Loading...
HomeMy WebLinkAbout200201928 MMECHANICAL PERMIT CITY OF LITTLE ROCK DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING CODES DIVISION PERMIT NUMBER:200201928 ISSUE DATE: 03/06/02 EXPIRATION DATE: 03/06/03 PERMISSION IS HEREBY GIVEN TO: CONTRACTOR: RECTOR PHILLIPS MORSE* OWNER: Beal, Robert TO PERFORM THE FOLLOWING WORK: NATURE OF WORK: CLASS OF WORK: ADD VALUATION: 2,500 SQ FT: JOB DESCRIPTION: ADD TO MASTER BDRM 20X30**HT,A/C,DW,2INSP** PROJECT NUMBER: A200111110 AT THE FOLLOWING LOCATION: LOT/BLOCK/SUBDIVISION: ADDRESS: 5309 COUNTRY CLUB 1i TO BE USED AS(OCCUPANCY): ONE- & TWO-FAMILY RESIDENTIAL He This permit is issued on the express condition that the above work shall conform in all respects to the statements certified to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building, electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkansas. I or we further agree to abide by the applicable conditions as printed on the permit card. I or we further certify that we have read and understand the requirements of this permit and that all statements made by us in securing this permit are true and complete to the best of our knowledge. Permit Fee: 55.00 DATA PROC 2.00 TOTAL: 57.00 Licensed Contractor or Owner Issued By: ONEAL FOR: CHARLES G. GIVENS Building Official 11 A Vs- 2.I1 ■ EPARTMENT OF PLANNING & DEVELOPMENT ' UILDING CODES DIVISION 23 WEST fItTARKHAM, 2ND FLOOR APPLICATION FOR: (HVACR) ITTLE ROCK, AR 72201 PH: (501) 371-4826' Ax: (501) 371-6863 : MECHANICAL PERMIT OFFICIAL USE ONLY PERMIT NO.Z2 DATE ISSUED Le ISSUED BY r INSPECTIONS APPLICANT (Please check"') ❑ Will Call El Slab i Final Rough ❑ Other oazz=e4orrR�'S COMME�11T5 ROJECT ADDRESS: " �` %� ,. � PROJECT NO.:. � & .- -::GAL DESCRIPTION:LOT BLOCK SUBDIVISION WNER/TENANT: Y� TELEPHONE: r Q / 6- DDRESS: )NTRACTOR: '�-'- �/ LICENSE NO.: DRESS: ��� / � , �� , 5,c- C� ^, TELEPHONE: �/ - �/ c) _ASS OF WORK: 11 NEW ADDITION lli4POCEMENT 0 ALTERATION ❑ BOILER* IMPOSED USE (OCCUPANCY): O COMMERCIAL )4 RESIDENTIAL 13 MODULAR/MOBILE HOME SQUARE FEET- VALUATION: ` � ' _ ❑ OUT CF t:ITY — Heating/Air Mecl an icaTPermit Fees: A. New Construction -1. One & two family DWELLING - $.05/sq.ft. 2. All other occupancies: As set forth in the cost schedules In Paragraph B. Ar B. Replacements, repairs, alterations and additions and new COMMERCIAL NO. Heating, ventilating, ductwork, air conditioning, boilers*, and refrigeration systems shall be $30.00 for the first $1.00 up to $1,000.00 or fraction thereof, of valuation of the installation plus $3.00 for each additional $1,000.00 or fraction thereof. *Boiler permits only issued with proof of special boiler license. NOTE: ALL DUCTWORK REQUIRES A ROUGH INSPECTION. No. of Heating Units No. of Air-conditioning Units �' Duct work: 0 Yes ❑ No Commercial Ventilaho' n-System Commercial Re ngeration SpUt System CHECK ONE OR MORE BELOW: ❑ Electric MOas Fired ❑ Split System ©'Package Unit ❑ Water Source El Condenser Coil ❑ Evaporative Coil ❑ Other (explain) C. Minimum fee for any permit shall be $30.00. Additional Fee for Data Processing: $2.00 (Res.), $4.00 (Comm.). D. Expiratlon of permits is one year from date of Issuance. E. Penal tieS (Working without a permit): Where work for which a permit is required by the 1997 Arkansas Mechanical Code is started or proceeded prior to obtaining said permit, the fee herein specif led shall be tripled, however, payment of such triple fee shall not relieve any person from fully complying with the requirements of the 1997 Arkansas Mechanical Code in the execution of the work nor from any Penalties