HomeMy WebLinkAbout061726 PC MinutesJune 11, 2026
ITEM NO.: 11 FILE NO.: S-867-E(11)
NAME: Lot 9, Tract 1 and Lots 1-6, Tract 3, Chenal Valley - Preliminary Plat
LOCATION: East side of Chenal Parkway, between La Marche Road and Chenal Valley
Drive
DEVELOPER:
Potlatch Deltic, LLC
2 Chenal Club Blvd.
Little Rock, AR 72223
OWNER/AUTHORIZED AGENT:
Deltic Real Estate, LLC - owner
Tim Daters - agent
SURVEYOR/ENGINEER:
White-Daters & Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 41.98 acres NUMBER OF LOTS: 7 FT. NEW STREET: 1,400 L.F.
WARD: 5
CURRENT ZONING: O-2, C-1 and C-3
VARIANCE/WAIVERS:
None requested
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to subdivide 41.98 acres of property into seven (7) lots for
future office and commercial development.
B. EXISTING CONDITIONS:
The property is currently undeveloped and mostly wooded.
June 11, 2026
ITEM NO.: 11 (Cont.) FILE NO.: S-867-E(11)
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property abutting the site and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS (PLANNING DIVISION):
1. All documents shall be prepared based on the current Arkansas Fire Prevention
Codes, City of Little Rock Municipal codes and ordinances, and current
Stormwater Management and Drainage Manual.
2. All streets to meet the current City of Little Rock Master Street Plan.
3. Any new development shall be reviewed to ensure all codes, specifications,
and ordinances are met before issuing any related permits.
ENGINEERING COMMENTS (PUBLIC WORKS):
1. The nose of the proposed median should not extend beyond the projection of
the back of existing sidewalk crossing the proposed street.
2. Due to the curvature of Chenal Valley Drive, provide a letter prepared by a
registered engineer certifying the intersection sight distance at the
intersection(s) comply with the latest version of the AASHTO Green Book
standards.
3. A franchise permit is required to be issued by the City of Little Rock for any
private improvements proposed to be placed within the right-of-
way, islands and medians.
4. The proposed Lamarche Road shall be constructed to the Master Street Plan
standards as a commercial collector with sidewalks on both sides.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: Submit Plans for sewer.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water: NO OBJECTIONS; All Central Arkansas Water
requirements in effect at the time of request for water service must be met.
June 11, 2026
ITEM NO.: 11 (Cont.) FILE NO.: S-867-E(11)
3
Fire Department:
Must Comply with Arkansas Fire Prevention Code 2021 edition
All projects submitted for zoning approval must comply with the Arkansas
Fire Prevention Code, 2021 Edition, including any comments or
requirements provided by the Little Rock Fire Marshal's Office
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus
access road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant
must submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in
height. Building or facilities exceeding 30 feet or three stories in height shall have
at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall
be provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that
have a single approved fire apparatus access road when all building are equipped
throughout with approved automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of
the maximum overall diagonal dimension of the lot or area to be served, measured
in a straight line between accesses.
June 11, 2026
ITEM NO.: 11 (Cont.) FILE NO.: S-867-E(11)
4
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30’, approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof surfaces
shall be determined by measurement to the eave of a pitched roof, the intersection
of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of 30
feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road is
positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road and
the building. Other obstructions shall be permitted to be places with the approval
of the fire code official.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the
2021 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus
access road gates. Gates securing the fire apparatus access roads
shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all
times and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
June 11, 2026
ITEM NO.: 11 (Cont.) FILE NO.: S-867-E(11)
5
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with UL
325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
Parks and Recreation: No comments received.
County Planning: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
Landscape: No comments received.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
Land Use Plan:
The request is in Planning District 19, the Chenal Planning
District. The development principles of the district include developing roads for all
modes of transportation, and the preservation of greenways, open spaces, and
significant environmental features. The Land Use Plan shows Office (O) and
Neighborhood Commercial (NC) for the application area. The Office (O) category
represents services provided directly to consumers (e.g., legal, financial, medical)
as well as general offices which support more basic economic activities. The
Neighborhood Commercial (NC) category includes limited small-scale commercial
development near a neighborhood, providing goods and services to that
neighborhood market area.
