Loading...
HomeMy WebLinkAboutZ-10304 Floor Plans 050626DN DN 3020AW3050SC3010FX3020AW3050SC3010FX3020AW3050SC3010FX 3020AW3050SC3010FX4018FX3020AW3050SC3010FX1650FX 1650FX 1650FX 1650FX 3020AW3050SC3010FX4018FX3020AW3050SC3010FX286826684068266828682668 2268406822682668 3020AW3050SC3010FX3020AW3050SC3010FX3020AW3050SC3010FX 10"1'-6" 7'-9" 1'-6"11 1/2" 6 1/4" 3' 1'-8 1/4" 3' 1'-8 1/4" 3' 6 1/4" 4"3'-0 3/4"7" 3' 1'-8 1/4" 3' 1'-8 1/4" 3' 6" 1'-3 1/2" 13'-5 1/2" 10"6 1/4"1'-1 3/4" 13'-5" 1'-4" 32'10 1/4"3'11'-9 1/2"10"4'6 1/4"7'-11 1/4"4'-4 3/4"3'4'-2 1/2"2'-6"15'-7 3/4"5'-4 1/4"7'-11 1/4"11'-7 1/4"43'-0 1/2"2'-5 3/4"11 1/2"1'-6" 7'-5 1/2" 1'-6"1'-5" 12'-10" 3'-0 3/4"6 1/4"3'-0 1/2" 12'-6 1/2" 32'4'-2 1/2"3'4'-4 3/4"7'-11 1/4"6 1/4"4'10"11'-9 1/2"3'9 3/4"11'-7 1/4"7'-11 1/4"5'-4 1/4"15'-7 1/4"2'-6"43'2'-6 1/4"12'-2" X 10'-11" 1211 SQ FT 9'-8" X 7'-7" 3'-0" X 3'-4" 2'-8" X 7'-7" 12'-2" X 10'-11" 15'-3" X 10'-2" 2'-8" X 7'-7" 3'-0" X 3'-4" 15'-3" X 10'-2" 15'-3" X 7'-8" 9'-8" X 7'-7" 15'-3" X 7'-7" 3'-1" X 5'-0" 5'-7" X 17'-0"5'-7" X 16'-9" 3'-0" X 5'-0" 8'-4" X 5'-0"8'-7" X 5'-0" LIVING AREA PRIMARY BEDROOM FULL HEIGHT CAB TRASH BIN DSHWSHR LIVING KITCHEN CLOSET BATH SHOWER TRASH BIN DSHWSHR CLOSET BATH KITCHEN SHWR PRIMARY BEDROOM LNDRYFULL HEIGHT CAB LNDRY LIVING STAIRWELL STAIRWELL HALLHALL WHWH5016FX30682650SC2650SC30685016FX406830689070907030682068206830682668 3068 206820683068 2668 3068 UP UP 8'-6 1/2"5'1'-6"11 1/2"3'3'-9 1/2"2'-6"1'-3 1/2"1'-3 1/4" 9' 1'-1" 3' 1'-6 1/2"1'-5 1/2" 3' 1'-1" 9' 1'-0 1/2" 15'-7" 6 1/4" 15'-10 3/4" 32'1'-6"5'8'-6 1/2"15'-0 1/2"5'-11"8'11'-6 1/2"40'-6"12'-4 1/2"3'-6 1/4" 6 1/4" 3'-5 1/2"12'-1 1/2" 32'1'-3 1/2"2'-6"3'-9 1/2"3'11 1/2"11'-6 1/2"8'5'-11"15'-0 1/2"40'-6"15'-3" X 20'-7"15'-3" X 20'-7" 11'-9" X 10'-10"3'-0" X 5'-7"2'-9" X 5'-7"6'-5" X 3'-4" 3'-2" X 6'-10"3'-1" X 6'-10" 5'-2" X 7'-8" 11'-9" X 10'-10" 5'-2" X 7'-8"6'-5" X 3'-4" GARAGE BEDROOM 2 GARAGE POWDERPOWDER BEDROOM 1 MECHANICALMECHANICALENTRY ENTRYCLOSET MUDROOMBENCHMUDROOMBENCHCLOSET 1'-9" 3'-2" 11" 9'-2"2'-8"9'-2" 11" 3'-2" 1'-10" 32'-9"7'-10 1/2"3'-2"8'-10 1/2"19'-11"21'-4"41'-3"8'-10 1/2"3'-2"7'-10 1/2"21'-4"19'-11"41'-3"32'-9" 31'-5" X 20'-8" GARAGE DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE: 4/2/2026Square Modern DuplexSHEET:P-21st Floor Plan 1/4" = 1' 2nd Floor Plan 1/4" = 1' Floor Plan Notes 1.ALL EXTERIOR DIMENSIONS ARE TO THE MAIN LAYER. DIMENSIONS TO OPENINGS ARE TO THE FRAMING, ROUGH OPENING. INTERIOR DIMENSIONS ARE TO THE FINISHED WALL. 2.