Loading...
HomeMy WebLinkAboutResponse to comments 031826 210 W. ARCH AVE., STE. D, SEARCY, AR 72143 | 501.388.2178 | DAVIDSONENGINEERS.COM March 18, 2026 Torrence Thrower City of Little Rock Planning & Development 723 W. Markham Street Little Rock, AR 72201 RE: Mabelvale ARcare Valley Oaks Court – Revised POD (Z – 47688 - E) 1349 McNutt Rd, Conway, AR Response to Comments receiver 3/13/2026 Mr. Torrence Thrower, In reference to your comments (response in blue): STAFF DEVELOPMENT COMMENTS 1. Proposed Lot 1RR must be developed as per the C-3 development criteria (building height, parking, landscaping, buffers, etc.). Concur 1. Building setbacks as shown on proposed replat are acceptable. Concur 2. Are C-3 permitted uses requested as alternate uses? Concur OTHER DEPARTMENTS COMMENTS CIVIL ENGINEERING 1. All documents are to be submitted to Planning and Development for complete plan check.. Concur 2. All documents shall be prepared by an Arkansas Licensed Professional Engineer. Concur 3. Land Survey to be no older than five (5) years. New survey submit on March 3, 2026 4. All documents shall be prepared based on the current Fire Prevention Codes, City of Little Rock Municipal codes and ordinances, and current City of Little Rock Master Street Plan. Concur 5. All streets to meet the current City of Little Rock Master Street Plan. Concur 6. Any new developments shall be reviewed to ensure all codes, specifications, and ordinances are met before issuing any related permits. Concur 2 | 4 PUBLIC WORKS ENGINEERING 1. Driveway locations and widths shall meet the traffic access and circulation requirements of Section 30-43 and 31-210. The width of the driveway must not exceed 40 feet; Concur 2. Storm water detention ordinance applies to this property. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/ or local property owners’ association and detailed in the bill of assurance. Concur LANDSCAPING REVIEW 1. Any new site development must comply with the City’s minimal landscape and buffer ordinance requirements. Refer to Code of Ordinances, Chapter 15 Landscaping and Tree Protection, and Chapter 36 IX – Buffers and Screening. Concur 2. Site Development plans, with landscaping and screening, must be submitted for review, and approval, prior to site clearing and tree removal. Concur LITTLE ROCK FIRE DEPARTMENT COMMENTS 1. Must Comply with Arkansas Fire Prevention Code 2021 edition All projects submitted for zoning must comply with Arkansas Fire Prevention Code, 2021 Edition, including any comments or requirements provided by the Little Rock Fire Marshals Office, prior to acceptance. Concur Maintain Access: 1. Fire Hydrants Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Concur 2. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval. Concur 3. Loading Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.1 Section D103.2.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Concur Commercial and Industrial Developments-2 means of access. -Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 1. Section D104.1 Buildings exceeding three stories or 30 feet in height Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Concur 3 | 4 2. Section D104.2 Building exceeding 62,000 square feet in area Building or facilities having a gross building area of more than 62,000 square feet shall be provided with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler system. Concur 3. D104.3 Remoteness Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. Concur 30’ Tall Buildings-Maintain aerial Fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.4 1. D105.1 Where Required Where the vertical distance between the grade plane and the highest roof surface exceeds 30’, approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of the pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. Concur 2. D105.2 Width Aerial fire apparatus access roads shall have a minimum unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof. Concur 3. D105.3 Proximity to building At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. Concur 4. D105.4 Obstruction Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Concur Dead Ends Maintain fore apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Protection Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4 Requirements for Dead-end fire apparatus access roads. Concur Gates Maintain Fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following: 1. Minimum gate width shall be 20 feet. Concur 2. Gates shall be of swinging or sliding type. Concur 3. Construction of gates shall be of material that allow manual by one person. Concur 4 | 4 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. Concur 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. Concur 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. Concur 7. Locking device specifications shall be submitted for approval by the fire code official. Concur 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. Concur 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Concur LITTLE ROCK WATER RECLAMATION AUTHORITY (LRWRA) COMMENTS No Comments SUMMIT UTILITIES COMMENTS No Comments Thank you, Davidson Engineering, PLLC Jason Bouwknegt Attached: