HomeMy WebLinkAboutZ-10331 Staff Report 082626ITEM NO.: 9 FILE NO.: Z-10331
NAME: Saraheen Accessory Dwelling – Conditional Use Permit
LOCATION: 10200 Sardis Road
OWNER/AUTHORIZED AGENT:
Aladdin Saraheen (Owner)
10200 Sardis Road
Mabelvale, AR 72103
SURVEYOR/ENGINEER:
Brooks Surveying, Inc
20820 Arch Street Pike
Little Rock, AR 72065
AREA: 4 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 7
CURRENT ZONING: R-2
VARIANCES:
None requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant requests a conditional use permit to allow placement of a double-wide manufactured home to serve as an accessory dwelling on the R-2 zoned property located at 10200 Sardis
Road.
B. EXISTING CONDITIONS:
The property contains an existing, one-story 1,767 square foot, single-family residence near the southwestern corner of the property. An existing driveway is located near the southwest
corner and provides access to the property. Several properties in the area contain existing manufactured homes. Surrounding properties contain a mixture of zoning and uses. Morehart
Park abuts subject property along the south property line.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood associations registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS (PLANNING DIVISION):
No Comments.
ENGINEERING COMMENTS (PUBLIC WORKS): No Comments.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water:
A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges.
All Central Arkansas Water requirements in effect at the time of request for water service must be met.
Fire Department:
All projects submitted for zoning approval must comply with the Arkansas Fire Prevention Code, 2021 Edition, including any comments or requirements provided by the Little Rock Fire Marshal's
Office
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where
a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent
in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of
buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with asphalt, concrete or other approved driving surface
capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two-Family dwelling residential developments. Developments of one- or two-family dwellings where
the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads and shall meet the requirements of Section D104.3.
Exceptions:
Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler
system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required.
The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the
fire code official.
Contact Chief Davbram Flowers at (501) 918-3780, Capt. Tony Rhodes at (501) 918-3757, Fire Marshal Derek N Ingram (501) 918-3756, or Fire Marshal Evan Johnson (501) 765-1646.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756 Number and Distribution of Fire
Hydrants as per Table C105.1.
If you have any additional questions, please contact our office. . Contact Capt. Tony Rhodes at (501) 918-3757, or Fire Marshal Derek N Ingram (501) 918-3756.
Parks and Recreation: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments.
Landscape: No Comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
Land Use Plan:
The request is in Planning District 15, the Geyer Springs West Planning District. The development principles of this district include developing facilities for all modes of transportation
and the preservation of greenways, open spaces, and significant environmental features and systems. The Land Use Plan shows Residential Low Density (RL) for the application area. The
Residential Low Density (RL) category provides for single family homes at densities not to exceed 6 dwelling units per acre. Such residential development is typically characterized
by conventional single family homes but may also include patio or garden homes and cluster homes, provided that the density remains less than 6 units per acre.
To the north, east, and southwest of the application area are areas designated for Residential Low Density (RL) uses and are characterized by woodlands, single-family residences, and
mobile homes. South of the application area is area designated for Park/Open Space (PK/OS) uses and is characterized by Morehart Park. West of the application area is area designated
for Public/Institution uses and is characterized by Little Oaks Park.
This site is not located in an Overlay District.
Master Street Plan:
Sardis Road is a Local Street on the Master Street Plan. Local Streets are roads designed to provide access to adjacent property with the movement of traffic being a secondary purpose.
The standard Right-of-way is 50’. Sidewalks are required on one side. This street may require dedication of right-of-way and may require street improvements.
Bicycle Plan:
Sardis Road is not shown on the Master Bike Plan with existing or proposed facilities in this area.
Historic Preservation Plan:
The application, as shown, should have no effect on identified historic resources.
H. Analysis:
The applicant requests a conditional use permit to allow placement of a double-wide manufactured home to serve as an accessory dwelling on the R-2 zoned property located at 10200 Sardis
Road.
The property contains an existing, one-story 1,767 square foot single-family residence near the southwestern corner of the property. Access is provided by an existing driveway near the
southwest corner of the property. Several properties in the area contain existing manufactured homes. Surrounding properties contain a mixture of zoning and uses. Morehart Park abuts
subject property along the south property line.
The applicant proposes to place a 30’x80’ double-wide manufactured home approximately sixty (60) feet east of the existing residence. All building setbacks and required separation from
existing structures comply with code.
Section 36-502 requires one (1) parking space for the proposed use. The applicant notes a parking pad between the existing residence and proposed manufactured home will be utilized for
required off-street parking. The driveway and parking pad construction must comply with code.
Short-Term Rental (STR) use of the accessory dwelling unit (ADU) is not permitted
at any time.
Any new fence or wall erected must comply with Section 36-516 of the City’s
Zoning Ordinance.
Any porches, stairs, decks or accessory structures must comply with established
building setbacks for the R-2 zoning district.
Section 36-254(d)(5) of the City's Zoning Ordinance regulates the placement of manufactured homes as follows:
a pitched roof of three (3) in twelve (12) or fourteen (14) degrees or greater
Removal of all transport elements.
Permanent foundation.
Exterior wall finished so as to be compatible with the neighborhood.
Orientation compatible with placement of adjacent structures.
Underpinning with permanent materials.
All homes shall be multi-sectional.
Off-street parking per single-family dwelling standard.
Staff is supportive of the requested conditional use permit to allow a manufactured home to serve as an accessory dwelling. The applicant is requesting no variances with this application.
Several properties in the area contain existing manufactured homes. Staff believes the proposed manufactured home will have no adverse impact on the general area.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested Conditional Use Permit subject to compliance with the comments and conditions outlined in paragraph E, and the staff analysis, of the agenda
staff report.