Loading...
HomeMy WebLinkAbout200110929 BBUILDING PERMIT CITY OF LITTLE ROCK DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING CODES DIVISION PERMIT NUMBER:200110929 ISSUE DATE: 12/13/01 EXPIRATION DATE: 12/13/02 PERMISSION IS HEREBY GIVEN TO: CONTRACTOR: EAST HARDING INC* OWNER: TO PERFORM THE FOLLOWING WORK: NATURE OF WORK: CLASS OF WORK: ALT VALUATION: 200,000 -SQ FT: JOB DESCRIPTION: TENANT FINISH ON THIRD SPACE PROJECT NUMBER: A200110929 AT THE FOLLOWING LOCATION: LOT/BLOCK/SUBDIVISION: ADDRESS: 2300 COTTONDALE LN MANGAN, HOLCOMB, RAINWA 0 TO BE USED AS(OCCUPANCY): **COMMERCIAL This permit is issued on the express condition that the above work shall conform in all respects to the statements certified to in the application for such permit, and that all work shall be done in accord;tice with all applicable zoning, building, electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkanses. I or we further agree to abide by the applicable conditions as printed in the permit card. I or we further certify that we have read and understand the requirements of this permit and that all statements made by us in securing this permit are true and complete to the best of our knowledge. Permit Fee: 449.50 PLAN REVIEW 112.38 DATA PROC 4.00 EDUCATION TAX 100.00 TOTAL: 665.88 sed C❑ Issued By: ONEAL FOR: CHARLES G. GIVENS or or Owner Building Official CITY OF LITTLE ROCK PLAN NO. DEPARTMENT OF NEIGHBORHOODS & PLANNING BUILDING CODES DIVISION APPLICATION FOR: 17.jk 723 WEST MARKHAM. 2ND FLOOR LITTLE ROCK, AR 72201 BUILDING PERMIT ..................................................................... OFFICIAL USE ONLY *#SUBDIVISION COVENANTS AND RESTRICTIONS NOTICE" PERMIT NO.: DATE ISSUED: ISSUED BY: PROJECT ADDRESS: The City gives permission for this project in accordance with local ordinances. However, there may be subdivision covenants and restrictions that apply; and this permit does not void, or override those covenant's and restrictions. LEGAL DESCRIPTION: LOT_ BLOCK SUBDIVISION: OWNER/TENANT: TELEPHONE:lvl ADDRESS: CONTRACTOR: S vV LICENSE NO.: ADDRESS: �� TELEPHONE: ARCHITECT: �L'l LICENSE NO.: .SS: CJd Sf h�G TELEPHONE: n r7 ENGINEER: �IG4 *LICENSE NO.: 17 ��� ADDRESS: ��� TELEPHONE: CLASS OF WORK: ❑ NEW ❑ MOVE ❑ ADDITION ❑ DEMOLISH ❑ REPAIR ❑ ALTERATION ❑ ACCESSORY ❑ TEMPORARY i PROPOSED USE (OCCUPANCY):, SQUARE FEET: VALUATION: J N0. OF BUILDINGS: -- NO. OF UNITS: NO. OF FLOORS: DESCRIPTION OF WORK: h AT . y NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND AIR COND1710NING WORK. 1 r certify that the data submitted on or with this application is true and c act. Also, 1 have read and understand the „abdivision Covenants and Restrictions Notice as stated above. ny d ration from information contained hereon unless approved by the ilding Offic/wilender this permit null a 12 Sig re of Contractor, Ow er or AgeDate Agent �� City of Little Rock Department of Planning and Development Building Codes 723 West Markham Street Little Rock, Arkansas 72201-1334 Phone: (501) 371-4826 Fax: (501) 371-6863 1 detc! ire. th,-at I did or will execute -, ',q irensL's ; i'ated in this letter. D 3 �b) Signed _ f December 13, 2001 East Harding 2230 Cottondale Lane, Suite 3 Little Rock, Ark RE: 2300 Cottondale Lane Third Floor (M.H.R.C.) Dear Sir: -This project was reviewed as Business Occupancy type V unprotected not sprinkled. The following items need to be addressed before a permit is issued for this project. 