HomeMy WebLinkAboutPrefinal Construction Set4920 COUNTRY CLUB BLVD LITTLE ROCK, ARKANSAS 6/4/2025 6/4/25COUNTRY CLUB GENERAL SITE NOTES: 1. 2. 3. 4. GENERAL CONTRACTOR TO VERIFY THE EXISTING TOPOGRAPHIC GRADE LEVELS, LOCATIONS OF TREES, AND THE PROPOSED BUILDING LOCATIONS. CONTRACTOR TO NOTIFY DESIGNER OF SITE CONDITIONS PRIOR TO START OF CONSTRUCTION. GENERAL CONTRACTOR TO HAVE A LICENSED ENGINEER OR LICENSED SURVEYOR STAKE OUT OR VERIFY THE BUILDING LOCATION TO ENSURE THAT THE BUILDING DOES NOT ENCROACH ON ANY SETBACKS OR EASEMENTS, UNLESS THE ENCROACHMENT IS ALLOWED BY ZONING AND BUILDING CODES. CONTRACTOR TO NOTIFY DESIGNER IF ANY ENCROACHMENT ISSUES PRIOR TO START OF CONSTRUCTION. GENERAL CONTRACTOR TO LOCATE ALL UTILITY SERVICES, I.E. WATER, SEWER, GAS, ELECTRICAL, TELEPHONE, CABLE TV, AND COORDINATE THE EXTENSIONS TO THE BUILDING WITH THE APPROPRIATE INSTALLER. GENERAL CONTRACTOR TO COORDINATE FINISH TOPOGRAPHIC GRADING AND PAVING OF WALKS, DRIVEWAYS, PATIOS, ETC. AS REQUIRED FOR POSITIVE DRAINAGE AWAY FROM THE BUILDING. GENERAL CONSTRUCTION NOTES: 1. 2. 3. 4. 5. 6. 7. GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS. GENERAL CONTRACTOR TO COORDINATE SITE GRADING & DRAINAGE WITH OWNER & GEOTECH ENGINEER OR CIVIL ENGINEER. GENERAL CONTRACTOR TO VERIFY ALL CABINETRY WITH OWNER PRIOR TO INSTALLATION. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT FEDERAL, STATE AND LOCAL CODES, ORDINANCES AND REGULATIONS, ETC. THESE ARE TO BE CONSIDERED AS PART OF THE SPECIFICATIONS OF THIS BUILDING AND SHOULD BE ADHERED TO EVEN IF THEY ARE IN VARIANCE WITH THE PLAN. THE STRUCTURAL DATA SHOWN ON THE PLANS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO HAVE A LICENSED STRUCTURAL ENGINEER REVIEW ALL STRUCTURAL ELEMENTS SUCH AS JOIST SIZE AND SPACING, BEAM & HEADER SIZES, BEAM CONNECTIONS, ETC. CONTRACTOR TO ENSURE THAT PRE-FAB FIREPLACE CONSTRUCTION MEETS OR EXCEEDS ALL APPLICABLE CODES. FLUE HEIGHT TO MEET NECESSARY HEIGHT TO COMPLY WITH LOCAL CODES. CONTRACTOR TO COORDINATE GAS SERVICE REQUIREMENTS WITH THE CITY. N 5'-0 1/2" 5'-0 1/2"95'-9"39'-11" FIPFIP FIP FIP 50.0' M&P 50.0' M&P138.77' M, 140.0 P138.0' M, 140.0 PPROPOSED NEW TWO STORY RESIDENCE 4834 SF COUNTRY CLUB BLVD (80' ROW) 5 4 9 5 4 8 547 546 5 4 6 5465455445435 4 2 5 4 1 540 539 NEW DRIVEWAY EXISTING RESIDENCE EXISTING GARAGE NEW POOLNEW 4' HIGH RETAINING WALL LOT 7 NEW PATIO PROJECT TITLEA 1.0COUNTRY CLUBCONTENTSSITE PLAN DATESHEET1 SITE PLAN 1/8" = 1'-0"6/4/25 SB5221B44 4'X11' ISLANDSB36B24RDWB24RB24RSB36 B42B42B31 LCB4824LLCB2448R B57B57B57B572DB45182DB45182DB4518B44B44 SB33 B40LCB4036RB31 GRILLSMOKER BUILT-INSBUILT-INSSB5221B44 4'X11' ISLANDSB36B24RDWB24RB24RSB36 B42B42B31 LCB4824LLCB2448R B57B57B57B572DB45182DB45182DB4518B44B44 SB33 B40LCB4036RB31 GRILLSMOKER BUILT-INSBUILT-INSU482490 REF U571596U571596W4242W4242W5742W5342W2478W6478W5342W5342W5342W4442 W4442 W44425480 2870SC 6080 6080 2870SC 3070SC3070SC3050SC3040SC90809080 1070FX 2640SC 2640SC 30804080 3080 2468308030802680288015080 CASED OPENING 8898 ARCH FIREPLACE2870FX2870FX2870FX1070FX 8090 3070SC3070FX3070SC3040SC3040SCFIREPLACE3080UP cLcLcLE1 10 E1 10Exterior Elevation Front E2 11 E2 11 Exterior Elevation LeftE3 10 E3 10 Exterior Elevation Back E4 11 E4 11 Exterior Elevation RightBS1 12 BS1 12 BS1 12 BS1 12BUILDING SECTION 1BS2 12 BS2 12 BS2 12 BS2 12 BUILDING SECTION 2E5 14 E5 14DETAILS 4'-5 3/4"4'-2 1/4"4'-2"3'3'4'-2"7'-8"4'-5 3/4"4'-5 3/4"11'-4 1/2"7'-7 1/2"7'-4"4'-4"9'-10 1/2"18'-3 1/2"4'-10"4'-2" 6'-2"11'-8"5'-10 1/2"7'-8 3/4"7'-8 3/4"2'-4" 23'-8 1/2"15'-5 1/2" 39'-2" 2'-6"10'19'11'-8"33'80'-4"7'2'-8"2'-4"2'-8"2'-8"2'-4"5'-8"3'-6"10'11'-10"4'-8"8'-11 1/2"5'-8 1/2"8'-8"14'-4"22'73'-4"15'-2" 39'-2" 5'6'-8"5'5'-5" 24' 2'-4" 24' 41'-6"6'-8"7'-8"12'-4"92'-8"1'-4"1'-4"1'-4"4'-3 1/2"1'-4"2'-8 