HomeMy WebLinkAboutZ-10304 Floor Plans 050626DN DN
3020AW3050SC3010FX3020AW3050SC3010FX3020AW3050SC3010FX 3020AW3050SC3010FX4018FX3020AW3050SC3010FX1650FX 1650FX 1650FX 1650FX
3020AW3050SC3010FX4018FX3020AW3050SC3010FX286826684068266828682668
2268406822682668
3020AW3050SC3010FX3020AW3050SC3010FX3020AW3050SC3010FX
10"1'-6"
7'-9"
1'-6"11 1/2"
6 1/4"
3'
1'-8 1/4"
3'
1'-8 1/4"
3'
6 1/4"
4"3'-0 3/4"7"
3'
1'-8 1/4"
3'
1'-8 1/4"
3'
6"
1'-3 1/2"
13'-5 1/2"
10"6 1/4"1'-1 3/4"
13'-5"
1'-4"
32'10 1/4"3'11'-9 1/2"10"4'6 1/4"7'-11 1/4"4'-4 3/4"3'4'-2 1/2"2'-6"15'-7 3/4"5'-4 1/4"7'-11 1/4"11'-7 1/4"43'-0 1/2"2'-5 3/4"11 1/2"1'-6"
7'-5 1/2"
1'-6"1'-5"
12'-10"
3'-0 3/4"6 1/4"3'-0 1/2"
12'-6 1/2"
32'4'-2 1/2"3'4'-4 3/4"7'-11 1/4"6 1/4"4'10"11'-9 1/2"3'9 3/4"11'-7 1/4"7'-11 1/4"5'-4 1/4"15'-7 1/4"2'-6"43'2'-6 1/4"12'-2" X 10'-11"
1211 SQ FT
9'-8" X 7'-7"
3'-0" X 3'-4"
2'-8" X 7'-7"
12'-2" X 10'-11"
15'-3" X 10'-2"
2'-8" X 7'-7"
3'-0" X 3'-4"
15'-3" X 10'-2"
15'-3" X 7'-8"
9'-8" X 7'-7"
15'-3" X 7'-7"
3'-1" X 5'-0"
5'-7" X 17'-0"5'-7" X 16'-9"
3'-0" X 5'-0"
8'-4" X 5'-0"8'-7" X 5'-0"
LIVING AREA
PRIMARY BEDROOM
FULL HEIGHT
CAB
TRASH
BIN
DSHWSHR
LIVING
KITCHEN
CLOSET
BATH
SHOWER
TRASH
BIN
DSHWSHR
CLOSET
BATH
KITCHEN
SHWR
PRIMARY BEDROOM
LNDRYFULL HEIGHT
CAB
LNDRY
LIVING
STAIRWELL STAIRWELL
HALLHALL
WHWH5016FX30682650SC2650SC30685016FX406830689070907030682068206830682668
3068 206820683068
2668 3068
UP UP
8'-6 1/2"5'1'-6"11 1/2"3'3'-9 1/2"2'-6"1'-3 1/2"1'-3 1/4"
9'
1'-1"
3'
1'-6 1/2"1'-5 1/2"
3'
1'-1"
9'
1'-0 1/2"
15'-7"
6 1/4"
15'-10 3/4"
32'1'-6"5'8'-6 1/2"15'-0 1/2"5'-11"8'11'-6 1/2"40'-6"12'-4 1/2"3'-6 1/4"
6 1/4"
3'-5 1/2"12'-1 1/2"
32'1'-3 1/2"2'-6"3'-9 1/2"3'11 1/2"11'-6 1/2"8'5'-11"15'-0 1/2"40'-6"15'-3" X 20'-7"15'-3" X 20'-7"
11'-9" X 10'-10"3'-0" X 5'-7"2'-9" X 5'-7"6'-5" X 3'-4"
3'-2" X 6'-10"3'-1" X 6'-10"
5'-2" X 7'-8"
11'-9" X 10'-10"
5'-2" X 7'-8"6'-5" X 3'-4"
GARAGE
BEDROOM 2
GARAGE
POWDERPOWDER
BEDROOM 1
MECHANICALMECHANICALENTRY ENTRYCLOSET
MUDROOMBENCHMUDROOMBENCHCLOSET
1'-9"
3'-2"
11"
9'-2"2'-8"9'-2"
11"
3'-2"
1'-10"
32'-9"7'-10 1/2"3'-2"8'-10 1/2"19'-11"21'-4"41'-3"8'-10 1/2"3'-2"7'-10 1/2"21'-4"19'-11"41'-3"32'-9"
31'-5" X 20'-8"
GARAGE
DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:
4/2/2026Square Modern DuplexSHEET:P-21st Floor Plan
1/4" = 1'
2nd Floor Plan
1/4" = 1'
Floor Plan Notes
1.ALL EXTERIOR DIMENSIONS
ARE TO THE MAIN LAYER.
