Loading...
HomeMy WebLinkAboutHDC2025-006 Staff Report FullApril 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 NAME: Welch-Cherry House - Certificate of Appropriateness LOCATION: 700 S. Rock Street, Little Rock, AR 72201 OWNER/AUTHORIZED AGENT: First Lutheran Church Edward R. Sergeant, 314 E 8th Street Sergeant Architecture PLLC Little Rock, AR, 72202 1858 S Arch Street Little Rock, AR, 72206 Figure 1. Welch-Cherry House, 700 S. Rock Street. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 2 AREA: 0.36 acres NUMBER OF LOTS: 1 WARD: 1 HISTORIC DISTRICT: MacArthur Park Historic District HISTORIC STATUS: Contributing CURRENT ZONING: R4A – Low Density Residential CONSERVATION EASMENT: 2016, Arkansas Historic Preservation Program A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT: The application requests for the alteration of the rear (west) two-story enclosed porch, the removal and replacement of the existing ADA ramp, the installation of new porch handrails on the south side porch and east front porch, the enclosure of the south porch pier foundation. B. BACKGROUND Location The subject property is located at 700 S. Rock Street. The property’s legal description is "W40’ of Lot 10 and All of Lots 11 and 12, Block 42, City of Little Rock, Pulaski County, Arkansas.” Context The subject property sits at the southwest corner of E 7th Street and S Rock Street and is the site of the Welch-Cherry House, a two-story brick masonry structure built as a residence in 1881 in the Italianate style. The structure is Contributing to the MacArthur Park Historic District and the most recent Arkansas Architectural Resource Form (PU2830, 2007) is provided as Attachment C. Figure 2. Welch-Cherry House, 700 S Rock Street, located in MacArthur Park Historic District. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 3 Development History The Welch-Cherry House displays a compound front-facing T plan with an asymmetrical front gable and cross-gable roof. The home displays subdued Italianate details, such as tall and narrow two-over-two wood windows with hooded, segmental arches, and simple eaves with built-in gutters. Frame partial porches, single-story and two-story, sit against each elevation with collective square porch supports with beveled (chamfered) corners. Masonry details include brick window hoods and courses parged and painted to appear like stone. The first story belt course along the street facing facades is precast concrete or stone. Uniquely, the home retains its original slate tile roof and five brick chimneys. The home lacks common ornate Italianate details such as cornices and eave brackets. The structure is first depicted in the 1897 Sanborn map as a two-story brick masonry dwelling with a slate roof with various single-story wood frame porches along each elevation with roofing made of non-combustible material, likely metal (Figure 4). By 1913, the rear (west) elevation porch was replaced with a two-story wood frame porch with roofing made of a non-combustible material, likely metal (Figure 4). By 1939, the south elevation porch was raised to two stories with the upper story enclosed (Figure 5). The second story was enclosed and the first story partially enclosed by the 1980s (Figure 8). The residence was built for Reverend Thomas R. Welch who was a prominent Mason and served as the pastor of Little Rock’s First Presbyterian Church, at 800 Scott Street, for 25 years. Upon his death, Welch left the home to the directors of the Southwestern Presbyterian University in Tennessee. In 1892, the university sold the house to Lewis W. Cherry who was in the ice manufacturing business and later became president of the Peoples Building and Loan and president of the State National Bank in Little Rock. After Cherry’s death in 1922, his widow occupied the house until her death in 1957. The home was later converted to apartments. In 1984, the First Lutheran Church, at 314 E 8th Street, received a Conditional Use Permit to convert the structure to office space and utilize the interior land of Block 42 for shared parking between the church, the Winthrop Rockefeller Foundation, and J. Tucker Morse. The Welch-Cherry House was leased by J. Tucker Morse and RPM until recently. The church plans to continue the use of the home as office space. Previous Action On May 30, 2024, a COC (HDC2024-022) was issued to First Lutheran Church for exterior masonry and wood repairs, installation of handrail on front pathway steps, porch repairs, concrete walkway replacement, box gutter repairs, fencing repair, and HVAC replacement and screening. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 4 On January 25, 2017, a COC (HDC2017-001) was issued to the First Lutheran Church for replacement of the slate roof with architectural shingle and exterior wood repair. On August 16, 2002, a COA (HDC2002-010) was issued to the First Lutheran Church for a wood side ADA ramp on the south porch facing the shared parking. On December 6, 1990, a COA (HDC1990-010) was denied for signage. On April 5, 1984, a COA (HDC1984-004) was issued to the First Lutheran Church for restoration and repair, rear (west) porch alterations and enclosure, and shared parking lot design for Block 42. No previous actions were found on this site. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 5 Sanborn Maps Figure 3. 700 S Rock Street, 1913, Sanborn Map, Little Rock. Figure 4. 700 S Rock Street, 1897, Sanborn Map, Little Rock. Figure 5. 700 S Rock Street, 1939, Sanborn Map, Little Rock. Figure 5. 