Loading...
HomeMy WebLinkAboutPC Minutes 091526September 10, 2026 ITEM NO.: 7 FILE NO.: S-2032 NAME: Rachel's Crossing – Preliminary Plat LOCATION: East side of Drew Drive, Approximately 200 feet south of Cantrell Road DEVELOPER: Cook Capital, LLC 511 W. 5th Street North Little Rock, AR 72114 OWNER/AUTHORIZED AGENT: Alexander I, LLC - Owner Joe White and Associates - agent SURVEYOR/ENGINEER: Joe White and Associates 25 Rahling Circle, Suite A-2 Little Rock, AR 72223 AREA: 0.6175 acre NUMBER OF LOTS: 5 FT.NEW STREET: 0 l.f. WARD: 5 CURRENT ZONING: R-2 VARIANCE/WAIVERS: Variance for reduced lot depth for Lot 1. A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT: The applicant requests to subdivide 0.6175 acres of R-2 zoned property into five (5) lots for single family residential development. Four (4) of the five (5) lots will be developed as per the zero lot line standards. B. EXISTING CONDITIONS: Subject property is currently undeveloped and mostly grass covered. September 10, 2026 ITEM NO.: 7 (Cont.) FILE NO.: S-2032 2 C. NEIGHBORHOOD NOTIFICATIONS: All owners of property located adjacent to the site and all neighborhood associations registered with the City of Little Rock were notified of the public hearing. D. ENGINEERING COMMENTS (PLANNING): 1. Dimensions for proposed street improvements needed. 2. All documents are to be submitted to Planning and Development for complete plan check. 3. All documents shall be prepared based on the current Arkansas Fire Prevention Codes, City of Little Rock Municipal codes and ordinances, and current Stormwater Management and Drainage Manual. 4. Any new development shall be reviewed to ensure all codes, specifications, and ordinances are met before issuing any related permits. ENGINEERING COMMENTS (PUBLIC WORKS): 1. With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Drew Drive including 5-foot sidewalks with planned development. The new back of curb should be placed 13 ft from the center of the existing street pavement. 2. A City of Little Rock street improvement project is recommended to the Little Rock Board of Directors for Drew Drive at the Cantrell Road intersection. If approved, construction will occur prior to the end of 2029. Street improvements are required of the applicant until the day of bid opening or for those improvements not constructed by the proposed street improvement project. E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING: Little Rock Water Reclamation Authority: Sewage plans will need to be provided. Entergy: No comments received. Summit Utilities: No comments. September 10, 2026 ITEM NO.: 7 (Cont.) FILE NO.: S-2032 3 AT & T: No comments received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. Fire Department: Must Comply with Arkansas Fire Prevention Code 2021 edition All projects submitted for zoning approval must comply with the Arkansas Fire Prevention Code, 2021 Edition, including any comments or requirements provided by the Little Rock Fire Marshal's Office, prior to acceptance. Maintain Access: Fire Hydrants Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied, and the applicant must submit request to be reviewed by Fire Chief for Approval. Loading Maintain fire apparatus access road design as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. One- or Two-Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two-Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 September 10, 2026 ITEM NO.: 7 (Cont.) FILE NO.: S-2032 4 shall be provided with two separate and approved fire apparatus access roads and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Contact Chief Davbram Flowers at (501) 918-3780, Capt. Tony Rhodes at (501) 918-3757, Fire Marshal Derek N Ingram (501) 918-3756, or Fire Marshal Evan Johnson (501) 765-1646. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 – C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1. If you have any additional questions please contact our office. .  Contact Capt. Tony Rhodes at (501) 918-3757, or Fire Marshal Derek N Ingram (501) 918-3756. F. BUILDING CODES/LANDSCAPE: Building Codes: Footings and overhang must be entirely on the lot and cannot overhang or encroach on the property line for zero lot line construction. Landscape: No comments G. TRANSPORTATION/PLANNING: Rock Region Metro: No comments received. September 10, 2026 ITEM NO.: 7 (Cont.) FILE NO.: S-2032 5 Planning Division: Land Use Plan: The request is in Planning District 19, the Chenal Planning District. The development principles of this district include developing facilities for all modes of transportation and the preservation of greenways, open spaces, and significant environmental features and systems. The Land Use Plan shows Residential Low Density (RL) for the application area. The Residential Low Density (RL) category provides for single family homes at densities not to exceed 6 dwelling units per acre. Such residential development is typically characterized by conventional single family homes but may also include patio or garden homes and cluster homes, provided that the density remains less than 6 units per acre. To the north of the application area is area designated for Suburban Office (SO) uses and is characterized by a veterinarian clinic, a single-family residence, and an office space. South, east, and west of the application area are areas designated for Residential Low Density (RL) uses and are characterized by single-family residences. The subject site is located in the Highway 10 Design Overlay District (Ord. 15965). The purpose of this district is to protect and enhance the aesthetic and visual character of the lands surrounding Highway 10. Master Street Plan: Drew Drive is a Local Street on the Master Street Plan. Local Streets are roads designed to provide access to adjacent property with the movement of traffic being a secondary purpose. The standard Right-of-way is 50’. Sidewalks are required on one side. This street may require dedication of right-of-way and may require street improvements. Bicycle Plan: Drew Drive is not shown on the Master Bike Plan with existing or proposed facilities in this area. Historic Preservation Plan: The application, as shown, should have no effect on identified historic resources. September 10, 2026 ITEM NO.: 7 (Cont.) FILE NO.: S-2032 6 ANALYSIS: The applicant requests to subdivide 0.6175 acres of R-2 zoned property into five (5) lots for single family residential development. Four (4) of the five (5) lots will be developed as per the zero lot line standards. Subject property is currently undeveloped and mostly grass covered. The proposed lot sizes are as follows: Lot 1 - 7,915.7 sq. ft. Lot 2 - 4,640.5 sq. ft. Lot 3 - 4,819.0 sq. ft. Lot 4 - 4,866.4 sq. ft. Lot 5 - 4,657.1 sq. ft. According to Section 36-254(d)(4) of the City's Zoning Ordinance, the minimum lot area regulations are as follows: "(4) Lot area regulations. There shall be a lot area of not less than six thousand (6,000) square-feet. In addition, there shall be a minimum lot width of not less than fifty (50) feet and a minimum lot depth of not less than one hundred (100) feet. For purposes of zero-lot-line lots, the minimum lot width may be reduced to not less than thirty-five (35) feet. The lot area shall not be less than four thousand (4,000) square-feet." The applicant is requesting one (1) variance from the lot area regulations. Lot 1 has a lot depth of slightly over 85 feet. The code requires a minimum lot depth of 100 feet. Staff supports the variance request. All of the proposed minimum building setbacks conform with ordinance standards. To staff's knowledge, there are no outstanding issues associated with the proposed plat. Staff supports the proposed preliminary plat. STAFF RECOMMENDATION: Staff recommends approval of the requested preliminary plat, subject to compliance with the comments and conditions outlined in paragraphs D, E, and F, and the staff analysis, of the agenda staff report. September 10, 2026 ITEM NO.: 7 (Cont.) FILE NO.: S-2032 7 PLANNING COMMISSION ACTION: (September 10, 2026) The applicant was present. There were no objectors present. The application was placed on the Consent Agenda for approval as recommended by staff. There was a motion to approve the Consent Agenda. The motion passed by a vote of 11 ayes, 0 nays, 0 absent. The application was approved.