Loading...
HomeMy WebLinkAboutZ-10165 Ground Floor PlanSB5221B44 4'X11' ISLANDSB36B24RDWB24RB24RSB36 B42B42B31 LCB4824LLCB2448R B57B57B57B572DB45182DB45182DB4518B44B44 SB33 B40LCB4036RB31 GRILLSMOKER BUILT-INSBUILT-INSSB5221B44 4'X11' ISLANDSB36B24RDWB24RB24RSB36 B42B42B31 LCB4824LLCB2448R B57B57B57B572DB45182DB45182DB4518B44B44 SB33 B40LCB4036RB31 GRILLSMOKER BUILT-INSBUILT-INSU482490 REF U571596U571596W4242W4242W5742W5342W2478W6478W5342W5342W5342W4442 W4442 W44425480 2870SC 6080 6080 2870SC 3070SC3070SC3050SC3040SC90809080 1070FX 2640SC 2640SC 30804080 3080 2468308030802680288015080 CASED OPENING 8898 ARCH FIREPLACE2870FX2870FX2870FX1070FX 8090 3070SC3070FX3070SC3040SC3040SCFIREPLACE3080UP cLcLcLE1 10 E1 10Exterior Elevation Front E2 11 E2 11 Exterior Elevation LeftE3 10 E3 10 Exterior Elevation Back E4 11 E4 11 Exterior Elevation RightBS1 12 BS1 12 BS1 12 BS1 12BUILDING SECTION 1BS2 12 BS2 12 BS2 12 BS2 12 BUILDING SECTION 2E5 14 E5 14DETAILS 4'-5 3/4"4'-2 1/4"4'-2"3'3'4'-2"7'-8"4'-5 3/4"4'-5 3/4"11'-4 1/2"7'-7 1/2"7'-4"4'-4"9'-10 1/2"18'-3 1/2"4'-10"4'-2" 6'-2"11'-8"5'-10 1/2"7'-8 3/4"7'-8 3/4"2'-4" 23'-8 1/2"15'-5 1/2" 39'-2" 2'-6"10'19'11'-8"33'80'-4"7'2'-8"2'-4"2'-8"2'-8"2'-4"5'-8"3'-6"10'11'-10"4'-8"8'-11 1/2"5'-8 1/2"8'-8"14'-4"22'73'-4"15'-2" 39'-2" 5'6'-8"5'5'-5" 24' 2'-4" 24' 41'-6"6'-8"7'-8"12'-4"92'-8"1'-4"1'-4"1'-4"4'-3 1/2"1'-4"2'-8 1/2"1'-4" 15'-2" 4'-8"4'-8"5'13'6'5' 5'-4"9'-10"5'28'7'-4" 7'-4"4'-4"7'20'-6"7'-4"6'-4"23'-4"3'95'-4"1'-11" 11'-4" 3'-6"4'-8 1/2" 21'-2" X 21'-8" 19'-11" X 23'-0" 23'-4" X 27'-8" 17'-2" X 24'-11" 12'-8" X 5'-0" 5'-4" X 4'-8" 7'-0" X 18'-4" 7'-0" X 11'-4" 11'-0" X 5'-8" 19'-10" X 13'-8" 14'-1" X 4'-7" 14'-1" X 9'-3" 11'-4" X 24'-0" 1910 SQ FT GARAGE MUD PANTRY DINING PORCH ELEV. LIVINGKITCHEN FOYER OUTDOOR LIVING WET BAR 12" TREADS LIVING AREA OUTDOOR LIVING GARAGE PROJECT TITLECONTENTSFLOOR PLAN BASEMENT LEVELDATESHEETA 2.0GENERAL FLOOR PLAN NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER. ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD, WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND. ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET AREAS TO HAVE WATER RESISTANT GYPSUM BOARD. BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM NET CLEAR OPERABLE HEIGHT OF 24" AND HAVE A MAXIMUM FINISH SILL HEIGHT OF 44" FROM FINISH FLOOR. ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR SHOWERS TO BE TEMPERED. BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO THE OUTSIDE AS REQUIRED BY CODE. ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED. ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES. GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH SELECTED MANUFACTURER(S). GENERAL HVAC SYSTEM NOTES: 1. 2. 3. 4. MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT SUPPLIER FOR FINAL REVIEW AND APPROVAL PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD, AND THE DRYER VENT. LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR. GENERAL PLUMBING NOTES: 1. 2. 3. 4. 5. PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC EQUIPMENT AS REQUIRED. IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO TIE FRAMING BACK TOGETHER. ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT. ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY DESIGNER PRIOR TO START OF CONSTRUCTION. 1 LEVEL 1 1/4" = 1'-0"COUNTRY CLUB6/4/25