700 S Rock Street, 1950, Sanborn Map, Little Rock. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 6 Historic Photographs & Drawings C. EXISTING CONDITIONS: See site photos (Attachment A) and application packet (Attachment B). The application packet includes cover letter, application, architectural plans, and email correspondence related to a state conservation easement, etc. Figure 6. Welch-Cherry House, 1978, QQA architectural resource survey. Figure 7. Welch-Cherry East Elevation Drawing, Allison Moses Reddin, 1984. Figure 6. Welch-Cherry, approved alterations to south elevation, Allison Moses Reddin, 1984. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 7 The property owner has applied for a Historic Preservation Restoration Grant (HPRG) Option 2 with the Arkansas Historic Preservation Program for the same scope of work. The property has an active conservation easement held by the State of Arkansas. D. NEIGHBORHOOD COMMENTS: The time of distribution, there were no comments regarding this application. All owners of properties located within 200 feet of the site and all neighborhood associations registered with the City of Little Rock that surround the site were notified of the public hearing. E. ANALYSIS: Rear Enclosed Porch Alteration The application proposes to remove existing lattice panels and metal floor-to-ceiling window wall system installed in the 1984-1985 restoration and rehabilitation of the property. The porch enclosure system will be replaced with wood (Spanish cedar) one- over-one non-operable windows with exterior mullions, arranged two and three per bay. Wood horizontal siding and trim in the same dimensions and exposure are proposed beneath the windows to match the south elevation porch. The proposal includes the restoration of all existing and original chamfered porch columns, pilasters, and remaining brackets. One existing column that is non-original will be replaced with a column that matches the originals in design and material. The four (4) existing brackets are proposed to be relocated from the second story to the first story, south elevation, of the porch. The brick masonry porch foundation will be deconstructed and rebuilt for stabilization with concrete footings and CMU (concrete masonry unit) bearing, with brick veneer salvaged from the existing foundation. It is staff’s understanding that the existing horizontal siding covering the eaves, soffit, fascia, and foundation of the rear porch will be removed. These porch elements will be replaced with wood boards of the appropriate dimensions to be compatible with the other porches on the structure. Staff finds the proposed rear porch alterations are mostly consistent with the Design Guidelines, specifically Section 4.13(5). The proposed alterations preserve identified historic porch features, such as the columns and brackets. The proposed non-historic elements will be installed behind existing architectural details and the existing large single pane windows will be replaced with pairs and groupings of one-over-one wood April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 8 windows dimensionally compatible to the existing openings. Staff finds that the proposed wood siding beneath the windows are too similar to the wood siding of the historically enclosed south elevation porch and recommends the use of simple solid panels for this element. Examples of enclosed secondary porches in this configuration in the MacArthur Park Historic District are shown below: Figure 9. Holtzman-Vinsonhaler House, 500 E 8th, 2023. Figure 10. 601 Rock Street, 2023. Figure 11. Hanger House, 1010 Scott Street, 2023. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 9 Staff finds the proposal is inconsistent with standard 3 of the Secretary of Interior Standards for Rehabilitation: “Each property shall be recognized as a physical record of its time, place, and use. Changes that create a false sense of historical development, such as adding conjectural features or architectural elements from other buildings, shall not be undertaken.” Staff finds the proposal is consistent with standard 9 of the Secretary of Interior Standards for Rehabilitation: “New additions, exterior alterations, or related new construction shall not destroy historic materials that characterize the property. The new work shall be differentiated from the old and shall be compatible with the massing, size, scale, and architectural features to protect the historic integrity of the property and its environment.” Accessibility Ramp The application proposes the removal of the existing wood accessibility ramp on the south elevation and replacement with a concrete ramp and metal handrails. The ramp will connect the south porch to designated handicap parking. Staff finds the proposed accessibility ramp is mostly consistent with the Design Guidelines, specifically Section 4.30, regarding material and screening. The ramp is located on a secondary façade, is visible from Rock Street, and is made of concrete rather than wood. Staff recommends a wood accessibility ramp in consideration of the structure’s architectural style, historic use, and the ability to be more easily removed. Concrete accessibility ramps are more appropriate on commercial and institutional structures that are an extension of the sidewalk to a storefront or entrance. Staff finds the proposal is inconsistent with standard 9 of the Secretary of Interior Standards for Rehabilitation: “New additions, exterior alterations, or related new construction