HomeMy WebLinkAboutS-867-R(10) Staff Report 082625September 11, 2025
ITEM NO.: 3 FILE NO.: S-867-R(10)
NAME: Chenal Valley Phase 37 – Preliminary Plat
LOCATION: North side of Chenal Valley Drive at Orle Boulevard
DEVELOPER:
Potlatch – Deltic Real Estate, LLC
7 Chenal Club Boulevard
Little Rock, AR 72223
OWNER/AUTHORIZED AGENT:
White-Daters & Associates (Agent)
24 Rahling Circle
Little Rock, AR 72223
SURVEYOR/ENGINEER:
White-Daters & Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 31 acres NUMBER OF LOTS: 30 FT. NEW STREET: 2,100 LF
WARD: 5 PLANNING DISTRICT: 19 CENSUS TRACT: 42.13
CURRENT ZONING: R-2
Background:
The subject property contains approximately thirty (30) acres in area and is
currently unplatted. Several subdivisions, Miramar, Orle, Solonge, Germany Court
and Deauville, are located in the general area to the south of the subject property
along Chenal Valley Drive. Bear Dean Estates Subdivision is the most recent
subdivision developed in the area to the north side of Chenal Valley Drive and will
abut proposed subdivision, Chenal Valley, Phase 37 to the east.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
2
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to subdivide the subject property into thirty (30) lots for
single-family residential development. The proposed development will include
private streets. All of the lots contain 25-foot front platted building setback lines.
The property will be developed in two (2) phases.
B. EXISTING CONDITIONS:
The property is currently undeveloped and mostly wooded. The property generally
slopes downward from east to west.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property abutting the site and all neighborhood associates registered
with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS (PLANNING):
1. Drives may not exceed 40% of the lot width.
2. Provide a vehicle tracking diagram for a fire ladder truck and ensure they can
make the circles for fire apparatus.
3. City of Little Rock Residential Road Standard is min. 50 ft ROW, plans show
only 45 ft.
4. Subdivision must provide sidewalk per City Standard.
5. Boundary street requirements for Carter Lane shall be done in accordance
with city Residential Street Standards.
6. How are you going to detain in line?
7. The drainage on the east, how are you going to maintain the private
responsibility of not forcing that onto your neighbors? Swale?
8. Provide Finished Floor Elevations for all lots near the creek, also show the
possible extents of flooding with the show Q of 740CFS.
9. Contact Planning and Development Dept., Engineering Division at 501-371-
4817 or at 501-918-5348 for inspections of any work in the public right-of-way
prior to placement of concrete or asphalt or for on-site clarification of
requirements prior to commencing work. Failure to do so can result in removal
of any improperly placed concrete or asphalt at the expense of the owner or
contractor.
10. Hauling of cut and/or fill material on or off project sites over municipal streets
require approval prior to a grading permit being issued. Contact Public Works
Traffic Engineering at 621 S. Broadway 501-379-1800 with any questions or
for more information.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
3
11. Damage to public and private property due to hauling operations or operations
of construction related equipment from a construction site shall be repaired by
the responsible party prior to the issuance of a certificate of occupancy.
12. Arkansas Fire Prevention Code 2021 Volume 3 Residential Chapter 4
Foundations Section R401.3 Drainage. Surface drainage shall be diverted to
a storm sewer conveyance or other approved point of collection that does not
create a hazard. Lots shall be graded to drain surface water away from
foundation walls. The grade shall fall a minimum of 6 inches (152mm) within
the first 10 feet (3048mm). Exception: Where lot lines, walls, slopes or other
physical barriers prohibit 6 inches (152mm) of fall within 10 feet (3048mm),
drains or swales shall be constructed to ensure drainage away from the
structure. Impervious surfaces within 10 feet (3048mm) of the building
foundation shall be sloped a minimum of 2 percent away from the building.
ENGINEERING COMMENTS (PUBLIC WORKS):
1. Confirm Devon Court is proposed to be a private street.
2. Provide the proposed centerline street slopes. Portions of the street appear to
exceed 30% with existing contours. Per the MSP, minor residential streets can
be constructed to a 16% and 18% with approval. The turning movements on
steep slopes for collection trucks and fire trucks must be taken into account at
the west Cul de sac.
3. Show the proposed location of the USPS cluster box in conformance with USPS
cluster box in conformance with USPS and City of Little Rock policy design
standards.
4. In accordance with Section 32-8, no obstruction to visibility shall be located
within a triangular area 50' back from the intersecting right-of-way line (or
intersecting tangent lines for radial dedications) at the intersection of Devon
Court with Chenal Valley Drive. Provide a letter prepared by a registered
engineer certifying the intersection sight distance at the Devon Ct & Chenal
Valley Drive intersection(s) comply with 2004 AASHTO Green Book standards.
5. Show the proposed access roads for future detention pond maintenance.
Access to detention ponds must be provided to the public right-of-way and/or
access easement for future maintenance by the developer and/or local property
owners’ association.
6. No residential waste collection service will be provided on private streets unless
the property owners association provides a waiver of damage claims for
operations on private property.
7. 100 year overflow swales must be constructed and placed within drainage
easements or tracts to prevent fencing and other obstructions.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
4
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority:
1. Please submit plans for sewer main extension.
Entergy: No comments received.
Summit Utilities: No comments received.
AT & T: No comments received.
Central Arkansas Water:
1. Provide a 10’ utility easement along Devon Court on either side.
2. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
3. Please submit plans for water facilities to Central Arkansas Water for review.
Plan revisions may be required after additional review. Contact Central
Arkansas Water regarding procedures for installation of water facilities.
