Loading...
HomeMy WebLinkAboutZ-6978-A Fluid Drive Plans 050825The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 G000 COVER SHEETTier 4Fluid DrLittle Rock, AR 72206EquipmentShareRetail Tier 4 Equipment Share Fluid Dr Little Rock, AR 72206 Bid Package GENERAL G000 COVER SHEET G001 CODE INFORMATION G002 SPECIFICATIONS G003 SPECIFICATIONS CIVIL CE 1.1 SITE PLAN (TWO ENTIRES) CE 1.2 SITE PLAN (ONE ENTRY) CE 2.1 CONSTRUCTION DETAILS ARCHITECTURAL SITE AS101 ARCHITECTURAL SITE PLAN & DETAILS ARCHITECTURE A101 FLOOR PLANS A121 REFLECTED CEILING PLANS A141 ROOF PLAN A201 EXTERIOR ELEVATIONS A301 BUILDING SECTIONS A331 WALL SECTIONS A332 WALL SECTIONS A340 ENLARGED DETAILS A401 ENLARGED PLANS - OFFICE A402 ENLARGED PLANS - WASH BAY A421 INTERIOR FINISH PLANS, ELEV & DETAILS A501 DOOR SCHEDULE & DETAILS A901 FURNITURE & POWER COORDINATION FLOOR PLAN A902 LOW VOLTAGE PLANS STRUCTURAL S100 GENERAL STRUCTURAL DATA S200 FOUNDATION PLAN S210 FOUNDATION DETAILS S211 FOUNDATION DETAILS S300 MEZZANINE PLAN & DETAILS MECHANICAL ME101 MEP SITE PLAN ME102 SITE LIGHTING PLAN MECHANICAL M000 MECHANICAL NOTES, SPECIFICATIONS, AND LEGENDS M101 HVAC PLANS M102 ENLARGED HVAC PLANS M501 MECHANICAL DETAILS M601 MECHANICAL SCHEDULES ELECTRICAL E101 POWER PLANS E102 LIGHTING PLANS E601 ELECTRICAL DETAILS & SCHEDULES PLUMBING P101 SANITARY PLUMBING PLANS P102 DOMESTIC WATER & GAS PLUMBING PLANS P601 PLUMBING SCHEDULES & DETAILS A ACT ADJ AFF ALUM ALT ANOD APPROX ARCH B BLDG BLKG BM BOT BRG BRKT BTM BSMT BTWN C CAB CC CEM CG CJ CLG CLR CM CMU COL CONC CONST CONT CTR CY D DF DIA DIM DN DS DTL DWG E E EA EF EIFS EJ ELEC ELEV EQ EQUIP ETR EW EXIST EXP EXT F FA FD FND FE FEC FF FH FIN FIXT FLR FLEX FOM FOPC FOS FOW FT (') FTG FV G GA GALV GC GEN GL GR GYP GYP BD H handicapped head hardwood hardware hollow metal horizontal hour height heating, ventilation & air conditioning I ID IN (") INDIV INFO INSUL INT J JST JT K kitchen MAS MATL MAX MB MECH MEP MFR MIN MISC MO MTD MTG HT MTL MULL N N NIC NO (#) NOM NRC NTS O OC OD OFCI OFOI OTS OPNG OPP P PAR PCP PERP PL PLBG PLYWD PNL PR PREFAB PTD PVC R RAD RD RE: REINF REV REQ'D RFG S S SCHED SECT SF SHT SHWR SIM SPEC SQ SSTL STC STD STL STRUCT SUSP SY SYM T T&B T&G TO TOC TOM TOS TOW TS TYP U UNO V VERT VTR W west wood window with without Y YD SYMBOLS / & @ [ ℄ Ø ± acoustical adjustable/adjacent above finish floor aluminum alternate anodized approximate(ly) architect(ural) building blocking beam bottom of bearing bracket bottom basement between cabinet center to center cement(itious) corner guard control joint ceiling clear(ance) contruction manager concrete masonry unit column concrete construction continuous center cubic yard(s) drinking fountain diameter dimension(s) down downspout detail drawing east each each face exterior insulation finish system expansion joint electrical elevation equal equipment existing to remain each way existing expansion exterior fire alarm floor drain foundation fire extinguisher fire extinguisher cabinet finish floor fire hose finish(ed) fixture floor flexible face of masonry face of precast face of stud face of wall foot footing field verify gauge galvanized general contractor general glass grade gypsum gypsum board HC HD HDWD HDWR HM HORIZ HR HT HVAC inside diameter inch(es) individual information insulation interior joist joint KIT masonry material maximum markerboard mechanical mechanical/electrical/plumbing manufacturer minimum miscellaneous masonry opening mounted mounting height metal mullion north not in contract number nominal noise reduction coefficient not to scale on center outside diameter owner furnished, contractor installed owner furnished, owner installed (not in contract) open to structure opening opposite parallel portland cement plaster perpendicular property line plumbing plywood panel pair prefabricated painted polyvinyl chloride radius roof drain refer to reinforcing (ed) reversed required roofing south schedule section square foot sheet shower similar specification square stainless steel sound transmission coeficient standard steel structure(al) suspend(ed) square yard symmetrical top & bottom tongue & groove top of top of curb top of masonry top of slab/steel top of wall tube steel typical unless noted otherwise vertical vent thru roof W WD WDO W/ W/O yard per (or by) and at channel centerline diameter/round plus/minu L LKR LT locker light M ABBREVIATIONSDRAWING INDEX SAND CONTINUOUS LUMBER FINISH LUMBER/ HARDWOOD STEEL OR METAL A101 RM NUMBER Classroom RM NAME A123 DOOR NUMBER WALL TYPE FRAME TYPE GLASS TYPE SECTION CUT LINE ELEVATION SYMBOL ELEV NUMBER SHEET NUMBER ENLARGED DETAIL Joist Bearing 100'-0" A A 1 N1 E1 J1 A1 A10 A500 A9 A120 A601 BLOCKING/SHIM SOIL BRICK (in section) CONCRETE MASONRY UNIT - CMU (in section) CONCRETE (in section) GYP BD (in section) PLYWOOD (in section) RIGID INSUL & EIFS (in section) BATT INSUL (in section) ACOUSTICAL TILE (in section) MATERIAL JOINT BUILDING EXPANSION JOINT DATUM MARKER AREA "B" AREA "A" STUCCO (in section) CODE LEGEND 1 HOUR FIRE PARTITION W/ 20 MIN DOORS 1 HOUR FIRE BARRIER W/ 45 MIN. DOORS 2 HOUR FIRE BARRIER W/ 90 MIN DOORS 2 HOUR FIRE WALL W/ 90 MIN DOORS HIGH WIND AREA FIRE EXTINGUISHER: ON BRACKET: MOUNT HANDLE 48" MAX AFF IN CABINET: BOTTOM OF CABINET 32" AFF FIRE DEPARTMENT CONNECTION FIRE ALARM CONTROL PANEL FIRE DEPARTMENT ACCESS (KNOX BOX) /123 345 EXIT COMPONENT ACTUAL OCCUPANT LOAD CAPACITY FDA FACP FDC FE OCCUPANT COUNT @ ROOM EXIT OCCUPANT SUM 123 456 1:20 1:201:20 1:45 1:451:45 2:FB 2:FB2:FB 2:FW 2:FW2:FW 1:20 1:45 2:FB 2:FW 1:20 1:45 2:FB 2:FW 131' - 6" TRAVEL DISTANCE FIRE HYDRANTFH S:0 SMOKE PARTITION: NON-RATED 1S:20 1 HOUR SMOKE BARRIER W/20 MIN DOORS 30:20 30 MINUTE FIRE PARTITION W/ 20 MIN DOORS 1:20 1 HOUR FIRE PARTITION W/20 MIN DOORS 1:FP 1 HOUR FIRE PARTITION W/45 MIN DOORS 1:45 1 HOUR FIRE BARRIER W/45 MIN DOORS 1:60 1 HOUR FIRE BARRIER W/60 MIN DOORS 2:FB 2 HOUR FIRE BARRIER W/90 MIN DOORS 3:FB 3 HOUR FIRE BARRIER W/3 HOUR DOORS 4:FB 4 HOUR FIRE BARRIER W/3 HOUR DOORS 2:FW 2 HOUR FIRE WALL W/90 MIN DOORS 3:FW 3 HOUR FIRE WALL W/3 HOUR DOORS 4:FW 4 HOUR FIRE WALL W/3 HOUR DOORS Business Areas (B) Storage Areas (S-1)FEFDCFDA FE D I A G O N A L = 1 9 0 '1 /3 = 6 3 '-4 " 7,244 SF SHOP 101 1,332 SF WASH BAY 102 304 SF BREAK ROOM 105 960 SF LOBBY 113 349 SF CONFERENCE / TRAINING 112 235 SF SERVICE OFFICE 108 354 SF PARTS ROOM 109 138 SF GENERAL MANAGER 107 59 SF WOMEN'S SINGLE STALL 106 119 SF MEN'S SHOP MULTI-STALL 103 71 SF UTILITY 104 149 SF MEN'S MULTI-STALL 111 63 SF IT CLOSET/ STORAGE 110 5 10 20 400 /16165/16 165 /18410OPEN COVERED BAY 10 17 61'-0"106'-6" 396 SF EQUIPMENT ROOM 102.1 The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 G001 CODE INFORMATIONTier 4Fluid DrLittle Rock, AR 72206EquipmentShareWater Closets Total Facility Fixture Counts Fixture Lavatories Drinking Fountains Service Sinks Male Female Total Total FemaleMale Required Provided Gender Neutral Urinal Substitutions Occupancy Group Assembly / Education All other occupancies Percentage Allowed Required Water Closets Permitted Substitutions Substitutions Applied 67% of required 50% of required 1 1 2 6 5 1 0 1 1 2 4 3 1 0 1 1 1 1 Code BLDG 1 Occupant Load Table Rm No Room Name Function of Space Area (SF)Occupant Load Factor Space Occupant Load 112B CLOSET Business Areas Not Placed 150 SF Not Placed 0 101 SHOP Accessory Storage Areas, Mechanical Equipment Room 7,244 SF 300 SF 25 102 WASH BAY Accessory Storage Areas, Mechanical Equipment Room 1,332 SF 300 SF 5 102.1 EQUIPMENT ROOM Accessory Storage Areas, Mechanical Equipment Room 396 SF 300 SF 2 103 MEN'S SHOP MULTI-STALL Business Areas 119 SF 150 SF 1 104 UTILITY Accessory Storage Areas, Mechanical Equipment Room 71 SF 300 SF 1 105 BREAK ROOM Business Areas 304 SF 150 SF 3 106 WOMEN'S SINGLE STALL Business Areas 59 SF 150 SF 1 107 GENERAL MANAGER Business Areas 138 SF 150 SF 1 108 SERVICE OFFICE Business Areas 235 SF 150 SF 2 109 PARTS ROOM Accessory Storage Areas, Mechanical Equipment Room 354 SF 300 SF 2 110 IT CLOSET/ STORAGE Business Areas 63 SF 150 SF 1 111 MEN'S MULTI-STALL Business Areas 149 SF 150 SF 1 112 CONFERENCE / TRAINING Business Areas 349 SF 150 SF 3 113 LOBBY Business Areas 960 SF 150 SF 7 Level 1 55 Total Building Occupant Load 55 CODE SUMMARY Type of Work New Construction Authority Having Jurisdiction Little Rock Planning and Development 723 West Markham Street Little Rock, AR 77201 Anticipated Occupancy May 2025 Adopted Codes & Ordinances 2021 AR Fire Prevention Code Vol. 1 2021 AR Fire Prevention Code Vol. 2 2018 Arkansas Plumbing Code 2021 International Mechanical Code 2018 International Fuel Gas Code 2014 Arkansas Energy Code 2020 National Electrical Code ICC/ANSI A117.1 2009 Accessible and Usable Building Facilities Occupancy Classification S-1 & B (non-separated) Construction Type V-B Actual Allowable Building Height / Stories 24'-5" / 1 Story 75' / 4 Stories Building Area S-1 Occupancy: 7,938 SF 36,000 SF B Occupancy: 2,537 SF 36,000 SF Sprinkler YES Fire Alarm NO Number of Exits 2 per space greater than 49 (Table 1006.2.1) Common Path of Egress Travel 100' with automatic sprinkler system (Table 1006.2.1) Exit Access Travel Distance 300' with automatic sprinkler system (Table 1017.2) PROJECT INFORMATION BUILDING INFORMATION FIRE SAFETY FEATURES EGRESS COMPONENTS OCCUPANT LOAD TABLE PLUMBING FIXTURE TABLE 3/32" = 1'-0"1 Life Safety Plan The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 G002 SPECIFICATIONSTier 4Fluid DrLittle Rock, AR 72206EquipmentShare The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 G003 SPECIFICATIONSTier 4Fluid DrLittle Rock, AR 72206EquipmentShare CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet.All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by thisarchitect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documentsnot exhibiting this seal.SHEET KEYNOTE LEGENDREVISIONS:EquipmentShare5710 Bull Run Rd.Columbia, MO 65201ARCHITECTCONSTRUCTIONCIVILSTRUCTURALMEPTier 4 5710 Bull Run Dr. Columbia, MO 65201 EquipmentShare#DescriptionDateTimberlake Engineering912 Old Highway 63 SouthColumbia, MO 65201Phone: 573.875.4365Crockett Engineering Consultants1000 W Nifong Blvd., Bldg. 1Columbia, MO 65203Phone: 573.447.0292Crockett Engineering Consultants1000 W Nifong Blvd., Bldg. 1Columbia, MO 65203Phone: 573.447.0292EquipmentShare5710 Bull Run Rd.Columbia, MO 65201Phone: 573.229.5222CE 1.1SITE PLAN(TWO ENTRIES) CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet.All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by thisarchitect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documentsnot exhibiting this seal.SHEET KEYNOTE LEGENDREVISIONS:EquipmentShare5710 Bull Run Rd.Columbia, MO 65201ARCHITECTCONSTRUCTIONCIVILSTRUCTURALMEPTier 4 5710 Bull Run Dr. Columbia, MO 65201 EquipmentShare#DescriptionDateTimberlake Engineering912 Old Highway 63 SouthColumbia, MO 65201Phone: 573.875.4365Crockett Engineering Consultants1000 W Nifong Blvd., Bldg. 1Columbia, MO 65203Phone: 573.447.0292Crockett Engineering Consultants1000 W Nifong Blvd., Bldg. 1Columbia, MO 65203Phone: 573.447.0292EquipmentShare5710 Bull Run Rd.Columbia, MO 65201Phone: 573.229.5222CE 1.2SITE PLAN(ONE ENTRY) 6" CONCRETE BARRIER CURB CROSS-SECTIONC4 CONCRETE PAVEMENT CROSS-SECTIONC3THICKENED EDGE SIDEWALK WITH INTEGRAL CURB & GUTTERC2SIDEWALK ABUTTING BUILDINGC15" CONCRETE BARRIER CURB CROSS-SECTIONC6(ABUTTING ASPHALT)LIGHT DUTY ASPHALT PAVEMENT CROSS-SECTIONC7TYPE A - EXPANSION JOINTTYPE C - CONTROL JOINT "SAWED"TYPE B - CONSTRUCTION JOINT CONCRETE PAVEMENT JOINT DETAILSC8TYPE A ALTERNATECONCRETE SILLCE 2.1CONSTRUCTION DETAILSLAYDOWN YARD CROSS-SECTIONC5PENALTY$XXXRESERVEDPARKINGADA PARKING AREAC9ADA PARKING SIGNAGEC10PAVEMENT ABUTTING BUILDINGC11CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet.All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by thisarchitect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documentsnot exhibiting this seal.SHEET KEYNOTE LEGENDREVISIONS:EquipmentShare5710 Bull Run Rd.Columbia, MO 65201ARCHITECTCONSTRUCTIONCIVILSTRUCTURALMEPTier 4 5710 Bull Run Dr. Columbia, MO 65201 EquipmentShare#DescriptionDateTimberlake Engineering912 Old Highway 63 SouthColumbia, MO 65201Phone: 573.875.4365Crockett Engineering Consultants1000 W Nifong Blvd., Bldg. 1Columbia, MO 65203Phone: 573.447.0292Crockett Engineering Consultants1000 W Nifong Blvd., Bldg. 1Columbia, MO 65203Phone: 573.447.0292EquipmentShare5710 Bull Run Rd.Columbia, MO 65201Phone: 573.229.5222 Air compressor 6" bollards RE: CIVIL FOR PARKING 13,036 SF ENCLOSED BUILDING FOOTPRINT 1,203 SF COVERED BAYMOTORIZED ROLLING GATESITE CLEARANCE BAR 6" BOLLARDDRIVE AISLE WIDTH PER CIVILPROVIDE VISIBLE KNOX BOX AT EXTERIOR OF FENCE MOTORIZED ROLLING GATE6" BOLLARD SITE CLEARANCE BAR DRIVE AISLE WIDTH PER CIVILCHAIN LINK FENCE W/ (3) STRANDS OF BARBED WIRE SURROUNDING YARD UTILITY METERS, RE: MEP PROPOSED FIRE DEPARTMENT CONNECTION LOCATION CHAIN LINK FENCE W/ (3) STRANDS OF BARBED WIRE SURROUNDING YARD HVAC CONDENSER UNITS AS101 4 4’−0"3’−0"3"6"1’−0"2’−6"1’−6" ROUNDED CONCRETE CROWN PT BENJAMIN MOORE BLACK BEAUTY 2128-10 SEMI GLOSS PT BENJAMIN MOORE DEEP SILVER 2124-30 SEMI GLOSS PT BENJAMIN MOORE BLACK BEAUTY 2128-10 SEMI GLOSS 6" DIAMETER GALVANIZED STEEL PIPE BOLLARD FILLED W/ CONCRETE CORE DRILL - GROUT FILL CONCRETE SLAB CONCRETE FOOTING #4 BAR 12" EACH WAY17’−0"DRIVING SURFACE TO B.O. HUNG BAR14’−0"FOUNDATION PER STRUCT HSS POST PER STRUCT CLEARANCE BAR TYP OF TWO, ONE @ EACH END. MODEL: IBAR-C7120K-604 10' TEXT: Clearance 14' - 00" HSS BEAM PER STRUCT +/− 3’−0" 6' CHAIN LINK FENCE W/ BLACK PRIVACY SLATS 6" BOLLARDS 6' CHAIN LINK GATE W/ BLACK PRIVACY SLATS 10’−3"1’−2" 5’−0" 4’−1" 1’−0" 1’−9" 12’−3" 1’−9" 1’−1 1/2" 10’−0" 1’−1 1/2" 4’−3" 3’−9" 4’−3" The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 AS101 ARCHITECTURAL SITE PLAN & DETAILSTier 4Fluid DrLittle Rock, AR 72206EquipmentShare1" = 10'-0"1 Site Plan 3/4" = 1'-0"2 6" BOLLARD DETAIL 1/4" = 1'-0"3 SITE CLEARANCE BAR 3/8" = 1'-0"4 DUMPSTER ENCLOSURE PLAN SHEET NOTES 1. REFER TO SHEET G000 FOR SHEET INDEX 2. DO NOT SCALE THIS DRAWING 3. ALL INTERIOR WALLS ARE WALL TYPE 13B UNLESS NOTED OTHERWISE. 4. ALL EXTERIOR WALLS ARE BY PEMB SUPPLIER UNLESS NOTED OTHERWISE. 5. INTERIOR DIMENSIONS ARE TO THE FOLLOWING, UNLESS NOTED OTHERWISE: A. TO FACE OF METAL STUD B. TO CENTERLINE OF DOOR AND WINDOW ROUGH OPENINGS 6. EXTERIOR DIMENSIONS ARE TO FACE OF FINISH 7. ALL DOORS TO BE 4" OFFSET FROM OUTSIDE FACE OF WALL, UNO 8. COORDINATE LOCATIONS WHERE BACKING IS REQUIRED FOR WALL HUNG CASEWORK, MARKERBOARDS, WALL HUNG ACCESSORIES AND TECHNOLOGY 9. REFER TO A421 FOR FLOOR FINISHES 10. EXTERIOR WALL FINISH PER WALL TYPES LEGEND AND ELEVATIONS 11. ALL CEILINGS TO BE 1/2" PTD GYP 12. RESTROOM WALLS TO RECEIVE ACOUSTICAL BATTING 13. ALL EQUIPMENT & APPLIANCES TO BE OWNER SUPPLIED, CONTRACTOR INSTALLED UNLESS NOTED OTHERWISE. A201 3 A2012A201 1 1 2 4 2 A301 2 A301 B A 6 7 80 20’−0" 35’−0" 25’−0" 25’−0" 25’−0" 25’−0" 25’−0" 25’−0" 25’−0"60’−0"63 SF IT CLOSET/ STORAGE 110 59 SF WOMEN'S SINGLE STALL 106 119 SF MEN'S SHOP MULTI-STALL 103 149 SF MEN'S MULTI-STALL 111 304 SF BREAK ROOM 105 235 SF SERVICE OFFICE 108 960 SF LOBBY 113 71 SF UTILITY 104 138 SF GENERAL MANAGER 107 354 SF PARTS ROOM 109 7,244 SF SHOP 101 1,332 SF WASH BAY 102 95 349 SF CONFERENCE / TRAINING 1123 1/4"10’−2 3/4"12’−4"18’−8"14’−0"4’−6"101M101L101K101J101H 102C 102A 101E 101D 101C 101B 101A 104A 113A OIL TANKS, RE: PLUMBING 230’−0" 5’−7" 17’−4" 49’−7" 15’−0" 12’−0" 23’−0" 23’−0" 14’−6" 12’−8" 12’−0" 2’−6" 5’−7" 17’−4" 49’−7" 14’−8" 12’−4" 23’−0" 23’−0" 14’−6" C A B C113D 13D C1 16B 396 SF EQUIPMENT ROOM 102.1 102D 102B 102F A401 1 AIR COMPRESSOR 6" BOLLARDS 4’−0" 6’−0" 102E 1/8" / 12"1/8" / 12"WELDER POWER BANK WORKBENCH TRASH SHELVING RACKS 17B 17B 18B DOWNSPOUT 6" BOLLARD DOWNSPOUT 6" BOLLARD 1 A301 1 A301 A402 1 1 A331 101F 3 101G The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A101 FLOOR PLANSTier 4Fluid DrLittle Rock, AR 72206EquipmentShare1/8" = 1'-0"1 Floor Pan PLAN NORTH SHEET NOTES 1. REFER TO SHEET G000 FOR SHEET INDEX 2. REFER TO MEP AND TECHNOLOGY SHEETS FOR SPECIFIC CEILING MOUNTED DEVICES 3. ALL PAINTED GYP BOARD CEILINGS TO BE PT-1 4. ALL EXPOSED METAL STRUCTURE, DECK, HVAC, PIPES, ETC, IN OFFICE AREA TO BE PAINTED 5. ALL REGISTERS, ACCESSORIES, GRILLES, ETC ON DRYWALL CEILINGS TO BE PAINTED TO MATCH CEILING COLOR, UNLESS NOTED OTHERWISE 6. COORDINATE FINAL MOUNTING LOCATIONS OF EXIT SIGNS, STROBES, AND OTHER CEILING MOUNTED FIRE EXIT DEVICES WITH MEP DRAWINGS. 