HomeMy WebLinkAbout200200244 MMECHANICAL PERMIT CITY OF LITTLE ROCK DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING CODES DIVISION PERMISSION IS HEREBY GIVEN TO: CONTRACTOR: CHENAL HEATING & A/C* TO PERFORM THE FOLLOWING WORK: PERMIT NUMBER:200200244 ISSUE DATE: 01/09/02 EXPIRATION DATE: 01/09/03 OWNER: NATURE OF WORK: CLASS OF WORK: NEW VALUATION: 0 SQ FT: 2,424 JOB DESCRIPTION: NEW HOUSE ,PIER, 3BR,2.5BA,GR,GR,DR,KIT, 2 STY, DBL GAR*all new mechancila** PROJECT NUMBER: A200110172 AT THE FOLLOWING LOCATION: LOT/BLOCK/SUBDIVISION: COURTSIDE PLACE L20 ADDRESS: #7 COURTSIDE PL 0 TO BE USED AS(OCCUPANCY): ONE- & TWO-FAMILY RESIDENTIAL This permit is issued on the express condition that the above work shall conform in all respects to the statements certified to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building, electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkansas. I or we further agree to abide by the applicable conditions as printed on the permit card. I or we further certify that we have read and understand the requirements of this permit and that all statements made by us in securing this permit are true and complete to the best of our knowledge. Permit Fee: 169.68 DATA PROC 2.00 TOTAL: 171.68 Issued By: BRACEY FOR: LiC"Contractoror Owner CHARLES G. GIVENS Building Official CITY OF LIThE ROCK DEPARTP,AErw OF PLANNING & DEVELOPMENT BUILDING CODES DIVISION 723 WEST MARKHAM, 2ND FLOOR I APPLICATION FOR: (HVACR) LITTLE ROCK, AR 72201 PH: (501) 371-4826- FAX: (501) 371-6863 c:;2 q OFFICIAL USE ONLY PERMIT NO.. DATE ISSUED l C D ISSUED BY MECHANICAL PERMIT ...................... .::.................................. I INSPECTIONS i INSPECTOR'S COMMENTS PROJECT ADDRESS: W7 6�U APPLICANT (Please Check'_") n Slab 0 Final, Rough 11 other LEGAL DESCRIPTION:LOT oy BLOCK 11 4 .w� �• V L T PROJECT NO.: SUBDIVISION OWNER/TENANT: 7,,5 ,w TELEPHONE: ADDRESS: CONTRACTOR: LICENSE NO.: ADDRESS: 1-3 7Jf�rLt T �t ' TELEPHONE:_ CLASS OF WORK:)KVEW 0 ADDITION 11 R PLACEMENT 11 ALTERATION BOILER* PROPOSED USE (OCCUPANCY): 11 COMMERCIAL RESIDENTIAL 11 MODULAR/MOBILE HOME SQUARE FEET: VALUATION: L ❑OUT OF CITY ea ing/Air McGTa—ir Permitees. A. New Construction •1. One & two family DWELLING - $.O Gist. - 2. All other occupancies: As ��, �' set forth In the cost schedules in Paragraph B. ',��c�-{;d�rr B. Replacements, repairs, alterations and additions and new COMMERCIAL Heating, ventilating, ductwork, air conditioning, boilers*, and refrigeration systems shall be $30.00 for the first $1.00 up to $1,000.00 or fraction thereof, of valuation of the Installation plus SS.00 for each additional $1,000.00 or fraction thereof. *Boller permits only Issued with proof of special boiler license. NOTE: ALL DUCTWORK REQUIRES A ROUGH INSPECTION. .