HomeMy WebLinkAboutZ-10182 Elevations - REVISED 071625DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:7/15/2025 GENERAL NOTES: THIS PLAN SET, COMBINED WITH THE BUILDING CONTRACT, PROVIDES BUILDING DETAILS FOR THE RESIDENTIAL PROJECT.  THE CONTRACTOR SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. CONTRACTOR SHALL BE RESPONSIBLE AND BEAR ANY FINES OR PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS.  INSURANCES SHALL BE IN FORCE THROUGHOUT THE DURATION OF THE BUILDING PROJECT. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). ALL TRADES SHALL MAINTAIN A CLEAN WORK SITE AT THE END OF EACH WORK DAY. PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. OWNER: _______________________________ PROJECT: ADDRESS: __________________________________ LEGAL: ______________________________ FIRE DISTRICT _____________________________ WATER/SEWER: ____________________________ STORM WATER PERMIT: _____________________ BUILDING PERMIT: _____________________ DESIGNER: J. Duncan DESIGN CONSULTANT: _____________________ BUILDER: SITE DISTURBANCE: _____________________ ENGINEERING: _____________________ Index of DrawingsNOTICE, DISCLAIMER, AND COPYRIGHT: These documents, whether physical or electronic, and together with any attachments, Are confidential and may be the subject of legal privilege. If you are not the intended recipient please return to sender and destroy any copies. You are not permitted to copy, disclose or use the content in any way. J. Duncan provides the attached documents with the following conditions and understandings. All information is issued on the express understanding that the recipient accepts these limitations and disclaimers: 1 . The information must solely and only be used for the coordination and/or construction of the current project.   2 . J. Duncan does not warrant or take responsibility for the accuracy of the information issued.   3 . The information issued may be confidential and must not be used other than by the intended recipient.   4 . J. Duncan accepts no liability or responsibility for any loss or damage suffered by the recipient arising out of, or in connection with, the use or misuse of the information issued.   5 . The copyright of the original documents belongs to J. Duncan. The information is only for use in preparation of documents for this project.  6. The documents may not have been prepared for use by the recipient and may not fully reflect their needs.   7. Do not scale off drawings. Any measurements taken from information which is not dimensioned on the electronic copy are at the risk of the recipient.   8. The recipient is responsible for verifying the correctness and completeness of the information issued. This should be done by consulting all relevant documents supplied during the course of the project and by confirming dimensions on site. 9. Updates may not be issued in electronic form. It is the responsibility of the recipient to ensure they have the most up to date information.   10. If altered or added to in any way, all references to J. Duncan must be removed and those making the changes assume total responsibility for the information thereon. The terms “document” & “information” in the above refers to both text documents and drawings in either ‘hard copy’ or electronic format. THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF J. Duncan. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. Title Sheet Project Summary 1. Floorplan 2. Foundation Plan 3. Exterior Elevations 4. Roofing Plan 5. Door/Window Schedule 6. Perspective Renders 7.1504 Hanger StPRINTING TO SCALE: THIS PLAN SET CAN BE PRINTED TO SCALE BY ANY LOCAL PRINTING SHOP, AS LONG AS THE FOLLOWING SPECIFICATION IS MADE: PLAN MUST BE PRINTED AT ACTUAL SIZE IN ORDER TO SCALE PROPERLY. ENSURE THAT PRINT SHOP DOES NOT UTILIZE "FIT TO SHEET" OPTION WHEN PRINTING OR SCALE WILL BE INCORRECT. P-1SHEET:P-1Orndorff Construction WH WH 2840SH2840SH2840SH306830682840SH2840SH2840SH 2068 5068 2850SH2660SH2660SH28682868286828682668 2668 2660SH2660SH2850SH5068 5068 5068 2068 S1 2 S1 2 CROSS SECTION 1 1'-0 1/2"2'-6"6'-9 1/2"6'-10 1/2"2'-6"11 1/2"8"2'-8"11'-8"16'17'-1 1/2" 1'-6"1'-6" 3'-6 1/4"3'-6 1/4" 1'-6" 1'-6" 1'-10" 2'-8" 3" 2'-8" 3" 2'-8" 1'-6" 3' 1'-6 1/2" 2'-7"3' 1'-6" 2'-8" 3" 2'-8" 3" 2'-8" 1'-10" 16'-4 1/2"17'-5" 33'-9 1/2"6'-9 1/2"2'-6"1'-0 1/2"3'-4"10'-4"3'10'-4"15'5'-10 1/2"47'-10 1/2"5'-10 1/2"11'-11"2'-8"5"1'-0 1/2"2'-6"6'-9 1/2"5'-10 1/2"15'10'-4"3'10'-4"3'-4"47'-10 1/2"5'-10 1/2"3'-1 1/2"8'6'-5 1/2"5'-6 1/2"7'-10"2'-10" 33'-9 1/2" 5'-6" X 11'-2" 1419 SQ FT 10'-0" X 10'-0" 10'-0" X 10'-0"5'-8" X 15'-0"16'-0" X 14'-8" 6'-10" X 2'-8" 10'-0" X 10'-0" 15'-11" X 6'-0"15'-11" X 6'-0" 16'-0" X 14'-8" 7'-6" X 2'-8"5'-8" X 15'-0"5'-6" X 11'-2"10'-0" X 10'-0" 6'-10" X 2'-8" 7'-6" X 2'-8" LIVING AREA PATIO DSH WSHR LAUNDRY CENTER LIVING BEDROOM 2 BEDROOM 1 CLOSET BATHKITCHENPATIO CLOSET DSH WSHR LAUNDRY CENTER CLOSET BEDROOM 1 BATH KITCHENCLOSET BEDROOM 2 LIVING SSSSS1 2 S1 2 CROSS SECTION 1 33'-9 1/2" 33'-9 1/2" 33'-9 1/2" 33'-9 1/2"42'6'-0 1/4"48'-0 1/4"42'32'-6" X 5'-4" PATIO Cross Section 1 DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:7/15/20251504 Hanger StAREAS HEATED/COOLED FRONT PORCH TOTAL FOUNDATION 1,419 / 709.5 205 / 105 1,624 SQ FT 1st Floor Plan 1/4" = 1' Floor Plan Notes 1.ALL EXTERIOR DIMENSIONS ARE TO THE MAIN LAYER. DIMENSIONS TO OPENINGS ARE TO THE FRAMING, ROUGH OPENING. INTERIOR DIMENSIONS ARE TO THE FINISHED WALL. 2.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). 3.GROUND SHOULD BE CHEMICALLY TREATED FOR TERMITE PROTECTION Floor / Foundation PlanSHEET:P-2Orndorff ConstructionF ire Wall Specification 1/4" = 1' 2 layers 5/8" Type X 1 Hour Gypsum Board 2x4 Wood Studs, Batt Insulation 5/8" Type X Gypsum Board 2 layers 5/8" Type X 1 Hour Gypsum Board 2x4 Wood Studs, Batt Insulation 5/8" Type X Gypsum Board Foundation Plan SLAB WI TH FOOTERS 1/4" = 1' FOUNDATION NOTES 1.FOUNDATIONS TO BEAR A MINIMUM OF 16” BELOW FINISH GRADE 2.ALL ANCHOR BOLTS TO BE 5/8” DIA X 10 @ 32” O/C UNO. 3.ALL REINFORCING STEEL SHALL BE ASTM A-615, GRADE 60. 4.ALL REINFORCING STEEL TO OVERLAP A MINIMUM OF 24” FOR SPLICES. 5.PROVIDE CORNER BARS TO MATCH CONTINUOUS STEEL. 6.MINIMUM ALLOWABLE CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI AT 26 DAYS. MAXIMUM AGGREGATE SIZE IS 1”. MAXIMUM AIR ENTRAINMENT IS 3%. CEMENT SHOULD BE TYPE 1 OR 2. 