HomeMy WebLinkAboutZ-7648-A Staff Report 020226February 12, 2026
ITEM NO.: 7 FILE NO.: Z-7648-A
NAME: Two Moon Properties, LLC – PD-R
LOCATION: SWC of Charles Bussey Avenue & Park Lane
DEVELOPER:
Downtown Little Rock Community Development Corporation/Two Moon Properties, LLC
8610 Crofton Circle
Little Rock, AR 72209
SURVEYOR/ENGINEER:
GarNat Engineering, LLC (Agent)
P.O. Box 116
Benton, AR 72018
AREA: 0.46 acre NUMBER OF LOTS: 4 FT. NEW STREET: 0 LF
CURRENT ZONING: R-4
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is proposing to rezone subject property form R-4 to PD-R to allow
for the development of seven (7) residential units. The property is comprised of
Lots A, 6 and 7, Block 404, Lincoln & Zimmerman Addition.
B. EXISTING CONDITIONS:
Subject property contains a mixture of zoning and uses in all directions.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS (PLANNING):
1. Any new development shall be permitted and receive all reviews to ensure all
codes, specifications, and ordinances are met.
2. Not enough onsite parking.
3. Proposed dimensions of the shared easement do not properly add up.
February 12, 2026
ITEM NO.: 7 (Cont.) FILE NO.: Z-7648-A
2
4. Applicant to show onsite location of fire hydrant and proposed fire hydrant if
required by LRFD as each lot is 150 ft in depth.
5. The proposed site plan does not show emergency vehicle circulation plan.
Please provide LRFD approved plan.
ENGINEERING COMMENTS (PUBLIC WORKS):
1. A width of at least 20 ft must be provided for 2-way traffic for the proposed
interior driveways accessing the residential structures.
2. A 20 feet radial dedication of right-of-way is required at the intersection of
Charles Bussey St. and Park Lane.
3. Park Lane is classified on the Master Street Plan as a residential street. A
dedication of right-of-way 25 feet from centerline will be required.
4. Repair or replace any curb, gutter, sidewalk and access ramps that are
damaged and not in compliance with ADA recommendations in the public right-
of-way prior to occupancy.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of the request for
water must be met.
Fire Department:
Must Comply with Arkansas Fire Prevention Code 2021 edition
All projects submitted for zoning approval must comply with the Arkansas
Fire Prevention Code, 2021 Edition, including any comments or
requirements provided by the Little Rock Fire Marshal's Office, prior to
acceptance.
February 12, 2026
ITEM NO.: 7 (Cont.) FILE NO.: Z-7648-A
3
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with asphalt, concrete or other approved driving surface capable of
supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Parks and Recreation: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
Land Use Plan:
The request is in Planning District 8, the Central City Planning District. The
development principles of this district include strengthening the existing
development and better define single-family and non-residential use areas by
neighborhood oriented commercial uses. The Land Use Plan shows Residential
Low Density (RL) for the application area. The Residential Low Density (RL)
category provides for single family homes at densities not to exceed 6 dwelling
February 12, 2026
ITEM NO.: 7 (Cont.) FILE NO.: Z-7648-A
4
units per acre. Such residential development is typically characterized by
conventional single family homes but may also include patio or garden homes and
cluster homes, provided that the density remains less than 6 units per acre. The
application is for a PD-R.
Surrounding the application area are areas designated for Residential Low Density
(RL) uses and area characterized by single-family residences. To the west along
Commerce Street is area designated for Mixed Use (MX) uses and is characterized
by single-family residences, a duplex, and office buildings.
This site is not located in an Overlay District.
Master Street Plan:
E. Charles Bussey Avenue and Park Lane are Local Streets on the Master Street
Plan. Local Streets are roads designed to provide access to adjacent property with
the movement of traffic being a secondary purpose. The standard Right-of-way is
50’. Sidewalks are required on one side. This street may require dedication of right-
of-way and may require street improvements.
Bicycle Plan:
E. Charles Bussey Avenue and Park Lane is not shown on the Master Bike Plan
with existing or proposed facilities in this area.
Historic Preservation Plan:
The property is approximately 340’ away from the William Laporte Building. William
Laporte escaped slavery in the South and returned to Arkansas in 1870. He was
a prominent bricklayer, plasterer, businessman, and politician. Laporte built this
building, a two-story brick masonry commercial cornerstore, circa 1899 to 1990.