shall not destroy historic materials that characterize the property. The new work shall be differentiated from the old and shall be compatible with the massing, size, scale, and architectural features to protect the historic integrity of the property and its environment.” Porch Handrails The application proposes the installation of black, metal handrails with lamb’s tongue ends along the porch steps of the front and south porches. One handrail is proposed for the front porch while retaining existing wood rails, two handrails are proposed for the south porch. The handrails are required by building code. Staff finds the proposed accessibility ramp is consistent with Guideline 4.13(7). The April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 10 proposed handrails are simple and subordinate in design and compatible with the historic attributes of the property. Staff finds the proposal is consistent with the SOI Standards, specifically Standard 9: “New additions, exterior alterations, or related new construction will not destroy historic materials, features, and spatial relationships that characterize the property. The new work will be differentiated from the old and will be compatible with the historic materials, features, size, scale and proportion, and massing to protect the integrity of the property and its environment.” F. STAFF RECOMMENDATION: Staff recommends the approval of the application, as submitted, with the following conditions: 1. Simple, solid panels shall be used below the windows of the proposed rear enclosed porch to avoid conjecture with the early-20th century south elevation porch. 2. The accessibility ramp shall be composed of wood with wood railings and be screened with landscaping to reduce visibility, as viewable from Rock Street. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 11 Attachment A: Site Photos Figure 12. 700 S Rock, south and west elevations, rear porch, 2023. Figure 13. 700 S Rock, west elevation, rear porch, 2023. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 12 Figure 14. 700 S Rock, interior, rear porch, 2023. Figure 15. 700 S Rock, south elevation, side porch and existing accessibility ramp 2023. April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 13 Attachment B Application Packet 1 8 5 8 S O U T H A R C H S T R E E T Ÿ L I T T L E R O C K , A R K A N S A S 7 2 2 0 6 B : 5 0 1 . 3 5 0 . 6 8 2 6 E D W A R D S E R G E A N T @ S B C G L O B A L . N E T ED SERGEANT, AIA - PRINCIPAL Date: February 6, 2025 m: 501.350.6826 e: edwardsergeant@sbcglobal.net Re: WELCH-CHERRY HOUSE - Cover letter 700 South Rock Street / Little Rock, Arkansas 72202 CERTIFICATE OF APPROPRIATENESS for the Little Rock Historic District Commission SA job no. 23033 PROJECT RATIONALE Stabilization and restoration of the existing historic structure by the Owner, First Lutheran Church. All work shall be in compliance with applicable codes and preservation standards. INTENT OF USE Continue leasing for office use. SCOPE OF WORK (SOW) The structure was built circa 1881. The Building was listed in the National Register of Historic Places on July 25, 1977. Historic Preservation Conservation Easement PU2830 was approved August 15, 2016. Conditional Use Permit Z-4176 was granted in 1984 to allow use for professional offices of the property zoned R4A. All work shall be in compliance the Little Rock Historic District Commission, HPRG Option 2 Grant, existing Conservation Easement, Arkansas Rehabilitation Tax Credit, Secretary of the Interior’s Standards for Rehabilitation, all applicable codes including but not limited to the IBC (International Building Code) and ADA (Americans with Disabilities Act). The SOW will retain as much of the original historic fabric as possible. 1. ROOF: Repair existing roof assembly including flashing, box gutters, downspouts and eaves. Provide theftproof splash blocks. For pictures see Home Buyer’s Protection attachment and inspection by Bray Sheet Metal. 2. MASONRY REPAIR AND STABILIZATION: According to PU2830, Dr. Welch was a prominent mason which may be a reason all exterior walls are 4 course load bearing brick. Several interior walls are similar construction. Provide stabilization for house and porches including but not limited to walls, foundations and rebuild 2 leaning chimneys. See Attachment 20 below for leaning chimneys. All brick walls are load bearing masonry. All porches indicate vertical foundation movement. Include replacing non-matching mortar in color and strength. Eliminate moisture infiltration. Flashing shall be recessed in brick joints, not adhered to brick. See Home Buyer’s Protection attachment and Roberts McNutt attachment. 4. REAR (WEST) ENCLOSED PORCH: Replace foundation which is settling – see attachments 3 and 4a below. Horizontal lines drawn indicate how much movement has occurred since 2007 in attachment 4a. Grade beam visible at column F6 (southwest corner) is deteriorating. Existing windows added in 1985 are breaking and cracking due to stress from movement on the windows presenting a hazardous condition (see 2nd floor glass in attachment 3). The 1985 windows do not blend well with the overall historic nature of the house. Sanborn maps in Attachments 30 thru 32 indicate evolution of the west and south porch. The west was originally a one story open porch. A 2nd story was constructed by 1913. The porch was not enclosed until 1985. Design shall be reviewed and approved by all applicable agencies. See Attachments 3 & 8 through 12b for existing photos. See Exterior