HomeMy WebLinkAboutPrefinal Construction Set4920 COUNTRY CLUB BLVD
LITTLE ROCK, ARKANSAS
6/4/2025 6/4/25COUNTRY CLUB
GENERAL SITE NOTES:
1.
2.
3.
4.
GENERAL CONTRACTOR TO VERIFY THE EXISTING TOPOGRAPHIC
GRADE LEVELS, LOCATIONS OF TREES, AND THE PROPOSED
BUILDING LOCATIONS. CONTRACTOR TO NOTIFY DESIGNER OF
SITE CONDITIONS PRIOR TO START OF CONSTRUCTION.
GENERAL CONTRACTOR TO HAVE A LICENSED ENGINEER OR
LICENSED SURVEYOR STAKE OUT OR VERIFY THE BUILDING
LOCATION TO ENSURE THAT THE BUILDING DOES NOT ENCROACH
ON ANY SETBACKS OR EASEMENTS, UNLESS THE
ENCROACHMENT IS ALLOWED BY ZONING AND BUILDING CODES.
CONTRACTOR TO NOTIFY DESIGNER IF ANY ENCROACHMENT
ISSUES PRIOR TO START OF CONSTRUCTION.
GENERAL CONTRACTOR TO LOCATE ALL UTILITY SERVICES, I.E.
WATER, SEWER, GAS, ELECTRICAL, TELEPHONE, CABLE TV, AND
COORDINATE THE EXTENSIONS TO THE BUILDING WITH THE
APPROPRIATE INSTALLER.
GENERAL CONTRACTOR TO COORDINATE FINISH TOPOGRAPHIC
GRADING AND PAVING OF WALKS, DRIVEWAYS, PATIOS, ETC. AS
REQUIRED FOR POSITIVE DRAINAGE AWAY FROM THE BUILDING.
GENERAL CONSTRUCTION NOTES:
1.
2.
3.
4.
5.
6.
7.
GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS.
GENERAL CONTRACTOR TO COORDINATE SITE GRADING &
DRAINAGE WITH OWNER & GEOTECH ENGINEER OR CIVIL ENGINEER.
GENERAL CONTRACTOR TO VERIFY ALL CABINETRY WITH OWNER
PRIOR TO INSTALLATION.
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK
AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT FEDERAL,
STATE AND LOCAL CODES, ORDINANCES AND REGULATIONS, ETC.
THESE ARE TO BE CONSIDERED AS PART OF THE SPECIFICATIONS OF
THIS BUILDING AND SHOULD BE ADHERED TO EVEN IF THEY ARE IN
VARIANCE WITH THE PLAN.
THE STRUCTURAL DATA SHOWN ON THE PLANS ARE FOR
REFERENCE ONLY. GENERAL CONTRACTOR IS TO HAVE A LICENSED
STRUCTURAL ENGINEER REVIEW ALL STRUCTURAL ELEMENTS SUCH
AS JOIST SIZE AND SPACING, BEAM & HEADER SIZES, BEAM
CONNECTIONS, ETC.
CONTRACTOR TO ENSURE THAT PRE-FAB FIREPLACE
CONSTRUCTION MEETS OR EXCEEDS ALL APPLICABLE CODES. FLUE
HEIGHT TO MEET NECESSARY HEIGHT TO COMPLY WITH LOCAL
CODES.
CONTRACTOR TO COORDINATE GAS SERVICE REQUIREMENTS WITH
THE CITY.
N
5'-0 1/2"
5'-0 1/2"95'-9"39'-11"
FIPFIP
FIP
FIP
50.0' M&P
50.0' M&P138.77' M, 140.0 P138.0' M, 140.0 PPROPOSED NEW
TWO STORY
RESIDENCE 4834 SF
COUNTRY CLUB BLVD
(80' ROW)
5 4 9
5 4 8
547
546
5 4 6
5465455445435 4 2
5 4 1
540
539
NEW DRIVEWAY
EXISTING
RESIDENCE
EXISTING
GARAGE
NEW POOLNEW 4' HIGH
RETAINING WALL
LOT 7
NEW PATIO
PROJECT TITLEA 1.0COUNTRY CLUBCONTENTSSITE PLAN DATESHEET1 SITE PLAN
1/8" = 1'-0"6/4/25
SB5221B44 4'X11' ISLANDSB36B24RDWB24RB24RSB36
B42B42B31
LCB4824LLCB2448R
B57B57B57B572DB45182DB45182DB4518B44B44
SB33
B40LCB4036RB31 GRILLSMOKER
BUILT-INSBUILT-INSSB5221B44 4'X11' ISLANDSB36B24RDWB24RB24RSB36
B42B42B31
LCB4824LLCB2448R
B57B57B57B572DB45182DB45182DB4518B44B44
SB33
B40LCB4036RB31 GRILLSMOKER
BUILT-INSBUILT-INSU482490
REF
U571596U571596W4242W4242W5742W5342W2478W6478W5342W5342W5342W4442 W4442 W44425480 2870SC 6080 6080 2870SC
3070SC3070SC3050SC3040SC90809080
1070FX
2640SC 2640SC
30804080
3080
2468308030802680288015080
CASED OPENING
8898
ARCH FIREPLACE2870FX2870FX2870FX1070FX
8090 3070SC3070FX3070SC3040SC3040SCFIREPLACE3080UP cLcLcLE1
10
E1
10Exterior Elevation Front
E2
11
E2
11
Exterior Elevation LeftE3
10
E3
10
Exterior Elevation Back
E4
11
E4
11
Exterior Elevation RightBS1
12
BS1
12
BS1
12
BS1
12BUILDING SECTION 1BS2
12
BS2
12
BS2
12
BS2
12
BUILDING SECTION 2E5
14
E5
14DETAILS
4'-5 3/4"4'-2 1/4"4'-2"3'3'4'-2"7'-8"4'-5 3/4"4'-5 3/4"11'-4 1/2"7'-7 1/2"7'-4"4'-4"9'-10 1/2"18'-3 1/2"4'-10"4'-2"
6'-2"11'-8"5'-10 1/2"7'-8 3/4"7'-8 3/4"2'-4"
23'-8 1/2"15'-5 1/2"
39'-2"
2'-6"10'19'11'-8"33'80'-4"7'2'-8"2'-4"2'-8"2'-8"2'-4"5'-8"3'-6"10'11'-10"4'-8"8'-11 1/2"5'-8 1/2"8'-8"14'-4"22'73'-4"15'-2"
39'-2"
5'6'-8"5'5'-5"
24'
2'-4"
24'
41'-6"6'-8"7'-8"12'-4"92'-8"1'-4"1'-4"1'-4"4'-3 1/2"1'-4"2'-8 1/2"1'-4"
15'-2"
4'-8"4'-8"5'13'6'5'
5'-4"9'-10"5'28'7'-4"
7'-4"4'-4"7'20'-6"7'-4"6'-4"23'-4"3'95'-4"1'-11"
11'-4"
3'-6"4'-8 1/2"
21'-2" X 21'-8"
19'-11" X 23'-0"
23'-4" X 27'-8"
17'-2" X 24'-11"
12'-8" X 5'-0"
5'-4" X 4'-8"
7'-0" X 18'-4"
