HomeMy WebLinkAboutZ-10307 Elevations 050726DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:2/19/2026 GENERAL NOTES: THIS PLAN SET, COMBINED WITH THE BUILDING CONTRACT, PROVIDES BUILDING DETAILS FOR THE RESIDENTIAL PROJECT.  THE CONTRACTOR SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. CONTRACTOR SHALL BE RESPONSIBLE AND BEAR ANY FINES OR PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS.  INSURANCES SHALL BE IN FORCE THROUGHOUT THE DURATION OF THE BUILDING PROJECT. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). ALL TRADES SHALL MAINTAIN A CLEAN WORK SITE AT THE END OF EACH WORK DAY. PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. OWNER: _______________________________ PROJECT: ADDRESS: __________________________________ LEGAL: ______________________________ FIRE DISTRICT _____________________________ WATER/SEWER: ____________________________ STORM WATER PERMIT: _____________________ BUILDING PERMIT: _____________________ DESIGNER: J. Duncan DESIGN CONSULTANT: _____________________ BUILDER: SITE DISTURBANCE: _____________________ ENGINEERING: _____________________ Index of DrawingsNOTICE, DISCLAIMER, AND COPYRIGHT: These documents, whether physical or electronic, and together with any attachments, Are confidential and may be the subject of legal privilege. If you are not the intended recipient please return to sender and destroy any copies. You are not permitted to copy, disclose or use the content in any way. J. Duncan provides the attached documents with the following conditions and understandings. All information is issued on the express understanding that the recipient accepts these limitations and disclaimers: 1 . The information must solely and only be used for the coordination and/or construction of the current project.   2 . J. Duncan does not warrant or take responsibility for the accuracy of the information issued.   3 . The information issued may be confidential and must not be used other than by the intended recipient.   4 . J. Duncan accepts no liability or responsibility for any loss or damage suffered by the recipient arising out of, or in connection with, the use or misuse of the information issued.   5 . The copyright of the original documents belongs to J. Duncan. The information is only for use in preparation of documents for this project.  6. The documents may not have been prepared for use by the recipient and may not fully reflect their needs.   7. Do not scale off drawings. Any measurements taken from information which is not dimensioned on the electronic copy are at the risk of the recipient.   8. The recipient is responsible for verifying the correctness and completeness of the information issued. This should be done by consulting all relevant documents supplied during the course of the project and by confirming dimensions on site. 9. Updates may not be issued in electronic form. It is the responsibility of the recipient to ensure they have the most up to date information.   10. If altered or added to in any way, all references to J. Duncan must be removed and those making the changes assume total responsibility for the information thereon. The terms “document” & “information” in the above refers to both text documents and drawings in either ‘hard copy’ or electronic format. THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF J. Duncan. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. Title Sheet Project Summary 1. Floorplan 2. Foundation Plan 3. Exterior Elevations 4. Roofing Plan 5. Door/Window Schedule 6. Perspective Renders 7.2324 Rock StPRINTING TO SCALE: THIS PLAN SET CAN BE PRINTED TO SCALE BY ANY LOCAL PRINTING SHOP, AS LONG AS THE FOLLOWING SPECIFICATION IS MADE: PLAN MUST BE PRINTED AT ACTUAL SIZE IN ORDER TO SCALE PROPERLY. ENSURE THAT PRINT SHOP DOES NOT UTILIZE "FIT TO SHEET" OPTION WHEN PRINTING OR SCALE WILL BE INCORRECT. P-1SHEET:P-1Orndorff Construction 3060FX 3060SH 3060SH3060SH3060SH 3080 3020FX3020FX 3060FX 3020FX 3060FX 2'-1"7'-2"2'-2 1/4"1'-0 1/2"6'-8 1/2"2'-4 3/4"1'-0 1/2"1'-7 3/4"BOTTOM OF FOOTING -2.3' TOP OF SUBFLOOR - FOUNDATION -0.3'2'-1"TOP OF PLATE 9.1'9'-4 1/4"TOP OF SUBFLOOR - 2ND FLOOR 10.1'1'-0 1/2"TOP OF PLATE 19.2'9'-1 1/4"TOP OF SUBFLOOR - 3RD FLOOR 20.3'1'-0 1/2"TOP OF PLATE 22'1'-8 1/2"4'-4"3'8'-8 1/4"3'6' 1'-8 3/4" 26'-9"2'-1"7'-2"2'-2 1/4"1'-0 1/2"6'-8 1/2"2'-4 3/4"1'-0 1/2"1'-7 3/4"BOTTOM OF FOOTING -2.3' TOP OF SUBFLOOR - FOUNDATION -0.3'2'-1"TOP OF PLATE 9.1'9'-4 1/4"TOP OF SUBFLOOR - 2ND FLOOR 10.1'1'-0 1/2"TOP OF PLATE 19.2'9'-1 1/4"TOP OF SUBFLOOR - 3RD FLOOR 20.3'1'-0 1/2"TOP OF PLATE 22'1'-8 1/2"4'-4"3'8'-8 1/4"3'6' 1'-8 3/4" 26'-9" 3060FX 3060SH 3060SH3060SH3060SH 3080 3020FX3020FX 3060FX 3020FX 3060FX 3030FX 12'-1"3'11'-8 3/4" 2'-4 3/4" 26'-9 3/4" 2'-4 3/4" 12'-1"3'11'-8 3/4" 2'-4 3/4" 26'-9 3/4" 2'-4 3/4" 3030FX 3050SH 3050SH 3068 8'-11 1/2"4'3'10'-10 1/4"3' 4 1/2" 3'2'-6" 26'-8 3/4"8'-11 1/2"4'3'10'-10 1/4"3' 4 1/2" 3'2'-6" 26'-8 3/4" 3050SH 3050SH 3068 3060SH3060SH3060SH 6068 2644SH 1'-0 1/2"3 1/2" 6' 4" 5'-5 1/2" 1/4" 2'-6" 5 3/4"4 1/2" 3' 4 1/2" 3'3'-10 1/2" 6'-7 1/2"19'-1" 1'-0 