HomeMy WebLinkAboutHDC2011-0032 Proposed Free Standing Signage and Letter Requesting the Sign 11/21/2011C]
November 21, 2011
Department of Planning and Development _
Little Rock Historic District Commission
723 West Markham Street
Little Rock, AR 72201
RE — Rainwater Building Renovation- Proposed changes amended
Little Rock Historic District Commission:
The cover letter submitted November 14"' outlined the proposed changes to the exterior
of the building, after further review we ask that the commission accept the following as
clarification and an amendment on the proposed changes to the exterior of the building:
1. Windows
The outline dated November 14`h discussed the proposed changes to the windows and
the potential replacement of certain windows believed to be beyond repair. It is our
determination that these windows can be rebuilt to retain almost all of the existing
window parts and avoid replacing the window. Approximately five windows on the
south and east facades have deteriorated rails, stiles or sills. The deterioration is
mainly at the horizontal surfaces and joints where water collected, however they are
structurally sound. Only the deteriorated parts will be replaced with new matching
pieces and joined to the existing members.
2. Guardrails
To meet code requirements the earlier outline discussed providing a new wide
opening metal mesh added along the main body of the rails and guardrail added above
the existing top rail. The metal mesh will consist of small horizontal and vertical wire
mesh mounted in a thin metal frame with the new guardrail as part of the metal frame.
The mesh and frame with the added guardrail will be an independent panel and be
attached from the back side of the existing rail with mechanical fasteners and can be
removed in the future. The finish will match that of the existing railing.
If Code officials do NOT require modification then rails will be cleaned and painted
as required.
3. Downspouts
The existing gutters and downspouts are in a various state of deterioration with some
areas of water damage to the eaves and fascia. The Existing gutters are a 6" box style
commercial gutter with 4x3 residential downspouts. The gutters and downspout will
be replaced with half round style gutters (sized based on the roof area)"and 4" round
prefinished metal downspouts with a dark bronze metallic finish. The gutter location
with be installed at the same location on the roof fascia. The Downspout locations
will match the existing downspout locations.
4. Awning at South Entry
The awning will be an aluminum frame with a solid color exterior grade fabric
material. The shape will be a shed roof style awning with closed sides and 6" straight
valance, no scallops. The awning size will be 5' wide by 3' in depth and 2'-6" height.
5. Mechanical Condenser Units
The outline dated November 14`h proposed the exterior condenser units be located on
the roof of the addition on the rear of building. Understanding the sight concerns, we
propose to locate the condenser units at the ground level where the existing unit were
located and has an existing concrete pad. The existing pad is not large enough for all
twelve units so the pad will be added onto to fit all condenser units. The existing
shrubs used for screening will be relocated west closer to the parking lot to make
room for the additional condenser units and will continue to provide screening.
6. Satelite Dishes
No satellite dishes will be installed.
7. Signage
An existing wood sign is located to the east of the vehicular gate and is not an
historical feature. A new wood sign will be installed at the same location as the
existing and will measure approximately 3' by 2' and mounted on a treated 4" post
with a height not to exceed the existing sign. All wood will be painted.
8. Security bars
The ground level security bars will be removed.
9. Lighting
All exterior lighting on the front facade will remain. A new outdoor wall mounted
fixture will be installed at the south entry adjacent to the door. Made by Progress
Lighting, Arts and Crafts style, model P5633-46STR, weathered bronze finish, 6-5/8"
width by 10-1/2" height.
We look forward to discussing this exciting project with you in the near future.
Regards,
Daniel K. Fowler, AIA
Chief Operating Officer
CC: Chris Moses, Applicant
Awning Example
Metal Mesh Panel Examples
Proposed Free Standing Sip-nazie