Elevations in Supplemental Info. The windows are proposed to provide some sense of scale and proportion to blend with the original but will not match. Vertical proportions are proposed so the openings are in scale with vertical proportions similar to the original so blend well with the house. See attachments 12a and 12b below for existing - the large openings are out of scale so need some division. No operable sashes are proposed, simply divide the openings as shown. They are different than the original but much simpler design. The windows are oriented south and west for which the proposed openings will allow easier sun control with window shades. Columns remain in place which references the fact there used to be larger openings. Also would prefer that the existing brackets align on the 1st floor like the other 3 porches as shown on the drawings. The brackets are early construction but not original since the 2nd story was not added later than original construction. 3. FRAMING AND FINISHES: Stabilize for house and porches. Eliminate moisture infiltration & repair damage. See attachments 1, 3 thru 12, 13 thru16 & 19 for existing photos. See Home Buyer’s Protection attachment. 5. EXTERIOR WOOD: Repair and paint existing exterior, replace only if repair is not possible or materials are missing. Repair Eaves. See all attached photos and Home Buyer’s Protection attachment. 6. WINDOWS: All original shall remain. Repair sealant to eliminate interior moisture penetration. Repair storm windows, clean and reinstall after painting. 9. REPAIR INTERIOR DAMAGE DUE TO LACK OF MOISTURE STABILIZATION: Repair all existing finishes and substrate. See attachment 17 for damage to lincrusta wall covering. 10. LIGHTING / EXTERIOR: Add exterior for safety from parking to south entrance ramp and front entrance. 11. LIGHTING / INTERIOR: Add general (ambient) lighting where missing without. Upgrade existing lights. 12. ELECTRICAL SYSTEMS: Repair in compliance with applicable codes and provide where insufficient for comfort. See Home Buyer’s Protection attachment in Condition Assessment / Master Plan. 13. HVAC: Repair in compliance with applicable codes and provide where insufficient for comfort. See Home Buyer’s Protection attachment in Condition Assessment / Master Plan. Stabilize basement temperature to prevent freezing and provide automatic vent closers at vent openings. 14. PLUMBING: Repair in compliance with applicable codes. See Home Buyer’s Protection attachment in Condition Assessment / Master Plan. 6. SITE: a. ADA COMPLIANCE: Replace existing south ramp due to wear. Add handrails for front (east) porch. Provide striping connecting ramp to driving lane and handicap parking sign at designated parking space. Move handicap parking space next to ramp, add handicap parking sign and add logo on asphalt. Add code compliant handrails. See attachments 4,5,7,10,15, 17,19. b. SIDEWALKS: Replace existing for safe travel where damaged including the front steps. See attachment 20. c. FENCES: Repair existing. d. SITE STONE RETAINING WALLS: Repair existing. e. SITE DRAINAGE: Slope site away from exterior walls, provide below grade drainage to prevent water from entering basement. f. HISTORIC MARKER: Add new pole mounted for better visibility from the street, keep existing mounted to the sidewalk. GENERAL NOTES 1. Work shall include scope for compliance with all applicable codes. 2. NOT INCLUDED: Hazardous Material Survey and abatement (which shall be by owner), historic paint color analysis and all other testing and inspections. 1 8 5 8 S O U T H A R C H S T R E E T Ÿ L I T T L E R O C K , A R K A N S A S 7 2 2 0 6 B : 5 0 1 . 3 5 0 . 6 8 2 6 E D W A R D S E R G E A N T @ S B C G L O B A L . N E T ATTACHMENTS: 1. EAST ELEVATION (FRONT) 2. HISTORIC MARKER 3. SOUTH ELEVATION 4. SOUTH ELEVATION 4a. SOUTH ELEVATION circa 2007 5. SOUTH PORCH 6. SOUTH PORCH 7. SOUTH ELEVATION RAMP 8. WEST ELEVATION 9. WEST PORCH FOUNDATION 9a. WEST PORCH GRADE BEAM @ SOUTHWEST CORNER 10. WEST PORCH NORTHWEST CORNER 11. WEST PORCH NORTHWEST CORNER 12. WEST PORCH NORTH ELEVATION 12a. WEST PORCH - SOUTH INTERIOR ELEVATION 12b. WEST PORCH – WEST INTERIOR ELEVATION 13. NORTH PORCH – EAST AREA 14. NORTH PORCH – NORTHEAST CORNER 15. NORTH PORCH – NORTHWEST CORNER 16. NORTH PORCH – NORTHWEST FOUNDATION CORNER 17. LINCRUSTA 18. EAST (FRONT) GATE AND HANDRAIL 19. FRONT STEPS (EAST FAÇADE) 20. DAMAGED SIDEWALKS – NORTHEAST CORNER 30. SANBORN MAP 1897 31. SANBORN MAP 1913 32. SANBORN MAP 1939 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK HISTORIC DISTRICT COMMISSION ON AN APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS To all owners of land lying within 200 feet of the boundary of property at: LEGAL DESCRIPTION: W40’ of 10 & ALL 11 & 12 BLK 2 11 1N 12W STREET ADDRESS: 700 South Rock Street, Little Rock, Arkansas 72202 OWNED BY: First Lutheran Church, Little Rock, Arkansas 72202 NOTICE IS HEREBY GIVEN THAT an application for a Certificate of Appropriateness on the above described property has been filed with the City of Little Rock’s Department of Planning and Development requesting the following changes: Stabiliza(on of exis(ng circa 1881 house, including exterior load bearing masonry, roof, trim, interior due to moisture infiltra(on, all building systems and improve accessibility in compliance with the ADA. Replace infill window walls in rear (southwest) porch. The Owner, First Lutheran Church, will con(nue to lease as office space in compliance with Condi(onal Use Permit Z-4176. A Public