Loading...
HomeMy WebLinkAboutZ-6978-A Site Plan A 050825CODE LEGEND 1 HOUR FIRE PARTITION W/ 20 MIN DOORS 1 HOUR FIRE BARRIER W/ 45 MIN. DOORS 2 HOUR FIRE BARRIER W/ 90 MIN DOORS 2 HOUR FIRE WALL W/ 90 MIN DOORS HIGH WIND AREA FIRE EXTINGUISHER: ON BRACKET: MOUNT HANDLE 48" MAX AFF IN CABINET: BOTTOM OF CABINET 32" AFF FIRE DEPARTMENT CONNECTION FIRE ALARM CONTROL PANEL FIRE DEPARTMENT ACCESS (KNOX BOX) /123 345 EXIT COMPONENT ACTUAL OCCUPANT LOAD CAPACITY FDA FACP FDC FE OCCUPANT COUNT @ ROOM EXIT OCCUPANT SUM 123 456 1:20 1:201:20 1:45 1:451:45 2:FB 2:FB2:FB 2:FW 2:FW2:FW 1:20 1:45 2:FB 2:FW 1:20 1:45 2:FB 2:FW 131' - 6" TRAVEL DISTANCE FIRE HYDRANTFH S:0 SMOKE PARTITION: NON-RATED 1S:20 1 HOUR SMOKE BARRIER W/20 MIN DOORS 30:20 30 MINUTE FIRE PARTITION W/ 20 MIN DOORS 1:20 1 HOUR FIRE PARTITION W/20 MIN DOORS 1:FP 1 HOUR FIRE PARTITION W/45 MIN DOORS 1:45 1 HOUR FIRE BARRIER W/45 MIN DOORS 1:60 1 HOUR FIRE BARRIER W/60 MIN DOORS 2:FB 2 HOUR FIRE BARRIER W/90 MIN DOORS 3:FB 3 HOUR FIRE BARRIER W/3 HOUR DOORS 4:FB 4 HOUR FIRE BARRIER W/3 HOUR DOORS 2:FW 2 HOUR FIRE WALL W/90 MIN DOORS 3:FW 3 HOUR FIRE WALL W/3 HOUR DOORS 4:FW 4 HOUR FIRE WALL W/3 HOUR DOORS Business Areas (B) Storage Areas (S-1)FEFDCFDA FE D I A G O N A L = 1 9 0 '1 /3 = 6 3 '-4 " 7,244 SF SHOP 101 1,332 SF WASH BAY 102 304 SF BREAK ROOM 105 960 SF LOBBY 113 349 SF CONFERENCE / TRAINING 112 235 SF SERVICE OFFICE 108 354 SF PARTS ROOM 109 138 SF GENERAL MANAGER 107 59 SF WOMEN'S SINGLE STALL 106 119 SF MEN'S SHOP MULTI-STALL 103 71 SF UTILITY 104 149 SF MEN'S MULTI-STALL 111 63 SF IT CLOSET/ STORAGE 110 5 10 20 400 /16165/16 165 /18410OPEN COVERED BAY 10 17 61'-0"106'-6" 396 SF EQUIPMENT ROOM 102.1 The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 G001 CODE INFORMATIONTier 4Fluid DrLittle Rock, AR 72206EquipmentShareWater Closets Total Facility Fixture Counts Fixture Lavatories Drinking Fountains Service Sinks Male Female Total Total FemaleMale Required Provided Gender Neutral Urinal Substitutions Occupancy Group Assembly / Education All other occupancies Percentage Allowed Required Water Closets Permitted Substitutions Substitutions Applied 67% of required 50% of required 1 1 2 6 5 1 0 1 1 2 4 3 1 0 1 1 1 1 Code BLDG 1 Occupant Load Table Rm No Room Name Function of Space Area (SF)Occupant Load Factor Space Occupant Load 112B CLOSET Business Areas Not Placed 150 SF Not Placed 0 101 SHOP Accessory Storage Areas, Mechanical Equipment Room 7,244 SF 300 SF 25 102 WASH BAY Accessory Storage Areas, Mechanical Equipment Room 1,332 SF 300 SF 5 102.1 EQUIPMENT ROOM Accessory Storage Areas, Mechanical Equipment Room 396 SF 300 SF 2 103 MEN'S SHOP MULTI-STALL Business Areas 119 SF 150 SF 1 104 UTILITY Accessory Storage Areas, Mechanical Equipment Room 71 SF 300 SF 1 105 BREAK ROOM Business Areas 304 SF 150 SF 3 106 WOMEN'S SINGLE STALL Business Areas 59 SF 150 SF 1 107 GENERAL MANAGER Business Areas 138 SF 150 SF 1 108 SERVICE OFFICE Business Areas 235 SF 150 SF 2 109 PARTS ROOM Accessory Storage Areas, Mechanical Equipment Room 354 SF 300 SF 2 110 IT CLOSET/ STORAGE Business Areas 63 SF 150 SF 1 111 MEN'S MULTI-STALL Business Areas 149 SF 150 SF 1 112 CONFERENCE / TRAINING Business Areas 349 SF 150 SF 3 113 LOBBY Business Areas 960 SF 150 SF 7 Level 1 55 Total Building Occupant Load 55 CODE SUMMARY Type of Work New Construction Authority Having Jurisdiction Little Rock Planning and Development 723 West Markham Street Little Rock, AR 77201 Anticipated Occupancy May 2025 Adopted Codes & Ordinances 2021 AR Fire Prevention Code Vol. 1 2021 AR Fire Prevention Code Vol. 2 2018 Arkansas Plumbing Code 2021 International Mechanical Code 2018 International Fuel Gas Code 2014 Arkansas Energy Code 2020 National Electrical Code ICC/ANSI A117.1 2009 Accessible and Usable Building Facilities Occupancy Classification S-1 & B (non-separated) Construction Type V-B Actual Allowable Building Height / Stories 24'-5" / 1 Story 75' / 4 Stories Building Area S-1 Occupancy: 7,938 SF 36,000 SF B Occupancy: 2,537 SF 36,000 SF Sprinkler YES Fire Alarm NO Number of Exits 2 per space greater than 49 (Table 1006.2.1) Common Path of Egress Travel 100' with automatic sprinkler system (Table 1006.2.1) Exit Access Travel Distance 300' with automatic sprinkler system (Table 1017.2) PROJECT INFORMATION BUILDING INFORMATION FIRE SAFETY FEATURES EGRESS COMPONENTS OCCUPANT LOAD TABLE PLUMBING FIXTURE TABLE 3/32" = 1'-0"1 Life Safety Plan