Loading...
HomeMy WebLinkAboutZ-10252 Minutes File No.: Z-10252 Owners: Dalton Farley Applicant: Dalton Farley Address: 82 Calion Court Legal Description: Lot 62, Block 59 of Chenal Valley, an addition to the City of Little Rock, Pulaski County Arkansas Zoned: R2 Present Use: Vacant Proposed Use: Single Family Residence Variance(s) Requested: A variance is requested to the regulations of Sec. 36-254 to allow a reduced side yard setback in an R-2 Zoning. Justification: The applicant’s justification was presented with the application. STAFF REPORT Planning and Development Civil Engineering Comments: Arkansas Fire Prevention Code 2021 Chapter 4 Foundations Section R401.3 Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection that does not create a hazard.  Lots shall be graded to drain surface water away from foundation walls.  The grade shall fall a minimum of 6 inches (152mm) within the first 10 feet (3048mm).Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches (152mm) of fall within 10 feet (3048mm), drains or swales shall be constructed to ensure drainage away from the structure.  Impervious surfaces within 10 feet (3048mm) of the building foundation shall be sloped a minimum of 2 percent away from the building.  B. Buffering and Landscape Comments: No Comments C. Building Codes Comments: No Comment D. Staff Analysis: The R-2 zoned property located at 82 Calion Court is currently vacant. The survey indicates a lot width of 55 feet along Calion Court, and an average depth of 120 feet. The property is currently scheduled for a proposed new residence to be constructed on the site. Access to the property is from Chenal Parkway off of Highway 10 near the Walmart. The site plan indicates that the applicant proposes to offset the new dwelling on the site and is requesting a two (2) foot reduction of the west side yard setback from six (6) foot to a four (4) foot side yard setback. Section 36-254(d)(2) states, “There shall be a side yard setback on each side of the building having a width of not less than ten (10) percent of the average width of the lot, not to exceed eight (8) feet.”. Therefore, the applicant is requesting a variance to allow a two (2) foot reduction in the west side yard setback for new residential construction, thusly allowing the new construction to extend into the west side yard setback reducing the setback to no less than 4-feet on the west side. Staff is supportive of the requested variance. Staff views the request as reasonable. The proposed variance requested is generally in conformance with the development pattern in the area. Staff believes the proposed altered side yard setbacks will have no adverse impact on the surrounding properties. E. Staff Recommendation: Staff recommends approval of the requested variance for the west side yard setback reduction to no less than 4-feet, with the following conditions: Obtain a building permit prior to construction _____________________________________________________________________ Board of Adjustment (March 19, 2026) The applicant was present. The application came off consent agenda. Staff spoke of concerns about the requested variance allowing the proposed structure to encroach closer to the existing drainage easement. After much discussion a motion was made to defer the application until the April 16, 2026 agenda to give staff more time to consult with Civil on this issue. There was a second, the vote was 4 ayes, 0 nays and 1 absent. The motion passed. The application was then deferred to the April 16, 2026 Board of Adjustment Agenda.