HomeMy WebLinkAboutHDC1998-028 Inspection And Evaluation Of Structure 05/30/1998Dennis Yarbro, P.E. 10629 Hwy 300 C>/1 Roland, AR 72135 Registration #7993 June 19, 1998 Inspection and Evaluation of Structure 1006 Rock Street, Little Rock, AR Conducted May 30,1998 An inspection of the structure at 1006 Rock was conducted in the presence of the owners. After an initial viewing of the subject structure from the house on the south side, I performed an evaluation from the inside and outside of the subject structure. While a lot of the superficial material is still mostly intact, a substantial portion of the structural support of the building is in very bad condition. Due to the very deteriorated nature of the building, a more detailed investigation of the rafters, support walls and floor support was not made for safety considerations. The roof needs to be replaced. Approximately 50% of the roof would need to be torn off, structure and all and replaced. This is time consuming and dangerous work, since a lot of the underlying support, completely down to the house sills, floor joists, ceiling joists and rafters would have to come out and be replaced. During this major construction phase, the rest of the house would need to be braced to prevent sagging and movement of the structural members that would not be replaced during the work. This will add substantially to the cost. Once the building is repaired, then a new roof would need to be put on. Much of the floor is badly deteriorated, mainly due to the roof having leaked through, deteriorating the rafters, ceiling joists, ceiling and flooring. At least two rooms need to be completely replaced, from the sills, floor joists, some of the studs in load bearing walls as well as the ceiling joists and rafters. To do this piecemeal would be hazardous, time consuming and expensive. Besides the accumulation of debris throughout the house, there is a lot of animal waste, dust and unknown material throughout the house. Some analysis might need to be preformed to determine the exact nature of the material used in construction or stored there. All the electrical and plumbing would need to be torn out and replaced with compliant materials and workmanship. This includes all interior lighting fixtures, wiring, boxes, sinks, tubs, bathroom fixtures and materials. New hot water heater(s) would also be required. The exterior is in poor to good condition. Most of the exterior siding might be salvaged, albeit at a high cost, or new siding installed. Most of the windows and doors would need to be replaced with well -made casings, glass, hardware and screens where needed. Some resizing of the window openings probably would be needed due to the older size and style of the existing windows (or custom windows purchased). Attached is an estimate for rehabilitation of the structure, bringing it to electrical, plumbing codes and removal of debris. This estimate is not detailed, since the inspection performed by the Little Rock Codes Enforcement detailed that which is required to bring the building up to code. 1006 Rock Street Description of Work Roof: Remove Old Roof Replace Required Structure Re -roof House Ceilings: Remove deteriorated structure Replace Required Structure Finish ceilings Floors and Floor Joists: Remove deteriorated Floors Replace Flooring Exterior Walls: Remove Deteriorated Structure Replace Deteriorated Structure Refinish exterior walls Interior walls: Remove required material Replace wall material Finish walls :Plumbing: Bring Plumbing to code Area Estimate Cost (per Estimated Cost Ft) 1400; 9. $ 12,600 600, 13 $ 7,800 _............. 1400 4 $ 5,600 400 9 $ 3,600 400; 9 $ 3,600 1200 5 $ 6,000 500 10 $ 5,000 800 6 ` $ 4,800 500 800 800 2200 Two baths, kitchen !� 1 Electrical: Bring Electrical to Code .Remove debris Tota I 12 $ 6,000 12.= $ 6,000 $ 10,000 5i $ 4,000 4 $ 3,200 3 $ 6,600 $ 23,000 $ 12,000 $ 6,000 $ 125,800