7'-0" X 11'-4"
11'-0" X 5'-8"
19'-10" X 13'-8"
14'-1" X 4'-7"
14'-1" X 9'-3"
11'-4" X 24'-0"
1910 SQ FT
GARAGE
MUD
PANTRY
DINING
PORCH
ELEV.
LIVINGKITCHEN
FOYER
OUTDOOR LIVING
WET BAR
12" TREADS
LIVING AREA
OUTDOOR LIVING
GARAGE
PROJECT TITLECONTENTSFLOOR PLAN BASEMENT LEVELDATESHEETA 2.0GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION
IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER.
ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD,
WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND.
ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET
AREAS TO HAVE WATER RESISTANT GYPSUM BOARD.
BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7
SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM
NET CLEAR OPERABLE HEIGHT OF 24" AND HAVE A MAXIMUM FINISH
SILL HEIGHT OF 44" FROM FINISH FLOOR.
ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR
LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR
SHOWERS TO BE TEMPERED.
BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO
THE OUTSIDE AS REQUIRED BY CODE.
ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED.
ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD
AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES.
GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH
SELECTED MANUFACTURER(S).
GENERAL HVAC SYSTEM NOTES:
1.
2.
3.
4.
MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM
DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC
SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS
AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT
SUPPLIER FOR FINAL REVIEW AND APPROVAL
PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD,
AND THE DRYER VENT.
LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR.
GENERAL PLUMBING NOTES:
1.
2.
3.
4.
5.
PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR
ADHERING TO ALL APPLICABLE CODES AND SAFETY
REQUIREMENTS.
PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC
EQUIPMENT AS REQUIRED.
IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION
OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO
TIE FRAMING BACK TOGETHER.
ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT.
ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED
BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY
DESIGNER PRIOR TO START OF CONSTRUCTION.
1 LEVEL 1
1/4" = 1'-0"COUNTRY CLUB6/4/25
DN
3DB2521
SB3421SB2721R
SB30213DB2521 SB32213DB1821DESK 3DB25303DB25301DB2721103DB18213DB18213DB1821SB32213DB18213DB1821B30B62B30B30
SB32213DB1921 3DB1921
3DB1721 3DB1721
3DB2521
SB3421SB2721R
SB30213DB2521 SB32213DB1821DESK 3DB25303DB25301DB2721103DB18213DB18213DB1821SB32213DB18213DB1821B30B62B30B30
SB32213DB1921 3DB1921
3DB1721 3DB1721LINEN
U361590U361590U361590
U462790U462790U362490
W3042W3142W3042W3042W3142
2460SC2460FX2460SC368030803080 3060SC3060SC3016FX3060SC3050FX3016FX3080 6080 3080
3016FX 3016FX
3060SC3060SC2440FX3060SC3040SC3040SC5050FX3016FX30802880
30802460SC2460FX2460SC
2050FX2050FX2050FX 24802480 3080248024802880
3080
28802480
2880
2680268026802480 14080
2068206820682068UP 3'2'-10"2'-6"11'2'-6"4'-2"4'8'2'-8"4'-10"5'-10"6'-2"1'-10"4'-2"5'-2"1'-8"2'-4"2'-4"1'-8"3'-10"2'-4"2'-4"5'-10"1'-6"2'2'1'-6"
14'-4"7'2'-4 1/2"3'-8 3/4"8'3'-8 3/4"
39'-2"5'-1 3/4"5'-1 3/4"6'-8"10'-3 1/2"4'-10 1/2"8'4'8'7'-6"12'6'13'2'80'-4"4'-8"2'-8"1'-8"2'-4"2'-2"7'-5 3/4"7'-2 1/4"4'-6"10'-10"1'-8"13'3'-6"4'-6"14'-8"15'-4"3'-6"5'-10"16'6'-8"4'-8"97'2'7'-8 3/4"10'-2 3/4"
2'-6"17'-11 1/2"3'-6 1/2"3'-6"11'-8"
39'-2"
24'15'-2"
10'3'-4"5'-8"5'5'10'-2"
12'1'6'
7'
20'-2"
11'-8"7'-4"5'15'-2"
7'12'
5'5'-8"9'-6"
5'-6"
7'6'4'5'5'5'-6"8'13'12'-4"94'-8"97'2'-4"7'-8"3'4'-10"7'-2 1/2"2'-4 1/2"2'-1"
14'-10" X 15'-0"
2924 SQ FT
11'-5" X 16'-7"
14'-10" X 12'-8"
5'-10" X 7'-7"
14'-10" X 14'-4"
23'-4" X 12'-8"
4'-8" X 7'-7"
9'-8" X 5'-8"5'-0" X 5'-8"
11'-8" X 11'-8"
5'-4" X 4'-8"
6'-4" X 4'-8"
18'-4" X 7'-2"
19'-10" X 15'-4"
5'-1" X 9'-0"5'-4" X 9'-0"
11'-3" X 7'-8"
11'-4" X 9'-7"
6'-8" X 3'-8"
3'-2" X 6'-
4"
24'-1" X 12'-0"
19'-10" X 6'-4"
6'-8" X 4'-8"
7'-0" X 7'-6"
OPEN BELOW
BEDROOM 3
PLAYROOM
BEDROOM 4
LAUNDRY
1/2 BATH
ELEV.