1/2"3 1/2" 6' 4" 5'-5 1/2" 1/4" 2'-6" 5 3/4"4 1/2" 3' 4 1/2" 3'3'-10 1/2" 6'-7 1/2"19'-1" 3060SH3060SH3060SH 6068 2644SH 3050SH 13'-3 3/4"3'12'-10 3/4" 29'-2 1/2" 3050SH 13'-3 3/4"3'12'-10 3/4" 29'-2 1/2" 3050SH 3080 2460FX 2420FX 2460FX 2420FX 13'-1" 3 1/2" 3' 2'-1 1/4" 2'-4"2'-4" 2'-6 1/4"1'-0 3/4" 26'-8 3/4" 3080 2460FX 2420FX2420FX 2460FX 13'-1" 3 1/2" 3' 2'-1 1/4" 2'-4"2'-4" 2'-6 1/4"1'-0 3/4" 26'-8 3/4" 3080 2460FX 2420FX 2460FX 2420FX 4020FX4020FX 4020FX 13'-1" 3 3/4" 3' 2 3/4" 3'-4" 2" 3'-4"3'-3 1/2" 13'-1"13'-8" 13'-1" 3 3/4" 3' 2 3/4" 3'-4" 2" 3'-4"3'-3 1/2" 13'-1"13'-8" 4020FX4020FX 4020FX 4'3'19'-9" 26'-9" 4'3'19'-9" 26'-9"DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:2/19/2026Roof / Exterior ElevationsMain Home Front Elevation For illustration only No Scale Main Home Right Elevation For illustration only No Scale 2324 Rock StMain Home Rear Elevation For illustration only No Scale Main Home Left Elevation For illustration only No Scale SHEET:P-4Orndorff Construction2nd Home Front Elevation For illustration only No Scale 2nd Home Right Elevation For illustration only No Scale 2nd Home Rear Elevation For illustration only No Scale 2nd Home Left Elevation For illustration only No Scale DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:4/9/2026 GENERAL NOTES: THIS PLAN SET, COMBINED WITH THE BUILDING CONTRACT, PROVIDES BUILDING DETAILS FOR THE RESIDENTIAL PROJECT.  THE CONTRACTOR SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. CONTRACTOR SHALL BE RESPONSIBLE AND BEAR ANY FINES OR PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS.  INSURANCES SHALL BE IN FORCE THROUGHOUT THE DURATION OF THE BUILDING PROJECT. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). ALL TRADES SHALL MAINTAIN A CLEAN WORK SITE AT THE END OF EACH WORK DAY. PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. OWNER: _______________________________ PROJECT: ADDRESS: __________________________________ LEGAL: ______________________________ FIRE DISTRICT _____________________________ WATER/SEWER: ____________________________ STORM WATER PERMIT: _____________________ BUILDING PERMIT: _____________________ DESIGNER: J. Duncan DESIGN CONSULTANT: _____________________ BUILDER: SITE DISTURBANCE: _____________________ ENGINEERING: _____________________ Index of DrawingsNOTICE, DISCLAIMER, AND COPYRIGHT: These documents, whether physical or electronic, and together with any attachments, Are confidential and may be the subject of legal privilege. If you are not the intended recipient please return to sender and destroy any copies. You are not permitted to copy, disclose or use the content in any way. J. Duncan provides the attached documents with the following conditions and understandings. All information is issued on the express understanding that the recipient accepts these limitations and disclaimers: 1 . The information must solely and only be used for the coordination and/or construction of the current project.   2 . J. Duncan does not warrant or take responsibility for the accuracy of the information issued.   3 . The information issued may be confidential and must not be used other than by the intended recipient.   4 . J. Duncan accepts no liability or responsibility for any loss or damage suffered by the recipient arising out of, or in connection with, the use or misuse of the information issued.   5 . The copyright of the original documents belongs to J. Duncan. The information is only for use in preparation of documents for this project.  6. The documents may not have been prepared for use by the recipient and may not fully reflect their needs.   7. Do not scale off drawings. Any measurements taken from information which is not dimensioned on the electronic copy are at the risk of the recipient.   8. The recipient is responsible for verifying the correctness and completeness of the information issued. This should be done by consulting all relevant documents supplied during the course of the project and by confirming dimensions on site. 9. Updates may not be issued in electronic form. It is the responsibility of the recipient to ensure they have the most up to date information.   10. If altered or added to in any way, all references to J. Duncan must be removed and those making the changes assume total responsibility for the information thereon. The terms “document” & “information” in the above refers to both text documents and drawings in either ‘hard copy’ or electronic format. THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF J. Duncan. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. Title Sheet Project Summary 1. Floorplan 2. Foundation Plan 3. Exterior Elevations 4. Roofing Plan 5. Door/Window Schedule 6. Perspective Renders 7.2324 Rock St GaragePRINTING TO SCALE: THIS PLAN SET CAN BE PRINTED TO SCALE BY ANY LOCAL PRINTING SHOP, AS LONG AS THE FOLLOWING SPECIFICATION IS MADE: PLAN MUST BE PRINTED AT ACTUAL SIZE IN ORDER TO SCALE PROPERLY. ENSURE THAT PRINT SHOP DOES NOT UTILIZE "FIT TO SHEET" OPTION WHEN PRINTING OR SCALE WILL BE INCORRECT. P-1SHEET:P-1Orndorff Construction