Loading...
HomeMy WebLinkAboutZ-10165 ElevationsARCHITECTURAL ASPHALT SHINGLES SYNTHETIC ROOFING UNDERLAYMENT 1/2" ZIP BOARD TAPED AT JOINTS RAFTER PER CODE MASONRY FIREPLACE CRICKET R-38 INSULATION 7" KNEE WALL CEILING JOIST PER CODE SUB-FASCIA FASCIA SOFFIT 2"X4" SILL PLATE 2"X4" STUD BRICK VENEER 3 1/2" R-15 BATT INSULATION 1/2" ZIP BOARD TAPED AT JOINTS 2"X4" SILL PLATE ENG. FLOOR TRUSS HEADER BRICK VENEER ALUMINUM-CLAD WOOD WINDOW 2"X4" SILL PLATE "L" BOLT CMU BLOCK FOUNDATION SLOPE FOR DRAINAGE CONCRETE FOOTING 24"W X 16"D VERIFY W/STRUCTURAL & SOILS ENGINEERS CONT. REBAR AS REQ. 4' CONC. SLAB 15 MIL STEGO WRAP VAPOR BARRIER CRUSHED STONE FILL COMPACTED SOIL CROWN MOLDING INT. RECESSED LIGHT 5/8" GYP. BOARD 1/2" GYP. BOARD WINDOW TRIM BASEBOARD FINISH FLOORING TYPICAL WALL SECTION SCALE 3/8"=1' ARCHITECTURAL ASPHALT SHINGLES SYNTHETIC ROOFING UNDERLAYMENT 1/2" ZIP BOARD TAPED AT JOINTS RAFTER PER CODE MASONRY FIREPLACE CRICKET R-38 INSULATION 7" KNEE WALL CEILING JOIST PER CODE SUB-FASCIA FASCIA SOFFIT 2"X4" SILL PLATE 2"X4" STUD BRICK VENEER 3 1/2" R-15 BATT INSULATION 1/2" ZIP BOARD TAPED AT JOINTS 2"X4" SILL PLATE ENG. FLOOR TRUSS HEADER BRICK VENEER ALUMINUM-CLAD WOOD WINDOW 2"X4" SILL PLATE "L" BOLT CMU BLOCK FOUNDATION SLOPE FOR DRAINAGE CONCRETE FOOTING 24"W X 16"D VERIFY W/STRUCTURAL & SOILS ENGINEERS CONT. REBAR AS REQ. 4' CONC. SLAB 15 MIL STEGO WRAP VAPOR BARRIER CRUSHED STONE FILL COMPACTED SOIL CROWN MOLDING INT. RECESSED LIGHT 5/8" GYP. BOARD 1/2" GYP. BOARD WINDOW TRIM BASEBOARD FINISH FLOORING TYPICAL WALL SECTION SCALE 3/8"=1'PROJECT TITLECONTENTSDETAILSDATESHEETA 7.1GENERAL FRAMING NOTES: 1. 2. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT FEDERAL, STATE & LOCAL CODES, ORDINANCES AND REGULATIONS, ETC. THESE ARE TO BE CONSIDERED AS PART OF THE SPECIFICATIONS OF THE BUILDING AND SHOULD BE ADHERED TO EVEN IF THEY ARE IN VARIANCE WITH THE PLAN. THE STRUCTURAL DATA SHOWN ON THE PLAN IS FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO HAVE A LICENSED STRUCTURAL ENGINEER REVIEW ALL STRUCTURAL ELEMENTS SUCH AS JOIST SIZE & SPACING, BEAM AND HEADER SIZES, BEAM CONNECTIONS, ETC. *VERIFY FINAL SIZES WITH JOIST & BEAM MANUFACTURER. GENERAL FRAMING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ALL WOOD FRAMING IN CONTACT WITH CONCRETE OR MASONRY TO BE PRESSURE TREATED. ALL STUD WALLS TO BE FRAMED 16" O.C. ALL ANGLED WALLS TO BE FRAMED AT 45 DEGREE ANGLE UNLESS OTHERWISE NOTED. MINIMUM HEADER SIZE AT SECOND AND THIRD FLOORS TO BE (2) 2x6'S UNLESS OTHERWISE NOTED. PROVIDE FULL SOLID BEARING OR STUD BEARING UNDER ALL BEAM BEARING POINTS. ALL BEAMS TO HAVE TRIPLE STUD BEARING AT EACH END. ALL STRUCTURAL STEEL TO CONFORM WITH ASTM SPECIFICATIONS A-36. STAIR CONSTRUCTION TO CONSIST OF (3) 2x12 STRINGERS, 5/4" OR 2x THICK TREADS & 3/4" THICK RISERS OR MATERIALS FABRICATED BY A COMPONENT MANUFACTURER. HANDRAILS TO BE MOUNTED 32"-34" ABOVE STAIR NOSING. GUARDRAILS TO BE MOUNTED AT 36" HEIGHT. FLOOR FRAMING LAYOUT TO BE COORDINATED WITH THE GENERAL AND HVAC CONTRACTORS TO PROVIDE ACCESS CHASES AND UNOBSTRUCTED RUNS FOR HVAC DUCT WORK.COUNTRY CLUB6/4/25