BALCONY
BATH 4
CLOSET
BEDROOM 2HIS
MASTER BATH
HIS TLT
HER
TLT
HERS
CLOSET BATH 2
MASTER BDRM
SITTING
TUB
SHOWER
CLOSET
BATH 3
12" TREADS
LIVING AREA PROJECT TITLECONTENTSFLOOR PLAN LEVEL 2DATESHEETA 2.0MAIN LEVEL H/C
SECOND LEVEL H/C
TOTAL H/C
MAIN LEVEL PORCHES
1910 SF
2924 SF
4834 SF
769 SF
284 SF
1053 SF
1369 SF
7256 SF
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION
IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER.
ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD,
WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND.
ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET
AREAS TO HAVE WATER RESISTANT GYPSUM BOARD.
BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7
SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM
NET CLEAR OPERABLE HEIGHT OF 24" AND HAVE A MAXIMUM FINISH
SILL HEIGHT OF 44" FROM FINISH FLOOR.
ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR
LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR
SHOWERS TO BE TEMPERED.
BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO
THE OUTSIDE AS REQUIRED BY CODE.
ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED.
ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD
AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES.
GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH
SELECTED MANUFACTURER(S).
GENERAL HVAC SYSTEM NOTES:
1.
2.
3.
4.
MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM
DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC
SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS
AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT
SUPPLIER FOR FINAL REVIEW AND APPROVAL
PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD,
AND THE DRYER VENT.
LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR.
GENERAL PLUMBING NOTES:
1.
2.
3.
4.
5.
PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR
ADHERING TO ALL APPLICABLE CODES AND SAFETY
REQUIREMENTS.
PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC
EQUIPMENT AS REQUIRED.
IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION
OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO
TIE FRAMING BACK TOGETHER.
ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT.
ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED
BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY
DESIGNER PRIOR TO START OF CONSTRUCTION.
1 LEVEL 2
1/4" = 1'-0"
SECOND LEVEL PORCHES
TOTAL PORCHES
2-CAR GARAGE
TOTAL UNDER ROOF COUNTRY CLUB6/4/25
DN3068
3050FX2026FX
15'-5 1/2"14'-11 1/2"7'-5 3/4"7'-5 3/4"14'-11 1/2"15'-5 1/2"6'-6"17'-11"3'-4"17'-11"
37 SQ FT
14'-10" X 14'-4"
OPEN BELOW
ATTIC
ACCESS
LIVING AREA PROJECT TITLECONTENTSFLOOR PLAN LEVEL 3DATESHEETA 2.0GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION
IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER.
ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD,
WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND.
ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET
AREAS TO HAVE WATER RESISTANT GYPSUM BOARD.
BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7
SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 24", A MINIMUM
NET CLEAR OPERABLE HEIGHT OF 22" AND HAVE A MAXIMUM FINISH
SILL HEIGHT OF 44" FROM FINISH FLOOR.
ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR
LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR
SHOWERS TO BE TEMPERED.
BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO
THE OUTSIDE AS REQUIRED BY CODE.
ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED.
ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD
AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES.
GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH
SELECTED MANUFACTURER(S).
GENERAL HVAC SYSTEM NOTES:
1.
2.
3.
4.
MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM
DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC
SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS
AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT
SUPPLIER FOR FINAL REVIEW AND APPROVAL
PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD,
AND THE DRYER VENT.
LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR.
GENERAL PLUMBING NOTES:
1.
2.
3.
4.
5.
PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR
ADHERING TO ALL APPLICABLE CODES AND SAFETY
REQUIREMENTS.
PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC
EQUIPMENT AS REQUIRED.
IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION
OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO
TIE FRAMING BACK TOGETHER.
ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT.
ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED
BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY
DESIGNER PRIOR TO START OF CONSTRUCTION.