7. REFER TO MECHANICAL DRAWINGS FOR DIFFUSERS, THERMOSTATS, AND OTHER MECHANICAL RELATED EQUIPMENT AND DEVICES 8. ALL CEILINGS TO BE 1/2" GYP 9. ALL CEILINGS IN RESTROOMS TO BE MOISTURE RESISTANT GYP. RE: SPECIFICATIONS. 10. RE:SPECIFICATIONS FOR CEILING TILE INFORMATION. 11. LIGHT FIXTURES TO BE CENTERED AND SPACED EQUIDISTANTLY THROUGHOUT THE SPACE, REFER TO RCPS. 1 2 4 2 A301 2 A301 B A 6 7 80 95 PTD GYP 10'-0" AFF 2x2 ACT 9'-0" AFF 2x2 ACT 9'-0" AFF 2x2 ACT 9'-0" AFF PTD GYP 9'-0" AFF PTD GYP 9'-0" AFF PTD GYP 9'-0" AFF 2x2 ACT 9'-0" AFF OPEN TO STRUCTURE OPEN TO STRUCTURE SOUND ATTENUATION BATT ABOVE RESTROOM CEILINGS, TYP SOUND ATTENUATION BATT ABOVE RESTROOM CEILINGS, TYP GYP HEADWALL TO STRUCTURE ABOVE METAL CANOPY; PEMB MFR. FINISH TO MATCH PT-5 OPEN TO STRUCTURE 14’−0"8’−0"8’−0"14’−0"6’−6" 12’−0" 6’−6" 10’−0" 10’−0" L4 L4 L4 L4 L4 L4 L4 L4 L4 L4 L4 L4 L2 L2 L1 L1 L1 L2 L2 L3 L3 L3 L3 L1 L1 L2 L2 L2 L2 L1 L16’−6"9’−0"6’−8"6’−0"6’−0" 7’−0"7’−0" L5 L5 L5 L5 L5 L5 L5 L5L5 L5 L6 L6 L7 1 2 3 396 SF EQUIPMENT ROOM 102.1 1,332 SF WASH BAY 102 7,244 SF SHOP 101 235 SF SERVICE OFFICE 108 354 SF PARTS ROOM 109 63 SF IT CLOSET/ STORAGE 110 149 SF MEN'S MULTI-STALL 111 349 SF CONFERENCE / TRAINING 112 960 SF LOBBY 113 138 SF GENERAL MANAGER 107 59 SF WOMEN'S SINGLE STALL 106 304 SF BREAK ROOM 105 119 SF MEN'S SHOP MULTI-STALL 103 71 SF UTILITY 104 DOWNSPOUT GUTTER DOWNSPOUT GUTTER 1 A301 1 A301 1 A331 HVLS FAN PER MECH HEATER PER MECH 3 L4 L4 L4 L4 The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. SHEET KEYNOTE LEGEND E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A121 REFLECTED CEILING PLANSTier 4Fluid DrLittle Rock, AR 72206EquipmentShare1/8" = 1'-0"1 Level 1 LIGHT FIXTURE LEGEND L1 6" RECESSED LED CAN LIGHT, WHITE TRIM L2 2x2 LAY-IN LED TROFFER LIGHT L3 DECORATIVE PENDANT LIGHT L4 HIGH-BAY LED LIGHT FIXTURE 8' LED LINEAR WASH BAY LIGHT FIXTUREL5 RE: E601 FOR FIXTURE SELECTIONS 8' LED LINEAR INDOOR LIGHT FIXTUREL6 4' LED LINEAR INDOOR LIGHT FIXTUREL7 1. DASHED LINE INDICATES LOCATION OF STRUCTURAL BEAM TO BE PAINTED PT -5. (MEMBER VISIBLE AT STOREFRONT) 2. FABRIC LINER SYSTEM ON PEMB STRUCTURE, BLACK 3. PAINT VERTICAL FACE OF UPPER LEVEL SOFFIT PT-5. APPLY CUSTOM ES VINYL DECALS AS OUTLINED IN THE DAM. PLAN NORTH EXTERIOR WALL-PACK LIGHTWP SHEET NOTES 1. ROOF TO BE METAL PANEL BY PEMB SUPPLIER, COLOR PER ELEVATIONS 2. ROOF INSULATION TO MEET LOCAL IECC REQUIREMENTS 3. ROOF DRAINAGE / GUTTERS & DOWNSPOUTS BY PEMB SUPPLIER, COLOR TO MATCH ADJOINING WALL A2012A201 1 1 2 4 2 A301 2 A301 B A 6 7 80 95 1" / 12"1" / 12"UNINSULATED OVER OPEN BAY OUTDOORSHOPPREFINISHED 24GA STANDING SEAM METAL ROOF BY PEMB PROVIDER. COORDINATE ANY ROOF PENETRATIONS WITH PEMB SUPPLIER TO ENSURE WARRANTY IS MAINTAINED. COLOR PER ELEVATIONS INSULATION PER LOCAL IECC REQS OVER SHOP PREFINISHED 24GA STANDING SEAM METAL ROOF BY PEMB PROVIDER. COORDINATE ANY ROOF PENETRATIONS WITH PEMB SUPPLIER TO ENSURE WARRANTY IS MAINTAINED. COLOR PER ELEVATIONS INSULATION PER LOCAL IECC REQS OVER OFFICE SHOPOFFICEPREFINISHED METAL GUTTERS BY PEMB SUPPLIER. COLOR TO MATCH ADJOINING SIDING METAL CANOPY, FINISH TO MATCH PT-5 29’−11"30’−1"60’−0"10’−6"12’−4"230’−0" 1 A301 1 A301 1 A331 3 The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A141 ROOF PLANTier 4Fluid DrLittle Rock, AR 72206EquipmentShare1/8" = 1'-0"1 Roof Plan PLAN NORTH SHEET NOTES 1. REFER TO SHEET G000 FOR SHEET INDEX 2. DO NOT SCALE THIS DRAWING 3. WALL MOUNTED LIGHT FIXTURES, LAMBS TONGUES AND OTHER MEP ITEMS ARE SHOWN FOR PLACEMENT ONLY EXTERIOR MATERIAL LEGEND BOD: CLEARSPAN R-PANEL COLOR: WHITE SIZE/ PATTERN: VERTICAL MP1 = METAL PANEL TYPE 1 EXPOSED FASTENER METAL WALL PANELS07 42 13.A01 BOD: CLEARSPAN R-PANEL COLOR: BLACK SIZE/ PATTERN: VERTICAL MP2 = METAL PANEL TYPE 2 EXPOSED FASTENER METAL PLATE WALL PANELS07 42 16.A01 BOD: CLEARSPAN R-PANEL COLOR: BLACK SIZE/ PATTERN: VERTICAL MP3 = METAL PANEL TYPE 3 METAL ROOF PANELS07 41 13.A01 BOD: NITTERHOUSE SPLIT FACE CMU 3-5/8"x8"x16" COLOR: J-12 GRAY SIZE/ PATTERN: RUNNING BOND CMU1 = CONCRETE MASONRY UNITS TYPE 1 BOD: NITTERHOUSE SPLIT FACE CMU 3-5/8"x8"x16" COLOR: NM-216 BLACK SIZE/ PATTERN: RUNNING BOND CMU2 = CONCRETE MASONRY UNITS TYPE 1 DECORATIVE CMU SPLIT FACED04 20 00.A04 DECORATIVE CMU SPLIT FACED04 20 00.A04 Level 1 100'-0" Roof 124'-0" B A CMU2 MP1 ILLUMINATED SIGNAGE 113AA 7’−9"13’−6"EQ EQ 3’−5 1/2"16’−4"C 1 " / 1 2 "1" / 12" SHEET METAL FLASHING, COLOR TO MATCH MP2 SHEET METAL FLASHING, COLOR TO MATCH MP2 CONTINUOUS GUTTER, COLOR TO MATCH MP2 DOWNSPOUT, COLOR TO MATCH MP2 ILLUMINATED SIGNAGE SHEET METAL FLASHING, COLOR TO MATCH MP2 CONTINUOUS GUTTER, COLOR TO MATCH MP2 SHEET METAL END CAP, MATCH MP2 ALUMINUM STOREFRONT SHEET METAL WRAP, PT-5 METAL CANOPY BY PEMB MFR. FINISH TO MATCH PT-5 CMU1 15’−0" 2’−0" 1 A301 Level 1 100'-0" Roof 124'-0" 124 2 A301 678 095 101A 101B 101C 101D 101E 104A B 102D 102F 6" BOLLARD CONCRETE PIER PER STRUCT DOWNSPOUT, COLOR TO MATCH MP2 (TYP) 6" BOLLARD ALUMINUM STOREFRONT DOWNSPOUT, COLOR TO MATCH MP2 (TYP) 6" BOLLARDCHAIN LINK FENCE W/ (3) STRANDS OF BARBED WIRE SURROUNDING YARD CONTINUOUS GUTTER, COLOR TO MATCH MP2 METAL CANOPY BY PEMB MFR. FINISH TO MATCH PT-5 ILLUMINATED SIGNAGE LOUVER PER MECH MP3MP3 MP2 MP1 MP2 MP2 MP2 MP2 MP1MP1MP1 1 A331 WP WP WP WP WP VENTILATION LOUVRES PER MECH UTILITY BOXES PER MEP 3 Level 1 100'-0" Roof 124'-0" 1 2 4 2 A3016 7 80 95 OPEN BAY 102A 101H 101J 101K 101L 101M 10’−0"102B ILLUMINATED SIGNAGE CMU1 MP2 DOWNSPOUT, COLOR TO MATCH MP2 (TYP) CONTINUOUS GUTTER, COLOR TO MATCH MP2 CONTINUOUS GUTTER, COLOR TO MATCH MP2 DOWNSPOUT, COLOR TO MATCH MP2 (TYP) 6" BOLLARDDOWNSPOUT, COLOR TO MATCH MP2 (TYP) AIR COMPRESSOR CHAIN LINK FENCE W/ (3) STRANDS OF BARBED WIRE SURROUNDING YARD METAL CANOPY BY PEMB MFR. FINISH TO MATCH PT-5 CONDENSER UNITS MP3 MP3 MP2 MP2MP2MP2 MP1 MP1OPEN BAY MP1 7’−9"13’−2"8’−6" 8’−0" 8’−6" 1 A331 WPWPWPWPWPWP 3 Level 1 100'-0" Roof 124'-0" BA 1" / 12"1 " / 1 2 " MP2 MP1 SHEET METAL FLASHING, COLOR TO MATCH MP2 GUTTER, COLOR TO MATCH MP2 DOWNSPOUT, COLOR TO MATCH MP2 6" BOLLARD CONCRETE PIER PER STRUCT PT EXPOSED STRUCTURE, PT-2 6" BOLLARD CONCRETE PIER PER STRUCT PT EXPOSED STRUCTURE, PT-2 1 A301 The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A201 EXTERIOR ELEVATIONSTier 4Fluid DrLittle Rock, AR 72206EquipmentShare1/8" = 1'-0"2 Exterior Elevation -Overall East 1/8" = 1'-0"1 Exterior Elevation -Overall North 1/8" = 1'-0"3 Exterior Elevation -Overall South 1/8" = 1'-0"4 Exterior Elevation -Overall West SHEET NOTES 1. REFER TO SHEET G000 FOR SHEET INDEX 2. DO NOT SCALE THIS DRAWING 3. REFER TO INTERIOR ELEVATIONS, FOR PLACEMENT OF ALL WALL MOUNTED ITEMS 4. WALL MOUNTED LIGHT FIXTURES, GRILLES AND OTHER MEP ITEMS ARE SHOWN FOR PLACEMENT ONLY Level 1 100'-0" Roof 124'-0" B A 1 A301 MP1 A331 2 Level 1 100'-0" Roof 124'-0" 1 2 4 2 A3016 7 80 95 MP1 UP TO 8' EXPOSED GIRTS & INSULATION ABOVE 8'WASH PIT A332 1 3 The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A301 BUILDING SECTIONSTier 4Fluid DrLittle Rock, AR 72206EquipmentShare1/8" = 1'-0"2 WALL SECTION -OVERHEAD DOORS 1/8" = 1'-0"1 BUILDING SECTION -LONGITUDINAL Level 1 100'-0" Roof 124'-0" B 16’−0"ROOF LINER INSULATION BY PEMB MFR METAL ROOF STRUCTURE W/ INSULATION BY PEMB MFR; R-VALUE PER LOCAL CODE PREFINISHED METAL GUTTER BY PEMB MFR WALL INSULATION BY PEMB MFR, R-VALUE PER LOCAL CODE STEEL GIRT STRUCTURE BY PEMB MFR, OUTSET LED TAPE LIGHT IN 45° HOUSING PEMB METAL PANEL SIDING, MP2 SHEET METAL FLASHING STANDING SEAM METAL ROOF BY PEMB MFR, MP3 8’−0"FOUNDATION & SLAB PER STRUCT VAPOR BARRIER SLAB INSULATION PER LOCAL IECC REQUIREMENTS PAVING PER CIVIL 1/2" EXPANSION MATERIAL DOWNSPOUT PEMB SUPERSTRUCTURE PEMB METAL PANEL SIDING, MP1 INTERIOR METAL PANEL, MP1 8" 8" STEEL GIRT STRUCTURE BY PEMB MFR, INSET Level 1 100'-0" Roof 124'-0" A 16’−0"ROOF LINER INSULATION BY PEMB MFR METAL ROOF STRUCTURE W/ INSULATION BY PEMB MFR; R-VALUE PER LOCAL CODE PREFINISHED METAL GUTTER BY PEMB MFR WALL INSULATION BY PEMB MFR, R-VALUE PER LOCAL CODE STEEL GIRT STRUCTURE BY PEMB MFR, OUTSET HEADER BY PEMB MFR OVERHEAD COILING DOOR HOUSING LED TAPE LIGHT IN 45° HOUSING OVERHEAD COILING DOOR PAVING, RE: CIVIL FOUNDATION & SLAB PER STRUCT VAPOR BARRIER PEMB METAL PANEL SIDING, MP2 SHEET METAL FLASHING STANDING SEAM METAL ROOF BY PEMB MFR, MP3 6" 8" 8" The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.2 11/22/2024 A331 WALL SECTIONSTier 45710 Bull Run Dr.Columbia, MO 65201EquipmentShare3/4" = 1'-0"2 WALL SECTION @ OH DOORS 3/4" = 1'-0"1 TYPICAL WALL SECTION Level 1 100'-0" Roof 124'-0" 9 PEMB SUPERSTRUCTURE SHEET METAL FASCIA, COLOR PER ELEVATIONS SHEET METAL FLASHING & DRIP EDGE SHEET METAL SOFFIT STOREFRONT GLAZING ALUMINUM STOREFRONT PEMB ROOF INSULATION; R-VALUE PER LOCAL CODE STANDING SEAM METAL ROOF, MP3 WRB OVER GYP SHEATHING PEMB BAG INSULATION B/W GIRTS 2’−2" 9 1/4" HSS BY PEMB MFR ALUMINUM STOREFRONT BACKER ROD & SEALANT METAL STUD FRAMING W/ INSULATION GYP SHEATHING & WRB SHEET METAL FLASHING STEEL CHANNEL WELDED TO HSS TUBE STEEL CANOPY, BOLD TO CHANNEL SHEET METAL SOFFIT FLASHING & DRIP EDGE SHEET METAL ROOFING 5’−6" FABRIC LINER SYSTEM GYP SHEATHING & WRB SHEET METAL FASCIA Level 1 100'-0" Roof 124'-0" 9 CMU AIR GAP WRB ON GYPSUM SHEATHING PEMB INSULATION METAL STUD FRAMING 5/8" PTD GYP STEEL GIRTS BY PEMB SUPPLIER SHEET METAL DRIP EDGE 6" METAL STUD FRAMING ATTACHED TO PEMB GIRTS GYPSUM SHEATHING & WRB METAL PANEL SIDING BY PEMB SUPPLIER PEMB SUPERSTRUCTURE SHEET METAL SOFFIT CEILING PER PLANS 2’−2" FULLY GROUT BLOCK BELOW GRADE EXPANSION JOINT PAVING PER CIVIL METAL THRU-WALL FLASHING MORTAR NET10’−0"SHEET METAL FASCIA, COLOR PER ELEVATIONS SHEET METAL FLASHING & DRIP EDGE PEMB ROOF INSULATION; R-VALUE PER LOCAL CODE STANDING SEAM METAL ROOF, MP3 WRB OVER GYP SHEATHING PEMB BAG INSULATION B/W GIRTS The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.2 11/22/2024 A332 WALL SECTIONSTier 45710 Bull Run Dr.Columbia, MO 65201EquipmentShare3/4" = 1'-0"2 WALL SECTION @ FRONT FACADE 3/4" = 1'-0"1 WALL SECTION @ ENTRY STOREFRONT TOILET ROOM ACCESSORY SCHEDULE NOTES: 1. REFER TO A401 FOR FIXTURE AND ACCESSORY MOUNTING HEIGHTS. CONTRACTOR IS TO PROVIDE ALL BLOCKING NECESSARY FOR PROPER INSTALLATION. INSTALL PER MANF. RECOMMENDATIONS. 2. VENDOR PROVIDED SOAP DISPENSERS, PAPER TOWEL DISPENSERS, AND TRASH DISPOSALS MAY NOT PROTRUDE INTO CLEAR FLOOR SPACE REQUIREMENTS. 3. NO SUBSTITUTIONS ALLOWED. CONTRACTOR TO SUBMIT SHOP DRAWINGS/ CUT SHEETS FOR APPROVAL ON FINAL SELECTION. 4. ALL DIMENSIONS TO BE VERIFIED WITH PRODUCT REQUIREMENTS. INSTALL PER MANF. RECOMMENDATIONS. 5. REFER TO PLUMBING SHEETS FOR PLUMBING FIXTURE SCHEDULE. 6. REFER TO ELECTRICAL SHEETS FOR LIGHTING SCHEDULE. TAG ITEM MODEL GB/VGB TTD MI SD ADA GRAB BARS TOILET TISSUE DISPENSER SOAP DISPENSER PTD SNR SANITARY NAPKIN RECEPTACLE MIRROR PAPER TOWEL DISPENSER FINISHMANUFACTURER RESPONSIBILITY NOTES SIZES VARY; RE: DRAWINGS. MCH METAL COAT HOOKS BRADLEY 812 SERIES STAINLESS STEEL VPCI VPVI BRADLEY 780 SERIES VPCI VPVI VPVI BRADLEY BX 4722-150000 STAINLESS STEEL CPCI BRADLEY 9124-00 STAINLESS STEEL CPCI -- -- -- -- -- -- -- -- -- -- MOUNTED AT 54" AFF SD NOTE: ACCESSORIES SHOWN ARE REPRESENTATIONAL ONLY. REFER TO SPECIFICATIONS FOR FIXTURE TYPES USED IN THIS PROJECT. GB GB MIN. 24" MIN 12" 12" MAX 42" MIN 54" MIN VGB 40"18" MIN40"36" MIN TTD TO OUTLET18" MINTO CL 7"− 9"30"1 1/2" MINSNR OF BAR34" TOPPTD OPERABLE PART48" MAX TOWR PTDR SND RH CH MI M2 AND COUNTERS40" MAX ATLAVATORIESSURFACE35" MAX TOREFLECTIVE15"− 16"18"FSS 57"TS MBH 54"EHD 40" ADA42" STD4"27" MIN34" MAXOPERABLE PART48" MAX TODCSOF BAR34" TOP40"SH FULL−LENGTH M374" MIN. AT GENERAL ACCESSORY MOUNTING HEIGHTS B A 7 8 9 304 SF BREAK ROOM 105 235 SF SERVICE OFFICE 108 63 SF IT CLOSET/ STORAGE 110 960 SF LOBBY 113 59 SF WOMEN'S SINGLE STALL 106 149 SF MEN'S MULTI-STALL 111 119 SF MEN'S SHOP MULTI-STALL 103 71 SF UTILITY 104 349 SF CONFERENCE / TRAINING 112 138 SF GENERAL MANAGER 107 354 SF PARTS ROOM 109 104A113B 108B 108A110A 107A 109A 105A 112A108C113A 9’−7 1/4" 14’−10 1/2" A401 4 A401 3 A401 2 17’−0"8’−10 1/4" 16’−6" 16’−0" 9’−4 1/4"7’−10"14’−8"10’−0"5’−5"7’−9"1’−3"D 13B 13B 15B 15B 16B 13B 13B 13B 13B 13B 13B 13B 16B 13B13B A340 1 A340 2 A340 3 15’−0 1/2"1’−5 1/2"5’−9 1/2"1’−5 1/2"FLOOR BOXES PER ELEC A421 14 A421 3 4 1 2 A421 13A 103A 119 SF MEN'S SHOP MULTI-STALL 103 304 SF BREAK ROOM 105 71 SF UTILITY 104 960 SF LOBBY 113 60" X 56" CLEAR TOILET FLOOR SPACE. HAND SINK, TOWEL DISPENSERS, SOAP DISPENSERS, AND TOWEL DISPOSAL NOT TO OVERLAP TOILET PARTITIONS RE: SPECIFICATIONS FLOOR MOUNTED TOILET, TYP. RE: PLUMBING GB TTD WALL HUNG URINAL, TYP. RE: PLUMBING URINAL SCREENS RE: SPECIFICATIONS MI SD 48" X 30" CLEAR LAVATORY FLOOR SPACE, TYP 60" CLEAR FLOOR SPACE 30" X 48" CLEAR FLOOR SPACE- PARALLEL ADA VGB PTD A42112 9 10 11 111A 149 SF MEN'S MULTI-STALL 111 60" X 56" CLEAR TOILET FLOOR SPACE. HAND SINK, TOWEL DISPENSERS, SOAP DISPENSERS, AND TOWEL DISPOSAL NOT TO OVERLAP 60" CLEAR FLOOR SPACE 48" X 30" CLEAR LAVATORY FLOOR SPACE SD TOILET PARTITIONS RE: SPECIFICATIONS FLOOR MOUNTED TOILET, TYP. RE: PLUMBING WALL HUNG URINAL, TYP. RE: PLUMBING URINAL SCREENS. RE: SPECIFICATIONS MI GB TTD VGB PTD A421 5 8 6 7 106A 59 SF WOMEN'S SINGLE STALL 106 48" X 30" CLEAR LAVATORY FLOOR SPACE SNR TTD PTD MCH FLOOR MOUNTED TOILET, RE: PLUMBING GB MI SD WALL-HUNG LAVATORY, RE: PLUMBING 60" X 56" CLEAR TOILET FLOOR SPACE. HAND SINK, TOWEL DISPENSERS, SOAP DISPENSERS, AND TOWEL DISPOSAL NOT TO OVERLAP 60" CLEAR FLOOR SPACE VGB The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A401 ENLARGED PLANS -OFFICETier 4Fluid DrLittle Rock, AR 72206EquipmentShare1/4" = 1'-0"1 Enlarged Office Floor Plan 1/2" = 1'-0"2 Enlarged Men's Shop Multi-Stall, Break Room, & Coffee Bar 1/2" = 1'-0"4 Enlarged Men's Multi-Stall 1/2" = 1'-0"3 Enlarged Women's Single Stall PLAN NORTH 1 2 B A 102B 102A 102F 102D 102E 102C 1/8" / 12"2" / 12"4’−0" 1’−0" 396 SF EQUIPMENT ROOM 102.1 1,332 SF WASH BAY 102 1 13/16" / 12"-3'-6" -4'-6"-4'-6" 0" -6" 1'-0"1'-0" CHAIN LINK FENCE ON CONCRETE CURB, 6'-0" A.F.F. PIT 2 PIT 3 PIT 1 17B 17B 5 1/2" 10’−9" 1’−0" 22’−9 1/2" 11" 5’−1 1/2" 1’−0" 4’−7 1/2"1"19’−10 1/2" 1’−0" 7’−7 1/2" 1’−0"30’−6"3’−8 3/4"22’−11" 12’−1" 18BBOLT-DOWN POST & CHAIN FALL PROTECTION 1 1 2 2 2 2 2 2 2 3 A402 3 A402 2 A402 2 A402 1/4" / 12" Level 1 100'-0" 1 3 A402 BOLT DOWN POST + CHAIN FALL PROTECTION 4’−10"4’−10" Level 1 100'-0" B2 A402 1’−0" 4’−0" CHAIN LINK FENCE FLOOR LINE, BEYOND BOLT DOWN POST + CHAIN FALL PROTECTION 5’−0" FENCE1’−0" CURBThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. SHEET KEYNOTE LEGEND E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A402 ENLARGED PLANS -WASH BAYTier 4Fluid DrLittle Rock, AR 72206EquipmentShare1/4" = 1'-0"1 ENLARGED PLAN -WASH BAY 1. 4" PVC PIPE THRU B.O. CONCRETE WALL 2. 