HomeMy WebLinkAboutResponse to comments 031826
210 W. ARCH AVE., STE. D, SEARCY, AR 72143 | 501.388.2178 | DAVIDSONENGINEERS.COM
March 18, 2026
Torrence Thrower
City of Little Rock Planning & Development
723 W. Markham Street
Little Rock, AR 72201
RE: Mabelvale ARcare
Valley Oaks Court – Revised POD (Z – 47688 - E)
1349 McNutt Rd, Conway, AR
Response to Comments receiver 3/13/2026
Mr. Torrence Thrower,
In reference to your comments (response in blue):
STAFF DEVELOPMENT COMMENTS
1. Proposed Lot 1RR must be developed as per the C-3 development criteria (building height, parking,
landscaping, buffers, etc.).
Concur
1. Building setbacks as shown on proposed replat are acceptable.
Concur
2. Are C-3 permitted uses requested as alternate uses?
Concur
OTHER DEPARTMENTS COMMENTS
CIVIL ENGINEERING
1. All documents are to be submitted to Planning and Development for complete plan check..
Concur
2. All documents shall be prepared by an Arkansas Licensed Professional Engineer.
Concur
3. Land Survey to be no older than five (5) years.
New survey submit on March 3, 2026
4. All documents shall be prepared based on the current Fire Prevention Codes, City of Little Rock
Municipal codes and ordinances, and current City of Little Rock Master Street Plan.
Concur
5. All streets to meet the current City of Little Rock Master Street Plan.
Concur
6. Any new developments shall be reviewed to ensure all codes, specifications, and ordinances are met
before issuing any related permits.
Concur
2 | 4
PUBLIC WORKS ENGINEERING
1. Driveway locations and widths shall meet the traffic access and circulation requirements of Section 30-43
and 31-210. The width of the driveway must not exceed 40 feet;
Concur
2. Storm water detention ordinance applies to this property. Maintenance of the detention pond and all
private drainage improvements is the responsibility of the developer and/ or local property owners’
association and detailed in the bill of assurance.
Concur
LANDSCAPING REVIEW
1. Any new site development must comply with the City’s minimal landscape and buffer ordinance
requirements. Refer to Code of Ordinances, Chapter 15 Landscaping and Tree Protection, and Chapter
36 IX – Buffers and Screening.
Concur
2. Site Development plans, with landscaping and screening, must be submitted for review, and approval,
prior to site clearing and tree removal.
Concur
LITTLE ROCK FIRE DEPARTMENT COMMENTS
1. Must Comply with Arkansas Fire Prevention Code 2021 edition
All projects submitted for zoning must comply with Arkansas Fire Prevention Code, 2021 Edition,
including any comments or requirements provided by the Little Rock Fire Marshals Office, prior to
acceptance.
Concur
Maintain Access:
1. Fire Hydrants
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant
is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Concur
2. Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol.1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade
except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and
the applicant must submit request to be reviewed by Fire Chief for Approval.
Concur
3. Loading
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol.1 Section D103.2.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access
road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load
of fire apparatus weighing at least 75,000 pounds.
Concur
Commercial and Industrial Developments-2 means of access. -Maintain fire apparatus access roads as
per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
1. Section D104.1 Buildings exceeding three stories or 30 feet in height
Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire
apparatus access for each structure.
Concur
3 | 4
2. Section D104.2 Building exceeding 62,000 square feet in area
Building or facilities having a gross building area of more than 62,000 square feet shall be provided with
two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler system.
Concur
3. D104.3 Remoteness
Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less
than one half of the length of the length of the maximum overall diagonal dimension of the lot or area to
be served, measured in a straight line between accesses.
Concur
30’ Tall Buildings-Maintain aerial Fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.4
1. D105.1 Where Required
Where the vertical distance between the grade plane and the highest roof surface exceeds 30’, approved aerial
fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces
shall be determined by measurement to the eave of the pitched roof, the intersection of a roof to the
exterior wall, or the top of the parapet walls, whichever is greater.
Concur
2. D105.2 Width
Aerial fire apparatus access roads shall have a minimum unobstructed with of 26’, exclusive of shoulders,
in the immediate vicinity of the building or portion thereof.
Concur
3. D105.3 Proximity to building
At least one of the required access routes meeting this condition shall be located within a minimum of 15
feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road is positioned shall be
approved by the fire code official.
Concur
4. D105.4 Obstruction
Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between
the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
Concur
Dead Ends
Maintain fore apparatus access roads at dead end locations as per Appendix D of the 2012
Arkansas Fire Protection Code Vol. 1 Section D103.4 Dead Ends.
Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround
provisions in accordance with Table D103.4 Requirements for Dead-end fire apparatus access roads.
Concur
Gates
Maintain Fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus
access roads shall comply with all of the following:
1. Minimum gate width shall be 20 feet.
Concur
2. Gates shall be of swinging or sliding type.
Concur
3. Construction of gates shall be of material that allow manual by one person.
Concur
4 | 4
4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when
defective.
Concur
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for
emergency access. Emergency opening devices shall be approved by the fire code official.
Concur
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of
being opened by means of forcible entry tools or when a key box containing the keys to the lock is
installed at the gate location.
Concur
7. Locking device specifications shall be submitted for approval by the fire code official.
Concur
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
Concur
9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with
requirements of ASTM F 2200.
Concur
LITTLE ROCK WATER RECLAMATION AUTHORITY (LRWRA) COMMENTS
No Comments
SUMMIT UTILITIES COMMENTS
No Comments
Thank you,
Davidson Engineering, PLLC
Jason Bouwknegt
Attached: