HomeMy WebLinkAbout200201023 MMECHANICAL PERMIT
CITY OF LITTLE ROCK
DEPARTMENT OF
PLANNING AND DEVELOPMENT
BUILDING CODES DIVISION
PERMIT NUMBER:200201023
ISSUE DATE: 02/05/02
EXPIRATION DATE: 02/05/03
PERMISSION IS HEREBY GIVEN TO:
CONTRACTOR: CHENAL HEATING & A/C* OWNER:
TO PERFORM THE FOLLOWING WORK:
NATURE OF WORK:
CLASS OF WORK: NEW VALUATION: 0 SQ FT: 3,358
JOB DESCRIPTION: 3BED,2.5BATH,KIT,DIN,LIV,BREAK,GAME,DLBGAR
**ALL NEW MEC**
PROJECT NUMBER: A200110817
AT THE FOLLOWING LOCATION:
LOT/BLOCK/SUBDIVISION: COURTSIDE PLACE L35
ADDRESS: 46 COURTSIDE PL
G
TO BE USED AS(OCCUPANCY): ONE- & TWO-FAMILY RESIDENTIAL
This permit is issued on the express condition that the above work shall conform in all respects to the statements certified to in
the application for such permit, and that all work shall be done in accordance with all applicable zoning, building, electrical,
plumbing and mechanical ordinances of the City of Little Rock and the State of Arkanses.
I or we further agree to abide by the applicable conditions as printed in the permit card. I or we further certify that we
have read and understand the requirements of this permit and that all statements made by us in securing this permit are true and
complete to the best of our knowledge.
Permit Fee: 235.06
DATA PROC 2.00
TOTAL: 237.06
Licensed Contr7>-*"
Owner
Issued By: STEELE FOR: CHARLES G. GIVENS
Building Official
CJTY471: LITTLE ROCK c; / �?- 5 r� `5
DEPARTMENT OF PLANNING & DEVELOPMENT
BUILDING CODES DIVISION i
723 WEST MARKHAM, 2ND FLOOR APPLICATION FOR: (HVACR)
LITTLE ROCK, AR 72201 PH: (501) 371-4826*
FAX: (501) 371-6863
aft y
PERMIT NO.
DATE ISSUED Z
INSPECTIONS
APPLICANT (Please Check'_")
Nill Call
ISSUED BY ,❑,S lab 11 Final
Rough ❑ Other
PROJECT ADDRESS:
LEGAL DESCRIPTION:LOT BLOCK SUBDIVISION
OWNERITENANT:
ADDRESS:
CONTRACTOR: C /e'ILw � hew>J
ADDRESS: IJ 7J
MECHANICAL PERMIT
INSPECTOR'S COMMENTS
PROJECT NO: mama ;5
TELEPHONE:
LICENSE NO.:
TELEPHONE: -777 -, P 5 FL l `�-/
CLASS OF WORK:/KNEW ❑ ADDITION REPL CEMENT ALTERATION. BOILER*
PROPOSED USE ( CCUPANCI): ❑ COMMERCIAL RESIDENTIAL 0 MODULAR/MOBILE HOME
SQUARE FEET: 3VALUATION: ❑ OUT OF CITY
ea ing/Air Mec anica ermf ee5:
A. New Construction
•1. One & two family DWELLING - $.07Aq.ft.
2. All other occupancies: As set forth In the cost schedules In Paragraph B. No. of
B. Replacements, repairs, alterations and additions and new COMMERCIAL
Heating, ventilating, ductwork, air conditioning, boilers•, and refrigeration systems shall be
$30.00 for the first $1.00 up to $1,000.00 or fraction thereof, of valuation of the Installation plus $500
for each additional $1,000.00 or fraction thereof. *Bol[er permits only Issued with proof of special
boiler license.