12" CONCRETE STEM WALL UNDER FRAMED WALL, 1'-0" A.F.F. 1/4" = 1'-0"2 WASH BAY SECTION 1 1/4" = 1'-0"3 WASH BAY SECTION 2 1/4" = 1'-0"4 WASH BAY EQUIPMENT PLAN TB - 1 EP - 3 (6) COURSES TL - 1 TB - 1 EP - 3 (6) COURSES TL - 1 PTD TB - 1 (6) COURSES TL - 1 PROVIDE BLOCKING BEHIND GRAB BARS EP - 3 MI SD TB - 1 PROVIDE BLOCKING BEHIND GRAB BARS EP - 3 (6) COURSES TL - 1 TTD TB - 1 EP - 3 (6) COURSES TL - 1 PTD PROVIDE BLOCKING BEHIND GRAB BARS TB - 1 (6) COURSES TL - 1 EP - 3 MI SD EP - 3 TB - 1 PROVIDE BLOCKING BEHIND GRAB BARS (6) COURSES TL - 1 TTD 2’−0" 36" REF BY OWNER 20 A421 18 A421 17 A421 WB-1 2" PLAM-1 FILLER (2) COURSES TL - 2 MICRO BY OWNER 17 A421 2’−0"3’−0"2’−0" 21 A421 2" PLAM-1 FILLER 2’−6"1’−8"2’−10"(2) COURSES TL - 2 PL - 1 SHELF WB - 1 18 A421 1’−8"2’−10"1’−0"3’−0"1’−6"1’−7"3"20 A421 19 A421 15 A421 EP - 3 TB - 1 (6) COURSES TL - 1 HARDWARE SEE SPECIFICATIONS BASE AS SCHEDULED DOWEL HOLES 2" OC 3/4" PLASTIC LAMINATE ON PARTICLE BOARD (1" IF CABINET LENGTH EXCEEDS 36") BACKING SHEET 1/2" MIN. BACK PANEL 24" 1"34"3" 2 CONCEALED HINGES PER DOOR 1"4"5"1 1/2"1/2"1/8"TILE BACKSPLASH / 4" COUNTERTOP MATERIAL BACKSPLASH AS INDICATED RE: ELEVATION COUNTERTOP AS SCHEDULED HARDWARE SEE SPECIFICATIONS 1/2" MIN. BACK PANEL 1/2" 24" BASE AS SCHEDULED1 1/2"1/2"5"1/8"EQ.1/8"EQ.1/8"EQ.34"4"3" BACKING SHEET 3/4" PLASTIC LAMINATE ON PARTICLE BOARD (1" IF CABINET LENGTH EXCEEDS 36") TILE BACKSPLASH / 4" COUNTERTOP MATERIAL BACKSPLASH AS INDICATED RE: ELEVATION COUNTERTOP AS SCHEDULED WOOD BLOCKING (W/ MIN. OF 2 GAPS PER SINK FOR CLAMPS) SINK HARDWARE SEE SPECIFICATIONS 1/2" MIN. BACK PANEL 1" 24"BASE AS SCHEDULED34"1/8"2 CONCEALED HINGES PER DOOR 3"1"4"5"1/2"1 1/2"TILE BACKSPLASH / 4" COUNTERTOP MATERIAL BACKSPLASH AS INDICATED RE: ELEVATION COUNTERTOP AS SCHEDULED HARDWARE SEE SPECIFICATIONS DOWEL HOLES @ 2" OC 3/4" PLASTIC LAMINATE ON PARTICLE BOARD 3/4" PLASTIC LAMINATE ON PARTICLE BOARD DOOR 1/2" MIN. BACK PANEL2’−6" (2 SHELVES) / 2’ − 0" ( 1 SHELF)2 CONCEALED HINGES PER DOOR MTL. STUD BACKING PLATE 1’−2"7’−0" AFF304 SF BREAK ROOM 105 235 SF SERVICE OFFICE 108 63 SF IT CLOSET/ STORAGE 110 960 SF LOBBY 113 59 SF WOMEN'S SINGLE STALL 106 149 SF MEN'S MULTI-STALL 111 119 SF MEN'S SHOP MULTI-STALL 103 71 SF UTILITY 104 349 SF CONFERENCE / TRAINING 112 138 SF GENERAL MANAGER 107 354 SF PARTS ROOM 109 TL -1 TL -2 1 TL -1 CPT -1 PT -3 PT -3 CPT -1 TL -1 CPT -1 PT -4 PT -3 TL -2 PC -11PC -1PC -1 CPT -1 SC -1 CPT -1PC -1 PC -1 PT -4 GENERAL FINISH NOTES 1. REFER TO FINISH FLOOR PLANS, REFLECTED CEILING PLANS, ELEVATIONS, AND DETAILS FOR EXTENT OF MULTIPLE FINISHES. 2. DO NOT PAINT NATURAL OR MANUFACTURED STONE, BRICK, GLAZED BLOCK OR ANY OTHER PREFINISHED MATERIALS. 3. DO NOT PAINT ALUMINUM OR OTHER NON-FERROUS METALS THAT ARE PREFINISHED. 4. MATCH VERTICAL FINISH OF ALL INTERIOR GYPSUM BOARD SOFFITS TO HORIZONTAL FINISH AS NOTED ON RCP OR ROOM FINISH SCHEDULE, UNO. 5. PAINT ALL EXPOSED CEILINGS DESIGNATED AS ‘OTS’ AS INDICATED ON ROOM FINISH SCHEDULE. PAINTING INCLUDES, BUT IS NOT LIMITED TO: EXPOSED STRUCTURE, JOISTS, METAL DECKING, EXISTING TECTUM PANELS, DUCTWORK AND MECH EQUIPMENT. 6. PAINT ALL EXPOSED STEEL, UNO. 7. PAINT ALL INTERIOR HOLLOW METAL DOORS AND FRAMES COLOR PT-4, UNO. 8. PAINT OR FINISH THE FOLLOWING ITEMS TO MATCH ADJACENT PAINT OR FINISH: a. ELECTRICAL PANELS IN FINISHED ROOMS b. GRILLES, LOUVERS ETC. PRIMED OR SPECIFIED TO BE PAINTED c. UNFINISHED SPEAKER OUTLET GRILLES d. VISIBLE PORTIONS OF DUCTWORK AND MECH EQUIPMENT BEHIND VENTS, GRILLES AND DIFFUSERS TB - 1 PROVIDE BLOCKING BEHIND GRAB BARS EP - 3 (6) COURSES TL - 1 TTD SNR TB - 1 EP - 3 (6) COURSES TL - 1 TB - 1 EP - 3 (6) COURSES TL - 1 PTD TB - 1 PROVIDE BLOCKING BEHIND GRAB BARS EP - 3 (6) COURSES TL - 1 MI SD COUNTERTOP AS SCHEDULED CONT. 3"x3"x1/4" ANGLE BASE AS SCHEDULED 1/2" PARTICLE BOARD WITH PLASTIC LAMINATE 1 1/2"x1 1/2"x1/8" STEEL ANGLE 9"6" 9"34"TILE BACKSPLASH / 4" COUNTERTOP MATERIAL BACKSPLASH AS INDICATED RE: ELEVATION 7" APRON1 1/2"SINK ADA SINK; SHALLOW BOWL2’−1" CONTINUOUS, CONCEALED SUPPORT BRACKET METAL STUD BACKING PLATE ALL SIDES FINISHED, PLAM-1 1’−0" INTERIOR FINISH SPECIFICATIONS BRAND: BENJAMIN MOORE COLOR: DECORATOR'S WHITE CC-20 PT / EP - 1 = PAINT COLOR 1 (WHITE GYP. CEILINGS) BRAND: BENJAMIN MOORE COLOR: GRAY OWL 2137-60 PT / EP - 2 = PAINT COLOR 2 (ALL WALLS UNO) BRAND: BENJAMIN MOORE COLOR: CAPE MAY COBBLESTONE 1474 PT / EP - 3 = PAINT COLOR 3 (ACCENT WALLS AS SPECIFIED) SUPPLIER: NEVAMAR COLOR/FINISH: ILLUSTRIOUS MAPLE WM0046 TEXTURED ORIENTATION: ALL WOOD GRAIN TO RUN VERTICALLY PL-1 = PLASTIC LAMINATE FINISH: REFER TO ARCHITECTURAL SPECIFICATIONS PC - 1 = POLISHED CONCRETE MANUFACTURER: DALTILE COLOR: URBANIZE GREY UB04 SIZE: 12" x 24" INSTALLATION: MONOLITHIC GROUT: 3/16" SANDED, MAPEI 5027 SILVER TRANSITION:SCHLUTER RENO-RAMP SIZED AS NEEDED, SATIN ANODIZED FINISH. TL - 1 = PORCELAIN FLOOR & WALL TILE (RESTROOMS) TYPE: 4" ROPPE COVE/STRAIGHT RE:SPECIFICATIONS COLOR: 100 BLACK WB - 1 = WALL BASE SUPPLIER: INTERFACE LINE / COLOR: OPEN AIR 412; BLACK; 106985 SIZE / INSTALL:50cm X 50cm; MONOLITHIC NOTES: GLASBAC BACKING TRANSITION STRIP: ROPPE EDGE GUARD #35 OR SIMILAR. 1/4" ADA UNDERLAP CARPET TO CONCRETE IN 100 BLACK. CPT - 1 = CARPET COLOR: MATCH TO PAINT SYSTEM'S COLOR ABOVE FINISH: SEMIGLOSS EPOXY EP - "X" = EPOXY WALL PAINT COLOR: MATCH TO PAINT SYSTEM'S COLOR ABOVE FINISH: EGGSHELL PT - "X" = WALL PAINT MANUFACTURER: DALTILE COLOR: REMEDY ALCHEMY RD25 SIZE: 2" x 10" INSTALLATION: MONOLITHIC VERTICAL, RE: ELEVATIONS GROUT:3/16" UNSANDED, MAPEI 5010 BLACK TL - 2 = WALL TILE (SPECIALTY ACCENT) FINISH: REFER TO ARCHITECTURAL SPECIFICATIONS SC - 1 = SEALED CONCRETE BRAND: BENJAMIN MOORE COLOR: BLACKTOP 2135-10 PT / EP - 4 = PAINT COLOR 4 (ACCENT WALLS AS SPECIFIED) BRAND: SHERWIN WILLIAMS COLOR: SW 6886 INVIGORATE PT / EP - 5 = PAINT COLOR 5 (ACCENT WALLS AS SPECIFIED) SUPPLIER: CORIAN COLOR: PEPPERED TERRAZZO EDGE: EASED SS-1 = SOLID SURFACE COUNTERTOP PT - 0 = NO PAINT AN NO WALL BASE - TAPE AND FLOAT ONLY MP - 1 = METAL PANEL WALL LINER PANELS PBM PROFILE 26 GUAGE 'HIGH GLOSS WHITE' TO 7' - 8" AFF TB - 1 = PORCELAIN TILE WALL BASE (RESTROOM WALLS) MANUFACTURER: DALTILE COLOR: URBANIZE GREY UB04 SIZE: 12" x 24" - CUT TO 6" X 24" INSTALLATION: MONOLITHIC GROUT: 3/16" SANDED, MAPEI 5027 SILVER REF BY OWNER MICRO BY OWNER 19 A421 16 A421 FINISHES THIS ELEVATION SIM TO 13/A421 COUNTERTOP AS SCHEDULED 1/2" MIN. BACK PANEL 24"BASE AS SCHEDULED1 1/2"1’−1 1/4"EQ.1/8"EQ.34"4"3" ALL EXPOSED SURFACES IN MICRO CAVITY TO BE FINISHED WITH PL-1 3/4" PLASTIC LAMINATE ON PARTICLE BOARD TILE BACKSPLASH / 4" COUNTERTOP MATERIAL BACKSPLASH AS INDICATED RE: ELEVATION 1" 1" MICROWAVE BY OWNER EXTEND DUPLEX FACEPLATE TO PL-1 SURFACE CHECK SET The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. SHEET KEYNOTE LEGEND E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A421 INTERIOR FINISH PLANS, ELEV & DETAILSTier 4Fluid DrLittle Rock, AR 72206EquipmentShareROOM FLOOR WALLS CEILING Finish RemarksNONameFinishBaseNorthEastSouthWestFinish 101 SHOP SC - 1 N/A MP - 1 MP - 1 MP - 1 MP - 1 SEE RCP 102 WASH BAY SC - 1 N/A MP - 1 MP - 1 MP - 1 MP - 1 SEE RCP 102.1 EQUIPMENT ROOM SC - 1 N/A MP - 1 MP - 1 MP - 1 MP - 1 SEE RCP 103 MEN'S SHOP MULTI-STALL TL - 1 TB - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 SEE RCP 104 UTILITY SC - 1 N/A PT - 0 PT - 0 PT - 0 PT - 0 SEE RCP 105 BREAK ROOM PC - 1 WB -1 PT - 4 PT - 2 PT - 2 PT - 2 SEE RCP REFER TO ES DAM FOR VINYL WALL GRAPHIC PATTERNS 106 WOMEN'S SINGLE STALL TL - 1 TB - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 SEE RCP 107 GENERAL MANAGER CPT - 1 WB -1 PT - 3 PT - 2 PT - 2 PT - 2 SEE RCP 108 SERVICE OFFICE CPT - 1 WB -1 PT - 2 PT - 2 PT - 3 PT - 2 SEE RCP 109 PARTS ROOM SC - 1 WB -1 EP - 2 EP - 2 EP - 2 EP - 2 SEE RCP 110 IT CLOSET/ STORAGE PC - 1 WB -1 PT - 2 PT - 2 PT - 2 PT - 2 SEE RCP 111 MEN'S MULTI-STALL TL - 1 TB - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 EP - 3 / TL - 1 SEE RCP 112 CONFERENCE / TRAINING CPT - 1 WB -1 PT - 2 PT - 2 PT - 2 PT - 4 SEE RCP 112B CLOSET CPT - 1 WB - 1 PT - 2 PT - 2 PT - 2 PT - 2 SEE RCP 113 LOBBY PC - 1 WB - 1 PT - 2 PT - 2 PT - 2 PT - 3 SEE RCP REFER TO ES DAM FOR VINYL WALL GRAPHIC PATTERNS 3/16" = 1'-0"22 Wall and Floor Finishes Plan 1/4" = 1'-0"12 Men's Multi-Stall (West) 1/4" = 1'-0"9 Men's Multi-Stall (North) 1/4" = 1'-0"10 Men's Multi-Stall (East) 1/4" = 1'-0"11 Men's Multi-Stall (South) 1/4" = 1'-0"4 Men's Shop Multi-Stall (West) 1/4" = 1'-0"1 Men's Shop Muti-Stall (North) 1/4" = 1'-0"2 Men's Shop Multi-Stall (East) 1/4" = 1'-0"13 Break Room Elevation 1/4" = 1'-0"14 Coffee Bar 1/4" = 1'-0"3 Men's Shop Multi-Stall (South) 1" = 1'-0"18 Millwork -Base Cabinet -Door 1" = 1'-0"19 Millwork -Base Cabinet -Drawers 1" = 1'-0"20 Millwork -ADA Parallel Approach Lav 1" = 1'-0"17 Millwork -Upper Cabinet ROOM FINISH SCHEDULE 1/4" = 1'-0"5 Women's Single Stall (North) 1/4" = 1'-0"6 Women's Single Stall (East) 1/4" = 1'-0"7 Women's Single Stall (South) 1/4" = 1'-0"8 Women's Single Stall (West) 1" = 1'-0"16 Millwork -ADA Front Approach Lav 1" = 1'-0"15 Shelf Section LEVEL 5 GYP BOARD FINISH WITH APPLIED WALL GRAPHIC THIS WALL. 1/4" = 1'-0"13A ADA Front Approach Break Room Elev 1" = 1'-0"21 Millwork -ADA Mircowave Base Cabinet 1 PLAN NORTH DOOR TYPE NOTES 1. REFER TO DOOR SCHEDULE FOR OVERALL DOOR DIMENSIONS 2. DIMENSIONS ASSOCIATED WITH VISION LITES ARE TO THE OUTSIDE OF THE VISION LITE FRAME UNLESS NOTED OTHERWISE 3. REFER TO DOOR SCHEDULE TO DETERMINE WHICH DOORS ARE REQUIRED TO BE FIRE RATED 4. ALL GLASS IN DOORS TO BE LOW-E FULLY TEMPERED INSULATED GLASS (1") UNLESS NOTED OTHERWISE 5. ALL DOOR DIMENSIONS TO BE FIELD VERIFIED PRIOR TO FABRICATION AND INSTALL. 6. ALL DOORS TO BE PROVIDED WITH REQUESTED ACCESSORIES FROM OWNER. 7. ALL NECESSARY DOORS (PER CODES AND ORDINANCES) TO BE PROVIDED WITH FULLY FUNCTIONING DOOR CLOSER. CLOSER TO MEET ALL ADA AND MANUFACTURER REQUIREMENTS. DOORS TO INCLUDE BUT NOT LIMITED TO: RESTROOM DOORS; EGRESS (GLASS) DOORS. 8. ALL HOLLOW METAL DOORS AND FRAMES TO BE PAINTED TO MATCH ADJACENT WALL SURFACE. 9. ALL SOLID CORE / PRE HUNG DOORS TO BE PAINTED TO MATCH ADJACENT WALL SURFACE UNLESS NOTED OTHERWISE. 10. COORDINATE ALL DOOR HARDWARE, LOCKING MECHANISMS, ACCESSORIES WITH ACCESS CONTROL VENDOR AND OWNER. ALL DOORS TO BE FULLY FUNCTIONING IN ACCORDANCE WITH OWNER'S NEEDS. 11. ALL DOOR HARDWARE TO BE ASSA ABLOY OR EQUAL 12. ALL DOOR HARDWARE TO BE INSTALLED PER THE CODES INDICATED ON THE CODE SUMMARY SHEET. 13. DOORS SUPPLIED WITH AN ASTERISK (*) TO BE PROVIDED WITH ACCESS CONTROL (KEY FOB SYSTEM OR OTHERWISE DIRECTED BY OWNER) WINDOW TYPE NOTES 1. ALL GLASS IN EXTERIOR DOORS TO BE LOW-E FULLY TEMPERED INSULATED GLASS (1") UNLESSS NOTED OTHERWISE 2. ALL WINDOW DIMENSIONS TO BE FIELD VERIFIED PRIOR TO FABRICATION & INSTALL 3. ALL WINDOWS TO BE PROVIDED WITH REQUESTED ACCESSORIES FROM OWNER 4. COORDINATE HARDWARE OPTIONS / SELECTION WITH OWNER (WHERE APPLICABLE) 5. REFERENCE ELEVATIONS TO VERIFY SILL HEIGHTS SHOULD ANY WINDOW TYPES VARY BASED ON INDIVIUAL LOCATIONS AND INSTALLATIONS 6. INSTALL TEMPERED AND / OR SAFETY GLAZING PER CODES INDICATED ON CODE SUMMARY SHEET. WALL TYPE NOTES 1. REFER TO WALL SECTIONS AND EXTERIOR ELEVATIONS FOR WALL HEIGHTS 2. REFER TO EXTERIOR ELEVATIONS FOR DESIGNATION OF EXTERIOR MATERIAL CHANGES AND FINISHES / COLORS 3. OVERALL WIDTH DIMENSIONS OF WALL TYPES GO TO EITHER FACE OF STUD OR TO FACE OF INTERIOR CMU 4. REFER TO PARTITION TYPE SUMBOLS ON FLOOR PLANS 5. REFER TO CODE PLAN FOR MINIMUM REQUIRED FIRE RATING IN HOURS. 6. PARTITION TYPES DO NOT INDICATE WHICH SIDE FINISH MATERIALS ARE APPLIED. REFER TO FINISH PLAN. 7. FIRE RATED WALLS SHALL MAINTAIN FIRE RATING AS SCHEDULED CONTINUOUSLY TO UNDERSIDE OF SLAB OR ROOF DECK. 8. PARTITIONS ARE DIMENSIONED TO THE FACE OF THE GYPSUM/VENEER/BACKER BOARD, NOT APPLIED FINISH MATERIAL 9. COORDINATE THE LOCATION OF FIRE RATED PARTITIONS ON THE CODE PLANS. 10. REFER TO THE STRUCTURAL DRAWINGS FOR DESIGN OF LOAD BEARING PARTITIONS 11. HOLD ALL GYPSUM BOARD 1/2" ABOVE CONCRETE SLAB TO AVOID WICKING ACTION 12. WHERE GYPSUM BOARD IS INDICATED TO BE INSTALLED AT WET LOCATIONS, INCLUDING BUT NOT LIMITED TO TOILETS AND JANITOR'S CLOSETS, MOISTURE AND MOLD RESISTANT GYPSUM BOARD SHALL BE PROVIDED. 13. RE: ELEVATIONS FOR EXTERIOR MATERIAL CHANGES 08 11 13.A31 TYPE A DOOR - FLUSH 08 11 13.A31 TYPE B DOOR - DOUBLE STOREFRONT ENTRYPER SCHEDPER SCHED PER SCHED PER SCHED6"6"6"10"08 11 13.A31 TYPE D DOOR - OVERHEAD COILING PER SCHED PER SCHEDCOIL HOUSING 08 11 13.A31 TYPE C DOOR - FULL LITE PER SCHEDPER SCHED 10"8"8"8" T T T 2" SCHED PER 2"2" 1’−10" 2" SCHED PER 2"2"PER SCHED4"08 11 13.A31 08 11 13.A31PER SCHED 2" 5’−4" TYPE 1 FRAME - HOLLOW METAL TYPE 2 FRAME - HOLLOW METAL W/ VISION LITE T 13A 13B 13C 13D4" MIN4" MIN3 5/8" METAL STUD GYPSUM WALL BOARD ONE SIDE 3 5/8" METAL STUD GYPSUM WALL BOARD ONE SIDE METAL STUD GYPSUM WALL BOARD BOTH SIDES ACOUSTIC BATTING WHERE SHOWN ON PLANS 3 5/8" METAL STUD GYPSUM WALL BOARD BOTH SIDES ACOUSTIC BATTING WHERE SHOWN ON PLANS INT-13a -3 5/8" Mtl Stud w (1) 5/8" Gyp each side -AC -4 7/8" INT-13b -3 5/8" Mtl Stud w (1) 5/8" Gyp each side -TD -4 7/8" INT-13c -3 5/8" Mtl Stud w (1) 5/8" Gyp room side -AC -4 1/4" INT-13d -3 5/8" Mtl Stud w (1) 5/8" Gyp room side -TD -4 1/4" 15A 15B 15C4" MIN4" MIN16B INT-15a -6" Mtl Stud w (1) 5/8" Gyp each side -AC -7 1/4" INT-15b -6" Mtl Stud w (1) 5/8" Gyp each side -TD -7 1/4" INT-15c -6" Mtl Stud w (1) 5/8" Gyp room side -AC -6 5/8" ONE SIDE 6" Metal Building Wall Panel with 6" Framing 1/2 Gyp METAL BUILDING WALL PANEL 3-5/8" METAL BUILDING WALL PANEL 8" METAL BUILDING WALL PANEL METAL STUDMETAL STUDMETAL STUD GYPSUM WALL BOARD ONE SIDE 6" METAL STUD GYPSUM WALL BOARD 6" METAL STUD GYPSUM WALL BOARD ACOUSTIC BATTING WHERE SHOWN ON PLANS BOTH SIDES 6" METAL STUD GYPSUM WALL BOARD BOTH SIDES BATT INSULATION R-12 MIN Varies Top of Wall Varies Bottom of Wall C1 1’−0" 6" AIR GAP 3 5/8" CMU VENEER WRB 1 3/4" GYPSUM SHEATHING METAL STUD Level 1 100'-0" Roof 124'-0" 113A A 3’−0"7’−0"8’−8" 4’−3 3/8" 1" / 12"13’−11 5/8"12’−4" 3’−2" 6’−0" 3’−2"12’−11 3/8"EQ EQ EQ EQ T T T T3’−0" 4’−2" 12’−0" EQEQEQ BC4’−2"3’−0"14’−0" 3’−6" 3’−6" 3’−6" 3’−6"4’−2"3’−0"4’−0" D The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A501 DOOR SCHEDULE & DETAILSTier 4Fluid DrLittle Rock, AR 72206EquipmentShareDOOR Frame Fire Rating RemarksNumberSizeTypeGlassTypeMaterial 101A 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101B 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101C 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101D 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 101E 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101F 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101G 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101H 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101J 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 101K 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101L 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 101M 14'-0" x 14'-0"D -----ELECTRICAL OPERATION 102A 16'-0" x 16'-0"D -----ELECTRICAL OPERATION 102B 8'-0" x 10'-0"D -----ELECTRICAL OPERATION 102C 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 102D 16'-0" x 16'-0"D -----ELECTRICAL OPERATION 102E 3'-0" x 7'-0" x 1 3/4" 2 A --1 HM -- 102F 6'-0" x 9'-0"D -----ELECTRICAL OPERATION 103A 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 104A 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 105A 3'-0" x 7'-0" x 1 3/4 C --1 AL -- 106A 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 107A 3'-0" x 7'-0" x 1 3/4 C --1 AL -- 108A 3'-0" x 7'-0" x 1 3/4 C --1 AL -- 108B 3'-0" x 7'-0" x 1 3/4 C --1 AL -- 108C 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 109A 8'-0" x 10'-0"D -----ELECTRICAL OPERATION 110A 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 111A 3'-0" x 7'-0" x 1 3/4"A --1 HM -- 112A 3'-0" x 7'-0" x 1 3/4 C --1 AL -- 113A PR 3'-0" x 7'-0" x 1 3/4"B --2 ALUM -- 113B 3'-0" x 7'-0" x 1 3/4"C --1 ALUM -- 1/4" = 1'-0"1 DOOR & FRAME TYPES STOREFRONT WINDOW TYPES EXTERIOR - STOREFRONT W/ 1" I.G.U.; TEMPERED WHERE REQUIRED; ANODIZED BLACK; KAWNEER 451T OR EQUAL INTERIOR - STOREFRONT W/ 1/4" GLAZING; TEMPERED WHERE REQUIRED; ANODIZED BLACK; KAWNEER 450 OR EQUAL WALL TYPES D DOSSOS J J JOSS OS S S B A 7 8 9 304 SF BREAK ROOM 105 235 SF SERVICE OFFICE 108 63 SF IT CLOSET/ STORAGE 110 960 SF LOBBY 113 59 SF WOMEN'S SINGLE STALL 106 149 SF MEN'S MULTI-STALL 111 119 SF MEN'S SHOP MULTI-STALL 103 71 SF UTILITY 104 349 SF CONFERENCE / TRAINING 112 138 SF GENERAL MANAGER 107 354 SF PARTS ROOM 109 42"42" 3A 3B 2 30" 30" 2A 2A2B 2 48" X 144" 3’−6" 4’−6"3’−6" 9’−0"15’−0" 11’−0"6’−6" 15’−6" SHEET NOTES 1. FURNITURE SHOWN THIS SHEET ARE EQUIPMENTSHARE STANDARDS FOR BRANCH OUTFITS, AS OUTLINED BY THE INTERIOR DESIGN DEPARTMENT. PLEASE EMAIL FURNITURE@EQUIPMENTSHARE.COM TO COORDINATE ORDER AND INSTALLATION OF FURNITURE FOR BRANCHES. 