1. Individual glass panels within an ingress/egress door or within 24 inches of door openings shall be safety glazed in accordance with Section 2405.2.1 (3). &j,.0 2. Stair enclosure doors are required to be one hour labeled with the temperature rise requirement. ejo C. 3. All materials used in the ceiling return air plenum are required to be constructed entirely of noncombustible materials as per Section 609.1.7 of the 1997 Standard Mechanical Code. All wires, cables, phone lines, computer lines, etc, are required to be plenum approved. PVC and ABS piping is not allowed in a return air plenum. W G 4. Exit lights are required as per Section 1016.3 SBCCI 1997. Be mindful that there are situations where exit signs in normally acceptable locations have been obscured by ducts, equipment installations, store fixtures, and office furniture. Additional signs may be required to provide safe exiting. Ok 5. The Plumbing Department has accepted the plans subject to compliance with city ordinances. Contact Ronnie Campbell with any questions at 501-371-4840. APPLICATION FOR PERMIT AT 2300 COTTOMDALE LN. PAGE # 2 G �K 6. The Electrical Department has approved the plans with the following conditions. Contact Jerry Spence with any questions at 501-371-4836. a. A convenience GFCI protected electrical receptacle is required for the mechanical units as per the NEC Section 210-63. The permit fee is $449.50, the review fee is $112.38, and the data fee is $4.00, for a total of $565.88. Plus $100.00 for Act 474. If we can be of any assistance or you have any questions please call Rex Lyons at 501-371- 4724, David McClymont at 501-371-4875 or Mark Whitaker at 501-371-4839. The fax number is 501-371-6963. erely, j1 Rex Lyons Plans Examiner r C w u 0 as A o F' O z A A A 0 z O W z � A � � z � a a a CITY OF LITTLE ROCK DEPARTMENT OF PLANNING AND DEVELOPMENT CERTIFICATE OF OCCUPANCY Address r SL)D Q6` �cr,3�- Permi` Issue Date oa l J Zoning -ca 0 _ _ Block No. Fire Zone Lot No. Occupancy _ S Addition Type Construction :17�" Building Permit No. ;),W i 10CV-3L Building Height (Stories) Maximum allowable floor load per sq.ft. Use ► Basement Owner of Land 1ti o . yt . y" Address Owner of Improvements Address Tenant M Remarks r ' . (" BLDG INSPECTOR: � �`� Date ? �tf 7 o� L 1 T T1k City of Little Rock �° REMODELING 714 PERMIT �bING �� Permit No. 2.9- U- -r P OWNER CONTRA LOT: ADDRESS: BLOCK ,aL ADITION: J. ,r.- jzx Pe mit NO Valid gales Stamped °paid"� By C+ - ashier . City of Little Rai Phmnmg k Dadopmmt MUM Codes Dmoon 723 Wert Mukham street Little Rock, Mamas 72201-1334 Phoac:(501) 3714826 Fax(501) 371-863 PERMIT CONDITIONS 1. SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, GAS, ELECTRICAL, HVACR !-amqfal) INSTALIATIONS 2. This permit conveys no right to occupy any street alley or sidewalk or any part thereof, either temporary or permanently except that specifically provided for in the Building Code. The issuance of this permit does not release the applicant from the conditions of any applicable subdivision restrictions. Adequate house numbers must be posted at the beginning of construction. 3. THIS CARD SHOULD BE PROTECTED FROM THE ELEMENTS AT ALL TIMES! - INSPECTION REQUESTS RECIEVED BY 9:00 A.M. - MADE SAME DAY BUILDING HVACR (Mechanical) PLUMBING GAS Residential: 371- 4833/34 Commercial: 371-4827 1. Footing 8t Foundation Date By Date-6219-Rv 3.0ccupancyInspection Date By Residential / Commercial All Call: 918-5282 1. Slab Date By 2. Rough cZeW;;;� Date By7-- 3. Final Date l`0 )` By� REMARKS Residential / Commercial All Call: 371-4841/42 or 371-4826 1. Slab 1. Rough Date By Date By 2. Rough 6�-- 2. Final Date r's-- a ;z By -Pc 3. Final Date --27 - o,-'— By Date By ELECTRICAL Residential / Commercial Call: 371-4837/38 �!412'.[�1V 1. Rough _ - Date ',! —?`9By j 2. Final Da4' REQUIRED INSPECTIONS KEEP THIS CARD POSTED until final 1. Framing - Prior to covering structural inspection has been made. Such building members. SHALL NOT BE OCCUPIED until 2. Final inspection for compliance prior FINAL INSPECTION has been made to occupancy. and approved. UNLAWFUL TO REMOVE OR DEFACE THIS CARD THIS CARD WILL BE PICKED UP BY THE BUILDING INSPECTOR AT FINAL INSPECTION f ^� Date: 12/4/01 Voegele Mechanical P. O. Box 15485 Little Rock, AR 72231 Ph. # (501) 945-6951 Arkansas Department of Health 4815 West Markham Street o Liulc Rock, Arkansas 72205- 867 • Telephtnre. 