Hearing on said application will be held by the Historic District Commission at: Little Rock City Hall, 500 West Markham Street, (location address) on April 3, 2025 (date) at 4 pm (time). ALL PARTIES IN INTEREST MAY APPEAR and be heard at said time and place or may notify the Little Rock Historic District Commission of their views on this matter by letter. All persons interested in this application are invited to call or visit the Department of Planning and Development to review the application with Commission Sta]. The City of Little Rock complies with all civil rights provisions of federal laws and related authorities that prohibit discrimination in programs and activities receiving federal financial assistance. The City of Little Rock does not discriminate on the basis of race, color, creed, religion, sex, national origin, age, disability, income status, marital status, sexual orientation, gender identity, genetic information, political opinions or a@iliation, in admission or access to and treatment in the City’s programs and activities, as well as the city’s hiring or employment practices. Complaints of alleged discrimination and inquiries regarding the City's nondiscrimination policies may be directed to: Title VI Coordinator, 500 West Markham Street, Little Rock, AR 72201, 501- 371- 4475. This notice is available from the Title VI Coordinator in large print or recording. Free language assistance for those with Limited English Proficiency is available upon request. La ciudad de Little Rock cumple con todas las disposiciones de derechos civiles de los estatutos federales y autoridades relacionadas que prohíben la discriminación en programas y actividades que reciben asistencia financiera federal. La ciudad de Little Rock no discrimina por motivos de raza, color, credo, religión, sexo, origen nacional, edad, discapacidad, estado de ingresos, estado civil, orientación sexual, identidad de género, información genética, las opiniones políticas o afiliación, en la admisión o acceso y tratamiento en los programas y actividades de la ciudad, así como de contratación de empleados de la ciudad. Las quejas de supuesta discriminación y consultas sobre la politica antidiscriminatoria de la ciudad pueden ser dirigidas a Coordinador del Titulo VI, 500 West Markham Street, Little Rock, AR 72201, 501-371-4475. AFFIDAVIT I hereby certify that I have notified all the property owners as reflected on the abstract company’s list and all those that are not reflected on that list that I have knowledge of within 200 feet of the above-described property that a Certificate of Appropriateness application has been filed regarding the subject property and that a Public Hearing has been scheduled to be held before the Little Rock Historic District Commission at the time and place described on the notice. (Edward T. Sergeant) February 27, 2025 Applicant (Owner or Authorized Agent): Date: Historic District.docx Page 6 of 7 Revised 06/05/2025 1 Ratzlaff, Hannah K. From:Edward Sergeant <edwardsergeant@sbcglobal.net> Sent:Monday, February 24, 2025 5:43 PM To:Ratzlaff, Hannah K. Subject:Review for facade easement compliance - Welch-Cherry House - 700 South Rock Street, Little Rock EXTERNAL EMAIL - This email was sent by a person from outside your organization. Exercise caution when clicking links, opening attachments or taking further action, before validating its authenticity. Hi Hannah, Thank you for meeting with me for the Pre-Application Review, very helpful. Please see below for review by Mollie Waldon regarding facade easement. Ed Begin forwarded message: From: Mollie Waldon <Mollie.Waldon@arkansas.gov> Subject: Re: Welch-Cherry House - 700 South Rock Street, Little Rock Date: February 4, 2025 at 10:55:41 AM CST To: Edward Sergeant <edwardsergeant@sbcglobal.net> Good morning, I'm sorry for the delay in response. This slipped through amid a busy last few weeks. Regarding the proposed alterations relevant to the easement- they were initially looked at last year and appeared in line with design preferences, so our easement coordinator and I were happy with them. Technically for HPRG projects more of that review just goes to me, even when there is an easement, but we do talk. Thank you for sharing the plans again to check for review. If the grant portal supports the file size, it would be nice to have the plans showing the elevations of the porch work in the grant application. Best, MOLLIE WALDON Technical Assistance Coordinator Arkansas Historic Preservation Program Division of Arkansas Heritage 1100 North Street Little Rock, AR 72201 mollie.waldon@arkansas.gov p: 501.324.9881 | f: 501.324.9184 ArkansasPreservation.com 2 From: Edward Sergeant <edwardsergeant@sbcglobal.net> Sent: Tuesday, January 21, 2025 10:18 AM To: Katherine Nash <Katherine.Nash@arkansas.gov> Cc: Mollie Waldon <Mollie.Waldon@arkansas.gov> Subject: Re: Welch-Cherry House - 700 South Rock Street, Little Rock Hi Katherine and Mollie, The rear enclosed porch is being changed some as I mentioned in item 2 below. Here are existing pictures followed by proposed. Thank you, Ed EDWARD SERGEANT, AIA SERGEANT ARCHITECTURE, PLLC 1858 SOUTH ARCH STREET LITTLE ROCK, AR 72206 B: 501.350.6826 E: edwardsergeant@sbcglobal.net www.sergeantarchitecture.com 3 4 5 6 On Jan 21, 2025, at 8:41 AM, Katherine Nash <Katherine.Nash@arkansas.gov> wrote: Ed, What exactly do you mean by updating the easement? We don’t revise the legal contract unless something was done incorrectly. As far as drawings, those would be Mollie’s purview