HomeMy WebLinkAboutZ-6978-A Site Plan A 050825CODE LEGEND
1 HOUR FIRE PARTITION W/ 20 MIN DOORS
1 HOUR FIRE BARRIER W/ 45 MIN. DOORS
2 HOUR FIRE BARRIER W/ 90 MIN DOORS
2 HOUR FIRE WALL W/ 90 MIN DOORS
HIGH WIND AREA
FIRE EXTINGUISHER:
ON BRACKET: MOUNT HANDLE 48" MAX AFF
IN CABINET: BOTTOM OF CABINET 32" AFF
FIRE DEPARTMENT CONNECTION
FIRE ALARM CONTROL PANEL
FIRE DEPARTMENT ACCESS (KNOX BOX)
/123 345
EXIT COMPONENT
ACTUAL OCCUPANT LOAD
CAPACITY
FDA
FACP
FDC
FE
OCCUPANT COUNT @ ROOM EXIT
OCCUPANT SUM
123
456
1:20 1:201:20
1:45 1:451:45
2:FB 2:FB2:FB
2:FW 2:FW2:FW
1:20
1:45
2:FB
2:FW
1:20
1:45
2:FB
2:FW
131' - 6"
TRAVEL DISTANCE
FIRE HYDRANTFH
S:0 SMOKE PARTITION: NON-RATED
1S:20 1 HOUR SMOKE BARRIER W/20 MIN DOORS
30:20 30 MINUTE FIRE PARTITION W/ 20 MIN DOORS
1:20 1 HOUR FIRE PARTITION W/20 MIN DOORS
1:FP 1 HOUR FIRE PARTITION W/45 MIN DOORS
1:45 1 HOUR FIRE BARRIER W/45 MIN DOORS
1:60 1 HOUR FIRE BARRIER W/60 MIN DOORS
2:FB 2 HOUR FIRE BARRIER W/90 MIN DOORS
3:FB 3 HOUR FIRE BARRIER W/3 HOUR DOORS
4:FB 4 HOUR FIRE BARRIER W/3 HOUR DOORS
2:FW 2 HOUR FIRE WALL W/90 MIN DOORS
3:FW 3 HOUR FIRE WALL W/3 HOUR DOORS
4:FW 4 HOUR FIRE WALL W/3 HOUR DOORS
Business Areas (B)
Storage Areas (S-1)FEFDCFDA
FE
D I A G O N A L = 1 9 0 '1 /3 = 6 3 '-4 "
7,244 SF
SHOP
101
1,332 SF
WASH BAY
102
304 SF
BREAK ROOM
105
960 SF
LOBBY
113
349 SF
CONFERENCE /
TRAINING
112
235 SF
SERVICE OFFICE
108
354 SF
PARTS ROOM
109
138 SF
GENERAL MANAGER
107
59 SF
WOMEN'S SINGLE
STALL
106
119 SF
MEN'S SHOP
MULTI-STALL
103 71 SF
UTILITY
104
149 SF
MEN'S MULTI-STALL
111
63 SF
IT CLOSET/ STORAGE
110
5 10 20 400
/16165/16 165
/18410OPEN COVERED BAY
10
17
61'-0"106'-6"
396 SF
EQUIPMENT ROOM
102.1
The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet.
All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this
architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents
not exhibiting this seal.
E quipmentShare
5710 Bull Run Rd.
Columbia, MO 65201
ARCHITECT
CONSTRUCTION
CIVIL
STRUCTURAL
MEP
ISSUE VERSION:
1.1 - Little Rock 01/24/2025
G001
CODE INFORMATIONTier 4Fluid DrLittle Rock, AR 72206EquipmentShareWater Closets
Total Facility Fixture Counts
Fixture
Lavatories
Drinking Fountains
Service Sinks
Male Female Total Total FemaleMale
Required Provided
Gender Neutral
Urinal Substitutions
Occupancy Group
Assembly / Education
All other occupancies
Percentage
Allowed
Required
Water Closets
Permitted
Substitutions
Substitutions
Applied
67% of required
50% of required
1 1 2 6 5 1 0
1 1 2 4 3 1 0
1 1
1 1
Code BLDG 1 Occupant Load Table
Rm No Room Name Function of Space Area (SF)Occupant Load Factor Space Occupant Load
112B CLOSET Business Areas Not Placed 150 SF
Not Placed 0
101 SHOP Accessory Storage Areas, Mechanical Equipment Room 7,244 SF 300 SF 25
102 WASH BAY Accessory Storage Areas, Mechanical Equipment Room 1,332 SF 300 SF 5
102.1 EQUIPMENT ROOM Accessory Storage Areas, Mechanical Equipment Room 396 SF 300 SF 2
103 MEN'S SHOP MULTI-STALL Business Areas 119 SF 150 SF 1
104 UTILITY Accessory Storage Areas, Mechanical Equipment Room 71 SF 300 SF 1
105 BREAK ROOM Business Areas 304 SF 150 SF 3
106 WOMEN'S SINGLE STALL Business Areas 59 SF 150 SF 1
107 GENERAL MANAGER Business Areas 138 SF 150 SF 1
108 SERVICE OFFICE Business Areas 235 SF 150 SF 2
109 PARTS ROOM Accessory Storage Areas, Mechanical Equipment Room 354 SF 300 SF 2
110 IT CLOSET/ STORAGE Business Areas 63 SF 150 SF 1
111 MEN'S MULTI-STALL Business Areas 149 SF 150 SF 1
112 CONFERENCE / TRAINING Business Areas 349 SF 150 SF 3
113 LOBBY Business Areas 960 SF 150 SF 7
Level 1 55
Total Building Occupant Load 55
CODE SUMMARY
Type of Work New Construction
Authority Having Jurisdiction Little Rock
Planning and Development
723 West Markham Street
Little Rock, AR 77201
Anticipated Occupancy May 2025
Adopted Codes & Ordinances 2021 AR Fire Prevention Code Vol. 1
2021 AR Fire Prevention Code Vol. 2
2018 Arkansas Plumbing Code
2021 International Mechanical Code
2018 International Fuel Gas Code
2014 Arkansas Energy Code
2020 National Electrical Code
ICC/ANSI A117.1 2009 Accessible and Usable Building Facilities
Occupancy Classification S-1 & B (non-separated)
Construction Type V-B
Actual Allowable
Building Height / Stories 24'-5" / 1 Story 75' / 4 Stories
Building Area S-1 Occupancy:
7,938 SF 36,000 SF
B Occupancy:
2,537 SF 36,000 SF
Sprinkler YES
Fire Alarm NO
Number of Exits 2 per space greater than 49 (Table 1006.2.1)
Common Path of Egress Travel 100' with automatic sprinkler system (Table 1006.2.1)
Exit Access Travel Distance 300' with automatic sprinkler system (Table 1017.2)
PROJECT INFORMATION
BUILDING INFORMATION
FIRE SAFETY FEATURES
EGRESS COMPONENTS
OCCUPANT LOAD TABLE
PLUMBING FIXTURE TABLE
3/32" = 1'-0"1 Life Safety Plan