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). 3.TOTAL CONDITIONED SQUARE FOOTAGE 1,427 Floor/ Foundation PlanOrndorff Construction Areas Heated/Cooled 1st floor 2nd Floor Garage Total Slab 1,968 709 1,259 635 1,344 Fire Wall Specif ication 1/4" = 1' 2 layers 5/8" Type X 1 Hour Gypsum Board 2x4 Wood Studs, Batt Insulation 5/8" Type X Gypsum Board 2 layers 5/8" Type X 1 Hour Gypsum Board 2x4 Wood Studs, Batt Insulation 5/8" Type X Gypsum Board T PO Roof / Wall Section FOUNDATION NOTES 1.FOUNDATIONS TO BEAR A MINIMUM OF 16” BELOW FINISH GRADE 2.ALL ANCHOR BOLTS TO BE 5/8” DIA X 10 @ 32” O/C UNO. 3.ALL REINFORCING STEEL SHALL BE ASTM A-615, GRADE 60. 4.ALL REINFORCING STEEL TO OVERLAP A MINIMUM OF 24” FOR SPLICES. 5.PROVIDE CORNER BARS TO MATCH CONTINUOUS STEEL. 6.MINIMUM ALLOWABLE CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI AT 26 DAYS. MAXIMUM AGGREGATE SIZE IS 1”. MAXIMUM AIR ENTRAINMENT IS 3%. CEMENT SHOULD BE TYPE 1 OR 2. 7.SOIL BEARING CAPACITY ASSUMED TO BE 1500 PSF (UBC TYPE 4 SOIL). IF SOIL CONDITIONS VARY FROM THIS, THE PROJECT ENGINEER MUST BE NOTIFIED. ALL FOOTINGS MUST BEAR ON UNDISTURBED SOIL. ALL SLOPES MUST BE STABILIZED. 8.ADJACENT GROUND SURFACES SHALL BE SLOPED AWAY FROM STRUCTURE DRAINAGE OF SURROUNDING AREA SHALL ALSO BE PROVIDED TO PREVENT ACCUMULATION OF SOIL AND EROSION OF SOIL NEAR FOOTINGS. 9.UNIFORM SOIL CONDITIONS, MUST BE PROVIDED UNDER SLAB AND FOOTINGS. CUT/FILL OR NON- UNIFORM SOIL CONDITIONS SHOULD BE EXCAVATED AND REPLACED W/ UNIFORM ENGINEERED FILL MATERIAL TO MINIMIZE DIFFERENTIAL MOVEMENT. 10.THE TOPS OF FOUNDATION WALLS SHALL EXTEND 6” ABOVE THE ADJACENT FINISH GRADE 11.MINIMUM 18” CLEARANCE FOR WOOD JOIST GIRDERS REQUIRED IN THE CRAWL SPACE UNLESS TREATED WOOD IS USED THROUGHOUT FLOOR SYSTEM   MASONRY NOTES 1.ALL CONCRETE MASONRY UNITS TO BE L AID IN CONFORMANCE WITH ASTM C90. 2.CONCRETE MASONRY UNITS TO BE LAID IN TYPE ‘S’ OR TYPE ‘M’ MORTAR IN A RUNNING BOND PATTERN. MORTAR, GROUT AND REINFORCEMENT TO BE IN COMPLIANCE WITH CURRENT CODES. 3.COMPRESSIVE STRESS OF GROUT TO BE: FM’=2500 PSI. ALL CELLS TO BE FULLY GROUTED. 4.ALL REINFORCING STEEL TO BE: ASTM-A-615, GRADE 60.   Foundation Plan 1/4" = 1'