since it is an HPRG grant. Thanks, KATHERINE NASH Technical Services and Easement Coordinator Arkansas Historic Preservation Program Division of Arkansas Heritage 1100 North Street Little Rock, AR 72201 katherine.nash@arkansas.gov p: 501.683.6672 | f: 501.324.9184 ArkansasPreservation.com <image001.jpg> From: Edward Sergeant <edwardsergeant@sbcglobal.net> Sent: Friday, January 17, 2025 7:03 AM To: Katherine Nash <katherine.nash@arkansas.gov> Cc: Mollie Waldon <mollie.waldon@arkansas.gov>; Dean Vlisides <cvlisides@gmail.com>; Mark Hagge <mhagge58@gmail.com> Subject: Welch-Cherry House - 700 South Rock Street, Little Rock Hello Katherine, When should we update the facade easement? We are in process of filing for the HPRG Grant, review by the Little Rock Historic District Commission and State Tax Credits. The project schedule is below. I have drawings I can share with you any time. The Scope of Work (SOW) is: 1. Miscellaneous roof repairs including a chimney rebuild. 2. Stabilization of the rear enclosed porch which has settlement problems. Replacement of existing c. 1985 aluminum storefront windows and infill sill walls is also proposed. Replacement would be for windows that blend better with the original house but simpler design. The proposed windows would also provide better interior light since exterior walls face south and west. Thank you, Ed 7 EDWARD SERGEANT, AIA SERGEANT ARCHITECTURE, PLLC 1858 SOUTH ARCH STREET LITTLE ROCK, AR 72206 B: 501.350.6826 E: edwardsergeant@sbcglobal.net www.sergeantarchitecture.com REVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSAS 700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASNOT FOR CONSTRUCTIONW E L C H - C H E R R Y H O U S E CERTIFICATE OF APPROPRIATENESS APPLICATION DATE: FEBRUARY 26, 2025 DATE: FEBRUARY 26, 2025W E L C H - C H E R R Y H O U S ETITLE SHEETCERTIFICATE OF APPROPRIATENESSAPPLICATIONA0.0 GENERAL PROJECT NOTES 1. ALL EXISTING CONSTRUCTION SHALL REMAIN UNLESS INDICATED OTHERWISE. 2. ALL NOTES ARE FOR NEW SCOPE OF WORK. WHERE EXISTING CONSTRUCTION MUST BE INDICATED FOR REFERENCE, IT SHALL BE NOTED AS "EXISTING". 3. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS SHALL ESTABLISH LOCATION OF ALL PARTITIONS. LARGER SCALE DRAWINGS HAVE PRIORITY OVER SMALLER SCALE DRAWINGS. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES IN THE DRAWINGS BEFORE PROCEEDING WITH CONSTRUCTION. 4. NOTES TO "ALIGN" SHALL MEAN TO ALIGN FINISHED FACE OF PARTITION UNLESS OTHERWISE NOTED AND SHALL HAVE PRIORITY OVER A DIMENSIONED LOCATION. 5. PROVIDE WOOD BLOCKING AS SHOWN OR AS REQUIRED FOR ATTACHMENT OF WALL MOUNTED HARDWARE, TOILET ACCESSORIES, CASEWORK, MILLWORK, FINISH CARPENTRY AND WHEREVER ELSE IT MAY BE REQUIRED FOR THE SECURE ATTACHMENT OF ADJOINING WORK. 6. PLAN DIMENSIONS SHOWN ARE TO FACE OF STUD, UNLESS NOTED OTHERWISE ON DETAILS. 7. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTS. WORK PERFORMED WITHOUT CLARIFICATION FROM ARCHITECT IS ENTIRELY AT CONTRACTOR'S RISK. 8. SALVAGE EXISTING MATERIALS FOR RE-USE INCLUDING BUT NOT LIMITED TO SIDING, DOORS, WINDOWS, TRIM, FINISHED FLOOR, BEAD BOARD CEILING. Name Elevation FLOOR ELEVATION A101 1 SIM 0 OFFICE 1 A101 SIM DETAIL KEY CENTERLINE DOOR TAG GRID TAG ROOM TAG BUILDING AND WALL SECTION CEILING ELEVATION PARTITION TYPE WINDOW TYPE 8'-6" AFF A1.0 1 ELEVATION TAGDRAWING NUMBER SHEET NUMBER DRAWING NUMBER SHEET NUMBER ROOM NUMBER DRAWING NUMBER SHEET NUMBER CONTROL JOINT J ACCESSORY TAG 101 1 A NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA0.1W E L C H - C H E R R Y H O U S EPROJECT INFORMATIONDATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATIONSHEET LIST SHEET NO.SHEET NAME A0.0 TITLE SHEET A0.1 PROJECT INFORMATION A0.2 SITE PLAN A1.1 FIRST FLOOR PLAN A1.2 SECOND FLOOR PLAN A1.3 ROOF PLAN A3.1 EAST ELEVATION (FRONT) A3.2 SOUTH ELEVATION A3.3 WEST ELEVATION A3.4 NORTH ELEVATION 1 1/2" 1'-0" SYMBOL LEGEND 0 5 101 NORTH A3.11 A3.2 A3.3 A3.4 1 1 1 A0.01 PROPERTY LINE PROPERTY LINEPROPERTY LINEPROPERTY LINEEAST 7TH STREET ROCK STREETFIRST LUTHERAN CHURCH SANCTUARY (1) HANDICAP PARKING SPACE ALIGN STRIPING WITH RAMP EXISTING STRIPES TO REMAIN REMOVE EXISTING STRIPING SHOWN DASHED THESE LOCATIONS 9' - 0" ACCESS AISLE (VAN) 10' - 3" +/-THREE 27'-3" +/- EQUAL SPACES TREE LIGHT LIGHT FOUNTAIN --NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA0.2W E L C H - C H E R R Y H O U S ESITE PLANDATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATION 1/8" 1'-0"1 SITE PLAN 0 5 101 NORTH A3.11 A3.3 A3.4 1 1 1 4 2 3 ABC 5FDE 6 8 7 10 G 9 J HK 0' - 0" ENTRY 100 OFFICE 101 OFFICE 103 ELECTR. 100a OFFICE 102 ENTRY 115RESTR. 116 CONFERENCE 106 OFFICE 104 HALL 110 STAIR 112 CLO. 110a ENTRY 111 BREAK 113RESTR. 