Loading...
HomeMy WebLinkAboutZ-7838-A Site Plan 01152625' VEHICULAR ACCESS &MAINTENANCE EASEMENTXXXXXXXX X X X X X X X X X X X X X X X X X X X XXXXXOHEOHEOHEOHEOHEO H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE X X XXXXUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTUGTOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE255 255 255 251252 253 254 256 256 256 257 257257 258 258258 259 259 259 250 250 255 260260 260260251 251 252253 254 256 257 258258258 259 2592 5 9 259 259MCDONALD'S BILLBOARD PARKING LOTUGT UGTUGTUGTUGTUGTUGTUGTUGTUGTCURB & GUTTER 258 TRACT 1 7.39 ACRES 322,109.09 SQ FT SEWER PUMP STATION ZONE "AE"(FLOODWAY)ZONE "AE" (WITH BFE OR DEPTH) ZONE "AE" (0.2% ANNUAL CHANCE FLOOD HAZARD)ZONE "AE"(WITH BFE OR DEPTH)36" CONCRETE PIPE UNIVERSITY AVENUE(R.O.W. VARIES)WWWWWWWWWWWWWWWP.O.B. CONCRETED SLOPE P.O.C. SW CORNER SECTION 18 T-1-N, R-12-W250250255255260251251252252253253254254256256257257258258259259259255256257258 255255255260260260260 256256256 257257257 258 25825 8 258259259259 25 9259 259250 255 251 252 253 254 256N08°45'14"E - 294.13' (M)S81°09'44"E - 3 1 0 . 5 1 ' ( M )N08°46'38"E - 243.99' (M)S5 2 ° 5 8 ' 1 1 " E - 5 1 7 . 1 3 ' ( M )S01°49'55"W - 299.84' (M)N88°39'05"W - 659.46' (M) L=174.96' (M), R=375.00' (M), 26.73° (M) CH=N49°59'21"W - 173.37' (M)2552542562572582592 5 8 258 2602602 5 7 2582 5 8 259259261261262262263S.S. MAIN EX. SSMH RIM EL = 251.64 APPROX. FL EL = 241.04 EX. SSMH APPROX. RIM EL = 252.55 APPROX. FL EL = 241.95 EX. SSMH RIM EL = 253.23 APPROX. FL EL = 242.43 Ssmh rim #272 ELEV=251.64111.5' POWER LINE EASEMENT15' UTILITY EASEMENT150' POWER LINE EASEMENTAPPROX. 20' SEWER EASEMENT75' x 120' OFFICE BUILDING FFE = 262' BLDG #1 C-3 C-3 R-2 C-3 SODDED DETENTION POND 2 25' REAR SETBACK 15' SIDE SETBACK25' FRONT S E T B A C K C-3 C-3 R-2 C-3 COMPACTED GRAVEL FOR RV/ TRAILER STORAGE 25' REAR SETBACK 15' SIDE SETBACK25' FRONT S E T B A C K 46.41'92 . 7 1 ' SODDED DETENTION POND 1 15' UTILITY EASEMENT 11 0 . 2 8 '59.63'30 . 4 3 ' 26 ' 26 ' X X X X XXXXXXXXXXXXXXXXXXXX X X X X XXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX31' 31 . 8 ' 26 ' PROPERTY LINE PROPERTY LINE TYP. CURB & GUTTER (2 TYP.) 3' FLUME FOR RELEASE OF SITE DRAINAGE INTO DETENTION POND 2 (6 TYP.) 2' CONCRETE SWALE DUMPSTER PAD NEW 5' SIDEWALK NEW 9' SIDEWALK ASPHALT PAVING NEW 5' SIDEWALK ASPHALT PAVING 4'-0 CURB CUT 4'-0 CURB CUT 2'-0 CURB CUT INSTALL (4) BOLLARDS FOR HYDRANT PROTECTION INSTALL (4) BOLLARDS FOR HYDRANT PROTECTION 2'-0 CURB CUT 6' SECURITY FENCE 6' SECURITY FENCE 2'-0" CURB CUT & FLUME ACCESS GATE WITH OPENER 2 5 ' 25' VE H I C U L A R A C C E S S & MAIN T E N A N C E E A S E M E N T 80' x 200' CLIMATE CONTROLLEDSTORAGE BUILDING FFE = 261.75'BLDG #230' x 200' STORAGE BUILDINGFFE = 261.75BLDG #340' x 200' STORAGEFFE = 261.25'BLDG #440' x 200' STORAGEFFE = 260.75'BLDG #540 ' x 1 6 0 ' S T O R A G E F F E = 2 6 0 . 