1/2"1'-4" 15'-2" 4'-8"4'-8"5'13'6'5' 5'-4"9'-10"5'28'7'-4" 7'-4"4'-4"7'20'-6"7'-4"6'-4"23'-4"3'95'-4"1'-11" 11'-4" 3'-6"4'-8 1/2" 21'-2" X 21'-8" 19'-11" X 23'-0" 23'-4" X 27'-8" 17'-2" X 24'-11" 12'-8" X 5'-0" 5'-4" X 4'-8" 7'-0" X 18'-4" 7'-0" X 11'-4" 11'-0" X 5'-8" 19'-10" X 13'-8" 14'-1" X 4'-7" 14'-1" X 9'-3" 11'-4" X 24'-0" 1910 SQ FT GARAGE MUD PANTRY DINING PORCH ELEV. LIVINGKITCHEN FOYER OUTDOOR LIVING WET BAR 12" TREADS LIVING AREA OUTDOOR LIVING GARAGE PROJECT TITLECONTENTSFLOOR PLAN BASEMENT LEVELDATESHEETA 2.0GENERAL FLOOR PLAN NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER. ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD, WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND. ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET AREAS TO HAVE WATER RESISTANT GYPSUM BOARD. BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM NET CLEAR OPERABLE HEIGHT OF 24" AND HAVE A MAXIMUM FINISH SILL HEIGHT OF 44" FROM FINISH FLOOR. ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR SHOWERS TO BE TEMPERED. BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO THE OUTSIDE AS REQUIRED BY CODE. ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED. ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES. GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH SELECTED MANUFACTURER(S). GENERAL HVAC SYSTEM NOTES: 1. 2. 3. 4. MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT SUPPLIER FOR FINAL REVIEW AND APPROVAL PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD, AND THE DRYER VENT. LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR. GENERAL PLUMBING NOTES: 1. 2. 3. 4. 5. PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC EQUIPMENT AS REQUIRED. IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO TIE FRAMING BACK TOGETHER. ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT. ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY DESIGNER PRIOR TO START OF CONSTRUCTION. 1 LEVEL 1 1/4" = 1'-0"COUNTRY CLUB6/4/25 DN 3DB2521 SB3421SB2721R SB30213DB2521 SB32213DB1821DESK 3DB25303DB25301DB2721103DB18213DB18213DB1821SB32213DB18213DB1821B30B62B30B30 SB32213DB1921 3DB1921 3DB1721 3DB1721 3DB2521 SB3421SB2721R SB30213DB2521 SB32213DB1821DESK 3DB25303DB25301DB2721103DB18213DB18213DB1821SB32213DB18213DB1821B30B62B30B30 SB32213DB1921 3DB1921 3DB1721 3DB1721LINEN U361590U361590U361590 U462790U462790U362490 W3042W3142W3042W3042W3142 2460SC2460FX2460SC368030803080 3060SC3060SC3016FX3060SC3050FX3016FX3080 6080 3080 3016FX 3016FX 3060SC3060SC2440FX3060SC3040SC3040SC5050FX3016FX30802880 30802460SC2460FX2460SC 2050FX2050FX2050FX 24802480 3080248024802880 3080 28802480 2880 2680268026802480 14080 2068206820682068UP 3'2'-10"2'-6"11'2'-6"4'-2"4'8'2'-8"4'-10"5'-10"6'-2"1'-10"4'-2"5'-2"1'-8"2'-4"2'-4"1'-8"3'-10"2'-4"2'-4"5'-10"1'-6"2'2'1'-6" 14'-4"7'2'-4 1/2"3'-8 3/4"8'3'-8 3/4" 39'-2"5'-1 3/4"5'-1 3/4"6'-8"10'-3 1/2"4'-10 1/2"8'4'8'7'-6"12'6'13'2'80'-4"4'-8"2'-8"1'-8"2'-4"2'-2"7'-5 3/4"7'-2 1/4"4'-6"10'-10"1'-8"13'3'-6"4'-6"14'-8"15'-4"3'-6"5'-10"16'6'-8"4'-8"97'2'7'-8 3/4"10'-2 3/4" 2'-6"17'-11 1/2"3'-6 1/2"3'-6"11'-8" 39'-2" 24'15'-2" 10'3'-4"5'-8"5'5'10'-2" 12'1'6' 7' 20'-2" 11'-8"7'-4"5'15'-2" 7'12' 5'5'-8"9'-6" 5'-6" 7'6'4'5'5'5'-6"8'13'12'-4"94'-8"97'2'-4"7'-8"3'4'-10"7'-2 1/2"2'-4 1/2"2'-1" 14'-10" X 15'-0" 2924 SQ FT 11'-5" X 16'-7" 14'-10" X 12'-8" 5'-10" X 7'-7" 14'-10" X 14'-4" 23'-4" X 12'-8" 4'-8" X 7'-7" 9'-8" X 5'-8"5'-0" X 5'-8" 11'-8" X 11'-8" 5'-4" X 4'-8" 6'-4" X 4'-8" 18'-4" X 7'-2" 19'-10" X 15'-4" 5'-1" X 9'-0"5'-4" X 9'-0" 11'-3" X 7'-8" 11'-4" X 9'-7" 6'-8" X 3'-8" 3'-2" X 6'- 4" 24'-1" X 12'-0" 19'-10" X 6'-4" 6'-8" X 4'-8" 7'-0" X 7'-6" OPEN BELOW BEDROOM 3 PLAYROOM BEDROOM 4 LAUNDRY 1/2 BATH ELEV. BALCONY BATH 4 CLOSET BEDROOM 2HIS MASTER BATH HIS TLT HER TLT HERS CLOSET BATH 2 MASTER BDRM SITTING TUB SHOWER CLOSET BATH 3 12" TREADS LIVING AREA PROJECT TITLECONTENTSFLOOR PLAN LEVEL 2DATESHEETA 2.0MAIN LEVEL H/C SECOND LEVEL H/C TOTAL H/C MAIN LEVEL PORCHES 1910 SF 2924 SF 4834 SF 769 SF 284 SF 1053 SF 1369 SF 7256 SF GENERAL FLOOR PLAN NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER. ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD, WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND. ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET AREAS TO HAVE WATER RESISTANT GYPSUM BOARD. BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM NET CLEAR OPERABLE HEIGHT OF 24" AND HAVE A MAXIMUM FINISH SILL HEIGHT OF 44" FROM FINISH FLOOR. ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR SHOWERS TO BE TEMPERED. BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO THE OUTSIDE AS REQUIRED BY CODE. ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED. ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES. GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH SELECTED MANUFACTURER(S). GENERAL HVAC SYSTEM NOTES: 1. 2. 3. 4. MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT SUPPLIER FOR FINAL REVIEW AND APPROVAL PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD, AND THE DRYER VENT. LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR. GENERAL PLUMBING NOTES: 1. 2. 3. 4. 5. PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC EQUIPMENT AS REQUIRED. IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO TIE FRAMING BACK TOGETHER. ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT. ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY DESIGNER PRIOR TO START OF CONSTRUCTION. 1 LEVEL 2 1/4" = 1'-0" SECOND LEVEL PORCHES TOTAL PORCHES 2-CAR GARAGE TOTAL UNDER ROOF COUNTRY CLUB6/4/25 DN3068 3050FX2026FX 15'-5 1/2"14'-11 1/2"7'-5 3/4"7'-5 3/4"14'-11 1/2"15'-5 1/2"6'-6"17'-11"3'-4"17'-11" 37 SQ FT 14'-10" X 14'-4" OPEN BELOW ATTIC ACCESS LIVING AREA PROJECT TITLECONTENTSFLOOR PLAN LEVEL 3DATESHEETA 2.0GENERAL FLOOR PLAN NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER. ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD, WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND. ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET AREAS TO HAVE WATER RESISTANT GYPSUM BOARD. BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 24", A MINIMUM NET CLEAR OPERABLE HEIGHT OF 22" AND HAVE A MAXIMUM FINISH SILL HEIGHT OF 44" FROM FINISH FLOOR. ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR SHOWERS TO BE TEMPERED. BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO THE OUTSIDE AS REQUIRED BY CODE. ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED. ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES. GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH SELECTED MANUFACTURER(S). GENERAL HVAC SYSTEM NOTES: 1. 2. 3. 4. MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT SUPPLIER FOR FINAL REVIEW AND APPROVAL PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD, AND THE DRYER VENT. LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR. GENERAL PLUMBING NOTES: 1. 2. 3. 4. 5. PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC EQUIPMENT AS REQUIRED. IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO TIE FRAMING BACK TOGETHER. ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT. ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY DESIGNER PRIOR TO START OF CONSTRUCTION. 