HomeMy WebLinkAboutPC Minutes 082125August 14, 2025
1
ITEM NO.: 16 FILE NO.: Z-10173
NAME: Mays/Harris – PD-R
LOCATION: 3201 W. 12th Street
OWNER/AUTHORIZED AGENT:
Larry Harris, Jr. (Agent)
2109 Red River Road
Forney, TX 75126
(501) 231-2270
Jimmy Mays (Owner)
ENGINEER/SURVEYOR:
Brooks Surveying, Inc.
20820 Arch Street Pike
Hensley, AR 72065
AREA: .31 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 1 PLANNING DISTRICT: 9 CENSUS TRACT: 13
CURRENT ZONING:
VARIANCE/WAIVERS:
R-3
None requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to rezone .31-acre from R-3 to PD-R, to develop a
four (4) unit multi-family housing complex. The property owner will occupy
one (1) of the units, with the remaining three (3) single-family units being
rented. The lot is located at 3201 W. 12th Street located in the predominant
Single-Family District north of Asher Avenue and east of University Avenue.
B. EXISTING CONDITIONS:
The property is located in an R-3 zoning and sits on the corner of W. 12th
Street and Allis Street. The lot is currently vacant and grass covered. The two
adjacent lots to the West are vacant and grass covered. Across W. 12th
August 14, 2025
2
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
Street’s corridor going North a single-family home resides. Future Land Use for the
property is Mixed Use as well as to the East and West of the property and the other
side of W. 12 Street’s corridor going East and West. South of the property is
Residential Low Density (RL).
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS (PLANNING):
1. Drives may not exceed 40% of the lot width.
2. Contact Planning and Development Dept., Engineering Division at 501-371-4817
or at 501-918-5348 for inspections of any work in the public right-of-way prior to
placement of concrete or asphalt or for on-site clarification of requirements prior to
commencing work. Failure to do so can result in removal of any improperly placed
concrete or asphalt at the expense of the owner or contractor.
3. Hauling of cut and/or fill material on or off project sites over municipal streets
require approval prior to a grading permit being issued. Contact Public Works
Traffic Engineering at 621 S. Broadway 501-379-1800 with any questions or for
more information.
4. Damage to public and private property due to hauling operations or operations of
construction related equipment from a construction site shall be repaired by the
responsible party prior to the issuance of a certificate of occupancy.
ENGINEERING (PUBLIC WORKS):
1. No Comments
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
AT & T: No comments received.
Central Arkansas Water: - NO OBJECTIONS; All Central Arkansas Water
requirements in effect at the time of request for water service must be met
Fire Department: No Comment
August 14, 2025
3
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
Parks and Recreation: No comments received.
County Planning: No Comments received.
F. BUILDING CODES/LANDSCAPE:
Building Code:
Townhouse Construction Requirements for the City of Little Rock, Arkansas
1. Framing Requirements:
a. All Townhomes shall be constructed with 2-Hour Fire Barrier Wall extending
through the roof and exterior walls or from the slab to the roof deck and front
walls with a 1-Hour extension on both sides of the wall for 48” on the walls and
48” on the roof structure.
i.Doors must be fire rated if they are installed in wall.
ii.Overhead doors are not allowed to be installed in the fire rated wall
section listed above.
b. 2-Hour Fire Barrier Walls shall be independently constructed from all roof
and floor loads and must remain standing throughout a fire event. No framing
members are allowed to pass through the fire wall.
c. No power, gas, sewer, water, phone, security wiring, is allowed to be
installed in the 2-Hour fire barrier walls. No exceptions.
d. 2-Hour wall must extend out into the soffit to the back of the sub-fascia and
down to the bottom of the soffit.
e. Soffit Vents must be broken 48” from each side of the 2-hour fire barrier
wall.
f. Ridge Vents must be broken 48” from each side of the 2-hour fire barrier
wall.
2. Utilities:
a. Electrical
i.Separate Electrical Services are required. Each unit must have its
own separate electric meter and disconnecting means on the outside
of the unit.
August 14, 2025
4
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
ii.No electrical allowed in 2-hour fire barrier walls.
b. Water
i. A single water meter is allowed but water must enter each unit from
the outside with a water box / valve / union assembly before entering
the unit.
ii.Each unit requires its own water heater.
c. Sanitary Sewer
i.A single sanitary sewer service is allowed in units that are leased to
the occupants.
ii.Each unit individually owned must have its own sanitary sewer
service.
iii.Each unit individually owned where the yard is also owned must have
its own individual sanitary service on the property under ownership.
iv.Cleanouts required at the entry and exit from the building.
d. Natural Gas
i.A single natural gas meter is allowed in buildings that are leased to the
occupants or units where the building unit is owned but not the yard.
ii.Gas Service must enter each unit from the outside and have a shutoff
on the outside of each unit.
iii. Each unit individually owned where the yard is also owned must have
its own natural gas service meter and service. Services must be
contained within each individual yard.
e. HVAC
i.All units must have their own designated HVAC System. No sharing
within the overall building or yard area.
