Loading...
HomeMy WebLinkAboutPC Combined Act Ltr & Minutes 081326Department of Planning and Development 723 West Markham Street Little Rock, Arkansas 72201-1334 Phone: (501)371-4790 Fax: (501)371-4546 6-15-2026 Tucker Land Surveying, Inc. P.O. Box 1021 Cabot, AR 72023 Re: S-2019 Myriad Addition - Minor Subdivision - Preliminary Plat/Final Plat Immediately south of 11100 Legion Hut Road Dear Mr. Tucker, This Is to advise you that in connection with your request concerning the above referenced file number, the following action was taken by the Planning Commission at its meeting on June 11, 2026. Approved with conditions; Approved as Submitted; Recommended approval with conditions; Recommended approval as submitted; Denied your request as submitted; Deferred to the __________________________ Meeting; _____________ ______________ ______________ ______________ ______________ ______________ ______________ Other; _________________________________ If you have any questions, please do not hesitate to contact me at (501) 371 -4792 Respectfully, Monte Moore Development Administrator See Minutes for Conditions June 11, 2026 ITEM NO.: 13 FILE NO.: S-2019 NAME: Myriad Addition - Minor Subdivision - Preliminary Plat/Final Plat LOCATION: Immediately south of 11100 Legion Hut Road DEVELOPER: Kerry Weathers Cabot, AR OWNER/AUTHORIZED AGENT: Carlili Valladares/Jesus Rayes - owners Nick Tucker - agent SURVEYOR/ENGINEER: Tucker Land Surveying, Inc. P.O. Box 1021 Cabot, AR 72023 AREA: 1.16 acres NUMBER OF LOTS: 4 FT. NEW STREET: 0 L.F. WARD: 2 CURRENT ZONING: R-2 VARIANCE/WAIVERS: 1. Variance to allow an increased lot width to depth ratio. A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT: The applicant proposes to subdivide 1.16 acres of property into four (4) lots for single family residential development. B. EXISTING CONDITIONS: The property is currently undeveloped. C. NEIGHBORHOOD NOTIFICATIONS: June 11, 2026 ITEM NO.: 13 (Cont.) FILE NO.: S-2019 2 All owners of property abutting the site and all neighborhood associations registered with the City of Little Rock were notified of the public hearing. D. ENGINEERING COMMENTS (PLANNING DIVISION): 1. All documents shall be prepared based on the current Arkansas Fire Prevention Codes, City of Little Rock Municipal codes and ordinances, and current Stormwater Management and Drainage Manual. 2. All streets to meet the current City of Little Rock Master Street Plan. 3. Any new development shall be reviewed to ensure all codes, specifications, and ordinances are met before issuing any related permits. ENGINEERING COMMENTS (PUBLIC WORKS): 1. Repair or replace any curb, gutter, sidewalk and access ramps that are damaged, missing, and not in compliance with ADA recommendations in the public right-of-way prior to approval of final plat. 2. Legion Hut Road is classified as a collector street. Right-of-way should be dedicated to 30 ft from right-of-way centerline. 3. Storm water detention ordinance applies to this property. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or local property owners’ association and detailed in the bill of assurance. E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING: Little Rock Water Reclamation Authority: No comment. Entergy: No comments received. Summit Utilities: No comments. AT & T: No comments received. Central Arkansas Water: Show and reference existing 25 ft wide utility easement centered on the existing 6” and 8” main. Book # 1285 Page #269 -270. Fire Department: Must Comply with Arkansas Fire Prevention Code 2021 edition All projects submitted for zoning approval must comply with the Arkansas Fire Prevention Code, 2021 Edition, including any comments or requirements provided by the Little Rock Fire Marshal's Office June 11, 2026 ITEM NO.: 13 (Cont.) FILE NO.: S-2019 3 Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval. Loading Maintain fire apparatus access road design as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Parks and Recreation: No comments received. County Planning: No comments received. F. BUILDING CODES/LANDSCAPE: Building Codes: No comments received. Landscape: No comments. G. TRANSPORTATION/PLANNING: Rock Region Metro: No comments received. Planning Division: Land Use Plan: The request is in Planning District 15, the Geyer Springs West Planning District. The development principles of this district seek to minimize potential negative impacts between industrial and residential usage, and to improve traffic circulation. The Land Use Plan shows Residential Low Density (RL) for the June 11, 2026 ITEM NO.: 13 (Cont.) FILE NO.: S-2019 4 application