1.501 i 661-2000 Fay W Boozman, M.D. Director Mike Huckabee, Governor Proj # 36981 PD # 01-1802 Mangan Holcomb -Rainwater Culpepper Off. 2300 Cottondaie Lane-3rd Floor Little Rock, AR The plans and specifications for the above referenced project have been reviewed and approved by the Plumbing and Natural Gas Section of the Division of Protective Health Codes. No deviations from the accepted plans, specifications, and/or addenda will be permitted during construction except by prior written acceptance. This approval is valid for one (1) year from the date on this letter or this acceptance must be re- validated by contacting this office referring to the above referenced file numbers. All plumbing and gas work shall meet minimum state standards and be performed by a duly licensed master plumber. Please refer to any footnotes at the bottom of this letter regarding required changes or the need for additional plumbing. This approval is for the plumbing portion of this project only. Swimming pools, public water/sewer extensions, food service, fire protection systems, septic systems, and water wells are regulated by other agencies of the Arkansas Department of Health and are subject to plan review approval before construction and the inspection of systems after construction. The following people shall be contacted at least twenty-four (24) hours before construction. Inspection fees and municipal permits may be required. For more information regarding this approval, please contact us at (501) 661-2642. (NOTE): Floor drains shall not be installed in return air. (NOTE): Ark State Plbg. Code Sec: 14.3.4. The Architect, Engineer, designer or agent of the owner shall provide all contractors a copy of the acceptance approval letter. Chief City Plumbing Inspector City of Little Rock 723 W. Markham Street Little Rock, AR 72201 Resp tfully, �,. Dewey Broadway, Plans Reviewer Plan Review Sec66n Plumbing and Natural Gas Section DB/jb CC: Sanitarian City Plumbing Inspector: District Inspector: Wayne Cotton --Ph# (501) 280-3378 Keeping Your Hometown He+afthy "Art Equal opponunry Driployer" ZO-d VEO:60 ZO—Z1—Z)a0 PD # 01-1802 This Project # M81 HAS BEEN APPROVED with these additional (checked) notes. Fil 1-1 The installation of Water Heaters shall comply with the State Plumbing & Gas Code. Section: Chapter 10 water heater details are required. The Water Distribution System shall be installed in accordance with the Arkansas State Plumbing Code. Section: The Combination Waste and Vent Systems shall be installed in accordance with the Arkansas State Plumbing Code. Section 12.18. Fixtures, down stream from water closets shall be individually vented with exception of another water closed. Section 12.12.2. Arkansas State Plumbing Code. The Sanitary Venting System shall be installed in accordance with the Arkansas I___J State Plumbing Code. Section: The Sanitary Drainage System shall be installed in accordance with the Arkansas X Plumbing Code. Section: Traps are required for the ice machine and receptor for the water heater. (P rincipie #10) 5.1.3. Trap primer is required for the drain that serves as the T&P rece or. QThe Grease Interceptor shall be installed in accordance with the Arkansas State Plumbing Code. Section: 6.2.1.-6.2.2.-6.2.3. Fol The Commercial Food Grinder shall be installed in accordance with the Arkansas State Plumbing Code. Section: 6.11.1. The Minimum Facilities shall be installed in accordance with the Arkansas State Plumbing Code. Section: 7.21.1 11 The Natural Gas System shall comply to Section: X Riser diagrams are needed for the plans. Water F1Approved Sewage Disposal and Water Source Additional Notes: Please refer to these guidelines for submitting future projects. Projects X submitted for review shall be in strict compliance with these guidelines and the Ark State Plb . Code.... 10'd VS0=60 ZO-ZZ-:D0 Permit Fee Calculations from $100,001.00 to $300,000.00 Valuations Project Valuation Permit Fee $ 200.000.00 $ 449.50 $ Review Fee Data Fee 112.38 $ 4.00 $ Education Tax $ Total Fee $ Total Fee 565.88 100.00 665.88