NOTE: A site utility plan is required for all townhouse construction.
August 14, 2025
5
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
NOTE: Townhouse construction requires separately derived utility services for
Electrical, Water, Sanitary Sewer, Natural Gas and HVAC with all systems contained in
front / back yard building lines extending to a shared utility easement.
NOTE: If Townhouse Units cannot comply with utility requirements they are classified
as condominiums and are required to have fire sprinkler installations throughout and
are allowed to be separated by 1-hour fire walls.
walls.
Landscape: No Comments
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
August 14, 2025
6
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
Land Use Plan:
The request is in the I-630 Planning District, District 9. The development principles of
the district include: preserving the residential character of the area and isolate non-
residential uses to specific locations without affecting the adjacent neighborhoods;
encourage architectural compatibility for new construction; improve street and
drainage facilities; and improve pedestrian facilities. The Land Use Plan shows Mixed
Use (MX) for the requested area. The Mixed Use (MX) category provides for a mixture
August 14, 2025
7
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
of residential, office and commercial uses to occur. A Planned Zoning District is
required if the use is entirely office or commercial or if the use is a mixture of the three.
The application is for a Planned Development-Residential (PD-R).
To the east and west of the application along the W 12th St corridor is designated for
Mixed Use (MX) uses and is characterized by single-family homes, small apartment
developments (3-6 units) and two faith-based institutions. South of the application
area for Residential Low (RL) use which is characterized by single-family homes with
scattered duplexes and small apartment developments (3-6 units).
This site is not located in an Overlay District.
Master Street Plan:
W. 12th Street is a Minor Arterial on the Master Street Plan. Minor Arterials are high
volume roads designed to provide the connections to and through an urban area. Curb
cuts should be minimized to allow for continuous traffic flow while still allowing some
access to adjoining property. Deceleration Lanes are required. Standard Right-of-way
(ROW) is 90 feet. Sidewalks are required on both sides. This street may require
dedication of right-of-way and may require street improvements.
August 14, 2025
8
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
August 14, 2025
9
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
Bicycle Plan:
W 12th Street is on the Master Bike Plan as an Existing Class II Bike Lane. Class
II Bike Lanes provide a portion of the pavement for the sole use of bicycles.
Historic Preservation Plan:
The application, as shown, should have no effect on identified historic resources.
H. ANALYSIS:
The applicant proposes to rezone .31-acre from R-3 to PD-R, to develop a four (4)
unit multi-family housing complex. The property owner will occupy one (1) of the
units, with the remaining three (3) single-family units being rented. The lot is
located at 3201 W. 12th Street located in the predominant Single-Family District
north of Asher Avenue and east of University Avenue.
The property is located in an R-3 zoning and sits on the corner of W 12th Street and
Allis Street. The lot is currently vacant and grass covered. The two adjacent lots to
the West are vacant and grass covered. Across the W. 12th Street corridor going
North a single-family home resides. Future Land Use for the property is Mixed Use
as well as to the East and West of the property and the other side of W. 12 Street’s
corridor going East and West. South of the property is Residential Low Density
(RL).
The proposed two-story multi-family complex will be 88’ x 40’ in area (3,520 square
feet) and be composed of metal exterior siding. The height will be 25.10 feet. Soffit
lighting will be utilized. Height and lighting are in compliance with the City
Ordinance Code.
The two lots will be replatted into one lot, prior to application for a building permit.
The structure will be located 20 feet back from the West (side) property line, 40
feet back from the East (side) property line. The North and South building setbacks
will be 22.24 from the property line. On the southern perimeter of the property there
will be a wall separating the property from the alley.
There is a 15-foot-wide one-way access entering and exiting the property from Allis
Street (circular driveway), with the flow of traffic entering closest to the southern
property line. Each unit has a one-car garage, with one (1) extra parking space for
each unit, providing two (2) spaces per unit.
August 14, 2025
10
ITEM NO.: 16 (Cont.) FILE NO.: Z-10173
Staff is supportive of the requested rezoning. Staff feels the request is
reasonable. Staff feels that the applicant is proposing a quality plan for the
development of this site. Properties in the general area contain a mixture of zoning
and uses including residential low and mixed urban use. The proposed four-plex
residential development will serve as a good transitional use between W. 12th
Street, a minor arterial roadway, and the residential properties to the south. Staff
feels that the development of this property will have no adverse effect on the
surrounding properties in the general area
I. STAFF RECOMMENDATION:
Staff recommends approval of the Conditional Use Permit subject to compliance
with the comments and conditions noted in paragraphs D, E, and F and the staff
analysis of the agenda staff report.
PLANNING COMMISSION ACTION: (AUGUST 14, 2025)
The applicant was present. There were no persons registered in opposition. Staff
presented the item, and a recommendation of approval as outlined in the “staff
analysis” above. The item remained on the Consent Agenda for Approval. The vote
was (11) ayes, (0) nays and (0) absent. The motion passed. The application was
approved.