area. The Residential Low Density (RL) category provides for single- family homes at densities not to exceed 6 dwelling units per acre. Such residential development is typically characterized by conventional single-family homes but may also include patio or garden homes and cluster homes, provided that the density remains less than 6 units per acre. To the north, south, and west of the application area are areas designated for Residential Low Density (RL) uses and are characterized by single-family homes. East of the application area is area designated for Residential Medium Density (RM) and is characterized by a mobile home park. This site is not located in an Overlay District. Master Street Plan: Legion Hut Road is a Collector on the Master Street Plan. Collectors are designed to connect traffic from Local Streets to Arterials or to activity centers, with the secondary function of providing access to adjoining property. The standard Right of way is 60’. Sidewalks are required on one side of Collectors. This street may require dedication of right-of-way and may require street improvements. Bicycle Plan: Legion Hut Road is not shown on the Master Bike Plan with existing or proposed facilities in this area. Historic Preservation Plan: The application, as shown, should have no effect on identified historic resources. H. ANALYSIS: The applicant proposes to subdivide 1.16 acres of property into four (4) lots for single family residential development. The property is located on the west side of Legion Hut Road, immediately south of 11100 Legion Hut Road. The property is currently undeveloped. The approximate sizes for the four (4) proposed lots will be as follows: Lot 1 - 58.89 feet by 187.59 feet (11,047 sq. ft.) Lot 2 - 58.70 feet by 187.6 feet (11,012 sq. ft.) Lot 3 - 58.79 feet by 187.7 feet (11,034 sq. ft.) Lot 4 - 58.88 feet by 187.85 feet (11,060 sq. ft.) June 11, 2026 ITEM NO.: 13 (Cont.) FILE NO.: S-2019 5 The property is being subdivided as per the minor subdivision requirements as found in Section 31-142 of the City's Subdivision Ordinance as follows: "Sec. 31-142. - Minor subdivisions. (a) The staff may authorize a combined preliminary and final review procedure for minor subdivisions. All plats submitted as minor subdivisions shall require review and approval by the planning commission. (b) In order to qualify as a minor subdivision, a proposed subdivision must meet the following requirements: (1) The proposed plat does not create more than four (4) lots, tracts or parcels of land. (2) The proposed plat is intended for residential or commercial use only and is not more than five (5) acres in size. (3) The proposed plat does not involve dedication of public street or access easement through rather than adjacent to the lot, tract or parcel proposed for subdivision. (c) Request for minor subdivision approval shall be made by the owner of the land to the department of planning and development. Subdivision requirements shall be the same as those required for the final plat. The planning commission shall review the plat at their nest regularly scheduled monthly meetings. If the final plat is in conformance with the objectives and standards of this chapter and all required information is contained thereon, the planning commission shall certify its approval of the plat, making proper notation on the original tracing of the plat, making proper notation on the original tracing of the plat, and permit the plat's recording in the office of the circuit clerk." Section 31-232(b) of the City's zoning Subdivision Ordinance states that no residential lot shall be more than three (3) times as deep as it is wide. The applicant is requesting a variance from this requirement for the proposed lots. Staff is supportive of the requested variance. To staff's knowledge, there are no outstanding issues associated with the proposed minor subdivision plat. Staff is supportive of the proposed plat with variance, as the requested variance is very minor in nature. June 11, 2026 ITEM NO.: 13 (Cont.) FILE NO.: S-2019 6 I. STAFF RECOMMENDATION: Staff recommends approval of the requested preliminary plat, subject to compliance with the comments and conditions outlined in paragraphs D and E, and the staff analysis, of the agenda staff report. PLANNING COMMISSION ACTION: (June 11, 2026) The applicant was present. There were no objectors present. The application was placed on the Consent Agenda for approval as recommended by staff. There was a motion to approve the Consent Agenda. The motion passed by a vote of 11 ayes, 0 nays, 0 absent. The application was approved.