1 LEVEL 3 W/OVERLAY
1/4" = 1'-0"COUNTRY CLUB6/4/25
R6
R6
R6
R6
R6
R6R6
R6
R6R6
R6 R6
R6 R6R6
R6
R6
R6R6
R6 R6
R6
R6R6
R6R6
R6
R6R6
R6R6
R6R6
R6
R6R6 R6
R6R6R6
R6R6R6
R6 R6
R6R6 R6
R6 R6
R6R6
10'-0"
CEILING FAN
STAINED T&G CEILING
RECESSED LIGHT
GYP. BOARD TYP.
INT. RECESSED LIGHT
GYP. BOARD TYP.
LINEAR SHOP LIGHT
CHANDELIER
INT. RECESSED LIGHT
GYP. BOARD TYP.
CEILING FAN
VANITY LIGHT
10'-0"
10'-0"
10'-0"10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
INT. RECESSED LIGHT
GYP. BOARD TYP.
PENDANT LIGHT
RECESSED LIGHT
STAINED T&G CEILING
WALL SCONCE
ELECTRICAL SCHEDULE
DESCRIPTION
2D
SY
MB
OL
ELEGANT PENDANT
WROUGHT IRON CANDELABRA
SHOP LIGHT (LONG) [72W]
LOWE WALL SCONCE
TRADITIONAL FLUSH DOME
WALL SCONCE 3
CLASSIC CEILING FAN
EXHAUST FAN
RECESSED DOWN LIGHT 6 R6R6
PROJECT TITLECONTENTSREFLECTED CEILINGPLAN-LEVEL 1DATESHEETA 3.0GENERAL ELECTRICAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT
ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE
PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN
INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER
IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE
THE INSTALLATION OF FIXTURES, SWITCHES, ETC.
GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL
APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER,
DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC
EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR
MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES.
ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I.
TYPE PER CODE.
SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND
COLOR MATCHED WITH THE INTERIOR TRIM.
CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS,
COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL
COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT.
CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS.
VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES
ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH
EACH OTHER IF THERE ARE MULTIPLE SWITCHES.
CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND
EXTERIOR LIGHTING CIRCUITS AND SWITCHES.
PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP,
ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS.
G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER.
1 LEVEL 1 RCP
1/4" = 1'-0"
REFLECTED CEILING LEGEND
COUNTRY CLUB6/4/25
R6R6
R6 R6
R6 R6R6
R6 R6R6
R6 R6 R6R6
R6
R6R6
R6 R6
R6
R6
R6R6
R6
R6
R6 R6
R6
R6
R6
R6R6R6
R6
R6 R6
R6
R6
R6R6 R6
R6
R6
R6 R6
R6 R6
R6R6R6
R6
R6
R6
R6
R6
R6
R6 R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"9'-0"
9'-0"
9'-0"SURFACE MOUNTED LIGHT
EXHAUST FAN
VANITY LIGHT
GYP. BOARD TYP.
INT. RECESSED LIGHT
INT. RECESSED LIGHT
CEILING FAN
SURFACE MOUNTED LIGHT
GYP. BOARD TYP.
CEILING FAN
STAINED T&G CEILING
CEILING FAN
RECESSED LIGHT
GYP. BOARD TYP.
INT. RECESSED LIGHT
CEILING FAN
VANITY LIGHT
SURFACE MOUNTED LIGHT
EXHAUST FAN
VANITY LIGHT
EXHAUST FAN
SURFACE MOUNTED LIGHT
INT. RECESSED LIGHT
CEILING FAN
ELECTRICAL SCHEDULE
DESCRIPTION
2D
SY
MB
OL
ELEGANT PENDANT
WROUGHT IRON CANDELABRA
SHOP LIGHT (LONG) [72W]
LOWE WALL SCONCE
TRADITIONAL FLUSH DOME
WALL SCONCE 3
CLASSIC CEILING FAN
EXHAUST FAN
RECESSED DOWN LIGHT 6 R6R6
PROJECT TITLECONTENTSREFLECTED CEILINGPLAN-LEVEL 2DATESHEETA 3.1REFLECTED CEILING LEGEND
1 LEVEL 2 RCP
3/16" = 1'-0"
GENERAL ELECTRICAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT
ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE
PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN
INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER
IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE
THE INSTALLATION OF FIXTURES, SWITCHES, ETC.
GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL
APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER,
DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC
EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR
MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES.
ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I.
TYPE PER CODE.
SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND
COLOR MATCHED WITH THE INTERIOR TRIM.
CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS,
COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL
COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT.
CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS.
VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES
ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH
EACH OTHER IF THERE ARE MULTIPLE SWITCHES.
CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND
EXTERIOR LIGHTING CIRCUITS AND SWITCHES.
PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP,
ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS.
G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER.COUNTRY CLUB6/4/25
R6
R6R6
R6
ATTIC
ACCESS
GYP. BOARD TYP.
INT. RECESSED LIGHT
ELECTRICAL SCHEDULE
DESCRIPTION
2D
SY
MB
OL
ELEGANT PENDANT
WROUGHT IRON CANDELABRA
SHOP LIGHT (LONG) [72W]
LOWE WALL SCONCE
TRADITIONAL FLUSH DOME
WALL SCONCE 3
CLASSIC CEILING FAN
EXHAUST FAN
RECESSED DOWN LIGHT 6 R6R6
PROJECT TITLECONTENTSREFLECTED CEILINGPLAN-LEVEL 3DATESHEETA 3.2REFLECTED CEILING LEGEND
GENERAL ELECTRICAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT
ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE
PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN
INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER
IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE
THE INSTALLATION OF FIXTURES, SWITCHES, ETC.
GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL
APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER,
DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC
EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR
MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES.
ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I.
TYPE PER CODE.
SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND
COLOR MATCHED WITH THE INTERIOR TRIM.
CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS,
COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL
COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT.
CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS.
VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES
ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH
EACH OTHER IF THERE ARE MULTIPLE SWITCHES.
CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND
EXTERIOR LIGHTING CIRCUITS AND SWITCHES.
PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP,
ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS.
G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER.
1 LEVEL 3 RCP
3/16" = 1'-0"COUNTRY CLUB6/4/25
12 : 12
12 : 12
12 : 128 : 128 : 12 8 : 128 : 12
12 : 1212 : 12
12 : 12
8 : 1212 : 1212 : 12 12 : 12
12 : 12
12 : 12
8 : 12
2 : 12
RIDGE CAP
ARCH. ASPHALT SHINGLES
HIP
VALLEY
STANDING SEAM METAL ROOF
12" OVERHANG TYP.
DORMER
CRICKET
CHIMNEY CAP
ARCH. ASPHALT SHINGLES
12" OVERHANG TYP.
RIDGE CAP
HIP
VALLEY
HIP
ARCH. ASPHALT SHINGLES
RIDGE CAP
CHIMNEY CAP
CRICKET
STANDING SEAM METAL ROOF
ARCH. ASPHALT SHINGLES
12" OVERHANG TYP.
RIDGE CAP
STANDING SEAM METAL ROOF
CRICKET
CHIMNEY CAP
ARCH. ASPHALT SHINGLES
12" OVERHANG TYP.PROJECT TITLECONTENTSROOF PLANDATESHEETA 4.0GENERAL ROOF NOTES:
1.
2.
3.
4.
5.
6.
TYPICAL 12:12 PITCH FRONT TO BACK, 12:12 PITCH SIDE TO
SIDE. ASPHALT SHINGLES UNLESS OTHERWISE STATED.
TYPICAL 2:12 PITCH AT STANDING SEAM METAL ROOF.
PROVIDE SCREENED VENTS @ EACH 3RD JOIST SPACE @
ALL ATTIC EAVES.
USE 1/2" EXTERIOR PLYWOOD AT ALL EXPOSED EAVES.
USE ARCHITECTURAL ASPHALT SHINGLE ROOFING AND
UNDERLAY PER MANUFACTURERS SPECIFICATIONS
UNLESS NOTED OTHERWISE.
LOCATE ALL ROOF PENETRATING PLUMBING PIPES ON
THE "BACK" OF THE HOUSE.
NEW GUTTERS & DOWNSPOUTS THROUGHOUT HOUSE -
VERIFY W/ OWNER.
PROVIDE ATTIC VENTILATION AS APPROVED BY OWNER &
REQUIRED BY CODE BASE ON ATTIC AREA.
1 ROOF PLAN
1/4" = 1'-0"
GENERAL INSULATION NOTES:
1.
2.
3.
FLOORS OVER UNHEATED SPACE TO HAVE R-30 MIN INSULATION
BETWEEN JOISTS.
HVAC DUCTS LOCATED IN UNHEATED SPACES TO BE INSULATED
WITH R-8. CONTRACTOR TO VERIFY WITH LOCAL CODES.
ALL EXPOSED INSULATION TO HAVE A FLAME SPREAD RATING OF
LESS THAN 25 AND A SMOKE DENSITY RATING OF LESS THAN 450.COUNTRY CLUB6/4/25
12
12
2
12
12
12
12
12
12
12
12
12
12
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate
21'-2"7"Top of Parapet Wall
23'-7"2'-5"Top of Wall
32'-8 1/16"9'-1 1/16"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
19'-6 3/8"8'-0 1/2"Top of Wall
20'-7"1'-0 5/8"Top of Subfloor - 3rd Floor
21'-7"1'-0"Top of Parapet Wall
23'-7"2'-0"Top of Wall
29'-8 1/8"6'-1 1/8"Highest Ridge
36'-2 13/16"6'-6 11/16"12
12
2
12
12
12
12
12
12
12
12
12
12
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate
21'-2"7"Top of Parapet Wall
23'-7"2'-5"Top of Wall
32'-8 1/16"9'-1 1/16"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
19'-6 3/8"8'-0 1/2"Top of Wall
20'-7"1'-0 5/8"Top of Subfloor - 3rd Floor
21'-7"1'-0"Top of Parapet Wall
23'-7"2'-0"Top of Wall
29'-8 1/8"6'-1 1/8"Highest Ridge
36'-2 13/16"6'-6 11/16"8
12 12
12
2
12
8
12
8
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Header
8'-0 1/2"8'-0 1/2"Top of Wall
10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Wall
29'-8 1/8"9'-1 1/8"Highest Ridge
36'-2 13/16"6'-6 11/16"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate
21'-2"7"8
12 12
12
2
12
8
12
8
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Header
8'-0 1/2"8'-0 1/2"Top of Wall
10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Wall
29'-8 1/8"9'-1 1/8"Highest Ridge
36'-2 13/16"6'-6 11/16"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate
21'-2"7"PROJECT TITLECONTENTSELEVATIONSDATESHEETA 5.0GENERAL ELEVATION NOTES:
1.
2.
3.
EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT
ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS,
CHIMNEYS, PROJECTIONS AND PENETRATIONS AS
REQUIRED BY APPROVED CONSTRUCTION PRACTICES.
