HomeMy WebLinkAboutZ-10165 Ground Floor PlanSB5221B44 4'X11' ISLANDSB36B24RDWB24RB24RSB36
B42B42B31
LCB4824LLCB2448R
B57B57B57B572DB45182DB45182DB4518B44B44
SB33
B40LCB4036RB31 GRILLSMOKER
BUILT-INSBUILT-INSSB5221B44 4'X11' ISLANDSB36B24RDWB24RB24RSB36
B42B42B31
LCB4824LLCB2448R
B57B57B57B572DB45182DB45182DB4518B44B44
SB33
B40LCB4036RB31 GRILLSMOKER
BUILT-INSBUILT-INSU482490
REF
U571596U571596W4242W4242W5742W5342W2478W6478W5342W5342W5342W4442 W4442 W44425480 2870SC 6080 6080 2870SC
3070SC3070SC3050SC3040SC90809080
1070FX
2640SC 2640SC
30804080
3080
2468308030802680288015080
CASED OPENING
8898
ARCH FIREPLACE2870FX2870FX2870FX1070FX
8090 3070SC3070FX3070SC3040SC3040SCFIREPLACE3080UP cLcLcLE1
10
E1
10Exterior Elevation Front
E2
11
E2
11
Exterior Elevation LeftE3
10
E3
10
Exterior Elevation Back
E4
11
E4
11
Exterior Elevation RightBS1
12
BS1
12
BS1
12
BS1
12BUILDING SECTION 1BS2
12
BS2
12
BS2
12
BS2
12
BUILDING SECTION 2E5
14
E5
14DETAILS
4'-5 3/4"4'-2 1/4"4'-2"3'3'4'-2"7'-8"4'-5 3/4"4'-5 3/4"11'-4 1/2"7'-7 1/2"7'-4"4'-4"9'-10 1/2"18'-3 1/2"4'-10"4'-2"
6'-2"11'-8"5'-10 1/2"7'-8 3/4"7'-8 3/4"2'-4"
23'-8 1/2"15'-5 1/2"
39'-2"
2'-6"10'19'11'-8"33'80'-4"7'2'-8"2'-4"2'-8"2'-8"2'-4"5'-8"3'-6"10'11'-10"4'-8"8'-11 1/2"5'-8 1/2"8'-8"14'-4"22'73'-4"15'-2"
39'-2"
5'6'-8"5'5'-5"
24'
2'-4"
24'
41'-6"6'-8"7'-8"12'-4"92'-8"1'-4"1'-4"1'-4"4'-3 1/2"1'-4"2'-8 1/2"1'-4"
15'-2"
4'-8"4'-8"5'13'6'5'
5'-4"9'-10"5'28'7'-4"
7'-4"4'-4"7'20'-6"7'-4"6'-4"23'-4"3'95'-4"1'-11"
11'-4"
3'-6"4'-8 1/2"
21'-2" X 21'-8"
19'-11" X 23'-0"
23'-4" X 27'-8"
17'-2" X 24'-11"
12'-8" X 5'-0"
5'-4" X 4'-8"
7'-0" X 18'-4"
7'-0" X 11'-4"
11'-0" X 5'-8"
19'-10" X 13'-8"
14'-1" X 4'-7"
14'-1" X 9'-3"
11'-4" X 24'-0"
1910 SQ FT
GARAGE
MUD
PANTRY
DINING
PORCH
ELEV.
LIVINGKITCHEN
FOYER
OUTDOOR LIVING
WET BAR
12" TREADS
LIVING AREA
OUTDOOR LIVING
GARAGE
PROJECT TITLECONTENTSFLOOR PLAN BASEMENT LEVELDATESHEETA 2.0GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION
IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER.
ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD,
WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND.
ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET
AREAS TO HAVE WATER RESISTANT GYPSUM BOARD.
BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7
SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM
NET CLEAR OPERABLE HEIGHT OF 24" AND HAVE A MAXIMUM FINISH
SILL HEIGHT OF 44" FROM FINISH FLOOR.
ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR
LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR
SHOWERS TO BE TEMPERED.
BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO
THE OUTSIDE AS REQUIRED BY CODE.
ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED.
ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD
AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES.
GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH
SELECTED MANUFACTURER(S).
GENERAL HVAC SYSTEM NOTES:
1.
2.
3.
4.
MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM
DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC
SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS
AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT
SUPPLIER FOR FINAL REVIEW AND APPROVAL
PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD,
AND THE DRYER VENT.
LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR.
GENERAL PLUMBING NOTES:
1.
2.
3.
4.
5.
PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR
ADHERING TO ALL APPLICABLE CODES AND SAFETY
REQUIREMENTS.
PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC
EQUIPMENT AS REQUIRED.
IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION
OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO
TIE FRAMING BACK TOGETHER.
ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT.
ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED
BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY
DESIGNER PRIOR TO START OF CONSTRUCTION.
1 LEVEL 1
1/4" = 1'-0"COUNTRY CLUB6/4/25