1 LEVEL 3 W/OVERLAY 1/4" = 1'-0"COUNTRY CLUB6/4/25 R6 R6 R6 R6 R6 R6R6 R6 R6R6 R6 R6 R6 R6R6 R6 R6 R6R6 R6 R6 R6 R6R6 R6R6 R6 R6R6 R6R6 R6R6 R6 R6R6 R6 R6R6R6 R6R6R6 R6 R6 R6R6 R6 R6 R6 R6R6 10'-0" CEILING FAN STAINED T&G CEILING RECESSED LIGHT GYP. BOARD TYP. INT. RECESSED LIGHT GYP. BOARD TYP. LINEAR SHOP LIGHT CHANDELIER INT. RECESSED LIGHT GYP. BOARD TYP. CEILING FAN VANITY LIGHT 10'-0" 10'-0" 10'-0"10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" INT. RECESSED LIGHT GYP. BOARD TYP. PENDANT LIGHT RECESSED LIGHT STAINED T&G CEILING WALL SCONCE ELECTRICAL SCHEDULE DESCRIPTION 2D SY MB OL ELEGANT PENDANT WROUGHT IRON CANDELABRA SHOP LIGHT (LONG) [72W] LOWE WALL SCONCE TRADITIONAL FLUSH DOME WALL SCONCE 3 CLASSIC CEILING FAN EXHAUST FAN RECESSED DOWN LIGHT 6 R6R6 PROJECT TITLECONTENTSREFLECTED CEILINGPLAN-LEVEL 1DATESHEETA 3.0GENERAL ELECTRICAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE THE INSTALLATION OF FIXTURES, SWITCHES, ETC. GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER, DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES. ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I. TYPE PER CODE. SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND COLOR MATCHED WITH THE INTERIOR TRIM. CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS, COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT. CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS. VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH EACH OTHER IF THERE ARE MULTIPLE SWITCHES. CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND EXTERIOR LIGHTING CIRCUITS AND SWITCHES. PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP, ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS. G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER. 1 LEVEL 1 RCP 1/4" = 1'-0" REFLECTED CEILING LEGEND COUNTRY CLUB6/4/25 R6R6 R6 R6 R6 R6R6 R6 R6R6 R6 R6 R6R6 R6 R6R6 R6 R6 R6 R6 R6R6 R6 R6 R6 R6 R6 R6 R6 R6R6R6 R6 R6 R6 R6 R6 R6R6 R6 R6 R6 R6 R6 R6 R6 R6R6R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 R6 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0"9'-0" 9'-0" 9'-0"SURFACE MOUNTED LIGHT EXHAUST FAN VANITY LIGHT GYP. BOARD TYP. INT. RECESSED LIGHT INT. RECESSED LIGHT CEILING FAN SURFACE MOUNTED LIGHT GYP. BOARD TYP. CEILING FAN STAINED T&G CEILING CEILING FAN RECESSED LIGHT GYP. BOARD TYP. INT. RECESSED LIGHT CEILING FAN VANITY LIGHT SURFACE MOUNTED LIGHT EXHAUST FAN VANITY LIGHT EXHAUST FAN SURFACE MOUNTED LIGHT INT. RECESSED LIGHT CEILING FAN ELECTRICAL SCHEDULE DESCRIPTION 2D SY MB OL ELEGANT PENDANT WROUGHT IRON CANDELABRA SHOP LIGHT (LONG) [72W] LOWE WALL SCONCE TRADITIONAL FLUSH DOME WALL SCONCE 3 CLASSIC CEILING FAN EXHAUST FAN RECESSED DOWN LIGHT 6 R6R6 PROJECT TITLECONTENTSREFLECTED CEILINGPLAN-LEVEL 2DATESHEETA 3.1REFLECTED CEILING LEGEND 1 LEVEL 2 RCP 3/16" = 1'-0" GENERAL ELECTRICAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE THE INSTALLATION OF FIXTURES, SWITCHES, ETC. GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER, DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES. ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I. TYPE PER CODE. SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND COLOR MATCHED WITH THE INTERIOR TRIM. CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS, COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT. CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS. VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH EACH OTHER IF THERE ARE MULTIPLE SWITCHES. CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND EXTERIOR LIGHTING CIRCUITS AND SWITCHES. PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP, ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS. G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER.COUNTRY CLUB6/4/25 R6 R6R6 R6 ATTIC ACCESS GYP. BOARD TYP. INT. RECESSED LIGHT ELECTRICAL SCHEDULE DESCRIPTION 2D SY MB OL ELEGANT PENDANT WROUGHT IRON CANDELABRA SHOP LIGHT (LONG) [72W] LOWE WALL SCONCE TRADITIONAL FLUSH DOME WALL SCONCE 3 CLASSIC CEILING FAN EXHAUST FAN RECESSED DOWN LIGHT 6 R6R6 PROJECT TITLECONTENTSREFLECTED CEILINGPLAN-LEVEL 3DATESHEETA 3.2REFLECTED CEILING LEGEND GENERAL ELECTRICAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE THE INSTALLATION OF FIXTURES, SWITCHES, ETC. GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER, DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES. ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I. TYPE PER CODE. SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND COLOR MATCHED WITH THE INTERIOR TRIM. CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS, COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT. CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS. VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH EACH OTHER IF THERE ARE MULTIPLE SWITCHES. CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND EXTERIOR LIGHTING CIRCUITS AND SWITCHES. PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP, ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS. G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER. 1 LEVEL 3 RCP 3/16" = 1'-0"COUNTRY CLUB6/4/25 12 : 12 12 : 12 12 : 128 : 128 : 12 8 : 128 : 12 12 : 1212 : 12 12 : 12 8 : 1212 : 1212 : 12 12 : 12 12 : 12 12 : 12 8 : 12 2 : 12 RIDGE CAP ARCH. ASPHALT SHINGLES HIP VALLEY STANDING SEAM METAL ROOF 12" OVERHANG TYP. DORMER CRICKET CHIMNEY CAP ARCH. ASPHALT SHINGLES 12" OVERHANG TYP. RIDGE CAP HIP VALLEY HIP ARCH. ASPHALT SHINGLES RIDGE CAP CHIMNEY CAP CRICKET STANDING SEAM METAL ROOF ARCH. ASPHALT SHINGLES 12" OVERHANG TYP. RIDGE CAP STANDING SEAM METAL ROOF CRICKET CHIMNEY CAP ARCH. ASPHALT SHINGLES 12" OVERHANG TYP.PROJECT TITLECONTENTSROOF PLANDATESHEETA 4.0GENERAL ROOF NOTES: 1. 2. 3. 4. 5. 6. TYPICAL 12:12 PITCH FRONT TO BACK, 12:12 PITCH SIDE TO SIDE. ASPHALT SHINGLES UNLESS OTHERWISE STATED. TYPICAL 2:12 PITCH AT STANDING SEAM METAL ROOF. PROVIDE SCREENED VENTS @ EACH 3RD JOIST SPACE @ ALL ATTIC EAVES. USE 1/2" EXTERIOR PLYWOOD AT ALL EXPOSED EAVES. USE ARCHITECTURAL ASPHALT SHINGLE ROOFING AND UNDERLAY PER MANUFACTURERS SPECIFICATIONS UNLESS NOTED OTHERWISE. LOCATE ALL ROOF PENETRATING PLUMBING PIPES ON THE "BACK" OF THE HOUSE. NEW GUTTERS & DOWNSPOUTS THROUGHOUT HOUSE - VERIFY W/ OWNER. PROVIDE ATTIC VENTILATION AS APPROVED BY OWNER & REQUIRED BY CODE BASE ON ATTIC AREA. 1 ROOF PLAN 1/4" = 1'-0" GENERAL INSULATION NOTES: 1. 2. 3. FLOORS OVER UNHEATED SPACE TO HAVE R-30 MIN INSULATION BETWEEN JOISTS. HVAC DUCTS LOCATED IN UNHEATED SPACES TO BE INSULATED WITH R-8. CONTRACTOR TO VERIFY WITH LOCAL CODES. ALL EXPOSED INSULATION TO HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DENSITY RATING OF LESS THAN 450.COUNTRY CLUB6/4/25 12 12 2 12 12 12 12 12 12 12 12 12 12 12 12 12 Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate 21'-2"7"Top of Parapet Wall 23'-7"2'-5"Top of Wall 32'-8 1/16"9'-1 1/16"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 19'-6 3/8"8'-0 1/2"Top of Wall 20'-7"1'-0 5/8"Top of Subfloor - 3rd Floor 21'-7"1'-0"Top of Parapet Wall 23'-7"2'-0"Top of Wall 29'-8 1/8"6'-1 1/8"Highest Ridge 36'-2 13/16"6'-6 11/16"12 12 2 12 12 12 12 12 12 12 12 12 12 12 12 12 Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate 21'-2"7"Top of Parapet Wall 23'-7"2'-5"Top of Wall 32'-8 1/16"9'-1 1/16"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 19'-6 3/8"8'-0 1/2"Top of Wall 20'-7"1'-0 5/8"Top of Subfloor - 3rd Floor 21'-7"1'-0"Top of Parapet Wall 23'-7"2'-0"Top of Wall 29'-8 1/8"6'-1 1/8"Highest Ridge 36'-2 13/16"6'-6 11/16"8 12 12 12 2 12 8 12 8 12 12 12 Top of Subfloor - 1st Floor 0'-0" Header 8'-0 1/2"8'-0 1/2"Top of Wall 10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Wall 29'-8 1/8"9'-1 1/8"Highest Ridge 36'-2 13/16"6'-6 11/16"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate 21'-2"7"8 12 12 12 2 12 8 12 8 12 12 12 Top of Subfloor - 1st Floor 0'-0" Header 8'-0 1/2"8'-0 1/2"Top of Wall 10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Wall 29'-8 1/8"9'-1 1/8"Highest Ridge 36'-2 13/16"6'-6 11/16"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate 21'-2"7"PROJECT TITLECONTENTSELEVATIONSDATESHEETA 5.0GENERAL ELEVATION NOTES: 1. 