The building was saved from demolition in 2014 and listed on the National Register
of Historic Places on 5/19/23.
The Historic Preservation Plan advocates for increased effectiveness and
coordination with the review of development plans. Staff advocates that the
proposed rehabilitation of the site to accommodate a new use consider its potential
adverse impacts to the site and adjacent historic sites. Staff finds the proposed
use will not adversely affect the existing historic fabric and context of the area if
changes are sensitively implemented and follow national preservation
standards. The application, as shown, should have no effect on identified historic
resources beyond the alterations already performed.
February 12, 2026
ITEM NO.: 7 (Cont.) FILE NO.: Z-7648-A
5
H. ANALYSIS:
The applicant is proposing to rezone subject property form R-4 to PD-R to allow
for the development of seven (7) residential units. The property is comprised of
Lots A, 6 and 7, Block 404, Lincoln & Zimmerman Addition.
The applicant proposes to subdivide all of Lots A & 7, Block 404, Lincoln &
Zimmerman Subdivision into three (3) lots, with a single-family dwelling on each
lot. The proposed Lots A-C are shown to be fifty (50) feet wide and approximately
seventy-eight (78) feet deep, ranging from approximately 3,822 square feet to
4,301 square feet in area. Lot 6 dimensions are shown as fifty (50) feet wide by
one-hundred-fifty (150) feet deep, or 7,500 square feet in area.
A twenty (20) foot wide shared driveway extending from E. 20th Street provides
access to the development. The shared driveway tapers to approximately fifteen
(15) feet onto the property and will provide parking in the rear for each residence.
The overall development will contain a 2,372 square foot quadplex building or two
(2), 1,295 square foot duplex structures in the western portion of the development
on Lot 6, and three (3) single-family residences in the eastern portion of the
development on the proposed Lots A-C. Each single-family residence will be
approximately one thousand (1,000) square feet in area.
Lot 6 shall have developable areas as depicted within the setbacks as depicted in
the replat; however, any dwelling constructed shall be no closer than five (5) feet
to the shared drive within the access easement, as built. Within the developable
area of Lot 6, up to four (4) dwelling units may be constructed in any configuration,
as so as one (1) off-street parking space is provided for each dwelling unit. Other
uses shall be permitted on Lot 6 as provided by Code. Other area regulations and
siting standards shall govern all lots within the replat.
The homes will be constructed using asphalt shingle roof and clad siding with brick
accents, including covered front and rear porches. The two (2) duplexes or
quadplex will be constructed using asphalt shingles and clad roofing.
Section 36-502 of the City’s Zoning Ordinance typically requires a minimum of one
(1) off-street parking space per single-family home. The three (3) homes will have
rear loading garages and the quadplex or two (2) duplexes will utilize four (4) off-
street parking spaces constructed in the rear of the quadplex, or between the two
(2) duplexes. Typically, Section 36-502 of the City’s Zoning Ordinance requires
six (6) parking spaces for either Lot 6 configuration. On-street parking is allowed
along East 20th Street and Park Lane. Staff feels the parking for the overall
development is sufficient to serve the proposed use.
February 12, 2026
ITEM NO.: 7 (Cont.) FILE NO.: Z-7648-A
6
The proposed residences will utilize standard city trash collection.
The site plan does not show perimeter fencing. Any fence or wall erected must
comply with Section 36-516 of the City’s Zoning Ordinance. A screening fence will
be required along the west and south property lines of Lot 6.
The applicant is not requesting any signs at this time. Signage for any configuration
must comply with Section 36-551 of the City’s Zoning Ordinance (signs permitted
in residential one- and two-family zones).
Any site lighting for the overall development must be low-level and directed away
from adjacent properties.
Staff is supportive of the proposed PD-R rezoning. To staff’s knowledge,
there are no outstanding issues associated with this application. The
applicant met with Planning staff to resolve all technical issues noted during
the review of the application. Staff feels that the proposed increase in
density should have no adverse impact on the surrounding properties.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested PD-R rezoning, subject to
compliance with the comments and conditions outlined in paragraphs D and E,
and the staff analysis, of the agenda staff report.
STAFF UPDATE:
The applicant submitted a letter to Staff on December 15, 2025 requesting this
application be deferred to the February 12, 2026 agenda. Staff supports the
deferral request.
PLANNING COMMISSION ACTION: (JANUARY 8, 2026)
This item was deferred to the February 12, 2026 agenda at the request of the
applicant.