2. STORAGE FURNITURE IS INTENDED TO BE A SEPARATE ORDER FROM THE STANDARD FURNITURE ABOVE. THESE ITEMS ARE TO BE DETERMINED PER USER-SPECIFIC NEEDS. THESE MAY BE ORDERED THROUGH THE STAPLES PROGRAM OUTLINED ON THE ARCHITECTURAL DESIGN DEPARTMENT'S ESOPS PAGE. 3. ELECTRICAL LOCATIONS SHOWN IN THE FURNITURE PLAN ARE FOR COORDINATION WITH FURNITURE PIECES AND CALLED OUT LOCATIONS ONLY. REFER TO ELECTRICAL SHEETS FOR FULL EXTENTS OF POWER PLANS. 4. VINYL WALL DECALS MAY BE ORDERED THROUGH THE EQUIPMENTSHARE DAM WEBSITE (DIGITAL ASSET MANAGEMENT) 5. CANVAS PRINTS MAY BE ORDERED THROUGH THE EQUIPMENTSHARE DAM WEBSITE (DIGITAL ASSET MANAGEMENT) 6. EQUIPMENTSHARE NATIONAL VENDORS AS FOLLOWS: BRANCH GENERAL FURNITURE: SCOTT RICE EQUIPMENTSHARE VENDOR ID: V34249 EMAIL: FURNITURE@EQUIPMENTSHARE.COM BRANCH STORAGE FURNITURE: STAPLES EQUIPMENTSHARE VENDOR ID: V11241 EQUIPMENTSHARE NATIONAL ACCOUNT #: 1868911DAL EMAIL: FURNITURE@EQUIPMENTSHARE.COM The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. E quipmentShare 5710 Bull Run Rd. Columbia, MO 65201 ARCHITECT CONSTRUCTION CIVIL STRUCTURAL MEP ISSUE VERSION: 1.1 - Little Rock 01/24/2025 A901 FURNITURE & POWER COORDINATION FLOOR PLANTier 4Fluid DrLittle Rock, AR 72206EquipmentShare1/4" = 1'-0"1 Furniture & Power Coordination Plan PLAN NORTH SHEET KEYNOTE LEGENDREVISIONSEquipmentShare5710 Bull Run Rd.Columbia, MO 65201ARCHITECTCONSTRUCTIONCIVILSTRUCTURALMEPTier 4 5710 Bull Run Dr. Columbia, MO 65201 EquipmentShareDeVFriptionDateCOVER / GENERAL STRUCTURAL DATAS100FOUNDATION PLANS200INDEX OF SHEETSEquipment Share - Tier 4City, County, StateFOUNDATION DETAILSS210 - S211GENERAL NOTESELEVATION DATUMDESIGN SPECIFICATIONSEARTHWORKCONCRETE”””COLD-FORMED METAL FRAMINGPOST-INSTALLED ANCHORS“”PRE-ENGINEERED STEEL BUILDING STRUCTURES100GENERALSTRUCTURAL DATASPECIAL INSPECTIONSMEZZANINE PLAN & DETAILSS300 SHEET KEYNOTE LEGENDREVISIONSEquipmentShare5710 Bull Run Rd.Columbia, MO 65201ARCHITECTCONSTRUCTIONCIVILSTRUCTURALMEPTier 4 5710 Bull Run Dr. Columbia, MO 65201 EquipmentShareDeVFriptionDateS200FOUNDATION PLANFOUNDATION PLANNNOTE:HAIRPIN KEY℄℄℄℄ SHEET KEYNOTE LEGENDREVISIONSEquipmentShare5710 Bull Run Rd.Columbia, MO 65201ARCHITECTCONSTRUCTIONCIVILSTRUCTURALMEPTier 4 5710 Bull Run Dr. Columbia, MO 65201 EquipmentShareDeVFriptionDateS210FOUNDATIONDETAILS℄CONTINUOUS FOOTING SECTION℄NOTE:℄℄PLAN VIEW℄COLUMN FOOTING SECTIONNOTE:℄SLOPED THRESHOLD SECTION℄℄℄CONSTRUCTION JOINTCONSTRUCTION JOINTCONTRACTION JOINTNOTE:CRACK CONTROL REINFORCINGTYP. ELECTRICAL GROUNDING DETAIL @ FOOTING TYP. PLUMBING COORDINATION DETAILSTYP. FOOTING SECTION @ DOWNSPOUTTYP. THRESHOLD DETAIL @ WALK DOORS℄CONTINUOUS FOOTING SECTION℄NOTE:PLAN VIEW℄℄COLUMN FOOTING SECTIONFOOTING STEP DETAILSLAB TRANSITION SECTION℄CONT. INTERIOR FOOTING SECTION @ MEZZANINE RECESSED SLAB DETAIL SHEET KEYNOTE LEGENDREVISIONSEquipmentShare5710 Bull Run Rd.Columbia, MO 65201ARCHITECTCONSTRUCTIONCIVILSTRUCTURALMEPTier 4 5710 Bull Run Dr. Columbia, MO 65201 EquipmentShareDeVFriptionDateS211FOUNDATIONDETAILS℄℄PLAN VIEWCOLUMN FOOTING SECTION℄COLUMN FOOTING SECTION℄℄PLAN VIEW℄STEM WALL SECTIONSTEM WALL SECTIONSTEM WALL SECTIONSTEM WALL SECTION℄NOTE:℄℄PLAN VIEWCOLUMN FOOTING SECTION SHEET KEYNOTE LEGENDREVISIONSEquipmentShare5710 Bull Run Rd.Columbia, MO 65201ARCHITECTCONSTRUCTIONCIVILSTRUCTURALMEPTier 4 5710 Bull Run Dr. Columbia, MO 65201 EquipmentShareDeVFriptionDateS300MEZZANINEPLAN & DETAILSNOTE:FRAMING SECTIONFRAMING SECTIONBACK-TO-BACK HEADER DETAILFLOOR TO EXTERIOR LOAD-BEARINGWALL STUD CONNECTIONJAMB-TO-FLOOR ATTACHEMNT DETALNOTE:WALL BRIDGING DETAILWEB STIFFENER @LOAD BEARING WALL DETAILFLOOR HEADER & TRIMMER DETAILTYP. STUD WALL CORNER FRAMING SECTIONMEZZANINE FRAMING PLANN Z1Z11P1-14,16P1-10,121PAD MOUNT TRANSFORMERTELECOM PEDESTALP1-26,28GRV14432G4" SS5676" CWGM21. PROVIDE POWER AND DISCONNECT FOR SLIDING GATE OPERATOR, UP TO 1.5 HP 120/208V. PROVIDE CONDUIT AND WIRING FOR GATE CONTROLS, ENTRY KEYPAD AND/OR SENSORS AS REQUIRED. VERIFY EQUIPMENT WITH SHOP DRAWINGS AND COORDINATE WITH MANUFACTURER'S INSTALLATION REQUIREMENTS.2. SITE LIGHTING SHALL COMPLY WITH ALL LOCAL REQUIREMENTS OF THE LOCAL JURISDICTION, INCLUDING FOOTCANDLE LEVELS, MIN/MAX RATIOS, AND LIGHT SPILLAGE AT THE PROPERTY LINE. COORDINATE WITH FINAL SITE PARKING LAYOUT.3. ROUTE ALL EXTERIOR LIGHTING THROUGH LIGHTING CONTROL PANEL. EXTERIOR LIGHTING CONTROLS SHALL COMPLY WITH ADOPTED LOCAL ENERGY CODES AND ORDINANCES.4. COORDINATE LOCATION AND REQUIREMENTS FOR PAD OR POLE MOUNT TRANSFORMER, METERING EQUIPMENT, PRIMARY AND SECONDARY CONDUITS WITH LOCAL UTILITY.5. COORDINATE ROUTING OF DOMESTIC AND FIRE PROTECTION WATER PIPING, METERING REQUIREMENTS AND CONNECTIONS WITH LOCAL UTILITY.6. COORDINATE ROUTING OF SANITARY SEWER PIPING AND CONNECTIONS WITH LOCAL UTILITY.7. COORDINATE ROUTING OF GAS SERVICE WITH LOCAL UTILITY.8. PROVIDE 2" PVC CONDUIT FROM TELECOM PEDESTAL TO DEMARCATION BOX. COORDINATE LOCATION AND ROUTING WITH TELECOM UTILITY.88CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPME101ME101ME101ME101MEP SITE PLANMEP SITE PLANMEP SITE PLANMEP SITE PLANTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare3/32" = 1'-0"1111MEP Site PlanMEP Site PlanMEP Site PlanMEP Site Plan## Description Date Z1Z1YYYYY22122211P1-18,20P1-22,24P1-26,283EMERGENCY STOP PUSHBUTTON LOCATED 20-100' FROM GAS PUMPSE3FUEL ISLANDLOCATION TBDCHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPME102ME102ME102ME102SITE LIGHTING PLANSITE LIGHTING PLANSITE LIGHTING PLANSITE LIGHTING PLANTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare1" = 20'-0"1111Site Lighting PlanSite Lighting PlanSite Lighting PlanSite Lighting Plan1. ROUTE ALL EXTERIOR LIGHTING THROUGH LIGHTING CONTROL PANEL. EXTERIOR LIGHTING CONTROLS SHALL COMPLY WITH ADOPTED LOCAL ENERGY CODES AND ORDINANCES.2. WHERE PERMITTED BY LOCAL CODES, PROVIDE POLES WITH (3) FLOOD LIGHT FIXTURES AIMED AT YARD.## Description Date ABBREVIATIONSØDIAMETER AAMPABVABOVE ACAIR CONDITIONINGAC/HRAIR CHANGES PER HOUR ADDADDENDUM AFFABOVE FINISHED FLOOR AFUEANNUAL FUEL UTILIZATION EFFICIENCYALT ALTERNATE AP ACCESS PANEL ARCH ARCHITECT/ARCHITECTURAL BFF BELOW FINISHED FLOORBHPBRAKE HORSE POWER BLW BELOW BTU BRITISH THERMAL UNITS BTUH BRITISH THERMAL UNITS PER HOURCAP CAPACITY CDCEILING DIFFUSERCFM CUBIC FEET PER MINUTE CLG CEILING CON'TCONTINUEDD DEGREE DB DRY BULB DIA DIAMETERDIDWDOUBLE INLET DOUBLE WIDTH DN DOWN DXDIRECT EXPANSIONDWGDRAWINGEA EACH E/A EXHAUST AIR EAT ENTERING AIR TEMPERATUREEFFEFFICIENCY ELEC ELECTRICAL EQUIP EQUIPMENTEREXHAUST REGISTERESPEXTERNAL STATIC PRESSUREEWT ENTERING WATER TEMPERATURE EXIST EXISTINGF DEGREES FAHRENHEITFCFORWARD CURVED FD FIRE DAMPER FL FLOOR FPM FEET PER MINUTE FT FOOT, FEETFTHDFEET OF HEADFTR FIN TUBE RADIATIONFTWGFEET OF HEAD WATER GAUGE GAGAUGEGAL GALLONGALVGALVANIZED GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE HP HORSE POWER HTHEIGHTHTG HEATING HTR HEATERHUMHUMIDITY HWS HEATING WATER SUPPLY HWR HEATING WATER RETURN HZHERTZIN INCHINWCINCHES WATER COLUMNKWKILOWATTLAT LEAVING AIR TEMPERATURE LB POUND LB/HR POUNDS PER HOUR LP LOW PRESSURELVR LOUVER LWT LEAVING WATER TEMPERATURE M/A MIXED AIR MAX MAXIMUM MBH ONE THOUSAND BTU PER HOUR MCF ONE THOUSAND CUBIC FEET MD MOTORIZED DAMPER MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUSMTDMOUNTED MTR MOTOR MUA MAKE-UP AIR NC NOISE CRITERIA N.C. NORMALLY CLOSED NIC NOT IN CONTRACT NO NUMBER N.O. NORMALLY OPEN NTS NOT TO SCALE O/A OUTSIDE AIROPEROPERATOR PD PRESSURE DROP PRESS PRESSURE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE PWR POWER R/A RETURN AIR RCP RADIANT CEILING PANEL REC RECESSED REVREVISIONRGRETURN GRILLE RH RELATIVE HUMIDITY RL/A RELIEF AIR RM ROOM RPM REVOLUTIONS PER MINUTE S/A SUPPLY AIR SF SQUARE FOOT SD SMOKE DAMPER SM SURFACE MOUNT SP STATIC PRESSURESPECSPECIFICATIONSRSUPPLY REGISTERSTDSTANDARD T THERMOSTATT/ATRANSFER AIR TD TEMPERATURE DROP TEMP TEMPERATURE TYP TYPICAL VAC VACUUM VAV VARIABLE AIR VOLUME VENT VENTILATIONVFDVARIABLE FREQUENCY DRIVEVVOLTAGEW/ WITHW/OWITHOUTWB WET BULBZDZONE DAMPERABBREVIATIONS - CONTROLSAIANALOG INPUTAOANALOG OUTPUTARANALOG REGISTERBIBINARY INPUTBOBINARY OUTPUTCALCCALCULATIONCO2CARBON DIOXIDECRTLCONTROLDADISCHARGE AIRDDCDIRECT DIGITAL CONTROLDIFFDIFFERENTIALDODIGITAL OUTPUTECELECTRONICALLY COMMUTATEDENTHENTHALPYFLAFULL LOAD AMPSHRHEATING WATER RETURNHSHEATING WATER SUPPLYHWHEATING WATERPPUMPPAPRIMARY AIRPHPHASEPIDPROPORTIONAL-INTEGRAL-DERIVATIVEPOTPOTENTIOMETERPPMPARTS PER MILLIONGENERAL CONSTRUCTION NOTES1. ALL ELECTRICAL WORK SHALL CONFORM WITH LOCAL AND STATE ELECTRICAL CODES, O.S.H.A., AND THE LATEST NATIONAL ELECTRICAL CODE AND ELECTRICAL SPECIFICATIONS.2. ALL ELECTRICAL LIGHT AND POWER WIRE SHALL NOT BE SMALLER THAN #12 A.W.G. COPPER. ALUMINUM CONDUCTORS SHALL NOT BE PERMITTED. ALL SERVICE, FEEDER, AND BRANCH CIRCUIT CONDUCTORS SHALL HAVE TYPE THWN/THHN (90 DEGREE) INSULATION. LIGHTING FIXTURE WIRE INSULATION SHALL HAVE A TEMPERATURE RATING NOT LESS THAN THE INDIVIDUAL LIGHTING FIXTURE'S MANUFACTURER RECOMMENDED RATING. NON-METALLIC CABLE IS NOT PERMITTED.3. E.C. SHALL FURNISH AND INSTALL, FOR WORK DESIGNATED AS HIS RESPONSIBILITY, ALL WIRE, WIREWAY, CONDUIT, CONNECTORS, OUTLETS, ETC. NECESSARY TO ACHIEVE A COMPLETE ELECTRICAL INSTALLATION. WHERE AN ELECTRICAL DEVICE IS REQUIRED BY CODE BUT NOT SHOWN, IT SHALL BE FURNISHED AND INSTALLED BY E.C. AS THOUGH FULLY SHOWN AND SPECIFIED.4. THE TERM "E.C." IN THESE NOTES REFERS TO THE ELECTRICAL SUBCONTRACTOR.5. ELECTRICAL CONTRACTOR SHALL COORDINATE THIS WORK WITH THE MECHANICAL CONTRACTOR.6. ELECTRICAL CONNECTION TO ALL EQUIPMENT SUPPLIED BY OTHERS SHALL BE THE RESPONSIBILITY OF THE E.C. UNLESS OTHERWISE NOTED.7. COORDINATE WIRING OF THERMOSTATS WITH THE MECHANICAL SUBCONTRACTOR.8. COORDINATE NEW ELECTRICAL SERVICE WITH LOCAL UTILITY PROVIDER:9. CONTRACTOR SHALL INCLUDE IN BID ALL UTILITY CHARGES TO PROJECT.GENERAL MECHANICAL SYMBOLSREVISION NUMBER -SHOWN ON PLANSPOINT WHERE NEW CONNECTS TO EXISTINGOR EXISTING SEPARATES FROM DEMOLISHEDDETAIL NUMBER ON SHEETSHEET NUMBER WHERE DETAIL APPEARSKEYNOTECONTINUATION SYMBOLITEMS TO DEMOLISHEDPIPING TO BE DEMOLISHEDAREA NOT IN CONTRACTPIPE SIZE/SYSTEM TAG (DIAMETER)ABOVE GROUND PIPINGPIPE SLOPE TAG (STEAM PIPING)EXISTING PIPE TAGSQUARE DUCT/SYSTEM TAG (WIDTH X HEIGHT)OVAL DUCT/SYSTEM TAG (WIDTH / HEIGHT)ROUND DUCT/SYSTEM TAG (DIAMETER)RECTANGULAR SUPPLY/OUTSIDE AIR DUCT RISEROUND SUPPLY/OUTSIDE AIR DUCT RISERECTANGULAR RETURN/TRANSER AIR DUCT RISEROUND RETURN/TRANSER AIR DUCT RISERECTANGULAR EXHAUST DUCT AIR DUCT RISEROUND EXHAUST DUCT AIR DUCT RISEBALANCE DAMPERFIRE RATED DAMPER12"x8" S/ADROP12"/8" S/A12"Ø S/ADROPDROPDROPDROPDROPGRILLES, REGISTERS & DIFFUSERS TAGAIR DEVICEXX"xXX"XX#CFM2" HWS1/8" / 12" SLOPE#NECK SIZEAIR DEVICE TAG#XX####E(XX)GENERAL SPECIFICATIONS1. ALL WORK SHALL BE DONE IN STRICT CONFORMANCE WITH THE LOCAL BUILDING CODES. 2. ALL MATERIALS SHALL BE NEW, FIRST CLASS, AND INSTALLED TO MANUFACTURER'S WRITTEN SPECIFICATIONS. 3. ALL SYSTEMS SHALL BE COMPLETE AND OPERABLE IN EVERY WAY. 4. GUARANTEE ALL WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM FINAL ACCEPTANCE. PROVIDE FIVE YEAR AIR CONDITIONING COMPRESSOR WARRANTY. 5. INSPECT JOB SITE PRIOR TO BIDDING TO DETERMINE EXACT JOB REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION DETAILS. 6. ARCHITECTURAL DRAWING DIMENSIONS SHALL GOVERN IN ALL CASES. COORDINATE ENGINEERING DRAWINGS WITH ARCHITECTURAL DRAWINGS FOR ALL EQUIPMENT LAYOUTS AND LOCATIONS. 7. LAYOUTS AND ROUTINGS SHOWN ON THE PLANS ARE APPROXIMATE AND GENERAL IN NATURE. 8. CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND UNDERSTANDING ALL DRAWINGS AND ASPECTS OF THE PROJECT SCOPE, AND FOR INCLUDING IN HIS BID ALL WORK ASSOCIATED WITH HIS TRADE, REGARDLESS OF WHICH DRAWING OR SHEET IT IS SHOWN ON. 9. COORDINATE WORK WITH ALL OTHER TRADES. EACH SUBCONTRACTOR SHALL REVIEW ENTIRE DRAWING SET AND AVOID CONFLICTS WITH OTHER TRADES. 10. REPRESENTATIVES FROM APPLICABLE TRADES SHALL BE AVAILABLE FOR BAS, PLC, MECHANICAL AND FIRE ALARM SYSTEMS VALIDATION, COMMISSIONING AND TESTING. 11. REPRESENTATIVES FROM APPLICABLE TRADES SHALL ASSIST EQUIPMENT MANUFACTURERS WITH SET-UP, TESTING, AND CLEAN-UP ACTIVITIES. 12. REFER TO ARCHITECTURAL CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.EQUIPMENT1. EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY APPROVED BY OSHA. 2. INSTALL EQUIPMENT WHILE MAINTAINING CLEARANCES AS RECOMMENDED BY MANUFACTURER AND REQUIRED BY APPLICABLE CODES AND STANDARDS. 3. PROVIDE CONNECTIONS IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND APPLICABLE CODES AND STANDARDS. COORDINATE CONNECTION REQUIREMENTS FOR FINAL EQUIPMENT SELECTIONS WITH OTHER AFFECTED TRADES. 4. VERIFY FINAL CONNECTION SIZES WITH OWNER PROVIDED EQUIPMENT AND PROVIDE REQUIRED ISOLATION VALVES, CHECK VALVES, UNIONS, GAUGES, AND SO FORTH FOR A COMPLETE INSTALLATION. 5. PROVIDE ENGRAVED PLASTIC LAMINATE NAMEPLATES ON [ALL][AFFECTED] NEW [AND EXISTING] EQUIPMENT. SURVEY BUILDING TO ENSURE THAT NAMES ARE UNIQUE AND CONSISTENT WITH EXISTING CONVENTIONS. MECHANICAL SPECIFICATIONS1. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE MECHANICAL SYSTEMS INDICATED. 2. OBTAIN ALL PERMITS, FEES, LICENSES, INSPECTIONS, AND CERTIFICATES OF COMPLIANCE OR APPROVAL AS REQUIRED BY THE AUTHORITIES.3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES, AND REGULATION SO THE GOVERNMENTAL BODIES HAVING JURISDICTION OVER THE SITE. 4. COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS AS NECESSARY TO INSTALL ALL NEW MECHANICAL SYSTEMS WITHIN THE CONFINES OF THE SPACES AVAILABLE AND WITHOUT INTERFERENCES. 5. PLANS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF WORK. DETAILS OF INSTALLATION COVERED BY CODE AND OTHER MINOR ITEMS NOT SHOWN SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES AND ACCEPTABLE INDUSTRY STANDARDS. ALL MECHANICAL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES AND MANUFACTURER'S INSTRUCTIONS. CONTRACTOR SHALL SITE VERIFY EXISTING CONDITIONS. 6. DURING CONSTRUCTION, ALL EQUIPMENT, PIPE, DUCT, ETC. SHALL BE COVERED, PLUGGED, OR CAPPED AS REQUIRED TO KEEP CLEAN AND UNDAMAGED. ALL DAMAGED ITEMS SHALL BE RESTORED TO ORIGINAL CONDITION OR REPLACED. ALL PROTECTIVE COVERINGS SHALL BE REMOVED BEFORE FINAL ACCEPTANCE. 7. PROVIDE ALL CUTTING AND PATCHING OF WALLS, FLOORS, CEILINGS, AND ROOFS AS NEEDED TO INSTALL MECHANICAL SYSTEMS. PATCHING WORK SHALL INCLUDE METHODS AND MATERIALS NEEDED FOR AFFECTED SURFACES TO MATCH ADJACENT AREAS. SEAL AROUND ALL EXTERIOR WALL PENETRATIONS WEATHER-TIGHT. 8. COORDINATE ALL ROOFING WORK WITH OWNER OR RESPONSIBLE PARTY, SO THAT ROOF WARRANTY WILL BE MAINTAINED. 9. FIELD SUPPORT ALL MECHANICAL SYSTEM EQUIPMENT AND MATERIALS FROM STRUCTURE. 10. CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE. 11. OPERATION AND MAINTENANCE MANUALS: A. DURING THE COURSE OF CONSTRUCTION, COLLECT AND COMPILE OPERATING INSTRUCTIONS, WIRING, DIAGRAMS, CATALOG CUTS, LUBRICATION AND PREVENTATIVE MAINTENANCE INSTRUCTIONS, PARTS LISTS, ETC. FOR ALL EQUIPMENT FURNISHED UNDER THIS CONTRACT. B. ALL LITERATURE AND INSTRUCTION SHIPPED WITH THE EQUIPMENT SHALL BE SAVED FOR INCLUSION IN THE OPERATION AND MAINTENANCE MANUALS. C. ALL LITERATURE LISTED ABOVE AND ALL PAPERS LISTING WARRANTIES, ETC. SHALL BE BOUND IN A 3-RING BINDER AND LABELED WITH THE PROJECT NAME, ADDRESS, ARCHITECT, ENGINEER, CONTRACTORS, ETC. 12. MANUFACTURERS, MODEL NUMBERS, ETC. INDICATES OR SCHEDULED ON THE DRAWINGS SHALL BE INTERPRETED AS HAVING ESTABLISHED A STANDARD OF QUALITY AND SHALL NOT BE CONSTRUCTED AS LIMITING COMPETITION, ARTICLES, FIXTURES, ETC., OF EQUAL QUALITY BY MANUFACTURERS SHALL BE ACCEPTABLE, SUBJECT TO STRUCTURAL AND ELECTRICAL CONSTRAINTS OF THE PROJECT DESIGN, UNLESS NOTED OTHERWISE. 13. CONDENSATE DRAIN PIPING TO BE FIELD ROUTED TO NEAREST DRAIN RECEPTACLE. REFER TO PLUMBING SHEETS FOR WASTE/VENT PIPING AND LOCATIONS. 