114 OFFICE 105 B.5 (2) 30"x95"(2) 30"x95" (1) 32"x95" (3) 29"x95" (3) 29"x95" UP KEEP WATER OUT OF BASEMENT VENT WELL: REPAIR BRICK, PROVIDE ATTACHMENT OF BRICK TO WALL, REPAIR CAST IRON VENT COVER E.5 RAMP DN 1:12 SLOPEDN ADD 1 HANDRAIL ADD 2 LAMBS TONGUE HANDRAILS EQUA TO SUBURBAN STEEL SUPPLY COMPANY REPLACE EXISTING RAMP WITH CONCRETE RAMP, STAMPED CONRETE FINISHM, SLOPE 1:12 NEW CONSTRUCTION SHADED GRAY EXISTING CONSTRUCTION NOT SHADED A0.01 DNNEW COLUMN TO MATCH EXISTING STABILIZE AND RESTORE EXISTING COLUMNS PERFORATED DRAIN PIPE WRAPPED WITH FILTER FABRIC IN SELECT DRAINAGE GRAVEL BELOW GRADE , GRASS COVER 5' - 3" FACE OF CURB EXISTING PORCH FOUNDATION INDICATES VERTICAL MOVEMENT - REPLACE FOUNDATION WITH BRICK VENEER TO MATCH EXISTING. REPAIR EXISTING WOOD FLOOR FRAMING ASSEMBLY, REPLACE DAMAGED CONSTRUCTION DS DS DS DS DS DS DS DS L1: 2,592 S.F. L2: 2,716 S.F. TOTAL: 5,308 S.F. CONDITIONED SPACE EXISTING GROUND MOUNTED HISTORIC MARKER TO REMAINADD HISTORIC MARKER FRONT PORCH NORTH PORCH SOUTH PORCH DN HANDICAP PARKING SIGN REPAIR EXISTING GAS LIGHT SLOP E S U R F A C E T O D R A I N SLOPESLOPEEXISTING SLOPESLOPESLOPE TO DRAIN ACROSS SIDEWALKS SLOPE TO DRAINACROSS SIDEWALKSSLOPE TO DRAIN ACROSS SIDEWALKS REPLACE THIS SIDEWALK DUE TO DAMAGE LIGHT MULBERRY HACKBERRY MULBERRY SPLASHBLOCKS AT ALL DOWNSPOUTS, DRAIN TO TOP OF WALK AT THIS LOCATION 4" DIAMETER OPENING THROUGH RAMP, BOTTOM OF OPENING AT DRAINAGE VALLEY SIDEWALK TO REMAIN REPLACE THIS SIDEWALK DUE TO DAMAGE AND RAISED DUE TO TREE ROOTSADD 1 HANDRAIL SIMILAR TO SOUTH PORCH STAIR REPAIR GATE REPAIR EXISTING STEPS TO LEVEL, REPLACE ONLY IF NOT REPAIRABLE VALL E Y VALLEY NEAR CURB, AVOID TREE ROOT ZONE REPOINT STONE, GRAPEVINE STYLE STRIKE JOINTS EXISTING SIDEWALK TO REMAIN REPAIR PORCH FOUNDATION & REPLACE WOOD INFILL WITH BRICK TO MATCH EXISTING PORCH FOUNDATION INDICATES VERTICAL MOVEMENT - REPAIR PORCH FOUNDATION INDICATES VERTICAL AND HORIZONTAL MOVEMENT - REPAIR REPAIR WOOD INFILL UP REPAIR LINCRUSTA WALL COVERING & PAINTED TRIM THIS ROOM DUE TO MOISTURE DAMAGE REPAIR ALL EXISTING FENCES EAST 7TH STREET ROCK STREETPROPERTY LINE PROPERTY LINEREPAIR LINCRUSTA WALL COVERING & PAINTED TRIM THIS ROOM DUE TO MOISTURE DAMAGE DN DN REPLACE ALL EXISTING HVAC SYSTEMS ADD 2 LAMBS TONGUE HANDRAILS EQUA TO SUBURBAN STEEL SUPPLY COMPANY -- 1' - 0"3' - 4"1' - 0"2"1' - 1" 1' - 2"1'-0" FACE OF RISER 1'-0" FACE OF RISER2" CLEARDN OUTER EDGE OF HANDRAIL NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA1.1W E L C H - C H E R R Y H O U S EFIRST FLOOR PLANDATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATION 1/4" 1'-0"1 1ST FLOOR PLAN A3.11 A3.3 A3.4 1 1 1 4 2 3 ABC 5FDE 6 8 7 10 G 9 J HK 13' - 2"12' - 0"DNDN HALL 200 STAIR 2 210 RESTR. 211 RESTR. 207c HALL 209 OFFICE 201 OFFICE 202 CONFERENCE 207 OFFICE 206 OFFICE 205 OFFICE 204 OFFICE 203 B.5 0 5 101 NORTH (2) 30"x91"(2) 30"x91" (1) 32"x91" (3) 29"x91" (3) 29"x91" E.5 NEW CONSTRUCTION SHADED GRAY EXISTING CONSTRUCTION NOT SHADED A0.01 CLO 201a CLO. 207a BREAK 207b BREAK 209a UP DN --NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA1.2W E L C H - C H E R R Y H O U S ESECOND FLOOR PLANDATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATION 1/4" 1'-0"1 2ND FLOOR PLAN GENERAL ROOF NOTES 1. FIELD VERIFY ALL DIMENSIONS BEFORE CONSTRUCTION. 2. ALL ROOF SLOPES SHALL MATCH ORIGINAL UNLESS NOTED OTHERWISE. 3. NEW ROOF SHALL MATCH EXISTING. A3.11 A3.2 A3.3 A3.4 1 1 1 1 4 2 3 ABC 5FDE 6 8 7 10 G 9 J HK B.5 E.5 A0.01 DS ADD DOWNSPOUT AT LOW GUTTER ELEVATION TO ELIMINATE STANDING WATER - LOCATE ON CENTERLINE GRID J STABILIZE ALL EXISTING GUTTERS AND EAVES - SEE 1/A3.1 DS DS DS DS DS DS DS DS DS BELOW DS BELOW REBUILD EXISTING CHIMNEY (LEANING) REBUILD EXISTING CHIMNEY (LEANING) ALL LOCATIONS WHERE DRAINAGE IS NOT POSITIVE TO DOWNSPOUTS, ADD TPO MEMBRANE ON TAPERED INSULATION TO PROVIDE POSITIVE DRAINAGE GUTTERGUTTERGUTTER GUTTER GUTTER GUTTER GUTTER GUTTERGUTTERGUTTERGUTTER DS DS ROOF HATCH CHIMNEY CHIMNEY CHIMNEY -- STABILIZE ALL EXISTING GUTTERS AND EAVES - SEE 1/A3.1 NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA1.3W E L C H - C H E R R Y H O U S EROOF PLANDATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATION 1/4" 1'-0"1 ROOF PLAN 1ST FLOOR 0' - 0" 2ND FLOOR - EAST 13' - 2" TOP OF WALL EAST 25' - 2" TOP OF WALL WEST 23' - 8" 2ND FLOOR - WEST 12' - 0" 1 423 10 STABILIZE & REPAIR ALL PORCHES INCLUDING FOUNDATIONS STABILIZE ALL PORCHES ADD HANDRAIL REPLACE EXISTING RAMP & HANDRAILS -SEE 1/A3.3 WHERE BOX GUTTERS INDICATE VERTICAL MOVEMENT AND NOT DRAINING TO DOWNSPOUNTS - STABILIZE FRAMING OF EXISTING BOX GUTTERS FROM INSIDE ATTIC & ADD DOWNSPOUTS NOTED ON ROOF PLAN BASEMENT -9' - 0" BASEMENT BEYOND REPLACE PENDANT LIGHT (EXISTING IS NON-HISTORIC) (2) RECESSED CAN LIGHTS IN BEAD BD. CEILING - CENTER BETWEEN COLUMNS REPAIR SEALANT AROUND ALL WINDOWS - SEE GENERAL NOTES THIS SHEET REPAIR ALL HEADERS & PAINT CLEAN ALL PAINTED BRICK HEADERS AT OPENINGS, DO NOT PAINT CLEAN ALL PAINTED BRICK FLOOR LINE LEDGES, DO NOT REPAINT CLEAN ALL PAINTED BRICK FLOOR LINE LEDGES, DO NOT REPAINT DS DS CLEAN ALL PAINTED FLOOR LINE LEDGES, DO NOT PAINT CLEAN ALL PAINTED FLOOR LINE LEDGES, DO NOT PAINT GENERAL EXTERIOR NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS ARE SOUND AND IN GOOD CONDITION. SHOULD REPAIRS BE NEEDED, NEW CONSTRUCTION IS SHOWN FOR METHODS TO BE USED. ALL EXISTING MATERIALS SHALL BE RE-USED OR SALVAGED FOR RE-USE WHERE POSSIBLE UNLESS NOTED OTHERWISE. 2. PROVIDE MOCK-UP "IN PLACE" OF ALL WORK EXPOSED TO VIEW FOR APPROVAL BY ARCHITECT BEFORE PROCEEDING. 3. STABILIZE REAR (WEST) PORCH STRUCTURE INCLUDING FINISHES. ELIMINATE MOISTURE INFILTRATION. THIS INCLUDES PORCH FOUNDATION WHICH INDICATES VERTICAL MOVEMENT. NOTE: ALL BRICK WALLS OF HOUSE ARE LOAD BEARING MASONRY. 4. REPAIR EXISTING ORIGINAL MATERIALS RATHER THAN REPLACE. REPLACE ONLY IF NOT REPAIRABLE IN COMPLIANCE WITH NATIONAL PARK SERVICE STANDARDS. FINISH DIMENSIONS SHALL MATCH EXISTING UNLESS NOTED OTHERWISE. 5. CLEAN, STABILIZE, REPAIR AND PAINT EXTERIOR WOOD WHERE INDICATED ON THE DRAWINGS. REMOVE ALL LOSE PAINT. USE ABATRON FOR WOOD REPAIR. SAND FOR A SMOOTH CONSISTENT SURFACE. PRIME WITH OIL BASED PRIMER. PROVIDE 2 FINISH COATS WITH SEMI-GLOSS FINISH. PAINT SHALL BE BEHR MARQUEE EXTERIOR, BEHR ULTRA EXTERIOR OR CLARK + KENSINGTON EXTERIOR. ALTERNATES MAY BE SUBMITTED FOR APPROVAL BEFORE APPLICATION. APPLICATION SHALL BE BY BRUSH, NOT BY SPRAY. 