ALL PLUMBING AND MECHANICAL VENTS TO BE
LOCATED CLOSE TOGETHER WITHIN THE PROVIDED
CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE
NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC
VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED
TO CLOSELY MATCH THE ROOF COLOR.
CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS
TO ALLOW POSITIVE DRAINAGE AWAY FROM THE
BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY
MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER
AND DOWN SPOUT NEEDS.
2 NORTH ELEVATION
1/4" = 1'-0"
1 SOUTH ELEVATION
1/4" = 1'-0"COUNTRY CLUB6/4/25
8
12
8
1212
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Header
8'-0 1/2"8'-0 1/2"Top of Wall
10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
14'-6 3/8"3'-0 1/2"Top of Wall
20'-7"6'-0 5/8"Top of Subfloor - 3rd Floor
21'-7"1'-0"Header
28'-6 3/8"6'-11 3/8"Top of Wall
29'-8 1/8"1'-1 3/4"Highest Ridge
36'-2 13/16"6'-6 11/16"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"7"12:12
Top of Knee Wall/ Rafter Plate
21'-2"
8
12
8
1212
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Header
8'-0 1/2"8'-0 1/2"Top of Wall
10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
14'-6 3/8"3'-0 1/2"Top of Wall
20'-7"6'-0 5/8"Top of Subfloor - 3rd Floor
21'-7"1'-0"Header
28'-6 3/8"6'-11 3/8"Top of Wall
29'-8 1/8"1'-1 3/4"Highest Ridge
36'-2 13/16"6'-6 11/16"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"7"12:12
Top of Knee Wall/ Rafter Plate
21'-2"
8
12
12
12
8
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Header
3'-8 1/4"3'-8 1/4"Top of Wall
10'-1 1/8"6'-4 7/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate
21'-2"7"Top of Slab
-1'-8"
Top of Subfloor - 1st Floor
0'-0"1'-8"Header
8'-0 1/2"8'-0 1/2"Top of Wall
10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
19'-6 3/8"8'-0 1/2"Top of Wall
20'-7"1'-0 5/8"Top of Subfloor - 3rd Floor
21'-7"1'-0"Header
28'-6"6'-11"Top of Wall
29'-8 1/8"1'-2 1/8"Highest Ridge
36'-2 13/16"6'-6 11/16"12:12
8
12
12
12
8
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Header
3'-8 1/4"3'-8 1/4"Top of Wall
10'-1 1/8"6'-4 7/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate
21'-2"7"Top of Slab
-1'-8"
Top of Subfloor - 1st Floor
0'-0"1'-8"Header
8'-0 1/2"8'-0 1/2"Top of Wall
10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
19'-6 3/8"8'-0 1/2"Top of Wall
20'-7"1'-0 5/8"Top of Subfloor - 3rd Floor
21'-7"1'-0"Header
28'-6"6'-11"Top of Wall
29'-8 1/8"1'-2 1/8"Highest Ridge
36'-2 13/16"6'-6 11/16"12:12
PROJECT TITLECONTENTSELEVATIONSDATESHEETA 5.1GENERAL ELEVATION NOTES:
1.
2.
3.
EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT
ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS,
CHIMNEYS, PROJECTIONS AND PENETRATIONS AS
REQUIRED BY APPROVED CONSTRUCTION PRACTICES.
ALL PLUMBING AND MECHANICAL VENTS TO BE
LOCATED CLOSE TOGETHER WITHIN THE PROVIDED
CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE
NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC
VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED
TO CLOSELY MATCH THE ROOF COLOR.
CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS
TO ALLOW POSITIVE DRAINAGE AWAY FROM THE
BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY
MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER
AND DOWN SPOUT NEEDS.
2 WEST ELEVATION
1/4" = 1'-0"
1 EAST ELEVATION
1/4" = 1'-0"COUNTRY CLUB6/4/25
12
12
8
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate
21'-2"7"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
14'-6 3/8"3'-0 1/2"Top of Wall
20'-7"6'-0 5/8"Top of Subfloor - 3rd Floor
21'-7"1'-0"Header
28'-6 3/8"6'-11 3/8"ATTIC
DINING
MASTER
BEDROOM
FOYER
BEDROOM 3
LIVING
PORCH
STAIRS
STAIRS
STAIRS
BEDROOM 2
CLOSET CLOSETSITTING
OUTDOOR LIVING
BALCONY
ATTIC
12
12
8
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Wall
20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate
21'-2"7"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
14'-6 3/8"3'-0 1/2"Top of Wall
20'-7"6'-0 5/8"Top of Subfloor - 3rd Floor
21'-7"1'-0"Header
28'-6 3/8"6'-11 3/8"ATTIC
DINING
MASTER
BEDROOM
FOYER
BEDROOM 3
LIVING
PORCH
STAIRS
STAIRS
STAIRS
BEDROOM 2
CLOSET CLOSETSITTING
OUTDOOR LIVING
BALCONY
ATTIC
12
12
8
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Header
8'-0 1/2"8'-0 1/2"Top of Wall
10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
19'-6 3/8"8'-0 1/2"Top of Wall
20'-7"1'-0 5/8"Highest Ridge
36'-2 13/16"15'-7 13/16"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Lower Pony Wall
11'-10 3/8"4 1/2"Top of Wall
20'-7"8'-8 5/8"Top of Knee Wall/ Rafter Plate
21'-2"7"GARAGE
PLAYROOM
MASTER BATH
KITCHEN
ELEVATOR
LAUNDRY
WET BAR OUTDOOR LIVING
BALCONY
ATTIC
HER TLT
1/2 BATH CLOSET CLOSET
ATTIC
12
12
8
12
12
12
Top of Subfloor - 1st Floor
0'-0"
Header
8'-0 1/2"8'-0 1/2"Top of Wall
10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Header
19'-6 3/8"8'-0 1/2"Top of Wall
20'-7"1'-0 5/8"Highest Ridge
36'-2 13/16"15'-7 13/16"Top of Subfloor - 1st Floor
0'-0"
Top of Wall
10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor
11'-5 7/8"1'-4 3/4"Top of Lower Pony Wall
11'-10 3/8"4 1/2"Top of Wall
20'-7"8'-8 5/8"Top of Knee Wall/ Rafter Plate
21'-2"7"GARAGE
PLAYROOM
MASTER BATH
KITCHEN
ELEVATOR
LAUNDRY
WET BAR OUTDOOR LIVING
BALCONY
ATTIC
HER TLT
1/2 BATH CLOSET CLOSET
ATTIC
PROJECT TITLECONTENTSBUILDINGSECTIONDATESHEETA 6.0GENERAL ELEVATION NOTES:
1.
