HomeMy WebLinkAbout16. 061726 PC MinutesJune 11, 2026
ITEM NO.: 16 FILE NO.: Z-10308
NAME: Phillips Duplexes #2 – Conditional Use Permit
LOCATION: 3310 W. 12th Street
DEVELOPER:
Stanley Phillips
6204 Sandy Lane
Little Rock, AR 72206
OWNER/AUTHORIZED AGENT:
Catherine Shank (Owner)
Stanley Phillips (Agent)
SURVEYOR/ENGINEER:
Cunningham Surveying
2105 Lorance Drive
Little Rock, AR 72206
AREA: 0.48 acre NUMBER OF LOTS: 2 FT. NEW STREET: 0 LF
WARD: 1
CURRENT ZONING: R-3
VARIANCE/WAIVERS:
None requested.
______________________________________________________________________
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant requests a conditional use permit to allow for the construction of two
(2) duplex structures, one (1) on each of two (2) platted lots, zoned R-3, located at
3310 W. 12th Street.
B. EXISTING CONDITIONS:
The property is undeveloped and partially tree covered.
June 9, 2026
ITEM NO.: 16 (Cont.) FILE NO.: Z-10308
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS (PLANNING DIVISION):
1. All documents shall be prepared based on the current Arkansas Fire
Prevention Codes, City of Little Rock Municipal codes and ordinances, and
current Stormwater Management and Drainage Manual.
2. All streets to meet the current City of Little Rock Master Street Plan.
3. Any new development shall be reviewed to ensure all codes, specifications,
and ordinances are met before issuing any related permits.
ENGINEERING COMMENTS (PUBLIC WORKS): No comments.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
Fire Department:
All projects submitted for zoning approval must comply with the Arkansas
Fire Prevention Code, 2021 Edition, including any comments or
requirements provided by the Little Rock Fire Marshal's Office.
June 9, 2026
ITEM NO.: 16 (Cont.) FILE NO.: Z-10308
3
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with asphalt, concrete or other approved driving surface capable of
supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
Land Use Plan:
The request is in Planning District 9, the I-630 Planning District. The development
principles of this district are to preserve the residential character of the area and
isolate the non-residential use to specific locations without affecting adjacent
neighborhoods. The Land Use Plan shows Mixed Use (MX) for the application
area. The Mixed Use (MX) category provides for a mixture of residential, office and
June 9, 2026
ITEM NO.: 16 (Cont.) FILE NO.: Z-10308
4
commercial uses to occur. A Planned Zoning District is required if the use is entirely
office or commercial or if the use is a mixture of the three.
To the north of the application area is area designated for Residential Low Density
(RL) uses and is characterized by single-family dwellings interspersed with
duplexes. East, south, and west of the application area are areas designated for
Mixed Use (MX) uses and are characterized by single-family homes, small
apartment buildings, a two-part commercial block building, and a faith-based
institution.
This site is not located in an Overlay District.
Master Street Plan:
West 12th Street is a Minor Arterial on the Master Street Plan. Minor Arterials are
high volume roads designed to provide the connections to and through an urban
area. Curb cuts should be minimized to allow for continuous traffic flow while still
allowing some access to adjoining property. Deceleration Lanes are required.
Standard Right-of-way (ROW) is 90 feet. Sidewalks are required on both sides.
This street may require dedication of right-of-way and may require street
improvements.
Brown Street is a Local Street on the Master Street Plan. Local Streets are roads
designed to provide access to adjacent property with the movement of traffic being
a secondary purpose. The standard Right-of-way is 50’. Sidewalks are required on
one side. This street may require dedication of right-of-way and may require street
improvements.
Bicycle Plan:
West 12th Street is on the Master Bike Plan as an Existing Class II Bike Lane. Class
II Bike Lanes provides a portion of the pavement for the sole use of bicycles. Brown
Street is not shown on the Master Bike Plan with existing or proposed facilities in
this area.
Historic Preservation Plan:
The subject property is adjacen to the Owen B. Williams House and the State
Printing Company Buildng. Both structures are identified as being eligible for listing
to the National Regsiter of Historic Places.
The Historic Preservation Plan advocates for increased effectiveness and
coordination with the review of development plans. Staff advocates that the
proposed conversion of the site to accommodate a new use consider its potential
June 9, 2026
ITEM NO.: 16 (Cont.) FILE NO.: Z-10308
5
adverse impacts to adjacent historic sites. The application, as shown, should have
no effect on identified historic resources.
H. ANALYSIS:
The applicant requests a conditional use permit to allow for the construction of two
(2) duplex structures on R-3 zoned property located at 3310 W. 12th Street. The
property is comprised of two (2) platted lots; lots 9A and 9B, being a replat of Lot
9, Saxon’s addition. The applicant proposes a duplex on each lot. The property
ownership also includes a nineteen (19) foot wide sliver of land running from the
northeast corner of Lot 9B to Brown Street. This sliver of land was conveyed to the
owner of the property a number of years ago, to serve as access to the property,
as there is no vehicular access from W. 12th Street because of a retaining wall.
The property is currently undeveloped.
The proposed duplex structures will be located over fifty (50) feet from the front
(south) property lines, over forty (40) feet from the rear (north) property lines and
7.5 feet to10.7 feet from the side property lines.
A shared drive from Brown Street will serve as access to the development. An
access easement will be dedicated from Brown Street to Lot 9A. There will be four
(4) parking spaces located in the rear yard of each lot, with cross-access between
the lots. The number of parking spaces will comply with Section 36-502 of the
City’s Zoning Ordinance.
The description of the proposed duplexes was provided by the applicant as follows:
“The new units (2x attached units with four (4) separate tenants), approximately
2,348 sf each duplex units, shall be a two-story flat reinforced concrete slab;
thermal insulated wood-framed Structure; clad with vinyl siding, vinyl clad-thermal
glazed windows and a hip roof clad with asphalt shingles.”
Staff is in support of the requested Conditional Use Permit. The applicant is
requesting no variances. Staff believes the request is reasonable and that the
proposed duplexes are appropriate for this location.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested Conditional Use Permit, subject to
compliance with the comments and conditions outlined in paragraphs D and E,
and the staff analysis, of the agenda staff report.
June 9, 2026
ITEM NO.: 16 (Cont.) FILE NO.: Z-10308
6
PLANNING COMMISSION ACTION: (June 11, 2026)
The applicant was present. There were no objectors present. The application was
placed on the Consent Agenda for approval as recommended by staff. There was
a motion to approve the Consent Agenda. The motion passed by a vote of 11 ayes,
0 nays, 0 absent. The application was approved.