HomeMy WebLinkAboutZ-8987-A Floor Plans 050726Cross Section 1
WH WH
2854SH2854SH308030802854SH2854SH
2068 5068
28682660SH2660SH28682868286828682668 2668
2660SH2660SH28685068 5068
5068 2068
S1S1
CROSS SECTION 1 1'-0 1/2"2'-6"6'-9 1/2"6'-10 1/2"2'-6"11 1/2"16'16'-4"17'-5 1/2"
1'-6"
3'-10 1/4"3'-10 1/4"
1'-10"
1'-10"
16'-8 1/2"
2'-7"3'
12'-2"
16'-8 1/2"17'-9"
34'-5 1/2"6'-9 1/2"2'-6"1'-0 1/2"3'-4"10'-4"3'10'-4"16'4'-10 1/2"47'-10 1/2"4'-10 1/2"16'1'-0 1/2"2'-6"6'-9 1/2"4'-10 1/2"16'10'-4"3'10'-4"3'-4"47'-10 1/2"4'-10 1/2"3'-5 1/2"8'6'-5 1/2"5'-6 1/2"7'-10"3'-2"
34'-5 1/2"
5'-10" X 11'-2"
1482 SQ FT
10'-0" X 10'-0"
10'-0" X 10'-0"6'-0" X 15'-0"16'-4" X 15'-8"
6'-10" X 2'-8"
10'-0" X 10'-0"
16'-3" X 5'-0"16'-3" X 5'-0"
16'-4" X 15'-8"
7'-6" X 2'-8"6'-0" X 15'-0"5'-10" X 11'-2"10'-0" X 10'-0"
6'-10" X 2'-8"
7'-6" X 2'-8"
LIVING AREA
PATIO
DSH
WSHR
LAUNDRY
CENTER
LIVING
BEDROOM 2
BEDROOM 1
CLOSET BATHKITCHENPATIO
CLOSET
DSH
WSHR
LAUNDRY
CENTER
CLOSET
BEDROOM 1
BATH
KITCHENCLOSET
BEDROOM 2
LIVING
SSSSS1S1
CROSS SECTION 1
34'-5 1/2"
34'-5 1/2"
34'-5 1/2"
34'-5 1/2"43'5'-0 1/4"48'-0 1/4"43'33'-2" X 4'-4"
PATIO
DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:2/5/20261504 Hanger StAREAS
HEATED/COOLED
FRONT PORCH
TOTAL
FOUNDATION
1,482 / 741
180 / 90
1,662 SQ FT
1st Floor Plan
1/4" = 1'
Floor Plan Notes
1.ALL EXTERIOR DIMENSIONS
ARE TO THE MAIN LAYER.
DIMENSIONS TO OPENINGS
ARE TO THE FRAMING,
ROUGH OPENING. INTERIOR
DIMENSIONS ARE TO THE
FINISHED WALL.
2.CONTRACTOR SHALL
VERIFY ALL DIMENSIONS
AND IS RESPONSIBLE FOR
ALL DIMENSIONS
(INCLUDING ROUGH
OPENINGS).
3.GROUND SHOULD BE
CHEMICALLY TREATED FOR
TERMITE PROTECTION Floor / Foundation PlanSHEET:P-2Orndorff ConstructionF ire Wall Specification
1/4" = 1'
2 layers 5/8" Type X
1 Hour Gypsum Board
2x4 Wood Studs, Batt Insulation
5/8" Type X Gypsum Board
2 layers 5/8" Type X
1 Hour Gypsum Board
2x4 Wood Studs, Batt Insulation
5/8" Type X Gypsum Board
Foundation Plan
SLAB WI TH FOOTERS 1/4" = 1'
FOUNDATION NOTES
1.FOUNDATIONS TO BEAR A MINIMUM OF 16” BELOW FINISH GRADE
2.ALL ANCHOR BOLTS TO BE 5/8” DIA X 10 @ 32” O/C UNO.
3.ALL REINFORCING STEEL SHALL BE ASTM A-615, GRADE 60.
4.ALL REINFORCING STEEL TO OVERLAP A MINIMUM OF 24” FOR SPLICES.
5.PROVIDE CORNER BARS TO MATCH CONTINUOUS STEEL.
6.MINIMUM ALLOWABLE CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI AT 26 DAYS. MAXIMUM
AGGREGATE SIZE IS 1”. MAXIMUM AIR ENTRAINMENT IS 3%. CEMENT SHOULD BE TYPE 1 OR 2.
7.SOIL BEARING CAPACITY ASSUMED TO BE 1500 PSF (UBC TYPE 4 SOIL). IF SOIL CONDITIONS VARY FROM
THIS, THE PROJECT ENGINEER MUST BE NOTIFIED. ALL FOOTINGS MUST BEAR ON UNDISTURBED SOIL. ALL
SLOPES MUST BE STABILIZED.
8.ADJACENT GROUND SURFACES SHALL BE SLOPED AWAY FROM STRUCTURE DRAINAGE OF SURROUNDING
AREA SHALL ALSO BE PROVIDED TO PREVENT ACCUMULATION OF SOIL AND EROSION OF SOIL NEAR
FOOTINGS.
9.UNIFORM SOIL CONDITIONS, MUST BE PROVIDED UNDER SLAB AND FOOTINGS. CUT/FILL OR NON-
UNIFORM SOIL CONDITIONS SHOULD BE EXCAVATED AND REPL ACED W/ UNIFORM ENGINEERED FILL
MATERIAL TO MINIMIZE DIFFERENTIAL MOVEMENT.
10.THE TOPS OF FOUNDATION WALLS SHALL EXTEND 6” ABOVE THE ADJACENT FINISH GRADE
11.MINIMUM 18” CLEARANCE FOR WOOD JOIST GIRDERS REQUIRED IN THE CRAWL SPACE UNLESS TREATED
WOOD IS USED THROUGHOUT FLOOR SYSTEM
MASONRY NOTES
1.ALL CONCRETE MASONRY UNITS TO BE L AID IN CONFORMANCE WITH ASTM C90.
2.CONCRETE MASONRY UNITS TO BE LAID IN TYPE ‘S’ OR TYPE ‘M’ MORTAR IN A RUNNING BOND PATTERN.
MORTAR, GROUT AND REINFORCEMENT TO BE IN COMPLIANCE WITH CURRENT CODES.
3.COMPRESSIVE STRESS OF GROUT TO BE: FM’=2500 PSI. ALL CELLS TO BE FULLY GROUTED.
4.ALL REINFORCING STEEL TO BE: ASTM-A-615, GRADE 60.
Typical Slab Section
FIRE WALL TO CONTINUE
THROUGH ATTIC TO ROOF
SHEATHING, INCLUDING
PORCH