HomeMy WebLinkAboutPC Minutes 091526September 10, 2026
ITEM NO.: 10 FILE NO.: Z-10352
NAME: Daisy Street Holdings (Animal Clinic) – Conditional Use Permit
LOCATION: 5508-5514 W. Markham Street
DEVELOPER:
Austin Paul (Agent)
2200 N. Rodney Parham Road, Suite 200
Little Rock, AR 72212
OWNER/AUTHORIZED AGENT:
Daisy Street Holdings, LLC (Owner)
1012 Beechwood Street
Little Rock, AR 72205
SURVEYOR/ENGINEER:
White-Daters, Incorporated
24 Rahling Circle
Little Rock, AR 72223
AREA: 0.63 acre NUMBER OF LOTS: 3 FT. NEW STREET: 0
WARD: 3
CURRENT ZONING: O-3
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant requests a conditional use permit to allow for the development of a
specialty outpatient veterinary clinic. The clinic will not contain overnight boarding,
outdoor kennels, or other high-intensity animal care activities. Subject property is
located within the Midtown Design Overlay District (DOD).
B. EXISTING CONDITIONS:
The proposed site is located on the north side of the W. Markham Street corridor
(Minor Arterial) and contains existing buildings previously utilized for office or
commercial uses within the O-3 zoning district. Surrounding properties contain a
September 10, 2026
ITEM NO.: 10 (Cont.) FILE NO.: Z-10352
2
mixture of zoning and uses. War Memorial Park, St. Vincent Medical Center and
Arkansas State Hospital are located to the south of proposed site.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS (PLANNING): No comments.
ENGINEERING COMMENTS (PUBLIC WORKS):
1. W. Markham Street is classified on the Master Street Plan as a minor arterial
with special design standard. A dedication of right-of-way 35 feet from the
centerline is required if not already existing.
2. Repair or replace any curb, gutter, sidewalk and access ramps that are
damaged and not in compliance with ADA recommendations in the public right-
of-way prior to occupancy.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
Entergy: No comments received.
Summit Energy: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Due to the nature of this facility, installation of an approved reduced pressure
zone backflow preventer assembly (RPZ) is required on the domestic water
service. This assembly must be installed prior to the first point of use. Central
Arkansas Water (CAW) requires that upon installation of the RPZA, successful
tests of the assembly must be completed by a Certified Assembly Tester
licensed by the State of Arkansas and approved by CAW. The test results must
be sent to CAW's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 377-1226 if you
would like to discuss backflow prevention requirements for this project.
September 10, 2026
ITEM NO.: 10 (Cont.) FILE NO.: Z-10352
3
Fire Department:
All projects submitted for zoning approval must comply with the Arkansas
Fire Prevention Code, 2021 Edition, including any comments or
requirements provided by the Little Rock Fire Marshal's Office.
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with asphalt, concrete or other approved driving surface capable of
supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height.
Buildings or facilities exceeding 30 feet or three stories in height shall have at least
two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provided with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
September 10, 2026
ITEM NO.: 10 (Cont.) FILE NO.: Z-10352
4
buildings are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceeds 30’, approved aerial fire apparatus
access roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever
is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a maximum
of 30 feet from the building and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road is
positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located
over the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be placed with the
approval of the fire code official.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two-Family dwelling residential developments. Developments
September 10, 2026
ITEM NO.: 10 (Cont.) FILE NO.: Z-10352
5
of one- or two-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads and
shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with
future development, as determined by the fire code official.
Contact Chief Davbram Flowers at (501) 918-3780, Capt. Tony Rhodes at (501)
918-3757, Fire Marshal Derek N Ingram (501) 918-3756, or Fire Marshal Evan
Johnson (501) 765-1646.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt.
Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
If you have any additional questions, please contact our office. . Contact
Capt. Tony Rhodes at (501) 918-3757, or Fire Marshal Derek N Ingram (501)
918-3756.
Parks and Recreation: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments.
Landscape:
1. Areas shown on submitted site plan as landscape comply with City’s
ordinance requirements of coverage.
2. At time of building permit request a site development landscape and
screening plan, must be submitted for review and approval, prior to site work
commencing.
3. Landscaping plan submitted must be prepared by a design professional
which complies with Chapter 15 of the City Ordinance.
September 10, 2026
ITEM NO.: 10 (Cont.) FILE NO.: Z-10352
6
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
Land Use Plan:
The request is in Planning District 4, the Heights/Hillcrest Planning District. The
development principles of this district include developing facilities for all modes of
transportation and the preservation of greenways, open spaces, and significant
environmental features and systems. The Land Use Plan shows Office (O) for the
application area. The Office (O) category represents services provided directly to
consumers (e.g., legal, financial, medical) as well as general offices which support
more basic economic activities.
To the north of the application is area designated for Residential High Density (RH)
uses and is characterized by apartment buildings of 3 to 20 units. East and west
of the application area are areas designated for Office (O) uses and are
characterized by medical and professional offices. South of application area is area
designated for Park/Open Space (PK/OS) uses and is characterized by War
Memorial Park.