DIMENSIONS TO OPENINGS
ARE TO THE FRAMING,
ROUGH OPENING. INTERIOR
DIMENSIONS ARE TO THE
FINISHED WALL.
2.CONTRACTOR SHALL
VERIFY ALL DIMENSIONS
AND IS RESPONSIBLE FOR
ALL DIMENSIONS
(INCLUDING ROUGH
OPENINGS).
3.TOTAL CONDITIONED
SQUARE FOOTAGE 1,427 Floor/ Foundation PlanOrndorff Construction Areas
Heated/Cooled
1st floor
2nd Floor
Garage
Total Slab
1,968
709
1,259
635
1,344
Fire Wall Specif ication
1/4" = 1'
2 layers 5/8" Type X
1 Hour Gypsum Board
2x4 Wood Studs, Batt Insulation
5/8" Type X Gypsum Board
2 layers 5/8" Type X
1 Hour Gypsum Board
2x4 Wood Studs, Batt Insulation
5/8" Type X Gypsum Board
T PO Roof / Wall Section
FOUNDATION NOTES
1.FOUNDATIONS TO BEAR A MINIMUM OF 16” BELOW FINISH GRADE
2.ALL ANCHOR BOLTS TO BE 5/8” DIA X 10 @ 32” O/C UNO.
3.ALL REINFORCING STEEL SHALL BE ASTM A-615, GRADE 60.
4.ALL REINFORCING STEEL TO OVERLAP A MINIMUM OF 24” FOR SPLICES.
5.PROVIDE CORNER BARS TO MATCH CONTINUOUS STEEL.
6.MINIMUM ALLOWABLE CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI AT 26 DAYS. MAXIMUM
AGGREGATE SIZE IS 1”. MAXIMUM AIR ENTRAINMENT IS 3%. CEMENT SHOULD BE TYPE 1 OR 2.
7.SOIL BEARING CAPACITY ASSUMED TO BE 1500 PSF (UBC TYPE 4 SOIL). IF SOIL CONDITIONS VARY FROM
THIS, THE PROJECT ENGINEER MUST BE NOTIFIED. ALL FOOTINGS MUST BEAR ON UNDISTURBED SOIL. ALL
SLOPES MUST BE STABILIZED.
8.ADJACENT GROUND SURFACES SHALL BE SLOPED AWAY FROM STRUCTURE DRAINAGE OF SURROUNDING
AREA SHALL ALSO BE PROVIDED TO PREVENT ACCUMULATION OF SOIL AND EROSION OF SOIL NEAR
FOOTINGS.
9.UNIFORM SOIL CONDITIONS, MUST BE PROVIDED UNDER SLAB AND FOOTINGS. CUT/FILL OR NON-
UNIFORM SOIL CONDITIONS SHOULD BE EXCAVATED AND REPLACED W/ UNIFORM ENGINEERED FILL
MATERIAL TO MINIMIZE DIFFERENTIAL MOVEMENT.
10.THE TOPS OF FOUNDATION WALLS SHALL EXTEND 6” ABOVE THE ADJACENT FINISH GRADE
11.MINIMUM 18” CLEARANCE FOR WOOD JOIST GIRDERS REQUIRED IN THE CRAWL SPACE UNLESS TREATED
WOOD IS USED THROUGHOUT FLOOR SYSTEM
MASONRY NOTES
1.ALL CONCRETE MASONRY UNITS TO BE L AID IN CONFORMANCE WITH ASTM C90.
2.CONCRETE MASONRY UNITS TO BE LAID IN TYPE ‘S’ OR TYPE ‘M’ MORTAR IN A RUNNING BOND PATTERN.
MORTAR, GROUT AND REINFORCEMENT TO BE IN COMPLIANCE WITH CURRENT CODES.
3.COMPRESSIVE STRESS OF GROUT TO BE: FM’=2500 PSI. ALL CELLS TO BE FULLY GROUTED.
4.ALL REINFORCING STEEL TO BE: ASTM-A-615, GRADE 60.
Foundation Plan
1/4" = 1'