2. 3. EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS, CHIMNEYS, PROJECTIONS AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTION PRACTICES. ALL PLUMBING AND MECHANICAL VENTS TO BE LOCATED CLOSE TOGETHER WITHIN THE PROVIDED CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED TO CLOSELY MATCH THE ROOF COLOR. CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS TO ALLOW POSITIVE DRAINAGE AWAY FROM THE BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER AND DOWN SPOUT NEEDS. 2 NORTH ELEVATION 1/4" = 1'-0" 1 SOUTH ELEVATION 1/4" = 1'-0"COUNTRY CLUB6/4/25 8 12 8 1212 12 12 12 Top of Subfloor - 1st Floor 0'-0" Header 8'-0 1/2"8'-0 1/2"Top of Wall 10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 14'-6 3/8"3'-0 1/2"Top of Wall 20'-7"6'-0 5/8"Top of Subfloor - 3rd Floor 21'-7"1'-0"Header 28'-6 3/8"6'-11 3/8"Top of Wall 29'-8 1/8"1'-1 3/4"Highest Ridge 36'-2 13/16"6'-6 11/16"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"7"12:12 Top of Knee Wall/ Rafter Plate 21'-2" 8 12 8 1212 12 12 12 Top of Subfloor - 1st Floor 0'-0" Header 8'-0 1/2"8'-0 1/2"Top of Wall 10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 14'-6 3/8"3'-0 1/2"Top of Wall 20'-7"6'-0 5/8"Top of Subfloor - 3rd Floor 21'-7"1'-0"Header 28'-6 3/8"6'-11 3/8"Top of Wall 29'-8 1/8"1'-1 3/4"Highest Ridge 36'-2 13/16"6'-6 11/16"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"7"12:12 Top of Knee Wall/ Rafter Plate 21'-2" 8 12 12 12 8 12 12 12 Top of Subfloor - 1st Floor 0'-0" Header 3'-8 1/4"3'-8 1/4"Top of Wall 10'-1 1/8"6'-4 7/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate 21'-2"7"Top of Slab -1'-8" Top of Subfloor - 1st Floor 0'-0"1'-8"Header 8'-0 1/2"8'-0 1/2"Top of Wall 10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 19'-6 3/8"8'-0 1/2"Top of Wall 20'-7"1'-0 5/8"Top of Subfloor - 3rd Floor 21'-7"1'-0"Header 28'-6"6'-11"Top of Wall 29'-8 1/8"1'-2 1/8"Highest Ridge 36'-2 13/16"6'-6 11/16"12:12 8 12 12 12 8 12 12 12 Top of Subfloor - 1st Floor 0'-0" Header 3'-8 1/4"3'-8 1/4"Top of Wall 10'-1 1/8"6'-4 7/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate 21'-2"7"Top of Slab -1'-8" Top of Subfloor - 1st Floor 0'-0"1'-8"Header 8'-0 1/2"8'-0 1/2"Top of Wall 10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 19'-6 3/8"8'-0 1/2"Top of Wall 20'-7"1'-0 5/8"Top of Subfloor - 3rd Floor 21'-7"1'-0"Header 28'-6"6'-11"Top of Wall 29'-8 1/8"1'-2 1/8"Highest Ridge 36'-2 13/16"6'-6 11/16"12:12 PROJECT TITLECONTENTSELEVATIONSDATESHEETA 5.1GENERAL ELEVATION NOTES: 1. 2. 3. EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS, CHIMNEYS, PROJECTIONS AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTION PRACTICES. ALL PLUMBING AND MECHANICAL VENTS TO BE LOCATED CLOSE TOGETHER WITHIN THE PROVIDED CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED TO CLOSELY MATCH THE ROOF COLOR. CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS TO ALLOW POSITIVE DRAINAGE AWAY FROM THE BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER AND DOWN SPOUT NEEDS. 