2.
3.
EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT
ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS,
CHIMNEYS, PROJECTIONS AND PENETRATIONS AS
REQUIRED BY APPROVED CONSTRUCTION PRACTICES.
ALL PLUMBING AND MECHANICAL VENTS TO BE
LOCATED CLOSE TOGETHER WITHIN THE PROVIDED
CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE
NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC
VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED
TO CLOSELY MATCH THE ROOF COLOR.
CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS
TO ALLOW POSITIVE DRAINAGE AWAY FROM THE
BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY
MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER
AND DOWN SPOUT NEEDS.
2 BUILDING SECTION 2
1/4" = 1'-0"
1 BUILDING SECTION 1
1/4" = 1'-0"COUNTRY CLUB6/4/25
SSSSSSSS23'-8 1/2"15'-5 1/2"
0'
39'-2"19'10'30'-8"33'92'-8"2'-8"24'
39'-2"
15'-2"5'-8"67'-8"22'95'-4"2'-10"7'-4"7'-4"10'-8 1/2"5'28'13'
24'7'3'7'-4"39'-2"
HOUSE SLAB
GARAGE SLAB
PORCH SLAB
PORCH SLAB
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
THICKENED SLAB FOOTING
W/ (2) #4 REBAR CONT. &
#4 REBAR @ 24" O.C. HORIZ.
AT LOAD BEARING INT. WALLS
THICKENED SLAB FOOTING
W/ (2) #4 REBAR CONT. &
#4 REBAR @ 24" O.C. HORIZ.
AT LOAD BEARING INT. WALLS
PROJECT TITLECONTENTSFOUNDATION PLANDATESHEETA 7.02 FOUNDATION PLAN
1/4" = 1'-0"
GENERAL FOUNDATION NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
CONTRACTOR TO INSPECT THE JOB SITE AND EXCAVATED
CONDITIONS PRIOR TO STARTING CONSTRUCTION.
CONTRACTOR TO NOTIFY DESIGNER AND ENGINEER OF ANY
CONDITIONS REGARDING SOILS, GROUND WATER, OR ANY
OTHER ISSUE WHICH MAY REQUIRE ADDITIONAL OR SPECIAL
ENGINEERING DESIGN BY A LICENSED STRUCTURAL
ENGINEER.
CONTRACTOR TO REVIEW PLANS, ELEVATIONS, AND DETAILS
FOR DIMENSION OF FINISH FLOOR ABOVE TYPICAL GRADE.
CONTRACTOR TO NOTIFY DESIGNER IF THERE ARE ANY SITE
CONDITIONS THAT REQUIRE MODIFICATIONS TO DIMENSIONS
INDICATED ON PLANS, SECTIONS, OR EXTERIOR ELEVATIONS.
CONTRACTOR TO VERIFY FOOTING DEPTHS WITH LOCAL
FROST REQUIREMENTS OR EXISTING SOIL CONDITIONS;
WHICH EVER IS MORE RESTRICTIVE.
ALL FOOTINGS TO REST ON UNDISTURBED SOIL.
CONTRACTOR TO COORDINATE WITH LICENSED, BONDED
INSTALLER TO PROVIDE TERMITE TREATMENT WHICH
COMPLIES WITH ALL LOCAL BUILDING CODES.
PROVIDE 1/2" EXPANSION JOINT MATERIAL BETWEEN ALL
CONCRETE SLABS ON ABUTTING CONCRETE OR MASONRY
WALL OCCURRING IN EXTERIOR OR UNHEATED INTERIOR
AREAS.
UNLESS OTHERWISE NOTED, ALL SLABS ON GRADE TO BE
3500 PSI CONCRETE ON 4" GRAVEL FILL MINIMUM, WITH
6x6-10/10 WIRE MESH REINFORCING. INTERIOR SLABS TO BE
PLACED ON 15 MIL. STABILIZED POLYETHYLENE VAPOR
BARRIER. THICKEN SLAB TO 12" AT LOAD BEARING WALLS.