14. MECHANICAL PIPING: A. SOME PIPING MAY HAVE BEEN SHOWN OFFSET FOR CLARITY. B. PROVIDE OFFSETS AND TRANSITIONS AS NECESSARY TO AVOID OBSTRUCTIONS. C. FIELD VERIFY EXACT ROUTING OF PIPING. MOUNT PIPING FROM STRUCTURE ABOVE AS HIGH AS POSSIBLE UNLESS NOTED OTHERWISE. ROUTE PIPING PARALLEL OR PERPENDICULAR TO BUILDING LINES. D. USE CLEVIS-STYLE HANGERS TO SUPPORT PIPING EVERY 6'-0" WITH INSULATION PROTECTION SHIELDS AND ALL-THREAD RODS FROM STRUCTURE ABOVE, NOT FROM OTHER PIPING, DUCTWORK, CONDUIT, AND SO FORTH. DO NOT SUPPORT OTHER PIPING, CEILING GRID, DUCTWORK, CONDUIT, AND SO FORTH FROM PIPING. E. PROVIDE DIELECTRIC CONNECTIONS BETWEEN FERROUS AND NONFERROUS PIPING. F. PROPERLY DISPOSE OF ALL REFRIGERANT IN ACCORDANCE WITH EPA 40 CFR 82.SUBSTITUTIONS AND SUBMITTALS1. DESIGN DOCUMENTS WERE BASED UPON INDICATED, SCHEDULED AND SPECIFIED PRODUCTS. WHILE SUBSTITUTIONS MAY BE ACCEPTED, ANY CHANGES, POSSIBLY BORNE BY OTHER TRADES, THAT BECOME NECESSARY AS A RESULT OF THE SUBSTITUTION AND THE ASSOCIATED COSTS SHALL BE FULLY BORNE BY THE CONTRACTOR AND MUST BE INCLUDED IN THEIR BID. 2. SUBSTITUTION REQUESTS MUST BE HIGHLIGHTED IN BID AND CLEARLY IDENTIFIED AS SUBSTITUTIONS. SUBMIT RFI TO ARCHITECT IF PROPOSED SUBSTITUTION REQUIRES ARCHITECTURAL CHANGES TO ACCOMMODATE SUBSTITUTION AND ITS WORKING CLEARANCES. 3. PROVIDE SUBMITTALS FOR ALL EQUIPMENT, DEVICES, MATERIALS, AND SO FORTH IN ACCORDANCE WITH DIVISION 01 SPECIFICATIONS OF THE CONTRACT DOCUMENTS.4. SHOP DRAWINGS, SAMPLES, AND COORDINATION DRAWINGS: THE CONTRACTOR SHALL SUBMIT FOR APPROVAL, ELECTRONIC COPIES OF MANUFACTURER'S SHOP DRAWINGS FOR ALL MAJOR ITEMS OF EQUIPMENT TO BE FURNISHED UNDER THIS CONTRACT, AND ALL MAJOR ITEMS REQUIRING COORDINATION BETWEEN CONTRACTORS. BEFORE SUBMITTING SHOP DRAWINGS AND MATERIAL LISTS, THE CONTRACTOR SHALL VERIFY THAT ALL THE EQUIPMENT IS COMPATIBLE AND SUITABLE FOR INTENDED USE, FITS THE AVAILABLE SPACE AND ALLOW AMPLE ROOM FOR MAINTENANCE. THE ENGINEER'S CHECKING AND SUBSEQUENT APPROVAL OF SUCH SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN DIMENSIONS, DETAILS, SIZE OF MEMBERS, QUANTITIES, OMISSIONS OF COMPONENTS OR FITTINGS, OR FOR COORDINATING ITEMS WITH ACTUAL BUILDING CONDITIONS. THE CONTRACTOR SHALL PROCEED WITH THE PROCUREMENT AND INSTALLATION OF EQUIPMENT/MATERIAL ONLY AFTER RECEIVING APPROVED SHOP DRAWINGS RELATIVE TO EACH ITEM. 5. ACCEPTANCE OF THE WORK SHALL BE SUBJECT TO THE ENGINEERS APPROVAL OF SHOP DRAWINGS, PRODUCT DATA AND SAMPLES. SHOP DRAWINGS SHALL INCLUDE MANUFACTURERS DETAIL DRAWINGS OF EQUIPMENT AND MATERIAL, AND CONTRACTORS SHOP DETAILS FOR INSTALLATION OF MATERIAL AND EQUIPMENT. DESCRIPTIVE LITERATURE SHALL INCLUDE CATALOG DATA COVERING DESIGN, SIZE AND CAPACITY OF MATERIAL AND EQUIPMENT. SUBMITTALS SHALL INCLUDE THE MANUFACTURERS MODEL NUMBER, CAPACITY, PERFORMANCE DATA, ELECTRICAL CHARACTERISTICS, AND SO FORTH, ALL CLEARLY SHOWN AND MARKED FOR THE SPECIFIC ITEM OF EQUIPMENT BEING FURNISHED ON THIS PROJECT. 6. RECORD DRAWINGS: THE CONTRACTOR SHALL KEEP DAY-TO-DAY RECORD OF ALL CHANGES OR VARIATIONS MADE FROM THE CONTRACT DOCUMENTS AND AT THE END OF THE PROJECT SHALL PROVIDE THE OWNER, ARCHITECT AND ENGINEER WITH REPRODUCIBLE SETS AS REQUESTED. 7. DEMONSTRATION AND TRAINING: CONTRACTOR SHALL PROVIDE OWNER WITH INSTRUCTIONAL TRAINING PROGRAM ON ALL MAJOR EQUIPMENT ITEMS PROVIDED AND INSTALLED UNDER CONTRACT. TRAINING SHALL BE PROVIDED BY A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE. THE TRAINING SESSION SCHEDULE SHALL BE COORDINATED WITH OWNER AND OWNER'S OPERATIONS TO MINIMIZE DISRUPTING OWNER'S OPERATIONS. CONTRACTOR TO PROVIDE A TRAINING SESSION FOR EACH WORK SHIFT TO ENSURE ALL EMPLOYEES HAVE THE OPPORTUNITY TO ATTEND THE TRAINING DURING THEIR NORMAL WORK HOURS (COORDINATE REQUIRED NUMBER OF WORK SHIFTS WITH OWNER).TESTING, BALANCE AND ADJUSTMENT1. DUCTWORK AND PIPING SHALL BE BALANCES BY QUALIFIED PERSONNEL WHO HAVE PREVIOUS EXPERIENCE WITH BALANCING PROCEDURES AND ARE FAMILIAR WITH TESTING AND BALANCING PROCEDURES OF THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). CERTIFIED TAB PROFESSIONAL IS NOT REQUIRED. 2. BALANCING SHALL INCLUDE THE BALANCING OF THE EQUIPMENT AND AIR DISTRIBUTION SYSTEMS TO PROVIDE DESIGN QUANTITIES INDICATED AND VERIFICATIONS OF PERFORMANCE OF ALL EQUIPMENT AND AUTOMATIC CONTROLS.CONTROL WIRING SPECIFICATIONS1. ELECTRICAL WIRING AND WIRING CONNECTIONS NEEDED FOR THE INSTALLATION OF MECHANICAL SYSTEMS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR UNLESS OTHERWISE INDICATED. 2. INSTALL CONTROL WIRING, WITHOUT SPLICES BETWEEN TERMINAL POINTS, COLOR CODED. INSTALL IN NEAT, WORKMANLIKE MANNER, SECURELY FASTENED. INSTALL IN ACCORDANCE WITH APPLICABLE NATIONAL ELECTRICAL CODE EDITION AND THE ELECTRICAL SPECIFICATIONS. 3. INSTALL VOLTAGE CIRCUITS LOCATED IN CONCRETE SLAB AND MASONRY WALLS, OR EXPOSED IN OCCUPIED AREAS, IN ELECTRICAL CONDUIT. ALL WIRING IN AREAS NOT USED FOR AIR MOVEMENT SHALL BE IN ELECTRIC METALLIC TUBING EXCEPT LOW VOLTAGE WIRING MAY BE IN APPROVED SIGNAL CABLE WHERE APPROVED BY LOCAL CODES.DUCT AND DUCT INSULATION SPECIFICATIONS1. ALL INSULATIONS, DUCT LINING AND ACCESSORIES SHALL HAVE A FIRE HAZARD CLASSIFICATION WITH A FLAME SPREAD RATING OF NOT OVER 25, A FUEL CONTRIBUTION RATING OF NOT OVER 50, AND A SMOKE DEVELOPED RATING OF NOT HAVE 50, IN ACCORDANCE WITH NFPA STANDARDS. 2. DUCT LINING: MIN. 1" THICK, 2 LB/CF, AIR STREAM SIDE COATED, INSTALL PER SMACNA STANDARDS. 3. DUCT COVERING: 2" THICK, 3/4 LB/CF, FIBERGLASS BLANKET WITH FACTORY APPLIED VAPOR BARRIER AND FACING, INSTALL PER SMACNA STANDARDS. 4. RIGID DUCT AND DUCT FITTINGS: A. FABRICATED FROM GALVANIZED SHEET STEEL IN ACCORDANCE WITH SMACNA STANDARDS, LATEST EDITION, FOR 2" WATER GAUGE STATIC PRESSURE. B. SEAL ALL DUCTWORK JOINTS WITH NON-HARDENING, NON-MIGRATING MASTIC SEALANT, AS RECOMMENDED FOR SEALING SEAMS AND JOINTS IN DUCTWORK. 5. FLEXIBLE DUCT: TECHNAFLEX SERIES WK OR EQUAL. FACTORY APPLIED INSULATION AND VAPOR BARRIER, 1-1/2" THICK, MAXIMUM 6'-0 ” LENGTH. 6. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS. 7. PROVIDE FLEXIBLE CONNECTION BETWEEN DUCTWORK AND MECHANICAL EQUIPMENT ITEMS. 8. RECTANGULAR DUCT SIZES SHOWN ARE ACTUAL REQUIRED INTERIOR DUCT SIZES AND DO NOT INCLUDE ALLOWANCE FOR DUCT LINER OR INSULATION WHERE APPLICABLE. 9. DUCTWORK SHALL BE BALANCED BY A QUALIFIED BALANCING PROFESSIONAL. 10. ALL NEW DUCTWORK SHALL BE INSULATED AND SEALED AT JOINTS IN ACCORDANCE WITH THE APPLICABLE EDITION OF THE INTERNATIONAL ENERGY CONSERVATION CODE. CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.REVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPM000M000M000M000MECHANICAL NOTES,MECHANICAL NOTES,MECHANICAL NOTES,MECHANICAL NOTES,SSSSPPPPEEEECCCCIIIIFFFFIIIICCCCAAAATTTTIIIIOOOONNNNSSSS,,,, AAAANNNNDDDD LLLLEEEEGGGGEEEENNNNDDDDSSSSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare# Description Date TTT TT TJ234BA678195WEF11,2WEF21,2HVLS1HVLS2HVLS3RH1RH2159522X28L1154522X26L2154522X26L2154522X26L23'-0 AFF3'-0 AFF3'-0 AFF3'-0 AFFRH3RH4111112M1021CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPM101M101M101M101HVAC PLANSHVAC PLANSHVAC PLANSHVAC PLANSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare1/8" = 1'-0"1111HVAC PlanHVAC PlanHVAC PlanHVAC Plan#1. PROVIDE COMBUSTION AIR INTAKE / FLUE UP THROUGH ROOF PER MANUFACTURER'S INSTRUCTIONS.2. DIGITAL WALL CONTROLLER FOR HVLS FANS 1&2.# Description Date TT TJ78WH1F1F2GRV114"x14"10"x10"12"x12"12"x12"18"x14"8"ø14"x14"44BA789F1F244016x10S2406ØS421010ØS1506ØE11006ØE1806ØS41408ØS32008ØS32008ØS350010X10R3706ØS4806ØS41408ØS3109018X18R41006ØE1EF1THERMOSTAT. SEE SERVER FAN DETAILSHEET M501 FOR DETAILS1508ØE26"ø6"x8"6"ø10"x10"10"x8"8"x8"10"x10"10"x8"12"x12"10"ø6"ø6"ø12"x12"8"x10"8"ø8"ø6"ø8"x10"10"x10"18"x14"1408X8R1706ØS4456ØS61408X8R124010X10R344016x10S226012X8S51’−6"8"x8"EF26"ø8"x8"8"ø6"ø8"ø8"ø111" CDGRV11,21" CD25014X14L38"ø10"x8"8"ø12"x12"26012X8R214"x14"14"x14"8"ø445333WHR1CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPM102M102M102M102EEEENNNNLLLLAAAARRRRGGGGEEEEDDDD HHHHVVVVAAAACCCC PPPPLLLLAAAANNNNSSSSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare1/4" = 1'-0"2222HVAC Plan HVAC Plan HVAC Plan HVAC Plan ---- MezzanineMezzanineMezzanineMezzanine1. 1" CONDENSATE DOWN THRU MEZZANINE FLOOR TO CEILING SPACE BELOW.2. 1" CONDENSATE DOWN IN WALL TO DRAIN INTO MOP SINK.3. DIRECT VENT PIPING. ROUTE UP TO CONCENTRIC VENT KIT AND THRU ROOF. COORDINATE WITH AND LOCATE MIN. 10'-0 HORIZONTALLY FROM GRV-1 OUTSIDE AIR INTAKE.4. 8" OA OFF TOP OF RETURN DUCT. ROUTE TO MOTORIZED DAMPER AND MANUAL BALANCE DAMPER AS SHOWN.5. 10" OA UP TO GRV-1 ON ROOF.## Description Date1/4" = 1'-0"1111HVAC Plan HVAC Plan HVAC Plan HVAC Plan ---- EnlargedEnlargedEnlargedEnlarged 90° ELBOW"T" BRANCH(SUPPLY)"T" BRANCH(RETURN)"T" BRANCH(SUPPLY)"T" BRANCH(RETURN)TURNING VANESVOLUME DAMPER212222211112NOTE: SEE FLOOR PLAN FOR DIMENSIONSMOVABLE PERIMETER ANGLE FRAMEBREEZEWAY FANREAR GUARDWALL SLEEVEANGLE SUPPORTGRAVITYBACKDRAFTDAMPEROUTSIDE WALLWEATHER HOODINLINE FANMIN. 3/8" THREADED RODSUPPORTED FROM STRUCTURE ABOVEVIBRATION ISOLATOR WHERE REQUIRED BY SPEC. (TYP.)DOUBLE NUTS & WASHERS ON THREADED ROD (TYP.)TRANSITION AS REQUIRED BOTH INLET & OUTLET DUCTSFLEX CONNECTION (TYP.)DUCT LINER WHEREREQUIRED BY SPEC.TLOUVERED DOORDUCT ABOVE LAY-IN CEILING TO RETURN DUCTEXHAUST FAN (CFM PER SCHEDULE)120V COOLING ONLYTHERMOSTAT SET @ 90°FPROVIDED BY HVAC CONTRACTORWIRED BY ELECTRICIANSERVER ROOMCORRIDORHARD CEILINGSUSPENDED CEILING= INSULATIONDUCTWORK INSIDE THERMAL ENVELOPEINSULATION SCHEDULETYPE OF DUCTWORK½" LINER1" LINER1½" WRAP2" WRAPINSULATIONRECTANGULAR SUPPLYRECTANGULAR RETURNRECTANGULAR EXHAUSTRECTANGULAR OUTSIDE AIRROUND SUPPLYROUND RETURNROUND EXHAUSTROUND OUTSIDE AIRSPIRAL SUPPLYSPIRAL RETURNSPIRAL EXHAUSTSPIRAL OUTSIDE AIRXXXXXX30° MAX.4" MIN.3'-0" MAX.DUCT "A" x (CFM "C" / CFM "A") = "C" "B" = (CFM "B" / CFM "A") x DUCT "A"DUCT "A"CFM "A"DUCT "B"CFM "B"ADECCENTRIC TRANSITIONPROPORTIONAL FITTINGREGULAR VOLUME DAMPER(SEE DETAIL)FLEXIBLE AIR DUCTWORK.MAXIMUM LENGTH 8'-0".MAXIMUM SAG 1/2" PER FOOT OF SUPPORT SPACING.MIN. BEND INSIDE RADIUS = 1 DUCT DIA.MIN. 1" WIDE SUPPORT STRAPS.SUPPORTS MUST NOT DAMAGE DUCTOR CAUSE OUT OF ROUND SHAPESUPPLY DIFFUSER(SEE INSTALLATION DETAIL)45° ENTRY WITH DAMPERTURNING VANES IN ALL TEES, ELBOWS, OR CHANGES IN DIRECTION(ALTERNATE: PROVIDE LOND RADIUS ELBOW)FIRE DAMPER IF INDICATED THUSACCESS DOOR LOCATED NEAR FIRE DAMPER, IF INDICATEDWALLFRDSUPPLYDUCT UP.CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.REVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPM501M501M501M501MECHANICAL DETAILSMECHANICAL DETAILSMECHANICAL DETAILSMECHANICAL DETAILSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShareNOT TO SCALE1111DUCTWORK FITTINGS DETAILDUCTWORK FITTINGS DETAILDUCTWORK FITTINGS DETAILDUCTWORK FITTINGS DETAILNOT TO SCALE2222WALL MOUNTED EXHAUST FAN DETAILWALL MOUNTED EXHAUST FAN DETAILWALL MOUNTED EXHAUST FAN DETAILWALL MOUNTED EXHAUST FAN DETAILNOT TO SCALE3333ININININ----LINE FAN INSTALL DETAILLINE FAN INSTALL DETAILLINE FAN INSTALL DETAILLINE FAN INSTALL DETAILNOT TO SCALE4444SERVER ROOM FAN DETAILSERVER ROOM FAN DETAILSERVER ROOM FAN DETAILSERVER ROOM FAN DETAILNOT TO SCALE5555TYP. DUCT INSULATION DETAILTYP. DUCT INSULATION DETAILTYP. DUCT INSULATION DETAILTYP. DUCT INSULATION DETAILNOT TO SCALE6666TYPICAL DUCTWORK DETAILTYPICAL DUCTWORK DETAILTYPICAL DUCTWORK DETAILTYPICAL DUCTWORK DETAIL# Description Date CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.REVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPM601M601M601M601MMMMEEEECCCCHHHHAAAANNNNIIIICCCCAAAALLLL SSSSCCCCHHHHEEEEDDDDUUUULLLLEEEESSSSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShareEXHAUST FAN SCHEDULEMARK MANUFACTURERMODELNUMBERSERVINGAIRFLOW(CFM)EXT. S.P.(IN-WG)MOTOR ELECTRICALDIMENSIONS (IN.)OPERATINGWEIGHT(LBS)NOTESDRIVE HP VOLTS/PHASE MCA MOCPEF-1 SOLER & PALAU TD-150S OFFICES 150 0.375 DIRECT 1/10 120/1 1 15 19X10X8 13 1,2EF-2 SOLER & PALAU TD-150S IT CLOSET 250 0.375 DIRECT 1/10120/1 1 15 19X10X8 13 1,2WEF-1 JENCO GED14-1/2 WASH BAY 1595 0.375 DIRECT 1/2 208/1 515 20X20X12 55 1,2WEF-2 JENCO LC24-1-E SHOP 4640 0.375 BELT 1 208/3 4 15 30X30X23 200 1,2DIFFUSER, REGISTER, AND GRILLE SCHEDULEMARK MANUFACTURER MODEL DESCRIPTIONCONNECTIONSIZE (IN.)MOUNTING DAMPER FINISH NOTESE1 PRICE 80 12x12 EGG CRATE EXHAUST GRILLE 6Ø T-BAR NO WHITEE2 PRICE 80 12x12 EGG CRATE EXHAUST GRILLE 8Ø T-BAR NO WHITEL1 POTTORFF EXA-645-MD COMBINATION LOUVER/DAMPER, 120 V 22X28 EXTERIOR NOCOLORSELECTED BYARCHITECTWITH PROVINGSWITCHL2 POTTORFF EXA-645-MD EXTERIOR WALL LOUVER, 120 V 22X24 EXTERIOR NOCOLORSELECTED BYARCHITECTWITH PROVINGSWITCHL3 POTTORFF EDD-445 EXTERIOR WALL LOUVER, 120 V 14X14 EXTERIOR NOCOLORSELECTED BYARCHITECTWITH PROVINGSWITCHR1 PRICE PDDR 24x24 PERFORATED LAY-IN RETURN DIFFUSER 8X8 T-BAR NO WHITER2 PRICE 520 12x6 DOUBLE DEFLECTION SUPPLY GRILLE 12X8 GYP NO WHITER3 PRICE PDDR 24x24 PERFORATED LAY-IN RETURN DIFFUSER 10X10 T-BAR NO WHITER4 PRICE PDDR 24x24 PERFORATED LAY-IN RETURN DIFFUSER 18X18 T-BAR NO WHITES1 PRICE SPD 24x24 PLAQUE DIFFUSER - LAY-IN 10Ø T-BAR NO WHITES2 PRICE 520 12x6 DOUBLE DEFLECTION SUPPLY GRILLE 16X10GYP YES WHITES3 PRICE SPD 24x24 PLAQUE DIFFUSER - LAY-IN 8Ø T-BAR NO WHITES4 PRICE SPD 24x24 PLAQUE DIFFUSER - LAY-IN 6Ø T-BAR NO WHITES5 PRICE 520 12x6 DOUBLE DEFLECTION SUPPLY GRILLE 12X8 GYP YES WHITES6 PRICE SPD 12x12 PLAQUE DIFFUSER - LAY-IN 6Ø T-BAR NO WHITEHVLS FAN SCHEDULEMARKDIAMETER(FT)BASIS OF DESIGNAREASERVEDMOTOR ELECTRICAL OPERATINGWEIGHT(LBS)NOTESMANUFACTURER MODEL DRIVE HP VOLTS MCA MOCPHVLS-1 10 MACROAIR MY10-0100-MA-2083-MA SHOP GEAR 1 208/3 10.8 15 178 1HVLS-2 14 MACROAIR MY14-0100-MA-2083-MA SHOP GEAR 1 208/3 10.8 15 195 1HVLS-3 10 MACROAIR MY10-0100-MA-2083-MA SHOP GEAR 1 208/3 10.8 15 178 1GAS FURNACE SCHEDULEMARK DESCRIPTION TONS CFMOA AIRFLOWMAXOA AIRFLOWMINHEATING (NATURAL GAS) ELECTRICALOPERATINGWEIGHT(LBS)NOTESKBTU IN KBTU OUT VOLTAGEMCA(AMPS)MOCP(AMPS)F-1 FURNACE - HORZ 3 1050 200 CFM 200 80 76 120 11 20 155 1-5F-2 FURNACE - HORZ 4 1500 170 CFM 100 80 76 120 11 20 120 1-5SPLIT SYSTEM CONDENSING UNIT SCHEDULEMARK DESCRIPTION TONSEQUIPMENTSERVEDCOOLING (80/67 DB/WB) ELECTRICALOPERATINGWEIGHT(LBS)NOTESKBTU SEN KBTU TOT VOLTAGEMCA(AMPS)MOCP(AMPS)CU-1 CONDENSING UNIT 3 F-1 24.0 34.0 208/1 20 A 30 A 185 1,2,3CU-2 CONDENSING UNIT 3 F-2 33.0 46.0 208/1 24 A 40 A 185 1,2,3NOTES:- THE HVAC CONTRACTOR IS REQUIRED TO SEND THE ELECTRICIAN A COPY OF SUBMITTAL DATA, CLEARLY INDICATING THE ELECTRICAL REQUIREMENTS FOR ALL HVAC EQUIPMENT. THIS MUST BE SENT WITHIN 1 WEEK OF RECEIPT OF SUBMITTAL APPROVAL. 1. INLINE EXHAUSTER WITH BACKDRAFT DAMPER AND SPEED CONTROLLER2. SIDEWALL PROPELLER TYPE WITH SPEED CONTROLLER BACKDRAFT RAIN HOOD AND BIRDSCREEN.ELECTRIC HEATER SCHEDULEMARK DESCRIPTIONBASIS OF DESIGNAIRFLOWCFMELECTRICALDIMENSIONS(LxWxH)OPERATINGWEIGHT(LBS)NOTESMANUFACTURER MODEL VOLTS MCA MOCPWHR-1 ELECTRIC WALL HEATER BERKO FRA1512F 100 115 12.5 20 4X15X19 25 1INTAKE VENTILATOR SCHEDULEMARK AREA SERVED MANUFACTURER MODEL CFMPRESSURE DROP(IN. WC)THROAT AREA(FT²)MOUNTINGFAN TYPEREMARKSGRV-1 OUTSIDE AIR JENCO RCXII-I-12 300 0.03 0.9ROOFTOPINTAKE1,2NOTES:- THE HVAC CONTRACTOR IS REQUIRED TO SEND THE ELECTRICIAN A COPY OF SUBMITTAL DATA, CLEARLY INDICATING THE ELECTRICAL REQUIREMENTS FOR ALL HVAC EQUIPMENT. THIS MUST BE SENT WITHIN 1 WEEK OF RECEIPT OF SUBMITTAL APPROVAL. 1. MATCH ARCHETECTURAL COLOR SCHEME. REFER TO ARCHETECTURAL DRAWINGS FOR FURTHER INFORMATION.2. PROVIDE GRAVITY BACKDRAFT DAMPER AND BIRDSCREEN.NOTES:- THE HVAC CONTRACTOR IS REQUIRED TO SEND THE ELECTRICIAN A COPY OF SUBMITTAL DATA, CLEARLY INDICATING THE ELECTRICAL REQUIREMENTS FOR ALL HVAC EQUIPMENT. THIS MUST BE SENT WITHIN 1 WEEK OF RECEIPT OF SUBMITTAL APPROVAL.1. BALL VALVE AND STAINLESS STEEL FLEX GAS CONNECTOR.2. 4", 16GA. HEAT TREATED ALUMINIZED STEEL COMBUSTION CHAMBERS AND RADIANT PIPE.3. POLISHED ALUMINUM REFLECTORS WITH END CAPS - HIGH EFFICIENT - 100% REFLECTION (NOTE: ADD SIDE WALL REFLECTORS WHERE HEATERS ARE PLACED ALONG A WALL).4. 24V DIGITAL TOUCH SCREEN 2-STAGE 7-DAY PROGRAMMABLE THERMOSTATS.5. TOTALLY ENCLOSED BURNER CABINET, FAN CAN NOT BE OUTSIDE OF BURNER BOX.6. 