To the north of the application area is area designated for Office (O) uses and is
characterized by undeveloped woodlands and Little Rock Fire Station 21. East of
the application area is area designated for Residential High Density (RH) uses and
June 11, 2026
ITEM NO.: 11 (Cont.) FILE NO.: S-867-E(11)
6
is characterized by an apartment complex. South of the application area is
area designated for Commercial (C) uses and is characterized by a bank, a sit-
down restaurant, two strip office building, and a hotel. West of the application area,
across from Chenal Parkway, is area designated for Residential Low Density (RL)
and Park/Open Space (PK/OS) uses and are characterized by single -family
residences and the Chenal Country Club Golf Course.
The subject site is in the Chenal/Financial Center Design Overlay District (Ord.
16861). The purpose of the Chenal/Financial Center Design Overlay District is to
create a scenic parkway by removing utility infrastructure and by controlling
signage and lighting and to use the existing master street and land use plans to
ensure a well-designed corridor.
Master Street Plan:
Chenal Valley Drive is a Collector on the Master Street Plan. Collectors are
designed to connect traffic from Local Streets to Arterials or to activity centers, with
the secondary function of providing access to adjoining property. The standard
Right of way is 60’. Sidewalks are required on one side of Collectors. This street
may require dedication of right-of-way and may require street improvements.
Chenal Parkway is a Principal Arterial on the Master Street Plan. Principal Arterials
are roads designed to serve through traffic, and to connect major traffic generators
or activity centers within urbanized areas. The standard Right of way of 110 feet is
required. Sidewalks are required on both sides. This street may require dedication
of right-of-way and may require street improvements.
Bicycle Plan:
Chenal Valley Drive is on the Master Bike Plan as a Proposed Class III Bike Route.
Class III Bike Routes require no additional right -of-way, but either a sign or
pavement marking to identify and direct the route.
Chenal Parkway is on the Master Bike Plan as a Proposed Class I Bike Route.
Class I Bike Routes are routes designated for the sole use of bicycles that are
physically separated from vehicular lanes.
Historic Preservation Plan:
The application, as shown, should have no effect on identified historic resources.
H. ANALYSIS:
June 11, 2026
ITEM NO.: 11 (Cont.) FILE NO.: S-867-E(11)
7
The applicant proposes to subdivide 41.98 acres of property into seven (7) lots for
future office and commercial development. The property is zoned O-2, C-1 and C-
3. The property is located along the east side of Chenal Parkway, between La
Marche Road and Chenal Valley Drive. The property is currently undeveloped and
mostly wooded.
The applicant is proposing the following seven (7) lots:
Lot 9, Tract 1 - 7.91 acres (C-3)
Lot 1, Tract 3 - 2.92 acres (C-3)
Lot 2, Tract 3 - 2.87 acres (C-1 & C-3)
Lot 3, Tract 3 - 2.71 acres (C-1)
Lot 4, Tract 3 - 6.98 acres (C-1 & O-2)
Lot 5, Tract 3 - 7.52 acres (C-1 & C-3)
Lot 6, Tract 3 - 8.96 acres (O-2)
The remainder of LaMarche Road will be constructed between Chenal Parkway
and Chenal Valley Drive with this project. Several of the lots will have street
frontage along LaMarche Road and Chenal Valley Drive. There will be a private
street running between Lot 1, Tract 3 and Lot 5, Tract 3, which will serve as internal
cross-access between these lots.
All the proposed lots will have 25-foot building lines along the LaMarche Road and
Chenal Valley Drive frontages and 50-foot building lines along the Chenal Parkway
Frontage. All the proposed lots will conform with the minimum lot area and size
requirements found in Sections 36-280, 36-299 and 36-301 of the City's Zoning
Ordinance.
The applicant plans to grade the lots with the construction of LaMarche Road. This
will allow the balancing of the cuts and fills throughout the site. All required
stormwater/drainage information for a preliminary plat must be submitted to the
engineering division prior to a grading permit being issued.
Staff is supportive of the requested preliminary plat. The applicant is requesting
no variances with this request.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested preliminary plat, subject to
compliance with the comments and conditions outlined in paragraphs D and E,
and the staff analysis, of the agenda staff report.
June 11, 2026
ITEM NO.: 11 (Cont.) FILE NO.: S-867-E(11)
8
PLANNING COMMISSION ACTION: ( June 11, 2026 )
The applicant was present. There were no objectors present. The application was
placed on the Consent Agenda for approval as recommended by staff. There was
a motion to approve the Consent Agenda. The motion passed by a vote of 11 ayes, 0
nays, 0 absent. The application was approved.