6. REPAIR EXISTING FLASHING WHERE DAMAGED. FLASHING SHALL BE RECESSED COPPER IN MORTAR JOINTS, NOT ADHERED. 7. ALL NEW EXTERIOR WOOD SHALL BE TULIP POPLAR OR SPANISH CEDAR UNLESS NOTED OTHERWISE. 8. ALL NEW WINDOWS AND TRIM SHALL BE SPANISH CEDAR INTERIOR AND EXTERIOR WITH PAINTED FINISH. WIDTH OF ALL MEMBERS SHALL BE SIMILAR TO EXISTING. 9. HANDRAILS SHALL BE EQUAL TO AIDI (ARCHITECTURAL IRON DESIGN INC.) 1-3/4" WIDE ALUMINUM LATERAL SCROLL AND FITTINGS. 10. INSTALL AUTOMATIC VENT CLOSURES FOR ALL VENTS IN EXTERIOR WALLS TO BASEMENT & CRAWL SPACE.NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA3.1W E L C H - C H E R R Y H O U S EEAST ELEVATION (FRONT)DATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATION 3/8" 1'-0"1 EAST ELEVATION (FRONT) 1ST FLOOR 0' - 0" 1ST FLOOR 0' - 0" 2ND FLOOR - EAST 13' - 2" TOP OF WALL EAST 25' - 2" TOP OF WALL WEST 23' - 8" 2ND FLOOR - WEST 12' - 0" ABCFDEB.5 NEW WINDOWS, SIDING AND TRIM THIS AREA - DESIGN SHALL BE REVIEWED AND APPROVED BY ALL APPLICABLE AGENCIES. NON-OPERABLE (FIXED) WINDOWS NEW WINDOWS, SIDING AND TRIM - DESIGN SHALL BE REVIEWED AND APPROVED BY ALL APPLICABLE AGENCIES. NON-OPERABLE (FIXED) WINDOWS EXISTING WINDOWS, SIDING AND TRIM TO REMAIN ON SOUTH STABILIZE ALL PORCHES STABILIZE & REPAIR ALL PORCHES INCLUDING FOUNDATIONS RESTORE EXISTING COLUMNS, & PILASTERS, REPLACE (1) NON-MATCHING STABILIZE & LEVEL FOUNDATION RESTORE EXISTING COLUMNS, & PILASTERS ADD HANDRAIL BASEMENT -9' - 0" RELOCATE (4) EXISTING BRACKETS FROM 2ND FLOOR TO 1ST FLOOR TO MATCH OTHER PORCHES BASEMENT BEYOND EXISTING HANDRAIL REPAIR SEALANT AROUND ALL WINDOWS - SEE GENERAL NOTES THIS SHEET REPAIR ALL HEADERS & PAINT CLEAN ALL PAINTED BRICK HEADERS AT OPENINGS, DO NOT PAINT CLEAN ALL PAINTED BRICK FLOOR LINE LEDGES, DO NOT PAINT CLEAN ALL PAINTED BRICK FLOOR LINE LEDGES, DO NOT PAINT NEW LAP WOOD SIDING TO MATCH EXISTING ON OFFICE 203 ENCLOSED PORCH SOUTH EXTERIOR EXISTING ROOF ASSEMBLY TO REMAIN DS DS DS DS DS WHERE BOX GUTTERS INDICATE VERTICAL MOVEMENT AND NOT DRAINING TO DOWNSPOUNTS - STABILIZE FRAMING OF EXISTING BOX GUTTERS FROM INSIDE ATTIC & ADD DOWNSPOUTS NOTED ON ROOF PLAN BASEMENT VENT 1' - 0" 1' - 0" FACE OF STAIR RISER 5' - 0"NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA3.2W E L C H - C H E R R Y H O U S ESOUTH ELEVATIONDATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATION 3/8" 1'-0"1 SOUTH ELEVATION 1ST FLOOR 0' - 0" 2ND FLOOR - EAST 13' - 2" TOP OF WALL EAST 25' - 2" TOP OF WALL WEST 23' - 8" 2ND FLOOR - WEST 12' - 0" 5687109 NEW WINDOWS, SIDING AND TRIM SIMILAR TO EXISTING SOUTH 2ND LEVEL. STABILIZE FOUNDATION NEW WINDOWS, SIDING AND TRIM THIS AREA - DESIGN SHALL BE REVIEWED AND APPROVED BY ALL APPLICABLE AGENCIES. NON-OPERABLE (FIXED) WINDOWS NEW WINDOWS, SIDING AND TRIM - DESIGN SHALL BE REVIEWED AND APPROVED BY ALL APPLICABLE AGENCIES. NON-OPERABLE (FIXED) WINDOWS RESTORE EXISTING COLUMNS, & PILASTERS, REPLACE (1) NON-MATCHING COLUMN F-8 @ 1ST FLOOR RESTORE EXISTING COLUMNS, & PILASTERS REPLACE EXISIING WOOD RAMP & HANDRAILS WITH CONCRETE RAMP AND PREFINISHED METAL HANDRAILS ADD LAMBS TONGUE HANDRAILS AT STEPS 3' - 0"BASEMENT -9' - 0" BASEMENT BEYOND DS DS DS DS REBUILD EXISTING CHIMNEY, SEE GENERAL ROOF NOTES SHEET A3.1 FOR FLASHING 11"1'-0" TOE OF RAMP 1' - 0"1'-0" TOE OF RAMP 3" CLEAR3' - 0"1' - 0" 11"1'-0" NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA3.3W E L C H - C H E R R Y H O U S EWEST ELEVATIONDATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATION 3/8" 1'-0"1 WEST ELEVATION DS 1ST FLOOR 0' - 0" 2ND FLOOR - EAST 13' - 2" TOP OF WALL EAST 25' - 2" TOP OF WALL WEST 23' - 8" 2ND FLOOR - WEST 12' - 0" F G JH K STABILIZE & REPAIR ALL PORCHES INCLUDING FOUNDATIONS E.5 BASEMENT -9' - 0" BASEMENT BEYOND NEW WINDOWS, SIDING AND TRIM THIS AREA - DESIGN SHALL BEREVIEWED AND APPROVED BY ALL APPLICABLE AGENCIES. NON-OPERABLE (FIXED) WINDOWS NEW WINDOWS, SIDING AND TRIM - DESIGN SHALL BE REVIEWED AND APPROVED BY ALL APPLICABLE AGENCIES. NON-OPERABLE (FIXED) WINDOWS RESTORE EXISTING PILASTER, REPLACE (1) NON-MATCHING COLUMN F-8 @1ST FLOOR RESTORE EXISTING COLUMNS, & PILASTERS DS DS DS DS DS ADD DOWNSPOUT (DS) AT LOW POINT IN GUTTER DS REPAIR SEALANT AROUND ALL WINDOWS - SEE GENERAL NOTES THIS SHEET CLEAN ALL PAINTED BRICK HEADERS AT OPENINGS, DO NOT REPAINT REPAIR ALL HEADERS & PAINT CLEAN ALL PAINTED BRICK FLOOR LINE LEDGES, DO NOT PAINT CLEAN ALL PAINTED BRICK FLOOR LINE LEDGES, DO NOT PAINT WHERE BOX GUTTERS INDICATE VERTICAL MOVEMENT AND NOT DRAINING TO DOWNSPOUNTS - STABILIZE FRAMING OF EXISTING BOX GUTTERS FROM INSIDE ATTIC & ADD DOWNSPOUTS NOTED ON ROOF PLAN REPAIR VENT & INSTALL AUTOMATIC VENT CLOSURE REPAIR & SEAL BASEMENT WINDOWS INFILL & PAINT ALL INFILL BETWEEN BRICK REBUILD EXISTING CHIMNEY, SEE GENERAL ROOF NOTES SHEET A3.1 FOR FLASHING NEW WOOD SIDING TO MATCH OFFICE 203 ENCLOSED PORCH SOUTH EXTERIOR NEW WOOD SIDING TO MATCH OFFICE 203 ENCLOSED PORCH SOUTH EXTERIOR ADD HANDRAIL EXISTING HANDRAIL NOT FOR CONSTRUCTIONREVISIONS:S E R G E A N T A R C H I T E C T U R E P L L CPROJECT NUMBER: 230331 8 5 8 S O U T H A R C H S T R E E T , L I T T L E R O C K , A R . 7 2 2 0 6 T : 5 0 1 . 3 5 0 . 6 8 2 6700 SOUTH ROCK STREET, LITTLE ROCK, ARKANSASA3.4W E L C H - C H E R R Y H O U S ENORTH ELEVATIONDATE: FEBRUARY 26, 2025CERTIFICATE OF APPROPRIATENESS APPLICATION 3/8" 1'-0"1 NORTH ELEVATION April 3, 2025 ITEM NO.: 3 FILE NO.: HDC2025-006 14 Attachment C AARF 2007 PU2830