4" FITTED OUTSIDE COMBUSTION AIR COLLAR WITH KIT (FLEX HOSE AND CLAMPS).7. HANGING CHAIN SETS (CHAIN, KARABINER CLIPS, BEAM CLAMPS, EYE BOLTS).8. U-BEND PACKAGE9. WASH BAY RATED HEATERS: STAINLESS STEEL BURNER CABINETS, STAINLESS STEEL REFLECTORS, STAINLESS STEEL SIDE WALL REFLECTORS, CORROSION RESISTANT ALUMINIZED STEEL TUBING, WATERTIGHT (NEMA4X) 2-STAGED WASH BAY THERMOSTAT).10. WARRANTY: 3 YEARS ON ALL PARTS AND 10 YEARS ON TUBES, REFLECTORS AND BURNER EQUIPMENT.RADIANT TUBE HEATER SCHEDULEMARKBASIS OF DESIGNAREA SERVED CONFIGURATIONNATURAL GASHEAT (MBH)ELECTRICALOPERATINGWEIGHT(LBS)LENGTH NOTESMANUFACTURER MODELHIGHFIRELOWFIREVOLTSMCA(AMPS)MOCP(AMPS)RH-1 ADVANCED RADIANT SYSTEMS DU175-U60 SHOP BAY 1,2 U-TUBE 175 130 120 1.0 15 300 32' 6" 1-8, 10RH-2 ADVANCED RADIANT SYSTEMS DU175-U60 SHOP BAY 3 U-TUBE 175 130 120 1.0 15 300 32' 6" 1-8, 10RH-3 ADVANCED RADIANT SYSTEMS DUH100-S20 WASH BAY STRAIGHT TUBE 100 75 120 1.0 15 125 21'-11" 1-2, 5-7, 9-10RH-4 ADVANCED RADIANT SYSTEMS DUH100-S20 WASH BAY STRAIGHT TUBE 100 75 120 1.0 15 125 21'-11" 1-2, 5-7, 9-10NOTES:- THE HVAC CONTRACTOR IS REQUIRED TO SEND THE ELECTRICIAN A COPY OF SUBMITTAL DATA, CLEARLY INDICATING THE ELECTRICAL REQUIREMENTS FOR ALL HVAC EQUIPMENT. THIS MUST BE SENT WITHIN 1 WEEK OF RECEIPT OF SUBMITTAL APPROVAL.1. 13.4 SEER2 MINIMUM EFFICIENCY.2. LOW AMBIENT CONTROLS TO 0°F.3. HAIL GUARDS.NOTES:- THE HVAC CONTRACTOR IS REQUIRED TO SEND THE ELECTRICIAN A COPY OF SUBMITTAL DATA, CLEARLY INDICATING THE ELECTRICAL REQUIREMENTS FOR ALL HVAC EQUIPMENT. THIS MUST BE SENT WITHIN 1 WEEK OF RECEIPT OF SUBMITTAL APPROVAL.1. HONEYWELL #TH8320R1003 (VISIONPRO 8000) PROGRAMMABLE THERMOSTAT, SET TO RUN FAN CONTINUOUSLY DURING OCCUPIED HOURS.2. 90%+ EFFICIENCY, CONDENSING FURNACE WITH CORROSION-PROOF CONDENSATE DRAIN PAN, AND LIFETIME HEAT EXCHANGER WARRANTY.3. MOTORIZED OUTSIDE AIR DAMPER.4. CO2 DETECTOR - HONEYWELL #C7232A, 24V, WALL OR DUCT MOUNTED TO OPEN & CLOSE MOTORIZED OUTSIDE AIR DAMPER TO PROVIDE FRESH AIR AMOUNTS AS REQURIED BY CO2 LEVELS. SET OA DAMPER MAX/MIN POSITION TO AMOUNTS SHOWN. OTHER UNITS SHALL BE BALANCED TO FLOWS SHOWN ON PLAN.5. FILTER SHALL BE SIZED FOR LOW VELOCITY (300 FPM) AT FULL CFM INDICATED.NOTES:- THE HVAC CONTRACTOR IS REQUIRED TO SEND THE ELECTRICIAN A COPY OF SUBMITTAL DATA, CLEARLY INDICATING THE ELECTRICAL REQUIREMENTS FOR ALL HVAC EQUIPMENT. THIS MUST BE SENT WITHIN 1 WEEK OF RECEIPT OF SUBMITTAL APPROVAL.1. WITH WALL MOUNT DIGITAL CONTROLLER 4 TO CONTROL UP TO 4 FANS.NOTES:- THE HVAC CONTRACTOR IS REQUIRED TO SEND THE ELECTRICIAN A COPY OF SUBMITTAL DATA, CLEARLY INDICATING THE ELECTRICAL REQUIREMENTS FOR ALL HVAC EQUIPMENT. THIS MUST BE SENT WITHIN 1 WEEK OF RECEIPT OF SUBMITTAL APPROVAL.1. WITH SURFACE MOUNT FRAME, THERMOSTAT, INTEGRAL DISCONNECT.# Description Date SSSSSNO2COCONO2JJJJ234BA678195P1CTGTBEMCU2CU1P2P2-32,34P2-28,30P2-27,29,31P2-33,35,37P1-13,15,17P2-51,53,55P2-21,23,25P2-39,41,43P2-15,17,19P2-9,11,13MTSWEF1WEF2P2-63,65,67P2-57,59,6111111111223445+44BREAKROOMBREAKROOMBREAKROOMBREAKROOM105105105105PARTS &PARTS &PARTS &PARTS &SERVICESERVICESERVICESERVICEOFFICEOFFICEOFFICEOFFICE108108108108IT CLOSET/IT CLOSET/IT CLOSET/IT CLOSET/STORAGESTORAGESTORAGESTORAGE110110110110LOBBYLOBBYLOBBYLOBBY113113113113WOMEN'SWOMEN'SWOMEN'SWOMEN'S106106106106MEN'SMEN'SMEN'SMEN'S111111111111MEN'SMEN'SMEN'SMEN'S103103103103MECH/ELECMECH/ELECMECH/ELECMECH/ELECROOMROOMROOMROOM104104104104CONFERENCECONFERENCECONFERENCECONFERENCE/ TRAINING/ TRAINING/ TRAINING/ TRAINING112112112112GENERALGENERALGENERALGENERALMANAGERMANAGERMANAGERMANAGER107107107107PARTSPARTSPARTSPARTSCAGECAGECAGECAGE109109109109+44+44+44+44+44WASH BAYWASH BAYWASH BAYWASH BAY102102102102+72+72+72+72P2-44P2-46P2-56P2-48P2-58P2-50P2-60P2-52P2-62P2-54P2-66P2-70P2-36,38P2-40,4222P1-43P1-40P1-33P1-41P1-44P1-44 P1-37P1-44P1-31P1-42P1-45P2-74P2-64P2-68P2-72P1-19P1-38P1-39HVLS3HVLS2HVLS1P2-2,4,6P2-14,16,18P2-8,10,12P2-76RH2RH1P2-24,26PW1WP1P2-20,22EQUIPMENTEQUIPMENTEQUIPMENTEQUIPMENTROOMROOMROOMROOM102.1102.1102.1102.1P3P2-45,47,491P1-7,9,11P1-21RH3RH4P2-79P2-80P2-81P2-82SP1P2-8397866FC2FC16LCP2P2-8411P2-8411P2-841111P2-84LCP1P1-30WPP1-44P1-6,8 P1-2,4GENERAL ELECTRICAL NOTES1. ALL WORK SHALL CONFORM WITH THE MOST CURRENT NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES AND ORDINANCES AND O.S.H.A. WHERE MINIMUM CODE REQUIREMENTS ARE EXCEEDED BY THE REQUIREMENTS INDICATED IN THE SPECIFICATIONS AND ON THESE DRAWINGS, THE DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE. (IN THE CASE OF CODE CONFLICT DIRECTION SHALL BE TAKEN FROM THE MORE STRICT OF THE CONFLICTING CODES).2. CAREFULLY REVIEW CONTRACT DOCUMENTS INCLUDING DRAWINGS & PROJECT MANUAL. INFORMATION REGARDING WORK OF THE VARIOUS TRADES & SUBCONTRACTORS ARE DISPERSED THROUGHOUT THE DOCUMENTS & CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE FULL SET OF DOCUMENTS. CONTRACTOR SHALL COORDINATE INSTALLATION OF UTILITIES TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OF THE MECHANICAL, PIPING, ETC. CONDUIT & PIPE TO BE RUN TO MAXIMIZE USE OF CEILING SPACE FOR USE BY OTHER TRADES. 3. CONDUIT ROUTES SHOWN ARE DIAGRAMMATIC ONLY. CONTRACTOR SHALL FIELD VERIFY AND PROVIDE CONDUIT ROUTES AS REQUIRED. CONTRACTOR IS RESPONSIBLE FOR ROUTING ALL CONDUITS NOT SHOWN ON THE DRAWINGS, INCLUDING BUT NOT LIMITED TO CONDUITS SHOWN ON THE ONE-LINE AND CONTROL DIAGRAMS AS WELL AS HOME RUNS SHOWN ON THE PLAN DRAWINGS. CONDUITS SHALL BE ROUTED AS DEFINED IN THE SPECIFICATIONS. 4. AT THE CONCLUSION OF THIS PROJECT PROVIDE AN UPDATED TYPEWRITTEN, AS-BUILT DIRECTORY INSIDE EACH PANELBOARD/SWITCHBOARD PROPERLY IDENTIFYING EACH CIRCUIT USED & THE SPECIFIC LOAD SERVED. ALSO PROVIDE SCHEDULES ON CD DISK.5. FIELD VERIFY EXACT LOCATION OF ALL FLOOR PENETRATIONS PRIOR TO ROUGH-IN INSTALLATION.6. OPENINGS SHALL BE CUT TO THE EXACT SIZE REQUIRED IN ORDER TO MAINTAIN ANY MATERIAL RATINGS AND SEALED TO MAINTAIN RATING. PROVIDE ALL NECESSARY FLOOR CUTTING/PENETRATIONS AND ALL OF THE RE-PATCHING FOR THE COMPLETE EXECUTION OF THIS WORK.7. ALL EXIT AND EMERGENCY LIGHTS SHALL BE CONNECTED TO AN UN-SWITCHED CIRCUIT SERVING THE SAME AREA.8. CONCEAL ALL ELECTRICAL WIRING AND RACEWAYS WHERE CONSTRUCTION PERMITS. EXPOSED RACEWAY SHALL BE MINIMIZED WHERE STRUCTURE IS EXPOSED TO VIEW. WHERE NECESSARY, CAREFULLY INSTALL RACEWAYS PARALLEL TO WALLS, BEAMS AND COLUMNS. EXPOSED RACEWAY SHALL BE HELD TIGHT TO STRUCTURE & LOCATED SO AS TO KEEP IT AS INCONSPICUOUS AS POSSIBLE.9. PROVIDE FIRESTOPPING TO MAINTAIN FIRE RATINGS AT ALL PENETRATIONS OF RATED CONSTRUCTION.10. ALL SPARE WIRES SHALL BE TAPED AND COILED.11. COORDINATE ALL DEVICES AND WIRING WITH EQUIPMENT NAMEPLATE DATA. VERIFY THE ELECTRICAL LOADS, MOUNTING HEIGHTS AND NEMA CONFIGURATIONS WITH THE PLUMBING AND OTHER CONTRACTORS AND SUPPLIERS PRIOR TO ROUGH-IN.12. PROVIDE FINAL CONNECTION, WIRING, HOOK-UP, ETC. FOR ALL EQUIPMENT AND CONTROLS REQUIRING ELECTRICAL POWER TO OPERATE. 13. FURNISH AND INSTALL ALL WIRE, WIREWAY, CONDUIT, CONNECTORS, OUTLETS, ETC, NECESSARY TO ACHIEVE A COMPLETE AND WORKING INSTALLATION.14. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH A PULL WIRE OR STRING.15. ALL ELECTRICAL DEVICES IN PUBLIC AREAS SHALL BE MOUNTED PER A.D.A. REQUIREMENTS.16. ALL EXTERIOR MOUNTED ELECTRICAL DEVICES AND EQUIPMENT SHALL BE IN WEATHERPROOF ENCLOSURE AND U.L. LISTED FOR WET LOCATION AND/OR UL/NEMA 3R LISTED U.N.O.17. CONTRACTOR SHALL REFER TO ARCHITECTS DETAILS AND ELEVATIONS FOR COORDINATION OF LOCATION OF ALL WIRING DEVICES BEFORE ROUGH-IN OF J-BOXES.18. NO "PIGGYBACK" BREAKERS SHALL BE ALLOWED.19. ALL SINGLE-PHASE CIRCUITS SHALL HAVE A DEDICATED NEUTRAL CONDUCTOR.20. ALL FEEDERS SHALL HAVE A SEPARATE COPPER GROUNDING CONDUCTOR INSTALLED. IN NO CASE SHALL THE CONDUIT OR RACEWAY BE USED AS THE GROUNDING CONDUCTOR.21. ALL ELECTRICAL LIGHTING WIRE SHALL NOT BE SMALLER THAN #12A.W.G. TIN-PLATED COPPER WIRE.22. ALUMINUM CONDUCTORS SHALL NOT BE PERMITTED.23. NON-METALLIC CABLE IS NOT PERMITTED.24. COLOR AND MATERIAL FOR ALL SWITCHES, AND COVER PLATES SHALL BE SELECTED BY ARCHITECT.25. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ROUTING ALL CONDUITS NOT SHOWN ON THE PLANS. THIS SHALL INCLUDE ALL CONDUITS SHOWN ON THE ONE-LINES AND HOMERUNS SHOWN ON THE PLAN DRAWINGS. CONDUITS SHALL BE ROUTED AS INDICATED ON THE DRAWINGS AND DEFINED IN THE SPECIFICATIONS.26. INSTALL ANY / ALL CORD SETS SUPPLIED WITH THE EQUIPMENT.27. MOUNT DISCONNECT SWITCHES AND COMBINATION STARTERS AT 65" AFF. TO TOP OF ENCLOSURE UNLESS OTHERWISE INDICATED.28. IF EQUIPMENT SUPPLIED BY MANUFACTURER HAS A LARGER LOAD THAN VALUE SHOWN, THE CABLE CONDUIT AND ELECTRICAL EQUIPMENT SHALL BE ENLARGED, AS REQUIRED, TO ACCOMMODATE THE HIGHER VALUEELECTRICALLY HELD, 120 VAC, 30 AMP, 4 POLE CONTINUOUS DUTY CONTACTOR120V COILWEF-1"FC1"L-1LN120VCO120V CARBONMONOXIDE DETECTOR EQUAL TO MACURCO #CM-12WALL SWITCHNO224V NITROGEN DIOXIDEDETECTOR EQUAL TO MACURCO #TX-6-ND120V TO 24V TRANSFORMER120V CONTACTORWITH 24V CONTROL COILWEF-1WEF-1P2P2P2P2ELECTRICALLY HELD, 120 VAC, 30 AMP, 4 POLE CONTINUOUS DUTY CONTACTOR120V COILWEF-2"FC2"L-2LN120VCO120V CARBONMONOXIDE DETECTOR EQUAL TO MACURCO #CM-12WALL SWITCHNO224V NITROGEN DIOXIDEDETECTOR EQUAL TO MACURCO #TX-6-ND120V TO 24V TRANSFORMER120V CONTACTORWITH 24V CONTROL COILWEF-2WEF-2P2P2P2P2ABBREVIATIONSACABOVE COUNTER AFFABOVE FINISHED FLOORAFGABOVE FINISHED GRADEDISPDISPOSALDWGDRAWING ECELECTRICAL CONTRACTOR EXISTEXISTING FACPFIRE ALARM CONTROL PANELGC GENERAL CONTRACTOR GFCIGROUND FAULT CIRCUIT INTERRUPTERGFIGROUND FAULT INTERRUPTERGNDGROUNDEDKVAKILOVOLTKWKILOWATT MDPMAIN DISTRIBUTION PANELM.L.O.MAIN LUGS ONLYN.E.C.NATIONAL ELECTRICAL CODENTSNOT TO SCALEPNLPANELBOARD S/ESERVICE ENTRANCE LISTED LABELEDTYPTYPICAL U.N.O.UNLESS NOTED OTHERWISE WPWEATHERPROOF ELECTRICAL SYMBOLSHATCH AND 'E' DENOTES EMERGENCY FIXTURERECESSED CEILING MOUNTED LIGHT FIXTURESSURFACE CEILING MOUNTED LIGHT FIXTURESLED STRIP FIXTUREWALL MOUNTED LIGHT FIXTURECEILING MOUNTED EXIT LIGHTWALL MOUNTED EXIT LIGHTEXIT LIGHT. ARROW INDICATES THE DIRECTION THE CHEVRON POINTS. IF WALL MOUNTED -CENTERLINE 90" AFF. UNO.EMERGENCY LIGHT FIXTURE WITH BATTERY BACKUP. MOUNT 90" AFF TO CENTERLINE U.N.O.SINGLE POLE WALL SWITCH -42" AFF U.N.O., "a" INDICATES ZONE.3-WAY WALL SWTCH -42" AFF U.N.O.DIMMER WALL SWITCH -42" AFF U.N.O.WALL MOUNTED OCCUPANCY SENSOR SWITCH -42" AFF U.N.O.CEILING MOUNTED OCCUPANCY SENSOROCD3OCDUPLEX CONVENIENCE RECEPTACLE -18" AFF UNOGFCI RECEPTACLEWEATHERPROOF GFCI RECEPTACLE FOURPLEX CONVENIENCE RECEPTACLE -18" AFF UNODUPLEX RECEPTACLE -CEILING MOUNTEDDUPLEX RECEPTACLE -FLOOR MOUNTEDSPECIAL PURPOSE RECEPTACLEJUNCTION BOXTELEPHONE OUTLET -18" AFF UNODATA OUTLET -18" AFF UNOCABLE TELEVISION OUTLET -18" AFF UNOCARD READERFIRE ALARM HORN-STROBEFIRE ALARM STROBEPOWER/LIGHTING PANELBOARDDISTRIBUTION PANEL OR MAIN SWITCH GEARDISCONNECT SWITCHCOMBINATION MAGNETIC MOTOR STARTERMOTORCONTACTORTHERMOSTATTIME SWITCHWPJCRTCTSFFFFCLGCHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPE101E101E101E101POWER PLANSPOWER PLANSPOWER PLANSPOWER PLANSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare1/8" = 1'-0"1111Power PlanPower PlanPower PlanPower Plan1. PROVIDE POWER AND DISCONNECT FOR 208V 3Ø ROLL-UP DOOR OPERATOR. PROVIDE CONDUIT AND WIRING FOR DOOR CONTROLS AS REQUIRED. MOUNT CONTROLLER AT 4'-0" A.F.F. ON RIGHT SIDE OF DOOR. VERIFY EXACT LOCATION OF OPERATOR AND CONTROLS AND COORDINATE WITH MANUFACTURER'S INSTALLATION REQUIREMENTS.2. PROVIDE CORD DROP WITH NEMA 6-50P RECEPTACLE FOR PORTABLE WELDING EQUIPMENT. COORDINATE EXACT LOCATION(S).3. PROVIDE POWER AND DISCONNECT FOR AIR COMPRESSOR. VERIFY 10 HORSEPOWER, 480V 3Ø. PROVIDE 120V RECEPTACLE FOR REFRIGERATED AIR DRYER.4. RECESSED CONCRETE FLOOR BOX WITH SEPARATE POWER & DATA COMPARTMENTS, EQUAL TO WIREMOLD RFB6 WITH INTEGRAL RECEPTACLE, RJ45 COMMUNICATION BRACKET AND NICKEL FLUSH COVER ASSEMBLY. ROUTE (2) 3/4" CONDUIT FOR POWER & DATA UP IN ADJACENT WALL TO ABOVE ACCESSIBLE CEILING.5. COORDINATE EXACT LOCATIONS OF RECEPTACLE(S) FOR IT EQUIPMENT AND WALL MOUNTED NETWORK RACK(S).6. PROVIDE VEHICLE GARAGE EXHAUST FAN CONTROL SYSTEM WITH CONTACTOR INTERLOCKED WITH NITROUS DIOXIDE AND CARBON MONOXIDE SENSORS. PROVIDE CONNECTIONS TO EXHAUST FAN AND MOTORIZED DAMPERS ON INTAKE LOUVER(S). PROVIDE WALL SWITCH FOR NORMAL FAN OPERATION. REFER TO EXHAUST FAN CONTACTOR WIRING DETAIL AND COORDINATE WITH HVAC EQUIPMENT.7. PROVIDE NEMA 3R DISCONNECT FOR WASH WATER PROCESSING EQUIPMENT. COORDINATE LOCATION AND ELECTRICAL REQUIREMENTS WITH EQUIPMENT VENDOR. 8. PROVIDE NEMA 3R DISCONNECT FOR PRESSURE WASHING EQUIPMENT. COORDINATE LOCATION AND ELECTRICAL REQUIREMENTS WITH EQUIPMENT VENDOR.9. PROVIDE NEMA 3R DISCONNECT FOR SUMP PUMP IN WASH BAY PIT. PROVIDE SWITCH IN EQUIPMENT ROOM OR CONNECT TO WASH WATER PROCESSING EQUIPMENT AS REQUIRED FOR INTERMITTENT OPERATION. COORDINATE REQUIREMENTS WITH EQUIPMENT VENDOR.#NOT TO SCALE2222Exhaust Fan Contactor FC1 Detail Exhaust Fan Contactor FC1 Detail Exhaust Fan Contactor FC1 Detail Exhaust Fan Contactor FC1 Detail ---- WEFWEFWEFWEF----1111NOT TO SCALE3333Exhaust Fan Contactor FC2 Detail Exhaust Fan Contactor FC2 Detail Exhaust Fan Contactor FC2 Detail Exhaust Fan Contactor FC2 Detail ---- WEFWEFWEFWEF----2222# Description Date DDOOJJJJJ J JOSOSSDDOOCOCSSSSSSJ234BA678195D DD DD DD DDAEEWPWPWPWPWPWPEE111AA AA AAA A AAA AA AAAAA A AWPWPWPWPWPP PP P111D DD DD DD DDD DD DD DD DDD DD DD DD DDWPCCCCCCCCCCCCCH H HKWPWPE1E1MMMMMMMMMMP2-78P2-77P2-75P2-73P1-25P1-25P1-27P1-27P1-27P2-713333355P2-69P2-693352T25P1-29Level 1100'-0"Roof124'-0"Level 1100'-0"Roof124'-0"112Level 1100'-0"Roof124'-0"Level 1100'-0"Roof124'-0"WPWPWPWPWPWPWP12T2CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPE102E102E102E102LIGHTING PLANSLIGHTING PLANSLIGHTING PLANSLIGHTING PLANSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare1/8" = 1'-0"1111Lighting PlanLighting PlanLighting PlanLighting Plan1/8" = 1'-0"2222ELEVATION ELEVATION ELEVATION ELEVATION ---- EASTEASTEASTEAST#1/8" = 1'-0"3333ELEVATION ELEVATION ELEVATION ELEVATION ---- SOUTHSOUTHSOUTHSOUTH1. JUNCTION BOX(ES) AND WIRING FOR LIGHTED SIGNS. COORDINATE EXACT LOCATION(S) TO CONCEAL BOXES BEHIND EACH LIGHTED AREA OF THE SIGNS. SEE ELEVATIONS. ROUTE WIRING THROUGH LIGHTING CONTROL PANEL.2. PROVIDE RGB COLOR CHANGING LED TAPE LIGHTING, ROUTED ALONG THE ROOF OVERHANG. COORDINATE INSTALLATION WITH SOFFIT CONSTRUCTION. PROVIDE JUNCTION BOX(ES) AND POWER FOR DRIVERS AND CONTROLS AS REQUIRED. ROUTE WIRING THROUGH LIGHTING CONTROL PANEL. 3. PROVIDE TOGGLE SWITCHES FOR EACH SHOP LIGHTING CIRCUIT. WHERE REQUIRED BY LOCAL ENERGY CODES, ROUTE ALL SHOP LIGHTING THROUGH LIGHTING CONTROL PANEL RELAY TO PROVIDE TIME-SWITCH CONTROLS DURING OCCUPIED HOURS. PROVIDE MOMENTARY OVERRIDE SWITCH TO ENABLE 2-HOUR TIME EXTENSION.4. WHERE REQUIRED BY LOCAL ENERGY CODES, ROUTE LOBBY LIGHTING CIRCUITS THROUGH LIGHTING CONTROL PANEL RELAY TO PROVIDE TIME-SWITCH CONTROL DURING OCCUPIED HOURS. PROVIDE MOMENTARY OVERRIDE SWITCH TO ENABLE 2-HOUR TIME EXTENSION.5. ROUTE EXTERIOR LIGHTING CIRCUITS THROUGH LIGHTING CONTROL PANEL RELAYS FOR TIMED CONTROL. SEE LIGHTING CONTROL PANEL WIRING DETAIL.# Description Date PAD-MOUNT UTILITYTRANSFORMER208Y/120V 3PHMCT METER PER LOCAL UTILITY REQUIREMENTS#1/0 CU GROUNDING ELECTRODE CONDUCTOR. SEE DETAIL FOR GROUNDING REQUIREMENTS.PANEL 'P1'120/208V, 3PH400A MB,84 CKTTHRU-FEEDLUGSPANEL 'P2'120/208V, 3PH400A MLO,84 CKTCT CABINETPER LOCALUTILITYREQUIREMENTSMTS208Y/120V400ADOUBLE-THROWSAFETYSWITCHGENERATORTAPBOX4 #500MCM, 4" C. 4 #500MCM, #3 EQ. GND, 4" C.4 #500MCM,4" C. 4 #500MCM, #3 EQ. GND, 4" C.COORDINATE TRANSFORMER LOCATION AND INSTALLATION REQUIREMENTS WITH LOCAL UTILITYCOORDINATE PRIMARY CONDUIT ROUTING AND INSTALLATION REQUIREMENTS WITH LOCAL UTILITY4 #500MCM, #3 EQ. GND, 4" C.PANEL 'P3'120/208V, 3PH100A MLO,24 CKT100ASHUNT4 #3, #8 EQ. GND, 1-1/4" C.SHUNT-TRIP BREAKER CONNECTED TO FUEL ISLAND EMERGENCY STOP MINIMUM 8'-0" LONG⅝"⌀GROUND RODGROUND ROD(REQUIRED)BUILDING STEEL(REQUIRED)WATER PIPE(REQUIRED)METAL WATER PIPE BURIEDIN A MINIMUM OF 10'-0" OF EARTHWITHIN 5'-0" OF ENTRANCEINTO BUILDINGCONCRETE-ENCASEDELECTRODE(REQUIRED)GROUNDING RING(IF AVAILABLE)GROUNDINGBUSNEUTRALSERVICEENTRANCEEQUIPMENTBONDING JUMPERSIZE PER RISERSYSTEM BONDINGTELEPHONE / DATATERMINAL BOARD(S)OTHER SYSTEMS 94PER NEC 250-92(b)BOND OTHER PIPINGSYSTEMS & STRUCTURALSTEEL PER NEC 250.104BOND LIGHTINGPROTECTION SYSTEMSPER NEC 250.106WALL MOUNTED GROUNDING BARCOPPER BUS BAR (¼" x 4" x 20")w/ INSULATORS AND MOUNTING BRACKETSERITECH # EGB14420CC GROUND BARALL CONNECTIONS SHALL BE 2-HOLE LONG BARREL CONNECTION LUGSSIZE PER RISER. INSULATED WIRING INSTALLED OPEN UNLESSINSTALLED IN NONMETALLIC PVC CONDUIT TO PROTECT IT FROM SVERE DAMAGEGROUNDING ELECTRODE CONDUCTOR (GEC) SIZED PER RISERLCP1PARKING LOT POLE LIGHTSEXTERIOR SIGN LIGHTSRELAY ( TYP.)LIGHTING CONTROL PANEL EQUAL TO WATTSTOPPER MODEL LC81/2 NORELAY #OVERRIDEOPERATIONAL SCHEDULE3/45678NOYESLIGHTING CONTROL PANEL SCHEDULEPANEL NO. - LCP1MS1NOTE:• LIGHTING CONTROL PANEL SHALL PROVIDE A WARNING FLASH 2 MINUTES BEFORE INTERIOR LIGHTS TURN OFF.