Approval of plans by Central Arkansas Water, the Arkansas Department of
Health Engineering Division and Little Rock Fire Department is required.
4. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
5. A Capital Investment Charge based on the size of meter connection(s) will
apply to this project in addition to normal charges.
Fire Department:
All projects submitted for zoning approval must comply with the Arkansas
Fire Prevention Code, 2021 Edition, including any comments or
requirements provided by the Little Rock Fire Marshal's Office, prior to
acceptance.
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
5
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied, and the applicant
must submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with asphalt, concrete or other approved driving surface capable of
supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by
one person.
4. Gate components shall be maintained in an operable condition at all times
and replace or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
a. Manual opening gates shall not be locked with a padlock or chain and
padlock unless they are capable of being opened by means of forcible entry
tools or when a key box containing the keys to the lock is installed at the
gate location.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
6
b. Locking device specifications shall be submitted for approval \by the fire
code official
c. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
d. Gates, intended for automatic operation, shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two-Family dwelling residential developments. ATTENTION:
Developments of one- or two-family dwellings where the number of dwelling
units exceeds 30 shall be provided with two separate and approved fire
apparatus access roads and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and all dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with
future development, as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt.
Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
If you have any additional questions, please contact our office. . Contact Capt. Tony
Rhodes at (501) 918-3757, or Fire Marshal Derek N Ingram (501) 918-3756.
Parks and Recreation: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
Landscape: No comments received.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
7
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
Land Use Plan:
The request is in the Chenal Planning District. The Land Use Plan shows
Residential Low Density (RL) for the requested area. The Residential Low Density
(RL) category provides for single family homes at densities not to exceed 6
dwelling units per acre. Such residential development is typically characterized by
conventional single family homes but may also include patio or garden homes and
cluster homes, provided that the density remains less than 6 units per acre. The
application is for a Preliminary Plat.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
8
The application area is surrounded to the east, north, and west by wooded,
undeveloped land designated for Residential Low (RL) use. South of the
application, across Chenal Valley Drive, is area designated Residential Low (RL)
use which is characterized primarily by single-family homes in subdivisions and
open space related to those subdivisions.
This site is not located in an Overlay District.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
9
Master Street Plan:
Chenal Valley Drive is a Collector on the Master Street Plan. Collectors are
designed to connect traffic from Local Streets to Arterials or to activity centers, with
the secondary function of providing access to adjoining property. The standard
Right of way is 60’. Sidewalks are required on one side of Collectors. This street
may require dedication of right-of-way and may require street improvements.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
10
Bicycle Plan:
Chenal Valley Drive is designated on the Master Bike Plan as a existing Class II
Bike Lane. Class II Bike Lanes provides a portion of the pavement for the sole use
of bicycles.
Historic Preservation Plan:
The application, as shown, should have no effect on identified historic resources.
H. ANALYSIS:
The applicant proposes to subdivide the subject property into thirty (30) lots for
single-family residential development. The proposed development will include
private streets. All of the lots contain 25-foot front platted building setback lines.
The property will be developed in two (2) phases.
The property is currently undeveloped and mostly wooded. The property generally
slopes downward from east to west. R-2 zoning and uses are shown in all
directions.
The subdivision will take access from the north side of Chenal Valley Drive from a
ninety (90) foot wide, divided driveway apron that will contain a turnaround.
Ingress/egress will be located in the eastern portion of the tract and will align with
the entry into the Chenal Valley Orle subdivision to the south along Chenal Valley
Drive. The gated entry into the subdivision will contain a guard shack and the mail
kiosk area.
The City’s Master Street Plan shows a future collector street running northwest
from Chenal Valley Drive to Dixie Road, which ties into Ferndale Cut-off. Based on
historic Master Street Plan maps, Staff believes the future collector street is
intended to tie into Chenal Valley Drive west of the proposed subdivision.
The developer proposes to build 2,100 linear feet of streets. All streets and tracts
will be owned and maintained by the Chenal Valley 37 POA.
Lot dimensions are shown as 110’ x 140’ (approximately 15,000 square feet) for
each lot. Lots 1-24 and 30 will be developed during the first phase. Lots 25-29 will
be developed during phase two of the overall development.
A maintenance access road is shown along the north property line in the
northwestern portion of the tract that goes between lots 14-15. The maintenance
road will provide access to the overhead powerlines located to the north of the
development and Devon Court to the south.
September 11, 2025
ITEM NO.: 3 (Cont.) FILE NO.: S-867-R(10)
11
Stormwater detention areas are shown near the northwest corner of the tract and
near the eastern portion of the tract to the north of lots 21-22.
The developer will clear and grade all the lots during the first phase of infrastructure
construction. This will reduce the amount of earthen material to be hauled across
public city streets.
The developer will seek approval from LRWRA Commission regarding the
proposed gravity fed sanitary sewer that will flow into the existing LRWRU lines
following the approval of the preliminary plat.
The applicant is not proposing a sign with this application. All signs must comply
with Section 36-551 (a) (2) of the City of Little Rock code.
The staff’s knowledge there are no outstanding issues associated with the
proposed preliminary plat. The applicant submitted all information requested
during staff’s review of the replat. Staff is supportive of the requested preliminary
plat. The proposed subdivision represents a continuation of the single-family
developments (subdivisions) that are part of Chenal Valley and the Chenal Valley
POA.
STAFF RECOMMENDATION:
Staff recommends approval of the requested preliminary plat, subject to
compliance with the comments and conditions outlined in paragraphs D and E,
and the staff analysis, of the agenda staff report.