Loading...
HomeMy WebLinkAboutElevation 1LINEN42"x84"SHOWERMASTERBATH26682030MASTERBEDROOM KITCHENTRASHD.W.36" REF LAUNDRYBATH 2CLOSETCLOSET2868DBL. 2068DBL. 206828682668HALL PANTRY3068 3068 MASTERCLOSET2668CLOSET2668BEDROOM 2BEDROOM 2DINING ROOM28683050DBL. 3050DBL. 3050LIVING ROOM3068 30603080306049'-0"4'-8"3'-10"18'-4"13'-4"COVEREDPORCH39'-0" 17'-8"7'-4"7'-4" 14'-4"2'-4"5'-8"2'-4" 2668 MECHCLOSET26683068LOCKERS5'-0"3'-10"3068 2668SHELVESVEST.6'-8"2068LINEN14'-4"13'-8"17'-8"17'-8"DETACHEDGARAGE180703068 23'-0"21'-0"23'-0"6'-0"5'-0"6'-10"8'-10"3'-7"5'-3"5'-3"3'-7"4'-8"9'-8"3'-0"3'-0"2'-0"16'-8"6'-0"3'-4"4'-4"4'-10"9'-4"4'-4"4'-8"13'-0"4'-4"6'-6"3'-2"4'-8"2'-8"4'-0"4'-0"5'-8"4'-0"8'-0"5'-6"4'-2"2'-8"4'-8"3'-10"2'-11"2'-8"7'-8"4'-0"4'-0"4'-0"3'-4"78'-0"39'-0" 18'-0"21'-0" PO Box 34346 Little Rock, AR 72203 Ph: 501-690-2471 aldersondesignco@gmail.com03-14-26Proj No: AR25049NathanAldersonFLOOR PLANA-1.0FIRST FLOOR PLAN1Scale: 1/4" = 1'-0"ArchitectLITTLE ROCK, AR 72206 121 E 24th ST.AREA (Sq. Ft.)FIRST FLOOR LIVING AREAw/ Ext.Veneer1,922TOTAL LIVING AREAGARAGE / STORAGEEXTERIOR COVERED AREA781,922528BASEMENT FLOOR AREA0SQ. FT. TOTALSSECOND FLOOR LIVING AREA0GENERAL NOTES:1.CONTRACTOR TO VERIFY ALL DIMENSIONSPRIOR TO START OF CONSTRUCTION. NOTIFYDESIGNER OF ANY DISCREPANCIES.2.ALL DIMENSIONS ARE FROM FACE OF STUD TOFACE OF STUD UNLESS OTHERWISE NOTED.3.FIXTURES, APPLIANCES, AND SECTION DETAILSARE GIVEN AS STANDARD EXAMPLES AND MAYNOT REFLECT ACTUAL CONSTRUCTION.4.FIREPLACE EXACT SPECIFICATIONS AND SIZE TOBE VERIFIED BY CONTRACTOR PRIOR TOCONSTRUCTION OR ON-SITE AS REQUIRED.5.LOCATIONS, SPECIFICATIONS AND SIZE OF FLUESAND VENTS TO BE DETERMINED BY CONTRACTORPRIOR TO CONSTRUCTION OR ON-SITE ASREQUIRED.DISCLAIMER:ALL PLANS ARE DRAWN TO CUSTOMER SPECIFICATIONS AND WILL CONFORM TO THE APPLICABLE BUILDING CODE(S). ALDERSON DESIGN CO. (ADC) HAS NOT BEEN CONTRACTED TO PROVIDE PERSONAL CONSULTATION, SITE SUPERVISION OR FIELD INSPECTION SERVICES AND HAVE NO CONTROL OVER THE CONSTRUCTION MATERIALS, METHODS, OR SEQUENCING USED BY THE BUILDER. ADC ASSUMES NO RESPONSIBILITY FOR ANY DAMAGES, INCLUDING STRUCTURAL FAILURES RESULTING FROM ERRORS OR OMISSION IN THESE CONSTRUCTION DRAWINGS. DUE TO THEVARIETY OF LOCAL BUILDING REGULATIONS, THESE DRAWINGS MAY NEED TO BE MODIFIED TO COMPLY WITH LOCAL REQUIREMENTS. IT IS NOT THE RESPONSIBILITY OF ADC TO CONSULT THE LOCAL BUILDING OFFICIAL(S). THESE DRAWINGS, AS A WHOLE OR IMPART, IS THE PROPERTY OF ADC. ANY REPRODUCTION AND/OR MANIPULATION OF ANY KIND, WITHOUT PERMISSION IN WRITING FROM ADC IS STRICTLY PROHIBITED.TOTAL UNDER ROOF2,528w/o Ext.Veneer1,828781,828483002,389PLAN NOTES:1.9'-0" CEILING HEIGHT FIRST FLOOR UNLESSOTHERWISE NOTED.