7.SOIL BEARING CAPACITY ASSUMED TO BE 1500 PSF (UBC TYPE 4 SOIL). IF SOIL CONDITIONS VARY FROM THIS, THE PROJECT ENGINEER MUST BE NOTIFIED. ALL FOOTINGS MUST BEAR ON UNDISTURBED SOIL. ALL SLOPES MUST BE STABILIZED. 8.ADJACENT GROUND SURFACES SHALL BE SLOPED AWAY FROM STRUCTURE DRAINAGE OF SURROUNDING AREA SHALL ALSO BE PROVIDED TO PREVENT ACCUMULATION OF SOIL AND EROSION OF SOIL NEAR FOOTINGS. 9.UNIFORM SOIL CONDITIONS, MUST BE PROVIDED UNDER SLAB AND FOOTINGS. CUT/FILL OR NON- UNIFORM SOIL CONDITIONS SHOULD BE EXCAVATED AND REPL ACED W/ UNIFORM ENGINEERED FILL MATERIAL TO MINIMIZE DIFFERENTIAL MOVEMENT. 10.THE TOPS OF FOUNDATION WALLS SHALL EXTEND 6” ABOVE THE ADJACENT FINISH GRADE 11.MINIMUM 18” CLEARANCE FOR WOOD JOIST GIRDERS REQUIRED IN THE CRAWL SPACE UNLESS TREATED WOOD IS USED THROUGHOUT FLOOR SYSTEM   MASONRY NOTES 1.ALL CONCRETE MASONRY UNITS TO BE L AID IN CONFORMANCE WITH ASTM C90. 2.CONCRETE MASONRY UNITS TO BE LAID IN TYPE ‘S’ OR TYPE ‘M’ MORTAR IN A RUNNING BOND PATTERN. MORTAR, GROUT AND REINFORCEMENT TO BE IN COMPLIANCE WITH CURRENT CODES. 3.COMPRESSIVE STRESS OF GROUT TO BE: FM’=2500 PSI. ALL CELLS TO BE FULLY GROUTED. 4.ALL REINFORCING STEEL TO BE: ASTM-A-615, GRADE 60.   Typical Slab Section FIRE WALL TO CONTINUE THROUGH ATTIC TO ROOF SHEATHING, INCLUDING PORCH 8 : 128 : 12 33'-9 1/2"47'-10 1/2"33'-9 1/2" 3068 3068 2840SH 2840SH2840SH 2840SH2840SH2840SH 2'-8"3'4'-7 3/4"2'-8" 3" 2'-8" 1'-8 1/4" 17'-7"8"6'7'-4 1/2"2'-4 3/4"8'-8 1/2"3'-4 3/4"BOTTOM OF FOOTING -0.7' TOP OF PLATE 9.1'9'-9 1/4"TOP OF PLATE 17.8'8'-8 1/2"HIGHEST RIDGE 21.2'3'-4 3/4"2'-8" 3"6" 2'-2" 3" 2'-7" 1" 1' 6" 3' 6" 3'-1 1/2" 6" 3' 6" 1' 1" 2'-7" 3" 2'-2" 6"3" 2'-8"1"2'-7"4'2'-4 1/2"7 3/4"3'-10"2'-2"8'-11 1/2"2'-8"3'4'-7 3/4"2'-8" 3" 2'-8" 1'-8 1/4" 17'-7"8"6'7'-4 1/2"2'-4 3/4"8'-8 1/2"3'-4 3/4"BOTTOM OF FOOTING -0.7' TOP OF PLATE 9.1'9'-9 1/4"TOP OF PLATE 17.8'8'-8 1/2"HIGHEST RIDGE 21.2'3'-4 3/4"2'-8" 3"6" 2'-2" 3" 2'-7" 1" 1' 6" 3' 6" 3'-1 1/2" 6" 3' 6" 1' 1" 2'-7" 3" 2'-2" 6"3" 2'-8"1"2'-7"4'2'-4 1/2"7 3/4"3'-10"2'-2"8'-11 1/2"3068 3068 2840SH 2840SH2840SH 2840SH2840SH2840SH 2660SH2660SH2850SH 11'-9 1/2"2'-8" 1'-5 1/2" 2'-6"10'-10"2'-6"7"6'2'-4 1/2"8'-11 1/2"6'-1"10'-1" 45' 11'-9 1/2"2'-8" 1'-5 1/2" 2'-6"10'-10"2'-6"7"6'2'-4 1/2"8'-11 1/2"6'-1"10'-1" 45' 2660SH2660SH2850SH 33'-9"33'-9" 2660SH2660SH 2850SH 2'-8"12'-8 1/2"2'-8"8'-5"2'-8"14'-11 3/4" 2'-7 1/2" 2'-7 1/2"1'-7"5'2'-8"12'-8 1/2"2'-8"8'-5"2'-8"14'-11 3/4" 2'-7 1/2" 2'-7 1/2"1'-7"5'2660SH2660SH 2850SH DRAWINGS PROVIDED BY:J. Duncanjduncan@renovatio.life(501) 749-3936DATE:7/15/2025Roof / Exterior ElevationsFront Elevation For illustration only No Scale Right Elevation For illustration only No Scale 1504 Hanger StRear Elevation For illustration only No Scale Left Elevation For illustration only No Scale SHEET:P-3Orndorff ConstructionROOF FRAMING NOTES: HAND FRAME TIMBER FRAMING FOR ROOF 1.ALL JOISTS/TRUSSES SHALL BE INSTALLED & BRACED TO LOCAL CODE REQUIREMENTS. 2.ROOF TO BE SHINGLED IN 30 YEAR 3 TAB OR ARCHITECTURAL ASPHALT SHINGLE. 3.ALL ROOF FRAMING 24" O.C. UNO 4.ALL OVERHANGS 18" UNO. 5.RECOMMEND INSTALLATION OF OPEN CELL FOAM INSULATION UNDER ROOF SHEATHING AND EXTERIOR ATTIC WALLS. 6. ATTIC VENTILATION/CONDITIONING TO MEET LOCAL CODE REQUIREMENTS.