The subject site is located in the Midtown Design Overlay District (Ord. 19754).
The purpose of the Midtown Design Overlay District is to create a medium-density
urban neighborhood where people can live, work, and shop in a well-connected
pedestrian-friendly neighborhood to create a unique sense of place..
Master Street Plan:
West Markham Street is a Minor Arterial on the Master Street Plan. Minor Arterials
are high volume roads designed to provide the connections to and through an
urban area. Curb cuts should be minimized to allow for continuous traffic flow while
still allowing some access to adjoining property. Deceleration Lanes are required.
Standard Right-of-way (ROW) is 90 feet. Sidewalks are required on both sides.
This street may require dedication of right-of-way and may require street
improvements.
Bicycle Plan:
West Markham Street is not shown on the Master Bike Plan with existing or
proposed facilities in this area.
September 10, 2026
ITEM NO.: 10 (Cont.) FILE NO.: Z-10352
7
Historic Preservation Plan:
The application, as shown, should have no effect on identified historic resources.
H. ANALYSIS:
The applicant requests a conditional use permit to allow for the development of a
specialty outpatient veterinary clinic. The clinic will not contain overnight boarding,
outdoor kennels, or other high-intensity animal care activities. Subject property is
located within the Midtown Design Overlay District (DOD).
The proposed site is located on the north side of the W. Markham Street corridor
(Minor Arterial) and contains existing buildings previously utilized for office or
commercial uses within the O-3 zoning district. Surrounding properties contain a
mixture of zoning and uses. War Memorial Park, St. Vincent Medical Center and
Arkansas State Hospital are located to the south of proposed site.
Access to the site is provided by a twenty-four (24) foot wide driveway apron near
the southwest corner of the site. An existing driveway near the front property line
of Tract 2 will be abandoned. A second access is located near the northwest corner
of the site will be gated and contain and knox box.
The developer proposes to build a new five (5) foot sidewalk the length of the site
as part of the overall development.
The site plan shows a front building setback of 24.5 feet from the front property
line, over fifteen (15) feet from the rear property line and over ten (10) feet from
side property lines.
The developer will utilize the existing one-story, 2,664 square foot building near
the center portion of the overall site.
The applicant provided the following information regarding the proposed
development:
“Existing building at 5512 W. Markham Street to be renovated. Existing building
and concrete slab at other properties to be demolished. The proposed use is
specialty outpatient veterinary clinic. The proposed clinic will not include overnight
boarding, outdoor kennels, or other high-intensity animal care activities.
The project consists of interior renovations and site improvements while
maintaining the existing building footprint at 5512 W. Markham Street. Site
improvements will include parking lot renovations, updated landscaping, and the
removal of unnecessary paved areas to increase green space and reduce
September 10, 2026
ITEM NO.: 10 (Cont.) FILE NO.: Z-10352
8
impervious surface.
A small, fenced animal outdoor relief area is proposed. This space is intended
solely for brief, supervised use, and animals will remain attended by clinic staff or
their owners. The relief area is not intended for exercise, boarding, or extended
outdoor occupancy.
The proposed use is compatible with the surrounding office and commercial
developments. As an appointment-based specialty outpatient clinic, the facility is
expected to generate traffic volumes comparable to other professional office uses.”
The site plan shows twelve (12) parking spaces, including one (1) ADA parking
space. The proposed plan complies with code.
The site plan shows a monument sign along W. Markham Street. All signs placed
on the property must comply with Section 36-389(g) of the City’s Zoning Ordinance
– Midtown Design Overlay District.
Any dumpster (trash enclosure) placed on the site must be screened as per
Section 36-389(e)(2) and (3) of the City’s Zoning Ordinance – Midtown Design
Overlay District.
The site plan shows a fence extending the entire width of rear property line. Any
fence or wall erected must comply with Section 36-516 of the City’s Zoning
Ordinance.
All site lighting shall be low-level and directed away from adjacent properties.
To staff’s knowledge, there are no outstanding issues associated with this
application. Staff feels the request is reasonable and represents a good re-
development plan for the proposed property and meets the general intent of the
DOD. The proposed use is located along the W. Markham Street corridor (Minor
Arterial) which contains a mixture of commercial, office and retail zoning and uses.
Staff feels the use is consistent with the development pattern in the area. Staff
feels the proposed use should have no adverse impact on the surrounding
properties.
STAFF RECOMMENDATION:
Staff recommends approval of the requested conditional use permit, subject to
compliance with the comments and conditions outlined in paragraphs D, E, and F,
and the staff analysis of the agenda staff report.
September 10, 2026
ITEM NO.: 10 (Cont.) FILE NO.: Z-10352
9
PLANNING COMMISSION ACTION: (September 10, 2026)
The applicant was present. There were no objectors present. The application was
placed on the Consent Agenda for approval as recommended by staff. There was
a motion to approve the Consent Agenda. The motion passed by a vote of
11 ayes, 0 nays, 0 absent. The application was approved.