Loading...
HomeMy WebLinkAboutZ-8987-A Floor Plans 050726Cross Section 1 WH WH 2854SH2854SH308030802854SH2854SH 2068 5068 28682660SH2660SH28682868286828682668 2668 2660SH2660SH28685068 5068 5068 2068 S1S1 CROSS SECTION 1 1'-0 1/2"2'-6"6'-9 1/2"6'-10 1/2"2'-6"11 1/2"16'16'-4"17'-5 1/2" 1'-6" 3'-10 1/4"3'-10 1/4" 1'-10" 1'-10" 16'-8 1/2" 2'-7"3' 12'-2" 16'-8 1/2"17'-9" 34'-5 1/2"6'-9 1/2"2'-6"1'-0 1/2"3'-4"10'-4"3'10'-4"16'4'-10 1/2"47'-10 1/2"4'-10 1/2"16'1'-0 1/2"2'-6"6'-9 1/2"4'-10 1/2"16'10'-4"3'10'-4"3'-4"47'-10 1/2"4'-10 1/2"3'-5 1/2"8'6'-5 1/2"5'-6 1/2"7'-10"3'-2" 34'-5 1/2" 5'-10" X 11'-2" 1482 SQ FT 10'-0" X 10'-0" 10'-0" X 10'-0"6'-0" X 15'-0"16'-4" X 15'-8" 6'-10" X 2'-8" 10'-0" X 10'-0" 16'-3" X 5'-0"16'-3" X 5'-0" 16'-4" X 15'-8" 7'-6" X 2'-8"6'-0" X 15'-0"5'-10" X 11'-2"10'-0" X 10'-0" 6'-10" X 2'-8" 7'-6" X 2'-8" LIVING AREA PATIO DSH WSHR LAUNDRY CENTER LIVING BEDROOM 2 BEDROOM 1 CLOSET BATHKITCHENPATIO CLOSET DSH WSHR LAUNDRY CENTER CLOSET BEDROOM 1 BATH KITCHENCLOSET BEDROOM 2 LIVING SSSSS1S1 CROSS SECTION 1 34'-5 1/2" 34'-5 1/2" 34'-5 1/2" 34'-5 1/2"43'5'-0 1/4"48'-0 1/4"43'33'-2" X 4'-4" PATIO DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:2/5/20261504 Hanger StAREAS HEATED/COOLED FRONT PORCH TOTAL FOUNDATION 1,482 / 741 180 / 90 1,662 SQ FT 1st Floor Plan 1/4" = 1' Floor Plan Notes 1.ALL EXTERIOR DIMENSIONS ARE TO THE MAIN LAYER. DIMENSIONS TO OPENINGS ARE TO THE FRAMING, ROUGH OPENING. INTERIOR DIMENSIONS ARE TO THE FINISHED WALL. 2.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). 3.GROUND SHOULD BE CHEMICALLY TREATED FOR TERMITE PROTECTION Floor / Foundation PlanSHEET:P-2Orndorff ConstructionF ire Wall Specification 1/4" = 1' 2 layers 5/8" Type X 1 Hour Gypsum Board 2x4 Wood Studs, Batt Insulation 5/8" Type X Gypsum Board 2 layers 5/8" Type X 1 Hour Gypsum Board 2x4 Wood Studs, Batt Insulation 5/8" Type X Gypsum Board Foundation Plan SLAB WI TH FOOTERS 1/4" = 1' FOUNDATION NOTES 1.FOUNDATIONS TO BEAR A MINIMUM OF 16” BELOW FINISH GRADE 2.ALL ANCHOR BOLTS TO BE 5/8” DIA X 10 @ 32” O/C UNO. 3.ALL REINFORCING STEEL SHALL BE ASTM A-615, GRADE 60. 4.ALL REINFORCING STEEL TO OVERLAP A MINIMUM OF 24” FOR SPLICES. 5.PROVIDE CORNER BARS TO MATCH CONTINUOUS STEEL. 6.MINIMUM ALLOWABLE CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI AT 26 DAYS. MAXIMUM AGGREGATE SIZE IS 1”. MAXIMUM AIR ENTRAINMENT IS 3%. CEMENT SHOULD BE TYPE 1 OR 2. 7.SOIL BEARING CAPACITY ASSUMED TO BE 1500 PSF (UBC TYPE 4 SOIL). IF SOIL CONDITIONS VARY FROM THIS, THE PROJECT ENGINEER MUST BE NOTIFIED. ALL FOOTINGS MUST BEAR ON UNDISTURBED SOIL. ALL SLOPES MUST BE STABILIZED. 8.ADJACENT GROUND SURFACES SHALL BE SLOPED AWAY FROM STRUCTURE DRAINAGE OF SURROUNDING AREA SHALL ALSO BE PROVIDED TO PREVENT ACCUMULATION OF SOIL AND EROSION OF SOIL NEAR FOOTINGS. 9.UNIFORM SOIL CONDITIONS, MUST BE PROVIDED UNDER SLAB AND FOOTINGS. CUT/FILL OR NON- UNIFORM SOIL CONDITIONS SHOULD BE EXCAVATED AND REPL ACED W/ UNIFORM ENGINEERED FILL MATERIAL TO MINIMIZE DIFFERENTIAL MOVEMENT. 10.THE TOPS OF FOUNDATION WALLS SHALL EXTEND 6” ABOVE THE ADJACENT FINISH GRADE 11.MINIMUM 18” CLEARANCE FOR WOOD JOIST GIRDERS REQUIRED IN THE CRAWL SPACE UNLESS TREATED WOOD IS USED THROUGHOUT FLOOR SYSTEM   MASONRY NOTES 1.ALL CONCRETE MASONRY UNITS TO BE L AID IN CONFORMANCE WITH ASTM C90. 2.CONCRETE MASONRY UNITS TO BE LAID IN TYPE ‘S’ OR TYPE ‘M’ MORTAR IN A RUNNING BOND PATTERN. MORTAR, GROUT AND REINFORCEMENT TO BE IN COMPLIANCE WITH CURRENT CODES. 3.COMPRESSIVE STRESS OF GROUT TO BE: FM’=2500 PSI. ALL CELLS TO BE FULLY GROUTED. 4.ALL REINFORCING STEEL TO BE: ASTM-A-615, GRADE 60.   Typical Slab Section FIRE WALL TO CONTINUE THROUGH ATTIC TO ROOF SHEATHING, INCLUDING PORCH