5 0 ' B L D G # 6 40.62'27.33'26'114.14'TYP. CURB & GUTTER 12 PARKING SPACES 20 PARKING SPACES 7 PARKING SPACES6 P A R K I N G S P A C E S 6" THICK SUBGRADE COMPACTED TO 92% MODIFIED PROCTOR DENSITY 8" THICK CLASS 7 COMPACTED TO 95% STANDARD PROCTOR DENSITY COMPACTED GRAVEL PAVEMENT SURFACE DETAIL NOT TO SCALE NOT TO SCALEHMAC ASPHALT SURFACE COURSE DETAIL 3" OF ACHM SURFACE COURSE CONFORMING TO SECTION 407 OF ARDOT STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION, 1996 OR 2003 EDITION 8" THICK CLASS 7 (SB-2) CRUSHED STONE COMPACTED TO 98% MODIFIED PROCTOR DENSITY PROOFROLL SUBGRADE AFTER CUTTING TO GRADE, REMOVE ANY LOOSE, SOFT, OR UNSUITABLE MATERIALS ENCOUNTERED.COMPACT SUBGRADE TO 92% MODIFIED PROCTOR DENSITY OR AS DIRECTED OTHERWISE BY ENGINEER TO A MINIMUM DEPTH OF 8". CONCRETE APRON SECTION NOT TO SCALE 6" THCK CONCRETE DRIVE REINFORCED W/ W2.9XW2.9 SHEET MESH ONLY 6" THICK SUBGRADE COMPACTED TO 92% MODIFIED PROCTOR DENSITY 6" THICK CLASS7 COMPACTED TO 95% MODIFIED PROCTOR DENSITY MAXIMUM RUNNING MAXIMUM CROSS SLOPE IS 2%. SLOPE IS 5%. 4" CONCRETE SLAB/BRUSH FINISH W/6 x 6 - W1.4 x W1.4 SHEET MESH ONLY ON 2" HI SAND CHAIRS @ 3' ON CENTER MAX, OVER 6" TH'K SUBGRADE COMPACTED TO 95% MODIFIED PROCTOR DENSITY NOT TO SCALE 5'-0" (TYPICAL) CONCRETE WALK SECTION NOTE: ALL SIDEWALK JOINTS TO BE STEEL TROWELED. ALL JOINT EDGES AND SHALL BE SPACED AT 5 FEET ON CENTER MAXIMUM IN ALL DIRECTIONS AND SHALLBE STEEL TROWELED ON A RADIUS NOT TO EXCEED ONE-HALF INCH. PAVEMENT DIMENSIONS REFER TO THIS POINT VARIABLE DEPTH CLASS 7 (SB-2) CRUSHED STONE COMPACTED TO 95% STANDARD PROCTORDENSITY CONFORMING TO SECTION 303 OF THE (AHTD) STANDARD SPECIFICATIONS FOR HIGHWAY CONST'N IMPORT FILL MIN 2' - 6" REFERENCE GEOGRAPHIC REPORT 6" THICK COMPACTED STONE SUBGRADE TO MATCH ADJIONING PAVING SUBGRADE FINISH GRADE NOTE: ALL CURBING TO BE 3500 PSI 28 DAY CONCRETE VARIABLE THICKNESS3500 PSI CONCRETE OR ASPHALT (SEE PLAN AND DETAILS THIS SHEET) NOT TO SCALE2'-0" CONCRETE CURB & GUTTER 1'-4" 2" 6".5" 6" 1'-0" 6" 3 " 2'-0" 2"1 13/16"1 1/4" 3 1/2"18"CONCRETE 4 LB/FT "U"CHANNEL (GALVANIZED) SIGN NUT AND LOCK WASHER 5/16" MACHINE SCREW OR BOLT SIDEWALK OR FIN. GRADE POST MOUNTING POST SECTION PARTIAL ELEVATION1"36" - 3/8"6"HOLES PUNCHED@ 1'-0" ON CENTERNOT TO SCALEHANDICAP SIGN DETAIL NOTE: HANDICAP SIGNAGE SHALL BE IN STRICT COMPLIANCE WITH CURRENT FEDERAL AND LOCAL LAW REQUIREMENTS ACCESSIBLE PARKING STALL SIGN POST W/ ACCESSIBILITY SYMBOL & "VAN ACCESSIBLE" SIGN MOUNTED BELOW. (VAN ACCESSIBLE SIGN NOT REQ'D. W/ MIN. 8' STRIPED AISLE) WHEELSTOP (SEE DETAIL) FACE OF CURB 4" PAINTED STRIPING 1'-6" O.C. AT 45° (WHITE REFLECTIVE) PAVEMENT MAX. SLOPE 2% IN ALL DIRECTIONS. 5.00' 20.00' VAN ACCESSIBLE PARKING STALL 9.50'11.00' NOT TO SCALE CONCRETE FLUME DETAIL NOT TO SCALE 6"VARIES 6" VARIES 4" 1'-0" CONCRETE FLUME W/ #3 BARS @ 12" O.C., EACHWAY 6" 0 40' 1" = 40'-0" SITE PLAN SCALE 1" = 40' OVERALL SITE PLAN C1.1 SHEET NUMBER: PROJECT NUMBER: REVISION: PAGE TITLE: SHEET ISSUE DATE:PHILLIP LEWIS ENGINEERING, INC.Structural + Civil Consultants23620 Interstate 30 | Bryant, ArkansasPH: 501-350-984012/18/2025 ENGINEER L TS EAT OF ARKANSAS REGISTERED PROFESSIONAL No. 9540 P H IL A.LIP E W ISNEW CLIMATE CONTROLLED STORAGE PARKING LOT STANDARD SPACES PROVIDED ADA SPACES PROVIDED TOTAL SPACES PROVIDED 42 3 (1 VAN ACCESS)45 1. TOTAL NEW DEVELOPMENT AREA = (+/-) 7.40 ACRES 2. ALL DIMENSIONS ARE TO THE BACK OF CURB AND/OR EDGE OF PAVEMENT 3. ALL SETBACKS TO MEET CITY OF LITTLE ROCK STANDARDS 4. DAMAGE TO PUBLIC AND PRIVATE PROPERTY DUE TO HAULING OPERATIONS OR OPERATIONS OF CONSTRUCTION RELATED EQUIPMENT