NOTE: ALL DUCTWORK REQUIRES A ROUGH INSPECTION. c�,,,,��
No. of Heating Units No. of A.ir-conditioning Untrrigger—ation
Duct work:ed..Yes ❑ No
Coriimercial'Ventilatron ystem Commercial Split System.
CHECK ONE OR MORE BELOW:
eA�Ele is Gas , ' ed �Plit System ❑Package Unit ❑ Water Source
Condenser Coil evaporative Coil ❑ Other (explain)
C. Minimum fee for any permit shall be $30.00. Additional Fee for Data Processing: $2.00 (Res.), $4.00 (Comm.).
D. Expiration of permits Is one year from date of Issuance.
E. Penalties [Working without a permit): Where work for which a permit Is required by the 1997 Arkansas
Mechanical code Is started or proceeded prior to obtaining said permit, the fee herein specified shall
be tripled; however, payment of such triple fee shall not relieve any person from fully complying with
the requirements of the 1997 Arkansas Mechanical Code in the execution of the work nor from any
penalties prescribed herein and no additional permits shall be granted until all fees have been paid.
NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND HVACR WORK.
I hereby certify that the data submitted on or with this application Is true and correct. Any deviation from
I ormation contained herein, unless approved by the Building official will render this permit: null and
S/N RSRTRN2 2 7 2 0 RIGHT-J BUILDING ANALYSIS REPORT
Zone: Entire House File name:
Job #: 46 COURTS IDE 3.5 TON RECC :
For: PAUL JONES
By: Chenal Heating & Air
13734 12th Street
Paron Ar 72212
868-8997
H E A T I N G
Component
Btuh/SgFt
Btuh
% of Btuh
Walls
4.0
7416
15.6
Windows
31.1
6912
14.5
Doors
1 29.5
619
1.3
Ceilings
1.3
2225
4.7
Floors
40.5
8493
17.8
Infilt.
64.7
15719
33.0
Ducts
6208
13.0
C O O L I N G
Component
Btuh/SgFt
Btuh
% of Btuh
Walls
2.3
4242
14.9
Windows
58.9
13082
45.9
Doors
1 16.9
354
1.2
Ceilings
1.3
2180
7.6
Floors
0.0
0
0.0
Infilt.
12.9
3144
11.0
Ducts
3720
13.0
Int.Gains
1800
6.3
Windows.
Olhei
Ceilin
Window:
BASE-S-1.RSR
Outside db
20 100
Inside db
70 75
Design TD
50 25
Daily Range
- M
Inside Humid.
- 50
Grains Water
- 46
INFILTRATION
Method
Simplified
Const. glty
Average
Fireplaces
1
Floors
Clg Tons at 8 5 % SHR - 2.9 Clg CFM/Ton = 524
Clg Tons at 7 0 % SHR = 3.6 Clg Tons at 400 CFM/Ton = 3.8
Overall U-Value = 0.128
Data entries checked.
r
Z4W�•��
f'/\), 2.(MI tQ'�
MANUAL J: 7th Ed. Right -Suite: V4.1.16
SIN
RSRTRN22720 RIGHT-J BUILDING ANALYSIS REPORT
Zone:
Entire House File name:
BASE-P-2 . RSR
Job #:
46 COURTSIDE
Outside db 20 100
For:
PAUL JONES
Inside db 70 75
Design TD 50 25
Daily Range - M
Inside Humid. - 50
By:
Chenal Heating & Air
Grains Water - 46
13734 12th Street
INFILTRATION
Paron Ar 72212
Method Simplified
868_8997
Const. glty Average
Fireplaces 1
HE A T I N G
Component
Btuh/SgFt
Btuh
% of Btuh
Walls
3.8
4443
18.5
Windows
23.8
2351
9.8
Doors
23.0
483
2.0
Ceilings
1.3
1548
6.4
Floors
1.3
1548
6.4
Infilt.
