STRUCTURAL INSPECTION REPORT
October 21, 2010
PURPOSE: Inspection of the structural condition of the specific areas mentioned below of the
property listed.
CLIENT s :
Clevette Weems
REPORT #:
10-1020
SITE LOCATION:
413 E 14` St
Little Rock, AR
LEGAL
Not given
DISCRIPTION:
TYPE OF HOME:
Two Story Frame Home
SPECIFIC
Various
PROBLEMS
INSPECTED FOR:
This is to certify that on October 21, 2010 a structural inspection of the specific areas addressed above
was made at the above address. The following shall be noted:
The home was inspected and the following were my findings:
1. The brick around the structure is in degraded condition and has undergone horizontal
and vertical movement. Vertical movement is the most common damage which can be
repaired however horizontal movement of the wall, in this case, requires replacement of
the brick.
2. The mortar between bricks has degraded to the point that you can see behind the brick.
Because it has decayed so much, rebricking the entire structure is required.
3. Termite damage was observed on the second floor structure toward the back of the
building. The walls were still covered so I could not inspect the wall structure but when
there is termite damage on the ceiling structure, the walls are typically infested beyond
simple repair. A large amount of structure to the second floor would require
replacement.
4. The structure on the Southwest has heavily damaged by what I am told was a tornado.
Major repair is required.
5. The front porch structure was completely demolished and requires repair.
6. Termite damage was observed in the base structure of the home.
7. Foundation piers have settled and require repair.
8. Holes in the roof have allowed severe mold to engross all plaster, carpet, decking and
many structure members. Selective replacement is required. An estimated amount is
difficult with plaster still on the walls.
9. Ceiling structure is rotten in many rooms. Floor structure is also rotten in several
rooms.
Page 1 of 9
HALL
ENGINEERING
Ltd.
A substantial amount of structure must be replaced. All plaster and sheetrock must be replaced.
All flooring must be replaced. The bathroom components are damaged. The plumbing and
electrical appear heavily decayed and/or damaged. All brick must be replaced.
See Appendix A for supporting pictures.
The above report is based on investigation and analysis and our conclusions are based on a
reasonable degree of engineering certainty which also draws on our comprehensive experience.
Unfortunately, no one can guarantee the performance of a foundation or structure which has been
compromised.
By accepting and using these inspection results, you consent to the inspection agreement
located at wti>ti+ 1aa11-en�'.colnlagrLer7?L77t.pdf. If you do not have internet access or do not
understand or agree with the inspection agreement, contact Hall Engineering prior to using the
inspection results to your benefit.
Please call Justin directly at 501-588-3355 or Justin & hall-eng.com
questions specific to this report.
►�►0111111 (f Q 214Vi"
GIS TE N/f���
STATE OF
• ARKANSAS
NO_ i 1050
7 . SIQNA
Justin W. Hall, PE #11050
Limitations:
This report is not a guarantee of the future of your home or building. Potential shifting of soils and the nature of construction
underground are impossible to know during this or any other inspection. We use our expertise and engineering backgrounds
to give you our best opinion of the future of your foundation. Please read the inspection agreement on-line at www.hall-
en r.comlaereement. d . By reviewing and making use of the inspection results on the report, you legally consent to the
inspection agreement and its terms. This structural inspection report for the subject building(s) is prepared for the sole and
exclusive use by the owner(s) or inspection purchasing agent. This structural inspection report may not be sold, transferred
or assigned to any other party without first contacting Hall Engineering, Ltd. Liability under this structural inspection report
is limited solely to the owner(s).