HomeMy WebLinkAboutZ-10281 Staff Report 032826April 9, 2026
ITEM NO.: 14 FILE NO.: Z-10281
NAME: Rezoning from R-2 to I-2 & OS
LOCATION: 7600 Block of Jamison Road (east side)
OWNER/AUTHORIZED AGENT:
AXC, LLC
7 Gatewood Cove
Little Rock, AR 72206
AREA: 4.08 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 2
CURRENT ZONING: R-2
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The owner of the 4.08 acre property located in the7600 block of Jamison Road
(east side) is requesting that the property be rezoned from “R-2” Single-Family
District, to “I-2” Light Industrial District and “OS” Open Space District.
B. EXISTING CONDITIONS:
The property is undeveloped and mostly wooded.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS (PLANNING DIVISION): No comments.
ENGINEERING COMMENTS (PUBLIC WORKS):
1. Due to the proposed use of the property, the Master Street Plan specifies that
Jamison Road for the frontage of this property must meet commercial street
standards. Dedicate right-of-way to 30 feet from centerline.
April 9, 2026
ITEM NO.: 14 (Cont.) FILE NO.: Z-10281
2
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
Fire Department:
Must Comply with Arkansas Fire Prevention Code 2021 edition
All projects submitted for zoning approval must comply with the Arkansas
Fire Prevention Code, 2021 Edition, including any comments or
requirements provided by the Little Rock Fire Marshal's Office, prior to
acceptance.
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
April 9, 2026
ITEM NO.: 14 (Cont.) FILE NO.: Z-10281
3
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with asphalt, concrete or other approved driving surface capable of
supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height.
Buildings or facilities exceeding 30 feet or three stories in height shall have at least
two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provided with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
buildings are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceeds 30’, approved aerial fire apparatus
access roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever
is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a maximum
of 30 feet from the building and shall be positioned parallel to one entire side of the
April 9, 2026
ITEM NO.: 14 (Cont.) FILE NO.: Z-10281
4
building. The side of the building on which the aerial fire apparatus access road is
positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located
over the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be placed with the
approval of the fire code official.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
Landscape:
1. Any new site development must comply with the City’s minimal landscape and
buffer ordinance requirements. Refer to the Code of Ordinances, Chapter 15
Landscaping and Tree Protection, and Chapter 36, Article IX – Buffers and
Screening.
2. Site development plans, with landscape and screening, must be submitted for
review, and approval, prior to site clearing and tree removal.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
Land Use Plan:
The request is in Planning District 14, the Geyer Springs East Planning District.
The development principles of this district include protection and stabilization of
existing neighborhoods and limit commercial strip development along major roads.
The Land Use Plan shows Industrial (I) for the application area. The Industrial (I)
category encompasses a wide variety of manufacturing, warehousing research
and development, processing, and industry related office and service activities.
Industrial development typically occurs on an individual tract basis rather than
according to an overall development plan. The application is for a Rezoning from
R-2 to I-2 and OS.
To the east of the application area is area designated for Park/Open Space
(PK/OS) and is characterized by the Little Fourche Creek and its floodway. North
and west of the application area are areas designated for Industrial (I) uses and
are characterized by industrial storage facilities, a supply store, transportation
companies, strip office buildings, manufacturing plants, distribution centers,
April 9, 2026
ITEM NO.: 14 (Cont.) FILE NO.: Z-10281
5
industrial sales, and other commercial uses. South of the application area is area
designated for Public/institutional (P/I) uses and is characterized by City of Little
Rock Fleet Services, Public Works, and Building Services buildings.
This site is not located in an Overlay District.
Master Street Plan:
Jamison Road is a Local Street on the Master Street Plan. Local Streets are roads
designed to provide access to adjacent property with the movement of traffic being
a secondary purpose. The standard Right-of-way is 50’. Sidewalks are required on
one side. This street may require dedication of right-of-way and may require street
improvements.
Bicycle Plan:
Jamison Road is not shown on the Master Bike Plan with existing or proposed
facilities in this area.
Historic Preservation Plan:
The application, as shown, should have no effect on identified historic resources.
H. ANALYSIS:
The owner of the 4.08 acre property located in the7600 block of Jamison Road
(east side) is requesting that the property be rezoned from “R-2” Single-Family
District, to “I-2” Light Industrial District and “OS” Open Space District.
The property is undeveloped and mostly wooded.
The applicant proposes to rezone the property as follows:
• West 1.38 acres – from R-2 to I-2
• East 2.70 acres (floodway) – from R-2 to OS
The property is designated as “I” Industrial and “PK/OS” on the City’s Future Land
Use Plan. The proposed rezoning will not require an amendment to the plan.
Staff is supportive of the requested I-2 and OS zoning. The proposed rezoning will
represent a continuation in the zoning pattern for this area along Jamison Road.
The properties immediately north and south, as well as across Jamison Road are
currently zoned I-2.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested I-2 and OS zoning.