2 WEST ELEVATION 1/4" = 1'-0" 1 EAST ELEVATION 1/4" = 1'-0"COUNTRY CLUB6/4/25 12 12 8 12 12 12 Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate 21'-2"7"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 14'-6 3/8"3'-0 1/2"Top of Wall 20'-7"6'-0 5/8"Top of Subfloor - 3rd Floor 21'-7"1'-0"Header 28'-6 3/8"6'-11 3/8"ATTIC DINING MASTER BEDROOM FOYER BEDROOM 3 LIVING PORCH STAIRS STAIRS STAIRS BEDROOM 2 CLOSET CLOSETSITTING OUTDOOR LIVING BALCONY ATTIC 12 12 8 12 12 12 Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Wall 20'-7"9'-1 1/8"Top of Knee Wall/ Rafter Plate 21'-2"7"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 14'-6 3/8"3'-0 1/2"Top of Wall 20'-7"6'-0 5/8"Top of Subfloor - 3rd Floor 21'-7"1'-0"Header 28'-6 3/8"6'-11 3/8"ATTIC DINING MASTER BEDROOM FOYER BEDROOM 3 LIVING PORCH STAIRS STAIRS STAIRS BEDROOM 2 CLOSET CLOSETSITTING OUTDOOR LIVING BALCONY ATTIC 12 12 8 12 12 12 Top of Subfloor - 1st Floor 0'-0" Header 8'-0 1/2"8'-0 1/2"Top of Wall 10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 19'-6 3/8"8'-0 1/2"Top of Wall 20'-7"1'-0 5/8"Highest Ridge 36'-2 13/16"15'-7 13/16"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Lower Pony Wall 11'-10 3/8"4 1/2"Top of Wall 20'-7"8'-8 5/8"Top of Knee Wall/ Rafter Plate 21'-2"7"GARAGE PLAYROOM MASTER BATH KITCHEN ELEVATOR LAUNDRY WET BAR OUTDOOR LIVING BALCONY ATTIC HER TLT 1/2 BATH CLOSET CLOSET ATTIC 12 12 8 12 12 12 Top of Subfloor - 1st Floor 0'-0" Header 8'-0 1/2"8'-0 1/2"Top of Wall 10'-1 1/8"2'-0 5/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Header 19'-6 3/8"8'-0 1/2"Top of Wall 20'-7"1'-0 5/8"Highest Ridge 36'-2 13/16"15'-7 13/16"Top of Subfloor - 1st Floor 0'-0" Top of Wall 10'-1 1/8"10'-1 1/8"Top of Subfloor - 2nd Floor 11'-5 7/8"1'-4 3/4"Top of Lower Pony Wall 11'-10 3/8"4 1/2"Top of Wall 20'-7"8'-8 5/8"Top of Knee Wall/ Rafter Plate 21'-2"7"GARAGE PLAYROOM MASTER BATH KITCHEN ELEVATOR LAUNDRY WET BAR OUTDOOR LIVING BALCONY ATTIC HER TLT 1/2 BATH CLOSET CLOSET ATTIC PROJECT TITLECONTENTSBUILDINGSECTIONDATESHEETA 6.0GENERAL ELEVATION NOTES: 1. 2. 3. EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT ALL CHIMNEY CONNECTIONS BETWEEN ROOFS, WALLS, CHIMNEYS, PROJECTIONS AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTION PRACTICES. ALL PLUMBING AND MECHANICAL VENTS TO BE LOCATED CLOSE TOGETHER WITHIN THE PROVIDED CHASE SPACE WHEN POSSIBLE TO MINIMIZE THE NUMBER OF ROOF PENETRATIONS. ALL METAL AND PVC VENTS AND PENETRATIONS TO BE PRIMED AND PAINTED TO CLOSELY MATCH THE ROOF COLOR. CONTRACTOR TO LOCATE GUTTERS AND DOWN SPOUTS TO ALLOW POSITIVE DRAINAGE AWAY FROM THE BUILDING. GUTTERS AND DOWN SPOUTS TO CLOSELY MATCH TRIM COLOR. VERIFY WITH OWNER ON GUTTER AND DOWN SPOUT NEEDS. 2 BUILDING SECTION 2 1/4" = 1'-0" 1 BUILDING SECTION 1 1/4" = 1'-0"COUNTRY CLUB6/4/25 SSSSSSSS23'-8 1/2"15'-5 1/2" 0' 39'-2"19'10'30'-8"33'92'-8"2'-8"24' 39'-2" 15'-2"5'-8"67'-8"22'95'-4"2'-10"7'-4"7'-4"10'-8 1/2"5'28'13' 24'7'3'7'-4"39'-2" HOUSE SLAB GARAGE SLAB PORCH SLAB PORCH SLAB 4" CONCRETE SLAB WITH 6"X6", #10/#10 W.W.M. OVER 15 MIL STEGO WRAP ON MIN. 4" COMPACTED FILL 4" CONCRETE SLAB WITH 6"X6", #10/#10 W.W.M. OVER 15 MIL STEGO WRAP ON MIN. 4" COMPACTED FILL 4" CONCRETE SLAB WITH 6"X6", #10/#10 W.W.M. OVER 15 MIL STEGO WRAP ON MIN. 4" COMPACTED FILL THICKENED SLAB FOOTING W/ (2) #4 REBAR CONT. & #4 REBAR @ 24" O.C. HORIZ. AT LOAD BEARING INT. WALLS THICKENED SLAB FOOTING W/ (2) #4 REBAR CONT. & #4 REBAR @ 24" O.C. HORIZ. AT LOAD BEARING INT. WALLS PROJECT TITLECONTENTSFOUNDATION PLANDATESHEETA 7.02 FOUNDATION PLAN 1/4" = 1'-0" GENERAL FOUNDATION NOTES: 1. 2. 3. 4. 5. 6. 7. 8. CONTRACTOR TO INSPECT THE JOB SITE AND EXCAVATED CONDITIONS PRIOR TO STARTING CONSTRUCTION. CONTRACTOR TO NOTIFY DESIGNER AND ENGINEER OF ANY CONDITIONS REGARDING SOILS, GROUND WATER, OR ANY OTHER ISSUE WHICH MAY REQUIRE ADDITIONAL OR SPECIAL ENGINEERING DESIGN BY A LICENSED STRUCTURAL ENGINEER. CONTRACTOR TO REVIEW PLANS, ELEVATIONS, AND DETAILS FOR DIMENSION OF FINISH FLOOR ABOVE TYPICAL GRADE. CONTRACTOR TO NOTIFY DESIGNER IF THERE ARE ANY SITE CONDITIONS THAT REQUIRE MODIFICATIONS TO DIMENSIONS INDICATED ON PLANS, SECTIONS, OR EXTERIOR ELEVATIONS. CONTRACTOR TO VERIFY FOOTING DEPTHS WITH LOCAL FROST REQUIREMENTS OR EXISTING SOIL CONDITIONS; WHICH EVER IS MORE RESTRICTIVE. ALL