTION & GENERAL EROSION CONTROL MEASURES TO PROTECTEXISTING STORM DRAINAGE SYSTEMS.16.CONTRACTOR TO CONFORM TO ALL CONSTRUCTION STORM WATER AND EROSION CONTROL PERMITTINGREQUIREMENTS BY "EPA PHASE II STORM WATER REGULATIONS" AS ADMINISTERED BY THE ARKANSASDEPARTMENT OF ENVIRONMENTAL QUALITY (ADEQ). WHERE PERMITTING IS REQUIRED, A COPY OF THENOTICE OF INTENT SHALL BE PROVIDED TO THE LOCAL MUNICIPAL AUTHORITY.17.CONTRACTOR TO CONSTRUCT ALL ACCESS RAMPS AND PAVING TO CITY OF LITTLE ROCK AND/OR ADASTANDARDS. VERIFY.18.TREES TO REMAIN ARE TO BE PROTECTED FROM DAMAGE DURING CONSTRUCTION.19.ELECTRICAL & LIGHTING INFORMATION SHOWN FOR COORDINATION PURPOSES ONLY. SEE MEP SHEETSFOR DETAILS AND SPECIFICATIONS.20.CONTRACTOR SHALL NOTIFY ENGINEER OF ANY CONSTRUCTION CONFLICTS THAT BECOME APPARENT &REVIEW INSTRUCTIONS AND/OR PLAN REVISIONS PRIOR TO MAKING ANY CHANGES.SCALE: 1" = 10'20'10'05'10'DRAINAGE OUTLETEXISTING BURIED ELECTRICEXISTING STORM PIPEPOWER POLE W/ LIGHTWATER METERFIRE HYDRANTPOWER POLEWATER VALVEEXISTING LIGHT POLEEXISTING GASEXISTING OVERHEAD ELECTRICEXISTING WATEREXISTING UNDERGROUND FIBEREXISTING EASEMENTINTERIOR CONTOURINDEX CONTOURSEWER MANHOLEEXISTING FENCEEXISTING TREEEXISTING R.O.W.EXISTING CURB INLETPROPERTY LINESIGNTELEPHONE PEDESTALEXISTING CENTER LINEEXISTING SANITARY SEWERADA CROSSWALKPROPOSED PRIVACY FENCEPROPOSED CURB & GUTTERADA SIGNAGEPROPOSED PARKING STRIPINGASPHALT PAVINGCONCRETE PAVINGLANDSCAPE AREAVETERINARIAN (MEDICAL) CLINIC : 2 DOCTOR CAPACITY6 PARKING SPACES / DOCTOR | 12 PARKING SPOTS ALLOWED | 12 PARKING SPOTS PROVIDED