FROM A CONSTRUCTION SITE SHALL BE REPAIRED BY THE THE RESPONSIBLE PARTY PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 5. REPAIR, REPLACE, OR EXTEND EXISTING DAMAGED OR MISSING CURB AND GUTTER, SIDEWALK OR RAMPS WITHIN THE PUBLIC RIGHT OF WAY. 6. ALL SIGNAGE, PAVEMENT MARKING AND PARKING LOT STRIPING SHALL CONFORM TO REQUIREMENTS GIVEN IN MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). MUTCD REQUIRES THAT PARKING SPACES BE MARKED IN WHITE.BENBRAN STORAGE4301S UNIVERSITY AVENUENOTE: PROVIDE AN UNDERCUT ALLOWANCE (IN BASE BID) OF 750 CUBIC YARDS (UNDERCUT & REPLACEMENT AS/IF REQUIRED) AT A UNIT BID PRICE OF #___ / CUBIC YARDS. UNIT PRICE WILL BE USED FOR QUANTITIES OVER OR UNDER THE ALLOWANCE STATED ABOVE. UNIT BID PRICE SHALL INCLUDE REMOVAL & REPLACEMENT OF ANY UNSUITABLE MATERIALS (TO BE DETERMINED ON A CROSS-SECTIONAL MEASUREMENT BASIS). GENERAL CONSTRUCTION NOTES A. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR DAMAGES OCCURRING TO ANY PROPERTY DURING THE CONSTRUCTION OF THIS PROJECT. SAID CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT PROPERTY DAMAGE. B. DAMAGE TO PUBLIC AND PRIVATE PROPERTY DUE TO HAULING OPERATIONS OR OPERATIONS OF CONSTRUCTION RELATED EQUIPMENT FROM A CONSTRUCTION SITE SHALL BE REPAIRED BY THE THE RESPONSIBLE PARTY PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. C. REPAIR, REPLACE, OR EXTEND EXISTING DAMAGED OR MISSING CURB AND GUTTER, SIDEWALK, RAMPS, OR CONCRETE APRONS WITHIN THE PUBLIC RIGHT-OF-WAY PRIOR TO CONSTRUCTION SHALL CONFORM TO CITY OF LITTLE ROCK STANDARD DETAILS AND ADA GUIDELINES. D. CONTACT CITY OF LITTLE ROCK STREET DEPARTMENT FOR INSPECTION OF ANY WORK IN PUBLIC RIGHT-OF-WAY PRIOR TO PLACEMENT OF CONCRETE OR ASPHALT OR FOR ON-SITE CLARIFICATION OF REQUIREMENTS PRIOR TO COMMENCING WORK, FAILURE TO DO SO CAN RESULT IN REMOVAL OF ANY IMPROPERLY PLACED CONCRETE OR ASPHALT AT THE EXPENSE OF THE OWNER OR OR CONTRACTOR. E. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL SOLELY AND COMPLETELY BE RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND WILL NOT BE LIMITED TO NORMAL WORKING HOURS. F. ANY AND ALL UTILITY IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST REVISION TO EACH UTILITY PROVIDER'S STANDARD SPECIFICATIONS. G. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF ALL UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. H. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM PREVIOUS AND CURRENT DEMOLITION OPERATIONS. DISPOSAL WILL BE IN ACCORDANCE WITH ALL LOCAL, STATE AND/OR FEDERAL REGULATIONS GOVERNING SUCH OPERATIONS. I. PRIOR TO INSTALLATION OF ANY UTILITIES, THE CONTRACTOR IS TO EXCAVATE, ANY CONFLICTS PRIOR TO CONSTRUCTION. J. FIBER OPTIC CABLE ON AND/OR ADJACENT TO THIS SITE WERE NOT LOCATED BY THE SURVEY AND ARE NOT SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ANY FIBER OPTIC CABLES ASSOCIATED WITH THIS SITE AND TAKE ALL NECESSARY AND REQUIRED PRECAUTIONS TO PROTECT ANY EXISTING FIBER OPTIC CABLES. CONTRACTORS SHALL COORDINATE ALL EFFORTS WITH OWNER OF FIBER OPTIC CABLES OR THEIR DESIGNATED REPRESENTATIVE. K. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING "ONECALL" SERVICE TO MARK ALL UTILITIES PRIOR TO ANY DEMOLITION, EARTHWORK, OR UTILITY WORK ON THIS SITE. Z-7838-A