87.5
10496
43.7
Ducts
3130
13.0
C O O L I N G
Component
Btuh/SgFt
Btuh
% of Btuh
Walls
2.1
2541
20.2
Windows
44.5
4 410
35.1
Doors
13.2
276
2.2
Ceilings
1.3
1517
12.1
Floors
0.0
0
0.0
Infilt.
18.2
2187
17.4
Ducts
1640
13.0
Int.Gains
0
0.0
Windows
Doors
Ceilings
I
Walls
Window
Duds
DuCSs
Irfil"ban
__Infiltration
eflings
Doors
Clg Tons at 8 3 % SHR = 1.3 Clg CFM/Ton = 460
Clg Tons at 7 0 % SHR = 1.6 Clg Tons at 400 CFM/Ton = 1.5
Overall U-Value = 0.065
WARNING: window to floor area ratio = 8.3% - less than 10%.
MANUAL J: 7th Ed. Right -Suite: V4.1.16
I
DEC-28-01 01:02 PM JOHN W MARTIN PLUMBING 834 9988 P.04
ttp
CITY OF LITTLE ROOK APPLICATION FOR:
DEPARTMENT OF PLANNING & DEVELOPMENT PLUMBING PERMIT
723 WEST MARKHAM, 2ND FLOOR
LITTLE ROOK, AR 72201 PH: 1501) 371-4826
FAX: (501) 371-6863 W
OFFICIAL USE ONLY INSPI_CTIONS INSPECTOR'S COMMENTS OO
PERMIT NO. t 1 C)1 APPLICANT (Please Check "X") _ 35'T `tl-"
� �- A
DATE ISSUED I ? p Beady b"VI(ill Call
lab ' ❑ Final
ISSUED BY _ ❑Rough ❑Other
PROJECT ADDRESS: . \k\110_ C"� PROJECT NO.:
-
LEGAL DESCRIPTION: LOT BLOCK SUBDIVISION
OWNER/TENANT: TELEPHONE:
ADDRESS:
CONTRACTOR: I LICENSE NO.: _
ADDRESS: T- TELEPHONE: _ -
LASS OF WORK: Vr EW p ADDITION p REPAIR p ALTERATION p 2N° PLUMBER Q OUT OF CITY
PROPOSED USE (OCCUPANCY): '❑ COMMERCIAL lff�fwSIDENTIAL ❑ MODULAR/MOBILE HOME
SQUARE FEET:` VALUATION:
DESCRIPTION
QTY
UNIT
COST
DESCRIPTION
QTY
UNIT
COST
1. EACH FIXTURE
9 4,00
11. ADD. OPNGS. 0WHP OG14P
CIDWV
$3.00
2. WATER SERVICE DOMESTIC
26.00
12, FLOOR FURNACE
13.00
3. WATER HOUSEPIPING
12.00
12. UNIT HEATER
13.00
4. WATER $TANDPIPF
(requiring additional meter)
25.00
14. WALL FURNACE
13.00
5, SACKFLOW PREVENTION DEVICE
4.00
16. COMMERCIAL bRYER
13.00
B. SUMPS _
5.50
16. COMMERCIAL RANGE
13.00
7. SWIMMING POOLS 1
12,00
17. WATER HEATER
13.00
8. RENEW SOIL LINE
6.50
19. MISCELLANEOUS
15.00
9. RENEW GAS VENTS
6.50
19. INSPECTIONS (Required)
15,00
10. GAS HOUSEPIPING
15,00
20. DATA PROCESSING FEE (Required)
21. INVESTIGATIVE INSPECTION
30.00
NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING, AND HVACR WORK.
I hereby certify that the data submitted on or with this application Is true and correct. Any deviation from Information
Contained herein, unless approved by the Building Official will render this permit null and Vold.
a
a..,ana SIGNATURE OF CONTRACTOR, OWNER OR AGENT DATE
DEC-28-01 FRI 01:54 PM FROM:834 9988 TOJERMIT+-DESK PAGE 4