PROVIDE 1/4" DEEP SCORE CONTROL JOINTS AT MID POINTS
OF ALL GARAGE SLABS, BOTH DIRECTIONS NOT MORE THAN
20' APART.COUNTRY CLUB6/4/25
ARCHITECTURAL ASPHALT SHINGLES
SYNTHETIC ROOFING UNDERLAYMENT
1/2" ZIP BOARD TAPED AT JOINTS
RAFTER PER CODE
MASONRY FIREPLACE
CRICKET
R-38 INSULATION
7" KNEE WALL
CEILING JOIST PER CODE
SUB-FASCIA
FASCIA
SOFFIT
2"X4" SILL PLATE
2"X4" STUD
BRICK VENEER
3 1/2" R-15 BATT INSULATION
1/2" ZIP BOARD TAPED AT JOINTS
2"X4" SILL PLATE
ENG. FLOOR TRUSS
HEADER
BRICK VENEER
ALUMINUM-CLAD WOOD WINDOW
2"X4" SILL PLATE
"L" BOLT
CMU BLOCK FOUNDATION
SLOPE FOR DRAINAGE
CONCRETE FOOTING 24"W X 16"D
VERIFY W/STRUCTURAL & SOILS
ENGINEERS
CONT. REBAR AS REQ.
4' CONC. SLAB
15 MIL STEGO WRAP
VAPOR BARRIER
CRUSHED STONE FILL
COMPACTED SOIL
CROWN MOLDING
INT. RECESSED LIGHT
5/8" GYP. BOARD
1/2" GYP. BOARD
WINDOW TRIM
BASEBOARD
FINISH FLOORING
TYPICAL WALL SECTION
SCALE 3/8"=1'
ARCHITECTURAL ASPHALT SHINGLES
SYNTHETIC ROOFING UNDERLAYMENT
1/2" ZIP BOARD TAPED AT JOINTS
RAFTER PER CODE
MASONRY FIREPLACE
CRICKET
R-38 INSULATION
7" KNEE WALL
CEILING JOIST PER CODE
SUB-FASCIA
FASCIA
SOFFIT
2"X4" SILL PLATE
2"X4" STUD
BRICK VENEER
3 1/2" R-15 BATT INSULATION
1/2" ZIP BOARD TAPED AT JOINTS
2"X4" SILL PLATE
ENG. FLOOR TRUSS
HEADER
BRICK VENEER
ALUMINUM-CLAD WOOD WINDOW
2"X4" SILL PLATE
"L" BOLT
CMU BLOCK FOUNDATION
SLOPE FOR DRAINAGE
CONCRETE FOOTING 24"W X 16"D
VERIFY W/STRUCTURAL & SOILS
ENGINEERS
CONT. REBAR AS REQ.
4' CONC. SLAB
15 MIL STEGO WRAP
VAPOR BARRIER
CRUSHED STONE FILL
COMPACTED SOIL
CROWN MOLDING
INT. RECESSED LIGHT
5/8" GYP. BOARD
1/2" GYP. BOARD
WINDOW TRIM
BASEBOARD
FINISH FLOORING
TYPICAL WALL SECTION
SCALE 3/8"=1'PROJECT TITLECONTENTSDETAILSDATESHEETA 7.1GENERAL FRAMING NOTES:
1.
2.
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL
WORK AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT
FEDERAL, STATE & LOCAL CODES, ORDINANCES AND
REGULATIONS, ETC. THESE ARE TO BE CONSIDERED AS PART OF
THE SPECIFICATIONS OF THE BUILDING AND SHOULD BE ADHERED
TO EVEN IF THEY ARE IN VARIANCE WITH THE PLAN.
THE STRUCTURAL DATA SHOWN ON THE PLAN IS FOR REFERENCE
ONLY. GENERAL CONTRACTOR IS TO HAVE A LICENSED
STRUCTURAL ENGINEER REVIEW ALL STRUCTURAL ELEMENTS
SUCH AS JOIST SIZE & SPACING, BEAM AND HEADER SIZES, BEAM
CONNECTIONS, ETC.
*VERIFY FINAL SIZES WITH JOIST & BEAM MANUFACTURER.
GENERAL FRAMING NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL WOOD FRAMING IN CONTACT WITH CONCRETE OR
MASONRY TO BE PRESSURE TREATED.
ALL STUD WALLS TO BE FRAMED 16" O.C.
ALL ANGLED WALLS TO BE FRAMED AT 45 DEGREE ANGLE
UNLESS OTHERWISE NOTED.
MINIMUM HEADER SIZE AT SECOND AND THIRD FLOORS TO
BE (2) 2x6'S UNLESS OTHERWISE NOTED.
PROVIDE FULL SOLID BEARING OR STUD BEARING UNDER ALL
BEAM BEARING POINTS.
ALL BEAMS TO HAVE TRIPLE STUD BEARING AT EACH END.
ALL STRUCTURAL STEEL TO CONFORM WITH ASTM
SPECIFICATIONS A-36.
STAIR CONSTRUCTION TO CONSIST OF (3) 2x12 STRINGERS,
5/4" OR 2x THICK TREADS & 3/4" THICK RISERS OR MATERIALS
FABRICATED BY A COMPONENT MANUFACTURER.
HANDRAILS TO BE MOUNTED 32"-34" ABOVE STAIR NOSING.
GUARDRAILS TO BE MOUNTED AT 36" HEIGHT.
FLOOR FRAMING LAYOUT TO BE COORDINATED WITH THE
GENERAL AND HVAC CONTRACTORS TO PROVIDE ACCESS
CHASES AND UNOBSTRUCTED RUNS FOR HVAC DUCT WORK.COUNTRY CLUB6/4/25