�,,. No. of Heating Units No. of Air-conditioning Units Duct work: A x es ❑ No Commercial Ventilati-o-n-ocystem. Commercial Re rxgera- on plit System. CHECK ONE OR MORE BELOW: ❑ Eiectri as Fired ❑ Split System ❑ Package Unit ❑ Water Source ❑ Condenser Coil ❑ Evaporative Coil ❑ Other (explain) C. Minimum fee for any permit shall be $30.00. Additional Fee for Data Processing: $2.00 (Res.), $ 4.00 (Comm.). D. Expiration of permits Is one year from date of Issuance. E. Penalties (Working without a permit): Where work for which a permit is required by the 1997 Arkansas Mechanical Code Is started or proceeded prior to obtaining said permit, the fee herein specif led shall be tripled; however, payment of such triple fee shall not relieve any person from fully complying with the requirements of the 1997 Arkansas -Mechanical Code in the execution of the work nor from any penalties prescribed herein and no additional permits shall be granted until all fees have been paid. NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND HVACR WORK. I hereby certify that the data submitted on or with this application is true and correct. Any deviation from inf rmation contained herein, unless ap oved by the Building offlclal will render this permit null and S/N RS RTRN2 2 7 2 0 RIGHT-J BUILDING ANALYSIS REPORT Zone: Entire House File name: Job#: #7 COURTSIDE PLACE 1ST FLOOR 3.5TON SM For: PAUL JONES #7 COURTSIDE PLACE LITTLE ROCK AR By: Chenal Heating & Air 13734 12th Street Paron Ar 72212 868-8997 H E A T I N G Component Btuh/SgFt Btuh % of Btuh Walls 3.8 4469 10.7 Windows 30.5 7491 18.0 Doors 23.5 987 2.4 Ceilings 1.3 2262 5.4 Floors 40.5 6658 16.0 Infilt. 49.9 14384 34.5 Ducts 5437 13.0 COOT. I NG Component Btuh/SgFt Btuh % of Btuh Walls 2.1 2556 10.6 Windows 44.8 11016 45.5 Doors 13.4 565 2.3 Ceilings 1.3 2 217 9.2 Floors 0.0 0 0.0 Infilt. 10.0 2877 11.9 Ducts 3154 13.0 Int.Gains 1800 7.4 Clg Tons at 8 4 % SHR = 2.5 Clg Tons at 70 % SHR = 3.0 Overall U-Value = Data entries checked. Pam- 2-00% lot ri �� Gou►r�i+� Windows Doors Ceflin Windows BASE-S-1.RSR Outside db 20 100 Inside db 70 75 Design TD 50 25 Daily Range - M Inside Humid. - 50 Grains Water - 46 INFILTRATION Method Simplified Const. glty Average Fireplaces 1 Floors Clg CFM/Ton = Clg Tons at 400 CFM/Ton = 0.129 MANUAL J: 7th Ed. Right -Suite: V4.1.16 462 2.9 S/N Zone: Job #: For: By: RSRTRN22720 RIGHT-J BUILDING ANALYSIS REPORT Entire House File name: PAUL JONES 7 COURTSIDE LITTLE ROCK 952-1000 Chenal Heating & Air 13734 12th Street Paron 868-8997 Ar 72212 H E A T I N G Component Btuh/SgFt Btuh % of Btuh Walls 3.8 5006 14.5 Windows 30.5 2741 7.9 Doors 0.0 0 0.0 Ceilings 1.7 2376 6.9 Floors 40.5 7 213 20.9 Infilt. 141 12697 36.8 Ducts 4505 13.0 C O O L I N G Component Btuh/SgFt Btuh % of Btuh Walls 2.1 2863 19.4 Windows 35,6 3204 21.7 Doors 0.0 0 0.0 Ceilings 1.6 2328 15.8 Floors 0.0 0 0.0 Infilt. 29.4 2645 17.9 Ducts 1926 13.0 Int.Gains 1800 12.2 Windows BASE—S-1.RSR Outside db 20 100 Inside db 70 75 Design TD 50 25 Daily Range - M Inside Humid. - 50 Grains Water - 46 INFILTRATION Method Simplified Const. glty Average Fireplaces 1 Ceilings Clg Tons at 7 7 % SHR = 1.7 Clg CFM/Ton = Clg Tons at 7 0 % SHR = 1.8 Clg Tons at 400 CFM/Ton = Overall U-Value = 0.114 WARNING: window to floor area ratio = 6.3% - less than 10%. MANUAL J: 7th Ed. Right -Suite: V4.1.16 I me;nal Ga•.ns m 386 1.6