prescribed herein and no additional permits shall be granted until all fees have been paid. NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND HVACR WORK. I hereby certify that the data submitted on or with this application Is true and correct. Any deviation from Information contained herein, unless approved by the Building Official will render this permit null and Vold. ' � vl;� ED'S SUPPLY Heat Load Detail Report for RPM Room 1 of 3 Room Specifications: BEDROOM Room Length (Ft.) : 18A Sq. Ft windows facing NE & NW: - Watts Incandescent Light: 240 Room Width (Ft.) : 22 Sq. Ft windows facing South: - Watts Flourescent Light: -- Room Height (Ft.) : 9 Sq. Ft windows facing SE & SW: - Duct Length from A/H to room: — Exposed Wall Length (Ft.) : 62.4 Number of Exterior Doors: -- Number of Large Electric Motors: — Wall against unconditioned room (Ft.) :45 Sq. Ft. Exterior Doors: -- Average Electric Motor Horsepower: — Sq. Ft windows facing North: 12.6 Number of People in Room: 2 BTUH Appliance Sensible Heat: — Sq. Ft windows facing E & W: 11.5 BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures (degrees Farenheit) Summer: Winter: Inside (Thermostat setting) 74 Inside (Thermostat setting) : 72 Outside (Above ground): 96 Outside (Above ground: 20 Outside (Below ground): 65 Outside (Below ground) : 60 Unconditioned Space: 97 Unconditioned Space: 65 Above Ceiling (Attic/Crawl Space) : 130 Above Ceiling (Attic/Crawl Space) : 45 Concrete Slab (Ground temperature) 80 Concrete Slab (Ground temperature) : 55 Unconditioned Basement: 60 Unconditioned Basement: 55 Below Floor Crawl Space: 85 Below Floor Crawl Space: 50 Applicable Temperatures: Above Ceiling: Attic or Crawl Space Below Floor: Crawl Space Exposed Walls: Above Ground Design Conditions Insulation Values (U-Factors) Occupant Sensible Load (BTUH per person) : 250 Exposed Walls (Above Ground) : .080 Occupant Latent Load (BTUH per person) : 200 Exposed Walls (Below Ground) : .5 Duct Insulation Factor: 1 Partitions : .075 Duct Temperature Difference (Summer) : 20 Roof/Ceiling : .055 Duct Temperature Difference (Winter) : 45 Floor (Above basement) : .083 Humidity Difference Inside/Outside % (Summer) 20 Floor (Concrete slab) : .001 Humidity Difference Inside/Outside %(Winter) : 15 Floor (Between conditioned spaces) : .287 Fresh Air Per Person (CFM) : 2 Doors : .500 Air Change Factor (Air change per hour) : .5 Windows: .900 Space Shading Factor: .4 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 600 Calculated Room Results - Summer Heat Gains Wall Heat Gain (BTUH) : 1687 Appliance/Elec Motor Latent Heat Gain (BTUH) : 400 Ceiling or Roof Heat Gain (BTUH) : 1247 Appliance/Elec Motor Sensible Heat Gain (BTUH) :1318 Floor Heat Gain (BTUH) : 370 Ventilation Latent Heat Gain (BTUH) : 408 Glass Heat Gain (BTUH) : 207 Ventilation Sensible Gain (BTUH) : 723 Exterior Door & North Window Heat Gain (BTUH) : 116 Summer Total Latent Heat Gain: 808 Solar Heat Gain (BTUH) : 989 Summer Total Sensible Heat Gain (BTUH) : 6657 Total Transmission Heat Gain (BTUH) : 4616 TOTAL SUMMER COOLING LOAD (BTUH) : 7465 Calculated Room Results - Winter Heat Losses Transmission Heat Losses (BTUH) : 4655 Latent Ventilation Heat Losses (BTUH) : 306 Sensible Ventilation Heat Losses (BTUH) : 1708 Hydronic Heat(Linear Ft.) : 11 TOTAL WINTER HEATING LOAD (BTUH). 6669 Calculated Totals for Entire Structure Size of Structure (Sq. Ft.): 667 Total Sensible Heat Gain (BTUH): 13779 Total Heat Loss (BTUH): 14889 Total Cooling Gain (BTUH): 16320 Total Hydronic Heat (Linear Ft.): 24.82 Total Cooling Requirement (Tons): 1.36 Total Latent Heat Gain (BTUH): 2541 Total Cooling CFM: 544 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account. Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. Prepared 2/22/02 using O'Brien Quick Loads Pro - Version 1.01 - SN: QP-070101-40304 ED'S SUPPLY Heat Load Detail Report for RPM Room 2 of 3 Room Specifications: CLOSET Room Length (Ft.) : 11.8 Sq. Ft windows facing NE & NW: — Watts Incandescent Light: 150 Room Width (Ft.) : 11.4 Sq. Ft windows facing South: — Watts Flourescent Light: — Room Height (Ft.) : 9 Sq. Ft windows facing SE & SW: — Duct Length from A/H to room: — Exposed Wall Length (Ft.) : 24 Number of Exterior Doors: 1 Number of Large Electric Motors: -- Wall against unconditioned room (Ft.) :24 Sq. Ft. Exterior Doors: 21 Average Electric Motor Horsepower: — Sq. Ft windows facing North: — Number of People in Room: 2 BTUH Appliance Sensible Heat: — Sq. Ft windows facing E & W: — BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures (degrees Farenheit) Summer: Winter: Inside (Thermostat setting) : 74 Inside (Thermostat setting) : 72 Outside (Above ground): 96 Outside (Above ground : 20 Outside (Below ground): 65 Outside (Below ground) : 60 Unconditioned Space: 97 Unconditioned Space: 65 Above Ceiling (AtticfCrawl Space) : 130 Above Ceiling (Attic/Crawl Space) : 45 Concrete Slab (Ground temperature) 80 Concrete Slab (Ground temperature) : 55 Unconditioned Basement - 60 Unconditioned Basement: 55 Below Floor Crawl Space: 85 Below Floor Crawl Space: 50 Applicable Temperatures: Above Ceiling: Attic or Crawl Space Below Floor: Crawl Space Exposed Walls: Above Ground Design Conditions Insulation Values (U-Factors) Occupant Sensible Load (BTUH per person) : 250 Exposed Walls (Above Ground) : .080 Occupant Latent Load (BTUH per person) : 200 Exposed Walls (Below Ground) : .5 Duct Insulation Factor: 1 Partitions: .075 Duct Temperature Difference (Summer) : 20 Roof/Ceiling : .055 Duct Temperature Difference (Winter) : 45 Floor (Above basement) : .083 Humidity Difference Inside/Outside % (Summer) : 20 Floor (Concrete slab) : .001 Humidity Difference Inside/Outside %(Winter) : 15 Floor (Between conditioned spaces) : .287 Fresh Air Per Person (CFM) : 2 Doors : .500 Air Change Factor (Air change per hour) : .5 Windows: .900 Space Shading Factor: .4 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 600 Calculated Room Results - Summer Heat Gains Wall Heat Gain (BTUH) : 753 Appliance/Elec Motor Latent Heat Gain (BTUH) : 400 Ceiling or Roof Heat Gain (BTUH) : 414 Appliance/Elec Motor Sensible Heat Gain (BTUH). 1012 Floor Heat Gain (BTUH) : 123 Ventilation Latent Heat Gain (BTUH) : 805 Glass Heat Gain (BTUH) : 0 Ventilation Sensible Gain (BTUH) : 1428 Exterior Door & North Window Heat Gain (BTUH) : 194 Summer Total Latent Heat Gain: 1205 Solar Heat Gain (BTUH) : 0 Summer Total Sensible Heat Gain (BTUH) : 3924 Total Transmission Heat Gain (BTUH) : 1484 TOTAL SUMMER COOLING LOAD (BTUH) : 5129 Calculated Room Results - Winter Heat Losses Transmission Heat Losses (BTUH) : 1916 Latent Ventilation Heat Losses (BTUH) : 604 Sensible Ventilation Heat Losses (BTUH) : 3376 Hydronic Heat(Linear Ft.) : 10 TOTAL WINTER HEATING LOAD (BTUH) : 5896 Calculated Totals for Entire Structure Size of Structure (Sq. FQ: 667 Total Sensible Heat Gain (BTUH): 13779 Total Heat Loss (BTUH): 14889 Total Cooling Gain (BTUH): 16320 Total Hydronic Heat (Linear Ft.): 24.82 Total Cooling Requirement (Tons): 1.36 Total Latent Heat Gain (BTUH): 2541 Total Cooling CFM: 544 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account. Correct system sizing: is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. Prepared 2/22/02 using O'Brien Quick Loads Pro - Version 1.01 - SN: QP-070101-40304 ED'S SUPPLY Heat Load Detail Report for RPM Room 3 of 3 Room Specifications: BATH Room Length (Ft.) : 10.8 Sq. Ft windows facing NE & NW: — Watts Incandescent Light: 150 Room Width (Ft.) : 11.8 Sq. Ft windows facing South: — Watts Flourescent Light: — Room Height (Ft.) : 9 Sq. Ft windows facing SE & SW: — Duct Length from A/H to room: — Exposed Wall Length (Ft.) : 23 Number of Exterior Doors: — Number of Large Electric Motors: — Wall against unconditioned room (Ft.) :23 Sq. Ft. Exterior Doors: — Average Electric Motor Horsepower: — Sq. Ft windows facing North: — Number of People in Room: 2 BTUH Appliance Sensible Heat: — Sq. Ft windows facing E & W: 7 BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures (degrees Farenheit) Summer: Inside (Thermostat setting) : 74 Winter: Inside (Thermostat setting) : 72 Outside (Above ground): 96 Outside (Above ground : 20 Outside (Below ground): 65 Outside (Below ground) : 60 Unconditioned Space: 97 Unconditioned Space: 65 Above Ceiling (Attic/Crawl Space) : 130 Above Ceiling (Attic/Crawl Space) : 45 Concrete Slab (Ground temperature) . 80 Concrete Slab (Ground temperature) : 55 Unconditioned Basement: 60 Unconditioned Basement: 55 Below Floor Crawl Space: 85 Below Floor Crawl Space: 50 Applicable Temperatures: Above Ceiling: Attic or Crawl Space Below Floor: Crawl Space Exposed Walls: Above Ground Design Conditions Insulation Values (U-Factors) Occupant Sensible Load (BTUH per person) : 250 Exposed Walls (Above Ground) : .080 Occupant Latent Load (BTUH per person) : 200 Exposed Walls (Below Ground) : .5 Duct Insulation Factor: 1 Partitions : .075 Duct Temperature Difference (Summer) : 20 Roof/Ceiling : .055 Duct Temperature Difference (Winter) : 45 Floor (Above basement) : .083 Humidity Difference Inside/Outside % (Summer) : 20 Floor (Concrete slab) : .001 Humidity Difference Inside/Outside %(Winter) : 15 Floor (Between conditioned spaces) : .287 Fresh Air Per Person (CFM) : 2 Doors : .500 Air Change Factor (Air change per hour) : .5 Windows: .900 Space Shading factor: .4 Air Handier Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 600 Calculated Room Results - Summer Heat Gains Wall -Heat Gain (BTUH) : 721 Appliance/Elec Motor Latent Heat Gain (BTUH) : 400 Ceiling or Roof Heat Gain (BTUH) : 393 Appliance/Elec Motor Sensible Heat Gain (BTUH) :1012 Floor Heat Gain (BTUH) : 116 Ventilation Latent Heat Gain (BTUH) : 128 Glass Heat Gain (BTUH) : 126 Ventilation Sensible Gain (BTUH) : 228 Exterior Door & North Window Heat Gain (BTUH) : 0 Summer Total Latent Heat Gain: 528 Solar Heat Gain (BTUH) : 602 Summer Total Sensible Heat Gain (BTUH) : 3198 Total Transmission Heat Gain (BTUH) : 1959 TOTAL SUMMER COOLING LOAD (BTUH) : 3726 Calculated Room Results - Winter Heat Losses Transmission Heat Losses (BTUH) : 1690 Latent Ventilation Heat Losses (BTUH) : 96 Sensible Ventilation Heat Losses (BTUH) : 538 Hydronic Heat(Linear Ft.) : 4 TOTAL WINTER HEATING LOAD (BTUH) : 2324 Calculated Totals for Entire Structure Size of Structure (Sq. Ft.): 667 Total Sensible Heat Gain (BTUH): 13779 Total Heat Loss (BTUH): 14889 Total Cooling Gain (BTUH): 16320 Total Hydronic Heat (Linear Ft.): 24.82 Total Cooling Requirement (Tons): 1.36 Total Latent Heat Gain (BTUH): 2541 Total Cooling CFM: 544 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account. Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. Prepared 2122/02 using O'Brien Quick Loads Pro - Version 1.01 - SN: QP-070101-40304