FOOTINGS TO REST ON UNDISTURBED SOIL. CONTRACTOR TO COORDINATE WITH LICENSED, BONDED INSTALLER TO PROVIDE TERMITE TREATMENT WHICH COMPLIES WITH ALL LOCAL BUILDING CODES. PROVIDE 1/2" EXPANSION JOINT MATERIAL BETWEEN ALL CONCRETE SLABS ON ABUTTING CONCRETE OR MASONRY WALL OCCURRING IN EXTERIOR OR UNHEATED INTERIOR AREAS. UNLESS OTHERWISE NOTED, ALL SLABS ON GRADE TO BE 3500 PSI CONCRETE ON 4" GRAVEL FILL MINIMUM, WITH 6x6-10/10 WIRE MESH REINFORCING. INTERIOR SLABS TO BE PLACED ON 15 MIL. STABILIZED POLYETHYLENE VAPOR BARRIER. THICKEN SLAB TO 12" AT LOAD BEARING WALLS. PROVIDE 1/4" DEEP SCORE CONTROL JOINTS AT MID POINTS OF ALL GARAGE SLABS, BOTH DIRECTIONS NOT MORE THAN 20' APART.COUNTRY CLUB6/4/25 ARCHITECTURAL ASPHALT SHINGLES SYNTHETIC ROOFING UNDERLAYMENT 1/2" ZIP BOARD TAPED AT JOINTS RAFTER PER CODE MASONRY FIREPLACE CRICKET R-38 INSULATION 7" KNEE WALL CEILING JOIST PER CODE SUB-FASCIA FASCIA SOFFIT 2"X4" SILL PLATE 2"X4" STUD BRICK VENEER 3 1/2" R-15 BATT INSULATION 1/2" ZIP BOARD TAPED AT JOINTS 2"X4" SILL PLATE ENG. FLOOR TRUSS HEADER BRICK VENEER ALUMINUM-CLAD WOOD WINDOW 2"X4" SILL PLATE "L" BOLT CMU BLOCK FOUNDATION SLOPE FOR DRAINAGE CONCRETE FOOTING 24"W X 16"D VERIFY W/STRUCTURAL & SOILS ENGINEERS CONT. REBAR AS REQ. 4' CONC. SLAB 15 MIL STEGO WRAP VAPOR BARRIER CRUSHED STONE FILL COMPACTED SOIL CROWN MOLDING INT. RECESSED LIGHT 5/8" GYP. BOARD 1/2" GYP. BOARD WINDOW TRIM BASEBOARD FINISH FLOORING TYPICAL WALL SECTION SCALE 3/8"=1' ARCHITECTURAL ASPHALT SHINGLES SYNTHETIC ROOFING UNDERLAYMENT 1/2" ZIP BOARD TAPED AT JOINTS RAFTER PER CODE MASONRY FIREPLACE CRICKET R-38 INSULATION 7" KNEE WALL CEILING JOIST PER CODE SUB-FASCIA FASCIA SOFFIT 2"X4" SILL PLATE 2"X4" STUD BRICK VENEER 3 1/2" R-15 BATT INSULATION 1/2" ZIP BOARD TAPED AT JOINTS 2"X4" SILL PLATE ENG. FLOOR TRUSS HEADER BRICK VENEER ALUMINUM-CLAD WOOD WINDOW 2"X4" SILL PLATE "L" BOLT CMU BLOCK FOUNDATION SLOPE FOR DRAINAGE CONCRETE FOOTING 24"W X 16"D VERIFY W/STRUCTURAL & SOILS ENGINEERS CONT. REBAR AS REQ. 4' CONC. SLAB 15 MIL STEGO WRAP VAPOR BARRIER CRUSHED STONE FILL COMPACTED SOIL CROWN MOLDING INT. RECESSED LIGHT 5/8" GYP. BOARD 1/2" GYP. BOARD WINDOW TRIM BASEBOARD FINISH FLOORING TYPICAL WALL SECTION SCALE 3/8"=1'PROJECT TITLECONTENTSDETAILSDATESHEETA 7.1GENERAL FRAMING NOTES: 1. 2. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT FEDERAL, STATE & LOCAL CODES, ORDINANCES AND REGULATIONS, ETC. THESE ARE TO BE CONSIDERED AS PART OF THE SPECIFICATIONS OF THE BUILDING AND SHOULD BE ADHERED TO EVEN IF THEY ARE IN VARIANCE WITH THE PLAN. THE STRUCTURAL DATA SHOWN ON THE PLAN IS FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO HAVE A LICENSED STRUCTURAL ENGINEER REVIEW ALL STRUCTURAL ELEMENTS SUCH AS JOIST SIZE & SPACING, BEAM AND HEADER SIZES, BEAM CONNECTIONS, ETC. *VERIFY FINAL SIZES WITH JOIST & BEAM MANUFACTURER. GENERAL FRAMING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ALL WOOD FRAMING IN CONTACT WITH CONCRETE OR MASONRY TO BE PRESSURE TREATED. ALL STUD WALLS TO BE FRAMED 16" O.C. ALL ANGLED WALLS TO BE FRAMED AT 45 DEGREE ANGLE UNLESS OTHERWISE NOTED. MINIMUM HEADER SIZE AT SECOND AND THIRD FLOORS TO BE (2) 2x6'S UNLESS OTHERWISE NOTED. PROVIDE FULL SOLID BEARING OR STUD BEARING UNDER ALL BEAM BEARING POINTS. ALL BEAMS TO HAVE TRIPLE STUD BEARING AT EACH END. ALL STRUCTURAL STEEL TO CONFORM WITH ASTM SPECIFICATIONS A-36. STAIR CONSTRUCTION TO CONSIST OF (3) 2x12 STRINGERS, 5/4" OR 2x THICK TREADS & 3/4" THICK RISERS OR MATERIALS FABRICATED BY A COMPONENT MANUFACTURER. HANDRAILS TO BE MOUNTED 32"-34" ABOVE STAIR NOSING. GUARDRAILS TO BE MOUNTED AT 36" HEIGHT. FLOOR FRAMING LAYOUT TO BE COORDINATED WITH THE GENERAL AND HVAC CONTRACTORS TO PROVIDE ACCESS CHASES AND UNOBSTRUCTED RUNS FOR HVAC DUCT WORK.COUNTRY CLUB6/4/25