• MOMENTARY SWITCH SHALL PROVIDE 2 HOUR OVERRIDE DURING UNOCCUPIED HOURS FOR RELAYS SCHEDULED TO HAVE AN OVERRIDE SWITCH.MOMENTARY OVERRIDE SWITCH EQUAL TO WATTSTOPPER #DCC212345678OCCUPIED HOURSDUSK TO MIDNIGHTEXTERIOR BUILDING LIGHTINGYES OCCUPIED HOURSLCP2WALLPACKSCOVERED CHARGING LIGHTSRELAY ( TYP.)LIGHTING CONTROL PANEL EQUAL TO WATTSTOPPER MODEL LC81/2 NORELAY # OVERRIDE OPERATIONAL SCHEDULE345678YESLIGHTING CONTROL PANEL SCHEDULEPANEL NO. - LCP2MS1NOTE:• LIGHTING CONTROL PANEL SHALL PROVIDE A WARNING FLASH 2 MINUTES BEFORE INTERIOR LIGHTS TURN OFF.• MOMENTARY SWITCH SHALL PROVIDE 2 HOUR OVERRIDE DURING UNOCCUPIED HOURS FOR RELAYS SCHEDULED TO HAVE AN OVERRIDE SWITCH.12345678SPARESHOP LIGHTSYESSHOP LIGHTSSHOP LIGHTSSHOP LIGHTSNOYESYESEXHAUST FANSLOBBY LIGHTSYARD FLOOD POLE LIGHTSDUSK TO MIDNIGHTNONODUSK TO MIDNIGHTDUSK TO MIDNIGHTMOMENTARY OVERRIDE SWITCH EQUAL TO WATTSTOPPER #DCC2DUSK TO MIDNIGHTDUSK TO MIDNIGHTOCCUPIED HOURSOCCUPIED HOURSOCCUPIED HOURSOCCUPIED HOURSA/CD/CP2SHUNT TRIPP3SEALING FITTING MUSTBE FIRST FITTINGABOVE GRADE (TYP.)NONMETALLIC RIGID CONDUIT ALLOWED IF 2'-0" MIN. BURY.ALL CONDUIT & FITTINGS LESS THAN 2'-0" BURY & ABOVE GRADETO BE RIGID METALLIC (NEC 514-8)WIRING GUTTERSAS REQUIREDSIGN LABELED "EMERGENCY GAS PUMP SHUT OFF"EMERGENCY DISCONNECT SWITCH CONNECTED TO SHUNT-TRIP BREAKER(LOCATED 20-100 FEET FROM DISPENSING UNITS)SEALING FITTINGS MUST BE USED AT BOTH ENDS OFANY CONDUIT PASSING THRU ANY CLASS 1 AREA (NEC 514-6)ALL WIRING IN CLASS 1 AREAS TO BE THWN OR TW TYPE.GROUNDING: ALL METALLIC RACEWAY COMPONENTS & EQUIPMENT MUST BE BONDED TO AN EQUIPMENT GROUND WIRE (NEC 514-16) AND MUST COMPLY WITH NEC SECTION 501CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.REVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPE601E601E601E601EEEELLLLEEEECCCCTTTTRRRRIIIICCCC DDDDEEEETTTTAAAAIIIILLLLSSSS AAAANNNNDDDDSCHEDULESSCHEDULESSCHEDULESSCHEDULESTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShareNOTES:Welding38000 VA 70.00% 26600 VAReceptacle30134 VA 66.59% 20067 VATotal Estimated Demand Current:362 AHVAC22541 VA 100.00% 22541 VATotal Connected Current:417 ALighting6600 VA 125.00% 8250 VATotal Estimated Demand:130,474 VAMotor53034 VA 100.00% 53034 VATotal Connected Load:150,295 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Connected Load:54,322 VA 50,198 VA 45,774 VATotal Connected Current:458.4 A 424.0 A 381.5 A83SPARE20 1 0 0 1 20 SPARE8481SPARE20 1 0 0 1 20 SPARE8279SPARE20 1 0 0 1 20 SPARE8077SPARE20 1 0 0 1 20 SPARE7875SPARE20 1 0 0 1 20 SPARE7673SPARE20 1 0 0 1 20 SPARE7471SPARE20 1 0 0 1 20 SPARE7269SPARE20 1 0 0 1 20 SPARE7067SPARE20 1 0 0 1 20 SPARE6865SPARE20 1 0 0 1 20 SPARE6663SPARE20 1 0 0 1 20 SPARE6461SPARE20 1 0 0 1 20 SPARE6259SPARE20 1 0 0 1 20 SPARE6057SPARE20 1 0 0 1 20 SPARE5855SPARE20 1 0 0 1 20 SPARE5653SPARE20 1 0 0 1 20 SPARE5451SPARE20 1 0 0 1 20 SPARE5249SPARE20 1 0 0 1 20 SPARE5047SPARE20 1 0 0 1 20 SPARE4845SHOP RECEPTACLES 20 1 4.5 0 1 20 SPARE4643MANAGER RECEPTACLES 20 1 7.5 7.5 1 20 RESTROOM RECEPTACLES4441BREAK ROOM RECEPTACLES 20 1 9 3 1 20 DRINKING & WASH FOUNTAINS4239IT RECEPTACLES 20 1 4.5 7.5 1 20 RECEPTACLES4037PARTS & SERVICE RECEPTACLES 20 1 12 4.5 1 20 IT RECEPTACLES3835CONFERENCE RECEPTACLES 20 1 7.5 0.8 1 20 LIGHTS3633BREAK ROOM RECEPTACLES 20 1 3 5.8 1 20 LIGHTS3431LOBBY RECEPTACLES 20 1 7.5 1.2 1 20 LIGHTS3229EXTERIOR LED COLOR STRIP 20 1 0 0 1 20 LIGHTING CONTROL PANEL LCP13027EXTERIOR SIGN LIGHTING 20 1 0 1.32825WALLPACKS 20 1 3 1.32 20 SITE LIGHTING2623LIGHTS20 1 2.6 1.82421AIR COMPRESSOR DRYER 20 1 3 1.82 20 SITE LIGHTING2219PARTS CAGE RECEPTACLES 20 1 12 1.820173.1 1.82 20 SITE LIGHTING18153.1 11.51613OVERHEAD DOOR OPENER 15 33.1 11.52 20 SLIDING GATE #2141132.3 11.512932.3 11.52 20 SLIDING GATE #1107AIR COMPRESSOR 10 HP 60 332.3 2485289.5 242 20 CONDENSING UNIT CU-263318.2 2041PANEL P2 - THRU FEED 400 3314.8 202 20 CONDENSING UNIT CU-12CKT CIRCUIT DESCRIPTIONTRIP POLESA B CPOLES TRIPCIRCUIT DESCRIPTION CKTENCLOSURE:TYPE IMODEL:MOUNTING:SURFACEWIRES:4RATING:400 AP1SUPPLY FROM:MANUAL TRANSFER SWITCHPHASES:3MAINS TYPE:MAIN BREAKERPANELBOARD LOCATION:UTILITY ROOMVOLTS:120/208 WyeA.I.C. RATING:22 kANOTES:Welding38000 VA 70.00% 26600 VAReceptacle18974 VA 76.35% 14487 VATotal Estimated Demand Current:264 AHVAC13389 VA 100.00% 13389 VATotal Connected Current:305 ALighting4050 VA 125.00% 5063 VATotal Estimated Demand:95,024 VAMotor35485 VA 100.00% 35485 VATotal Connected Load:109,898 VALoad Classification Connected Load Demand Factor Estimated Demand Panel TotalsTotal Connected Load:37,375 VA 37,784 VA 34,739 VATotal Connected Current:314.8 A 318.2 A 289.5 A83SUMP PUMP -WASH BAY PIT 3 20 1 10 0.7 1 20 MOTORIZED DAMPERS8481RADIANT HEATER 20 1 1 1 1 20 RADIANT HEATER8279RADIANT HEATER 20 1 1 1 1 20 RADIANT HEATER8077SHOP LIGHTS 20 1 5.3 5.3 1 20 SHOP LIGHTS7875SHOP LIGHTS 20 1 5.3 6 1 20 SHOP RECEPTACLES7673SHOP LIGHTS 20 1 5.3 6 1 20 SHOP RECEPTACLES7471COVERED CHARGING LIGHTS 20 1 2.7 6 1 20 SHOP RECEPTACLES7269WASH BAY LIGHTS 20 1 9.8 6 1 20 SHOP RECEPTACLES70673.2 6 1 20 SHOP RECEPTACLES68653.2 6 1 20 SHOP RECEPTACLES6663WALL EXHAUST FAN 20 33.2 6 1 20 SHOP RECEPTACLES64613.2 8.3 1 20 CHARGING STATION62593.2 8.3 1 20 CHARGING STATION6057WALL EXHAUST FAN 20 33.2 8.3 1 20 CHARGING STATION58553.1 8.3 1 20 CHARGING STATION56533.1 8.3 1 20 CHARGING STATION5451OVERHEAD DOOR OPENER 15 33.1 8.3 1 20 CHARGING STATION52493.1 8.3 1 20 CHARGING STATION50473.1 8.3 1 20 CHARGING STATION4845OVERHEAD DOOR OPENER 20 33.1 8.3 1 20 CHARGING STATION46433.1 8.3 1 20 CHARGING STATION44413.1 45.74239OVERHEAD DOOR OPENER 15 33.1 45.72 50 WELDING RECEPTACLE (NEMA 6-50P)40373.1 45.738353.1 45.72 50 WELDING RECEPTACLE (NEMA 6-50P)3633OVERHEAD DOOR OPENER 15 33.1 45.734313.1 45.72 50 WELDING RECEPTACLE (NEMA 6-50P)32293.1 45.73027OVERHEAD DOOR OPENER 15 33.1 45.72 50 WELDING RECEPTACLE (NEMA 6-50P)28253.1 44.226233.1 44.22 80 POWER WASHER 8 HP2421OVERHEAD DOOR OPENER 15 33.1 72.122193.1 72.12 80 WASH WATER PROCESSING EQUIP20173.1 10.81815OVERHEAD DOOR OPENER 15 33.1 10.816133.1 10.83 15 HVLS FAN14113.1 10.8129OVERHEAD DOOR OPENER 15 33.1 10.8107- SHUNT TRIP SPACE - -- 1 -- 10.83 15 HVLS FAN857.8 10.86310.2 10.841PANEL P3 - FUEL ISLAND - SHUNT TRIP 100 315.5 10.83 15 HVLS FAN2CKT CIRCUIT DESCRIPTIONTRIP POLESA B CPOLES TRIPCIRCUIT DESCRIPTION CKTENCLOSURE:TYPE IMODEL:MOUNTING:SURFACEWIRES:4RATING:225 AP2SUPPLY FROM:PANEL P1PHASES:3MAINS TYPE:MLOPANELBOARD LOCATION:SHOPVOLTS:120/208 WyeA.I.C. RATING:22 kALIGHTING FIXTURE SCHEDULEMARK MANUFACTURER MODELTYPE VOLTS WATTS LUMENS CCT (°K) CRI LAMPS MOUNTING REMARKSA METALUX 22EN LD2 34 UNV L835 2x2 TROFFER 120 28.5 3,4713500 90 LED RECESSEDC SATCO S11825R1 - 80-982 6" RECESSED CAN 120 13.7 1,200 3500 90 LED SURFACED METALUX OHB 15HE MFL UNV L840 HIGH BAY LED 120 80 15,000 4000 70 LED SUSPENDEDE SURE-LITES APCH7EXIT SIGN 120 0.9 - - 80 LED SURFACE REMOTE HEADS AS SHOWNE1 EXITRONIX 2RL52-BL EXTERIOR REMOTE HEAD 3.6 4LED WALLH METALUX 8SLSTP11040DD-UNV 8' LED STRIP 120 94 11,467 4000 70 LED SUSPENDEDK METALUX 4SLSTP4040DD-UNV 4' LED STRIP 120 38.9 5,210 4000 70 LED SUSPENDEDM METALUX 8VT2-LD5-16-DR-W-UNV-L840-CD1-WL 8" WET LOCATION STRIP 120 117 16,000 4000 70 LED WALL WALL MOUNT AT 7'-6" AFFP SPECTRUM CF0612PC50L35KWDD010XNLPMMB CYLINDER PENDANT 120 35 3775 3500 80 LED PENDANTTAMERICANLIGHTINGNFPROV-RGBW-98 LED FLEXIBLE NEON 120/24 914 134/FT 3000 70 LED SOFFITAPPX. 75 LINEAR FEET, WITH RGBW DMX CONTROLLER FOR ORANGEEQUIPMENT SHARE COLORWP LUMARK XTOR3B-WWALL PACK 208 26 1965 4000 70 LED WALLY LUMARK NFFLD-C40-D-UNV-33 POLE MOUNTED FLOOD LIGHT 208 384 42,339 4000 70 LED POLEZ1 MCGRAW EDISON PRV-C40-D-UNV-T4-BZ POLE LIGHT 208 131 17,087 4000 70 LED POLENOT TO SCALE1111POWER RISERPOWER RISERPOWER RISERPOWER RISERNOTES:CALCULATED DEMAND:10.9 A 3.93 kVATOTAL CONNECTED LOAD (VA):1,817 1,186 931TOTAL CONNECTED LOAD (AMPS):15.5 10.2 7.823SPARE20 1 0 0 1 20 SPARE2421SPARE20 1 0 0 1 20 SPARE2219SPARE20 1 0 0 1 20 SPARE2017SPARE20 1 0 0 1 20 SPARE1815SPARE20 1 0 0 1 20 SPARE1613SPARE20 1 0 0 1 20 SPARE1411SPARE20 1 0 0 1 20 SPARE129SPARE20 1 0 0 1 20 SPARE107FUEL ISLAND LIGHTS/RECEPTACLE 20 1 3 2.685GASOLINE PUMP 20 1 5.5 2.62 20 FUEL ISLAND HEATER635.7 5.741CLEAR DIESEL PUMP 20 25.7 5.72 20 DYED DIESEL PUMP2CKT CIRCUIT DESCRIPTIONTRIP POLESA B CPOLES TRIPCIRCUIT DESCRIPTION CKTENCLOSURE:TYPE 3RMODEL:MOUNTING:SURFACEWIRES:4RATING:100 AP3SUPPLY FROM:PANEL P2PHASES:3MAINS TYPE:MLOPANELBOARD LOCATION:COVERED CHARGINGVOLTS:120/208 WyeA.I.C. RATING:10 kANOT TO SCALE2222Grounding & Bonding DetailGrounding & Bonding DetailGrounding & Bonding DetailGrounding & Bonding DetailNOT TO SCALE3333Lighting Control Panel DetailLighting Control Panel DetailLighting Control Panel DetailLighting Control Panel DetailNOT TO SCALE4444Fuel Island Wiring DetailFuel Island Wiring DetailFuel Island Wiring DetailFuel Island Wiring Detail# Description Date EQUIPMENT ABBREVIATIONSACAIR CONDITIONING UNITACCAIR COOLED CONDENSERACCUAIR COOLING CONDENSING UNITAHUAIR HANDLING UNITASAIR SEPARATORBBOILERCHCHILLERCTCOOLING TOWERCUHCABINET UNIT HEATERCWPCONDENSER WATER PUMPCHWPCHILLED WATER PUMPDBPDOMESTIC WATER BOOSTER PUMPDCDUCT MOUNTED COILDCPDOMESTIC WATER CIRCULATING PUMPEFEXHAUST FANEDCELECTRIC DUCT COILEUHELECTRIC UNIT HEATERETEXPANSION TANKEWHELECTRIC WALL HEATERFCUFAN COIL UNITFPFIRE PUMPGIGREASE INTERCEPTORGRVGRAVITY ROOF VENTILATORHWPHEATING WATER PUMPHXHEAT EXCHANGERHRUHEAT RECOVERY UNITPRVPOWER ROOF VENTILATORRERETURN/EXHAUST FANRTUROOFTOP UNITSEPSEWAGE EJECTOR PUMPSFSUPPLY FANSPSUMP PUMPUHUNIT HEATERWHWATER HEATERABBREVIATIONSØ DIAMETER° DEGREEABV ABOVEAC AIR CONDITIONINGAD AREA DRAINADD ADDENDUMAFF ABOVE FINISHED FLOORALT ALTERNATEAP ACCESS PANELARCH ARCHITECT/ARCHITECTURALBFF BELOW FINISHED FLOORBLW BELOWBTU BRITISH THERMAL UNITSBTUH BRITISH THERMAL UNITS PER HOURCAP CAPACITYCB CATCH BASINCFM CUBIC FEET PER MINUTECLG CEILINGCO CLEAN OUTCW COLD WATERDIA DIAMETERDN DOWNDW DISTILLED WATEREA EACHEDF ELECTRIC DRINKING FOUNTAINELEC ELECTRICALEQUIP EQUIPMENTE/A EXHAUST AIREXIST EXISTING°F DEGREES FAHRENHEITFCO FLOOR CLEAN OUTFD FLOOR DRAINFL FLOORFO FUEL OILFOV FUEL OIL VENTFOR FUEL OIL RETURNFOS FUEL OIL SUPPLYFPHB FROST-PROOF HOSE BIBBFS FLOOR SINKFT FOOT/FEETG GASGAL GALLONGC GENERAL CONTRACTORGPM GALLONS PER MINUTEGW GREASE WASTEHB HOSE BIBBHP HORSE POWERHTG HEATINGHTR HEATERHW HOT WATERHWR HOT WATER RETURNHYD HYDRANTID INDIRECTIN INCHINV INVERTLB POUNDLB/HR POUNDS PER HOURLP LOW PRESSUREMAX MAXIMUMMBH ONE THOUSAND BTU PER HOURMCF ONE THOUSAND CUBIC FEETMECH MECHANICALMFR MANUFACTURERMIN MINIMUMMISC MISCELLANEOUSMTR MOTORNC NORMALLY CLOSEDNIC NOT IN CONTRACTNO NORMALLY OPENNTS NOT TO SCALEO OXYGENOD OVERFLOW ROOF DRAINPD PRESSURE DROPPIV POST INDICATOR VALVEPLBG PLUMBINGPRESS PRESSUREPR PRESSURE REGULATORPSI POUNDS PER SQUARE INCHPSIG POUNDS PER SQUARE INCH GAUGEPWR POWERRD ROOF DRAINREC RECESSEDRED REDUCERRM ROOMRPM REVOLUTIONS PER MINUTERW RAIN WATERSF SQUARE FOOTSAN SANITARYSF SQUARE FOOTSP STANDPIPESTM STEAMTDR TRENCH DRAINTEMP TEMPERATURETYP TYPICALUG UNDERGROUNDVAC VACUUMV VENTVTR VENT THROUGH ROOFW WASTEWCO WALL CLEAN OUTPLUMBING SYMBOLSCONNECT TO EXISTINGKEYNOTEITEM TO BE DEMOLISHEDPIPING TO BE DEMOLISHEDAREA NOT IN CONTRACTPIPE SIZE TAGEXISTING PIPE TAGDOMESTIC COLD WATER PIPINGSOFTENED COLD WATER PIPINGFILTERED COLD WATER PIPINGHOT WATER PIPINGHOT WATER RECIRCULATION PIPINGSANITARY PIPINGVENT PIPINGCONDENSATE DRAIN PIPINGGREASE WASTE PIPINGINDIRECT WASTE PIPINGSTORM DRAIN PIPINGOVERFLOW STORM DRAIN PIPINGSTANDARD PRESSURE NATURAL GAS PIPING? PSI MEDIUM PRESSURE NATURAL GAS PIPINGDOMESTIC WATER METERY-STRAINERBALANCING VALVECUT-OFF VALVECHECK VALVEPRESSURE REGULATORSOLENOID VALVEGAS VALVEFLOOR CLEANOUTWALL CLEANOUTFLOOR DRAINFLOOR SINKVENT THRU ROOFROOF DRAINOVERFLOW DRAINDOWNSPOUT NOZZLEWATER CLOSETURINALLAVATORYSHOWERSHOWER/TUBMOP SINKKITCHEN SINK2"E(XX)CWSWFWHWHWRSANVCDGWIDSDODGMGWULSHS/TMSSK#FCOMGENERAL PLUMBING NOTES1. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE PLUMBING SYSTEMS INDICATED.2. OBTAIN ALL PERMITS, FEES, LICENSES, INSPECTIONS, AND CERTIFICATES OF COMPLIANCE OR APPROVAL AS REQUIRED BY THE AUTHORITIES.3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES, AND REGULATION SO THE GOVERNMENTAL BODIES HAVING JURISDICTION OVER THE SITE.4. COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS AS NECESSARY TO INSTALL ALL NEW PLUMBING SYSTEMS WITHIN THE CONFINES OF THE SPACES AVAILABLE AND WITHOUT INTERFERENCES.5. PLANS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF WORK. DETAILS OF INSTALLATION COVERED BY CODE AND OTHER MINOR ITEMS NOT SHOWN SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES AND ACCEPTABLE INDUSTRY STANDARDS. ALL MECHANICAL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES AND MANUFACTURER'S INSTRUCTIONS. CONTRACTOR SHALL SITE VERIFY EXISTING CONDITIONS.6. DURING CONSTRUCTION, ALL FIXTURES, EQUIPMENT, PIPE, ETC. SHALL BE COVERED, PLUGGED, OR CAPPED AS REQUIRED TO KEEP CLEAN AND UNDAMAGED. ALL DAMAGED ITEMS SHALL BE RESTORED TO ORIGINAL CONDITION OR REPLACED. ALL PROTECTIVE COVERINGS SHALL BE REMOVED BEFORE FINAL ACCEPTANCE.7. PROVIDE ALL CUTTING AND PATCHING OF WALLS, FLOORS, CEILINGS, AND ROOFS AS NEEDED TO INSTALL MECHANICAL SYSTEMS. PATCHING WORK SHALL INCLUDE METHODS AND MATERIALS NEEDED FOR AFFECTED SURFACES TO MATCH ADJACENT AREAS. SEAL AROUND ALL EXTERIOR WALL PENETRATIONS WEATHERTIGHT. 8. COORDINATE ALL ROOFING WORK WITH OWNER OR RESPONSIBLE PARTY, SO THAT EXISTING ROOF WARRANTY (IF ANY) WILL BE MAINTAINED.9. FIELD SUPPORT ALL MECHANICAL SYSTEM EQUIPMENT AND MATERIALS FROM STRUCTURE. 10. CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE.11. SPECIFIC MODELS ARE SPECIFIED TO ESTABLISH QUALITY ONLY. SUBSTITUTIONS MAY BE MADE WITH ENGINEER'S APPROVAL.12. ARCHITECTURAL DRAWING DIMENSIONS SHALL GOVERN IN ALL CASES. COORDINATE ENGINEERING DRAWINGS WITH ARCHITECTURAL DRAWINGS FOR ALL EQUIPMENT LAYOUTS AND LOCATIONS.13. CONTRACTOR IS TO INCLUDE COSTS FOR ALL PERMITS, INSPECTIONS, TAPS, METERS & FUEL ASSOCIATED WITH HIS WORK.14. ALL SYSTEMS SHALL BE COMPLETE AND OPERABLE IN EVERY WAY. 15. CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND UNDERSTANDING ALL DRAWINGS AND ASPECTS OF PROJECT SCOPE AND FOR INCLUDING IN HIS BID ALL WORK ASSOCIATED WITH HIS TRADE, REGARDLESS OF WHICH SHEET IT IS SHOWN ON.GENERAL FIRE PROTECTION NOTES1. ALL WORK & MATERIALS SHALL BE IN COMPLIANCE WITH STATE & LOCAL CODE REQUIREMENTS. SUBCONTRACTOR SHALL OBTAIN & PAY FOR ALL PERMITS & INSPECTION FEES AS NECESSARY FOR CONSTRUCTION.2. ALL FIRE PROTECTION SYSTEMS & COMPONENTS SHALL BE IN COMPLIANCE WITH NFPA SECTIONS 13, & 24 AS WELL AS LOCAL FIRE PREVENTION REQUIREMENTS.3. FIRE SPRINKLER CONTRACTOR SHALL VERIFY WITH CURRENT NFPA THE SPRINKLER HEAD SPACING & DENSITY FOR ALL OCCUPANCY TYPES.4. SUBCONTRACTOR SHALL DO ALL NECESSARY CUTTING & PATCHING, AS WELL AS ALL NECESSARY PIPE & EQUIPMENT SUPPORTS.5. PRESSURE TEST MODIFICATIONS TO EXISTING SYSTEM & REPAIR ANY LEAKS. SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO PROPERTY & PERSONNEL CAUSED BY FAULTY INSTALLATION OR MATERIALS.6. THE SPRINKLER SUBCONTRACTOR SHALL REFER TO PLANS & MAKE ADJUSTMENTS TO NUMBER, TYPE, & LOCATION OF HEADS, TO COMPLY WITH LOCAL CODES & NEW CONSTRUCTION. HE SHALL ALSO COORDINATE HIS FINAL SHOP DRAWINGS WITH THE OTHER TRADES TO AVOID CONFLICT WITH HIS PIPING & THE LIGHTS, PIPING, CONDUITS, & DUCTWORK OF OTHER RESPECTIVE SUBCONTRACTORS ON THIS PROJECT. SHOP DRAWINGS & APPLICABLE HYDRAULIC CALCULATIONS THAT ARE SEALED BY A FIRE PROTECTION CONSULTANT & PROFESSIONAL ENGINEER SHALL BE SUBMITTED FOR OWNER'S APPROVAL FOR ALL SPRINKLER SYSTEM MODIFICATIONS.7. AS REQUIRED, FIRE STOPPING SHALL BE DONE BY METHODS REQUIRED BY LOCAL AUTHORITIES. FIRE STOP MATERIALS SHALL BE HILTI SILICONE ELASTOMER OR EQUAL.8. PROVIDE FIRE STOPPING AT ALL FLOOR & WALL PENETRATIONS.9. SUBMIT CERTIFICATION UPON COMPLETION OF FIRE PROTECTION PIPING WORK WHICH INDICATES THAT WORK HAS BEEN TESTED IN ACCORDANCE WITH NFPA 13, AND ALSO THAT THE SYSTEM IS OPERATIONAL, COMPLETE, AND WITHOUT DEFECTS.10. PROVIDE REQUIRED UNDERGROUND WATER SERVICE LINE AT THE LOCATION(S) INDICATED ON THE DRAWING. CONSULT WITH THE CITY WATER DEPARTMENT AND LOCAL AUTHORITIES WITH RESPECT TO NECESSARY MATERIALS AND LABOR TO CONFORM WITH ALL LOCAL REQUIREMENTS.11. PROVIDE FIRE DEPARTMENT CONNECTION THROUGH EXTERIOR BUILDING WALL WHERE SHOWN ON THE PLANS. COORDINATE THE EXACT LOCATION, PIPE THREADS AND FITTINGS WITH THE LOCAL FIRE DEPARTMENT TO ENSURE EXACT MATCH.12. SPRINKLER HEAD TEMPERATURE RATINGS SHALL BE APPROPRIATE FOR THE AMBIENT CONDITIONS IN THE IMMEDIATE AREAS.13. INSTALL HANGERS AND SUPPORTS FOR SPRINKLER PIPING ACCORDING TO NFPA 13. COMPLY WITH REQUIREMENTS FOR HANGER MATERIALS IN NFPA 13.GENERAL PLUMBING SPECIFICATIONS1. SOME PIPING MAY HAVE BEEN SHOWN OFFSET FOR CLARITY ON DRAWINGS.2. PROVIDE OFFSETS AND TRANSITIONS AS NECESSARY TO AVOID OBSTRUCTIONS.3. FIELD VERIFY EXACT ROUTING OF PIPING. MOUNT PIPING FROM STRUCTURE ABOVE AS HIGH AS POSSIBLE UNLESS NOTED OTHERWISE. ROUTE PIPING PARALLEL OR PERPENDICULAR TO BUILDING LINES.4. INSTALL EXPOSED DOMESTIC WATER PIPING AT HIGHEST ELEVATION POSSIBLE, UNLESS OTHERWISE INDICATED.5. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE MOUNTING AND LOCATIONS.6. BURIED EXTERIOR WASTE PIPING ELEVATION SHALL BE MINIMUM 30” BELOW GRADE. BURIED EXTERIOR DOMESTIC WATER PIPING ELEVATION SHALL BE MINIMUM 48' BELOW GRADE.7. SAW CUT EXISTING FLOOR AS REQUIRED TO INSTALL UNDERFLOOR PIPING. PATCH FLOOR TO MATCH ADJACENT FLOOR SURFACE ELEVATION. 8. NO PIPING SHALL BE ROUTED WITHIN 6'-0 OF THE TOP OF ELECTRICAL PANELS9. PERFORM EXCAVATING AND BACKFILLING IN ACCORDANCE WITH OSHA 29 CFR 1926.65110. ALL BRAZING & WELDING SHALL REQUIRE A HOT WORK PERMIT. COORDINATE ALL NECESSARY REQUIREMENTS WITH OWNER.11. USE CLEVIS-STYLE HANGERS TO SUPPORT PIPING EVERY 6'-0" WITH INSULATION PROTECTION SHIELDS AND ALL-THREAD RODS FROM STRUCTURE ABOVE, NOT FROM OTHER PIPING, DUCTWORK, CONDUIT, AND SO FORTH. DO NOT SUPPORT OTHER PIPING, CEILING GRID, DUCTWORK, CONDUIT, AND SO FORTH FROM PIPING.12. PLUMBING FIXTURES SHALL BE AS INDICATED ON DRAWING. FURNISH AND INSTALL CHROME STOP VALVES, SUPPLIES, ESCUTCHEONS AND TRAPS AS REQUIRED FOR ALL FIXTURES.13. ALL SEWER VENT TERMINATIONS SHALL BE LOCATED MINIMUM 10' HORIZONTALLY OR 3' HIGHER THAN ANY AIR INTAKE. PLUMBER IS RESPONSIBLE TO REROUTE ANY VENT TERMINATIONS AS REQUIRED TO ACCOMPLISH THIS REQUIREMENT.EQUIPMENT1. EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY APPROVED BY OSHA.2. INSTALL EQUIPMENT WHILE MAINTAINING CLEARANCES AS RECOMMENDED BY MANUFACTURER AND REQUIRED BY APPLICABLE CODES AND STANDARDS.3. PROVIDE CONNECTIONS IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND APPLICABLE CODES AND STANDARDS. COORDINATE CONNECTION REQUIREMENTS FOR FINAL EQUIPMENT SELECTIONS WITH OTHER AFFECTED TRADES.4. VERIFY FINAL CONNECTION SIZES WITH OWNER PROVIDED EQUIPMENT AND PROVIDE REQUIRED ISOLATION VALVES, CHECK VALVES, UNIONS, GAUGES, AND SO FORTH FOR A COMPLETE INSTALLATION.5. PROVIDE ENGRAVED PLASTIC LAMINATE NAMEPLATES ON ALL NEW EQUIPMENT. SURVEY BUILDING TO ENSURE THAT NAMES ARE UNIQUE AND CONSISTENT WITH EXISTING CONVENTIONS.SITE UTILITIES1. REFERENCE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING SITE UTILITIES.2. CONTACT THE LOCAL GAS COMPANY AND ARRANGE FOR GAS SERVICE AS INDICATED ON DRAWINGS. INCLUDE ALL COSTS, CHARGES, FEES, ETC., INCURRED BY LOCAL AUTHORITIES INTO BID. PROVIDE ALL MATERIALS AS REQUIRED BY LOCAL AUTHORITIES FOR GAS SERVICE INSTALLATION. ALL WORK SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF LOCAL AUTHORITIES.3. CONTACT THE LOCAL WATER DEPARTMENT AND ARRANGE FOR WATER AND WASTE SERVICES AS INDICATED ON DRAWINGS. INCLUDE ALL COSTS, CHARGES, FEES, ETC., INCURRED BY LOCAL AUTHORITIES INTO BID. PROVIDE ALL MATERIALS AS REQUIRED BY LOCAL AUTHORITIES FOR WATER AND WASTE SERVICE INSTALLATIONS. ALL WORK SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF LOCAL AUTHORITIES.IRRIGATION SYSTEM COORDINATION NOTES1. IRRIGATION SYSTEM WATER METER SIZE INDICATED ON PLUMBING SHEETS IS APPROXIMATE. IRRIGATION SYSTEM DESIGN TO BE PROVIDED BY OTHERS UNDER SEPERATE CONTRACT. COORDINATE WITH IRRIGATION SYSTEM DESIGNER REGARDING FINAL SIZING OF WATER METER PRIOR TO INSTALLATION. COORDINATE WITH IRRIGATION SYSTEM DESIGNER TO PROVIDE TOTAL CALCULATED GPM TO ******. 1. PIPING INSULATION USED SHALL HAVE A THERMAL CONDUCTIVITY OF 0.27 BTU PER IN/HR*SQFT*DEG F OR LESS. FIBERGLASS INSULATION WITH A FACTORY APPLIED VAPOR BARRIER, ASJ JACKET, FACTORY APPLIED PRESSURE SEALING LONGITUDE LAP JOINT, NO STAPLES, ZESTON PREMOULDED PVC FITTING COVERS. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.2. FLEXIBLE CLOSED CELL ELASTOMERIC THERMAL INSULATION, INSLIT OR PRESLIT WITH PRESSURE SENSITIVE ADHESIVE SYSTEM FOR CLOSURE AND VAPOR SEALING, EQUAL TO ARMSTRONG AP ARMFLEX OR ARMFLEX 2000.3. FOR NON-CIRCULATING SYSTEMS, THE FIRST 8 FEET OF INLET AND OUTLET PIPING BETWEEN THE TANK AND THE HEAT TRAP (INCLUDING THE HEAT TRAP) MUST BE INSULATED.4. INSULATION SCHEDULE:A. DOMESTIC COLD WATER: 1/2”B. DOMESTIC HOT WATER: 1”C. CONDENSATE DRAINS INSIDE BUILDING: 1”D. ROOF DRAIN AND OVERFLOW ROOF DRAIN PIPING (FIRST 30' FROM ROOF DRAIN): 1/2"E. REFRIGERANT SUCTION: 1-1/2” FOR PIPING UP TO 1-1/2” DIA., 2” FOR PIPING LARGER THAN 1-1/2”.PLUMBING INSULATION SPECIFICATIONS1. DOMESTIC COLD AND HOT WATER (ABOVE GROUND).A. TYPE L. HARD DRAWN COPPER TUBING, ASTM B-88.B. WROUGHT BRONZE SOLDERED FITTINGS.C. BALL VALVE: CRANE #932 OR EQUAL.2. PEX, HIGH-DENSITY CROSS-LINKED POLYETHYLENE TUBING SHALL BE MANUFACTURED TO THE REQUIREMENTS OF ASTM F876 AND MEET THE STANDARD GRADE HYDROSTATIC PRESSURE RATINGS FROM THE PLASTIC PIPE INSTITUTE IN ACCORDANCE WITH TR-4/03.A. PEX MECHANICAL, CRIMP/INSERT FITTINGS. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. PIPE SIZES GIVEN ON THE DRAWINGS ARE NOMINAL COPPER PIPE SIZE. INCREASE PEX PIPING SIZE AS REQUIRED TO EQUAL OR EXCEED COPPER PIPE INSIDE DIAMETER.3. DOMESTIC COLD AND HOT WATER (UNDERGROUND).A. TYPE K HARD OR SOFT DRAWN COPPER TUBING, ASTM B-88B. WROUGHT BRONZE SOLDERED FITTINGS.C. WROUGHT BRONZE FLARED FITTINGS.4. SANITARY SEWER AND VENTS (UNDERGROUND, INTERIOR TO BUILDING)A. POLYVINYLCHLORIDE (PVC) DWV PIPE, SCHEDULE 40, SOLVENT JOINT (WHERE APPROVED BY LOCAL CODES)B. SERVICE WEIGHT, BELL-AND-SPIGOT, COATED CAST IRON, ASTM A-74.C. NO-HUB CAST IRON, NEOPRENE GASKETS, STAINLESS STEEL CLAMPS.5. SANITARY SEWER AND VENTS (EXTERIOR TO BUILDING)A. POLYVINYLCHLORIDE (PVC) DWV PIPE, SDR-26 40, SOLVENT JOINT (WHERE APPROVED BY LOCAL CODES)B. ACRYLONITRILE-BUTADIENE-STYRENE (ABS) SEWER PIPE, SDR-23.5 OR SCHEDULE 40, SOLVENT JOINT (WHERE APPROVED BY LOCAL CODES).C. DUCTILE IRON GRAVITY SEWER PIPE AND FITTINGS, ASTM A746/747, CLASS 50 OR 51, SEAL COATED, MECHANICAL OR PUSH-ON JOINTS, DIP COATING, NEOPRENE OR SYNTHETIC RUBBER GASKETS.D. SERVICE WEIGHT, BELL-AND-SPIGOT, COATED CAST IRON, ASTM A-74.6. SANITARY SEWER AND VENTS (ABOVEGROUND)A. SERVICE WEIGHT, BELL-AND-SPIGOT, COATED CAST IRON, ASTM A-74.B. NO-HUB CAST IRON, NEOPRENE GASKETS, STAINLESS STEEL CLAMPS.C. POLYVINYLCHLORIDE (PVC) DWV PIPE, SDR-2640, SOLVENT JOINT (WHERE APPROVED BY LOCAL CODES AND NOT IN AIR PLENUM).7. ROOF DRAIN PIPINGA. SERVICE WEIGHT, BELL-AND-SPIGOT, COATED CAST IRON, ASTM A-74.B. NO-HUB CAST IRON, NEOPRENE GASKETS, STAINLESS STEEL CLAMPS8. CONDENSATE DRAINS AND INDIRECT WASTE (ABOVEGROUND)A. DWV, WROUGHT COPPER, ANSI B-16.29.B. POLYVINYLCHLORIDE (PVC) DWV PIPE, SCHEDULE 40, SOLVENT JOINT.9. CLEAN AND FLUSH ALL EXISTING WASTE PIPING LINES TO BE REUSED TO ENSURE THEY ARE FREE OF OBSTRUCTIONS.10. PROVIDE AN APPROVED WATER HAMMER ARRESTOR FOR EACH PLUMBING FIXTURE SUPPLY AS REQUIRED BY FIXTURE MANUFACTURER.11. PROVIDE CLEANOUTS AT EACH CHANGE OF DIRECTION AND AT 100 FOOT INTERVALS IN STRAIGHT RUNS.12. CLEANOUTS:A. WALL: JR SMITH #4472 OR EQUAL. 18" ABOVE FLOOR UNLESS OTHERWISE INDICATED.B. EXTERIOR: JR SMITH #4251-U OR EQUAL UNLESS OTHERWISE INDICATED.13. PROVIDE ACCESS PANELS FOR ALL CONCEALED TRAPS AND VALVES.14. PROVIDE DIELECTRIC UNIONS WITH APPROPRIATE END CONNECTIONS TO MATCH THE PIPE SYSTEM IN WHICH INSTALLED (SCREWED, SOLDERED, OR FLANGED). PROVIDE DIELECTRIC UNIONS ON ALL PIPING CONNECTION TO HOT WATER HEATERS AND EXPANSION TRAPS.15. ALL ROOF DRAIN AND SEWER PIPING SHALL BE INSTALLED WITH THE FOLLOWING SLOPES:A. INSTALL 3" AND SMALLER PIPE AT 1/4" PER FOOT FALL.B. INSTALL 4" AND LARGER PIPE AT 1/8" PER FOOT FALL.16. PVC PIPING TO BE SOLID CORE - CELLULAR CORE IS NOT ACCEPTABLE.17. THERE SHALL BE NO JOINTS IN DOMESTIC WATER PIPING BELOW SLABS. 18. UNDERGROUND COPPER JOINTS TO BE SILVER SOLDERED. IF PEX PIPING IS USED WITH F1807 FITTINGS, PIPE SIZES MUST BE INCREASED BY ONE PIPE SIZE ABOVE WHAT IS SHOWN ON PLANS. ALTERNATIVELY, PEX PIPING MAY BE USED AT SIZES INDICATED IF F1960 FITTINGS ARE USED.19. NATURAL GAS PIPING ABOVE GRADE SHALL BE SCH. 40 BLACK STEEL PIPE WITH CLASS 150 MALLEABLE IRON THREADED FITTINGS. ALL NEW EXTERIOR GAS PIPING SHALL BE PAINTED TO MATCH BUILDING WHERE EXPOSED ON BUILDING FACE AND YELLOW IN ALL OTHER LOCATIONS. ROOFTOP MOUNTED PIPING SHALL BE FASTENED TO AND SUPPORTED BY "ROOFTOP BLOX".20. PLUMBING FIXTURES SHALL BE AS INDICATED ON DRAWING. FURNISH AND INSTALL CHROME STOP VALVES, SUPPLIES, ESCUTCHEONS AND TRAPS AS REQURIED FOR ALL FIXTURES. 21. ALL FOUNDATION DRAINS TO BE PERFORATED PVC PIPE WITH FABRIC SLEEVE AND TO BE INSTALLED WITH MINIMUM 1/16" PER FOOT FALL.PLUMBING PIPING SPECIFICATIONSFIRE PENETRATION NOTES1. THIS PROJECT CONTAINS FIRE RATED ASSEMBLIES. LOCATIONS ARE INDICATED ON ARCHITECTURAL PLANS.2. ALL CONTRACTORS SHALL PROVIDE PROTECTION FOR THEIR PENETRATIONS THRU THESE ASSEMBLIES AS FOLLOWS.A. FOR ALL PENETRATIONS THRU OR INTO FIRE RATED VERTICAL OR HORIZONTAL ASSEMBLIES:a. A UL LISTED PENETRATION FIRESTOP SYSTEM SHALL BE INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E814 OR UL 1479 (IBC 714.3)b. GENERAL CONTRACTOR TO PROVIDE AND MAINTAIN A BOOK WITH ALL FIRE PENETRATION PROTECTIVE SYSTEMS THAT WILL BE USED ON THIS PROJECT. THIS BOOK MUST REMAIN ON SITE AT ALL TIMES.CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.REVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPP000P000P000P000PLUMBING NOTES,PLUMBING NOTES,PLUMBING NOTES,PLUMBING NOTES,SSSSPPPPEEEECCCCIIIIFFFFIIIICCCCAAAATTTTIIIIOOOONNNNSSSS,,,, AAAANNNNDDDD LLLLEEEEGGGGEEEENNNNDDDDSSSSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare# Description Date 234BA678195URS2DFWCFDFDFDWFMSL1S1WCL1L1PW14" SS4" SS3" SS2" V2" V4" SS2" V4" VTR4" SSYCOPIT 1PIT 2PIT 34" INLETS BETWEEN PITSSLOPE1-1/2" WASTEWATER DISCHARGE INTO PIT 1FD3" FLOOR DRAIN DISCHARGE INTO PIT 2L1L1URURWC3" SS4" SS4" SS2" V2" VFCO23WP11FCOFCOFCOCHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPP101P101P101P101SSSSAAAANNNNIIIITTTTAAAARRRRYYYY PPPPLLLLUUUUMMMMBBBBIIIINNNNGGGG PPPPLLLLAAAANNNNSSSSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare1/8" = 1'-0"1111Sanitary Plumbing PlanSanitary Plumbing PlanSanitary Plumbing PlanSanitary Plumbing Plan#1. COORDINATE ROUTING OF SANITARY SEWER PIPING AND CONNECTIONS WITH LOCAL UTILITY.2. PROVIDE CONNECTIONS FOR WASH WATER PROCESSING EQUIPMENT IN UTILITY ROOM AS REQUIRED. PIPE 1-1/2" SHC80 PVC DISCHARGE ACROSS PIT DIVIDER INTO PIT 1. FINAL CONNECTIONS TO EQUIPMENT BY VENDOR.3. INSTALL SUMP PUMP IN PIT 3 AND PROVIDE 2" DISCHARGE INTO UTILITY ROOM, 2' ABOVE FINISHED FLOOR. FINAL CONNECTIONS TO EQUIPMENT BY VENDOR.# Description Date 234BA678195URS2DFWCGMWFMSL1S1BFPWH1FPHBFPHBFPHBFPHBFPHBFPHBREF121212121234WCL1L1PW11" CW3/4" HW3/4" HW2" CW2" CW1/2" HW2" CW1 1/2" G1/2" HW-R1/2" HW-RFBV0.5 GPMRP1ON MEZZANINE PLATFORMF11-5F21-51 1/4" G3/4" CW1" CA1 1/2" G3/4" CW1" OL1 1/2" G1" CW1" CW1" CA1" OL2" G1" CW1" OL1" CW2" G1" CA1" OLL1L1URURWC121" CD2 1/2" G1" G3/4" HW1" CW1" CW1/2" HW-R689107RH2RH15FBV0.5 GPMFBV0.5 GPMFBV0.5 GPMRH3RH41 1/2" G6" CWGWP1111" CW2" G1" CA6CHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPP102P102P102P102DDDDOOOOMMMMEEEESSSSTTTTIIIICCCC WWWWAAAATTTTEEEERRRR &&&& GGGGAAAASSSSPLUMBING PLANSPLUMBING PLANSPLUMBING PLANSPLUMBING PLANSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentShare1/8" = 1'-0"1111Domestic Water & Gas Plumbing PlanDomestic Water & Gas Plumbing PlanDomestic Water & Gas Plumbing PlanDomestic Water & Gas Plumbing Plan1. 1" COMPRESSED AIR DROP WITH QUICK CONNECT COUPLING 1/4" FNPT HOSE FITTING AT 42" A.F.F.2. 1" BULK MOTOR OIL DROP CAPPED AT 42" A.F.F.3. BULK MOTOR OIL TANKS WITH 1" OIL PIPING CONNECTIONS. PROVIDE 1" AIR DROP AND COMPRESSED AIR CONNECTION TO PNEUMATIC PUMP. COORDINATE EXACT LOCATION.4. 1" CONNECTION TO AIR COMPRESSOR. COORDINATE EXACT LOCATION.5. 1" CW, HW, &HW-R UP TO WATER HEATER ON MEZZANINE.6. COORDINATE LOCATION OF GAS METER AND ROUTING OF SERVICE PIPING WITH LOCAL UTILITY. APPROXIMATE TOTAL CONNECTED LOAD=925,000 BTUH @ 7-14" W.C. DELIVERY PRESSURE.7. COORDINATE ROUTING OF DOMESTIC AND FIRE PROTECTION WATER PIPING, METERING REQUIREMNETS AND CONNECTIONS WITH LOCAL UTILITY.8. FIRE PROTECTION RISER AS REQUIRED FOR NEPA 13 COMPLAINT FIRE PROTECTION SYSTEM. FIRE PROTECTION SHOP DRAWINGS SHALL BE A DEFERRED SUBMITTAL TO THE AHJ.9. DOMESTIC WATER SERVICE AND BLACKFLOW PREVENTER, PIPE DISCHARGE TO FLOOR DRAIN.10. SEE WATER HEATER RECIRCULATION SCHEMATIC SHEET P601 FOR ADDITIONAL DETAILS AND VALVES REQUIRED.11. PROVIDE 1" CW PIPING AND 1-1/2" GAS PIPING FOR HEATED PRESSURE WASHING EQUIPMENT AS REQUIRED. FINAL CONNECTIONS TO EQUIPMENT BY VENDER.## Description Date CROSS-SECTION OFHORIZONTAL DRAINCENTER LINEDRY VENTS TO CONNECT ABOVE CENTER LINEWHERE CONNECTING TO HORIZONTAL DRAIN PIPESTSEXP1T/P VALVEHEAT TRAPSWATERHEATER1"⌀MIN. INDIRECTDRAIN TO SEWER2" DEEP DRAIN PAN (22 GA. GALV.)NOTE:ALL HOT WATER & COLD WATERSHALL BE INSULATED PER SPECIFICAITONSLAV(FURTHESTDISTANCEIN LOOP)HOT WATER½" HOT WATER RECCOLD WATERTEMPERATURE SENSOR120V AQUASTAT SET @ 110°FRECIRCULATION PUMP (RP)AIR BLEED(HOSE BIBB)AT HIGH POINTSHUT-OFF VALVEIGNITER SENSOR BOXREFLECTORBURNER TUBETO GAS LINEw/ DRIP LEGSTAINLESS STEELGAS CONNECTOR,FORMED INTOSMOOTH "C-SHAPE"FRESH AIR INTAKE12"HEATER MOVEMENT2" MAX DISPLACEMENTBURNER CONTROL BOXCHECKSETThe Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.SHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDSHEET KEYNOTE LEGENDREVISIONS:EEEEquipmentSharequipmentSharequipmentSharequipmentShare5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. 5710 Bull Run Rd. Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201Columbia, MO 65201ARCHITECTARCHITECTARCHITECTARCHITECTCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCONSTRUCTIONCIVILCIVILCIVILCIVILSTRUCTURALSTRUCTURALSTRUCTURALSTRUCTURALMEPMEPMEPMEPP601P601P601P601PPPPLLLLUUUUMMMMBBBBIIIINNNNGGGG SSSSCCCCHHHHEEEEDDDDUUUULLLLEEEESSSSTier 4Tier 4Tier 4Tier 45555777711110000 BBBBuuuullllllll RRRRuuuunnnn DDDDrrrr....CCCCoooolllluuuummmmbbbbiiiiaaaa,,,, MMMMOOOO 66665555222200001111EquipmentShareEquipmentShareEquipmentShareEquipmentSharePLUMBING EQUIPMENT SCHEDULEMARK DESCRIPTIONBASIS OF DESIGNREMARKSMANUFACTURER MODELWH-1 WATER HEATER AO SMITH DEL-5050 GALLON 208/240V, 1PH, 4500 WATT(LOWBOY) WITH EXP1PW-1 PRESSURE WASHER ALKOTA 4301RP-1 RECIRCULATION PUMP GrundfosUSE TYPECATALOG120V, 60 WWP-1WASH WATER PROCESSINGEQUIPMENTESD HSMS-800WASH WATER RECYLING SYSTEMWITH 20 GPM WATER CANNON.120/240V WITH NEUTRAL, 80 AMPS.SP-1 SUMP/SEWAGE PUMP ZOELLER N264NON-AUTOMATIC SEWAGE PUMP,115V, 4/10 HP. 6' TDH, 80 GPM.PIPING ACCESSORIESMARK DESCIPTIONBASIS OF DESIGNCOMMENTSMANUFACTURER MODELBFPDOMESTICBACKFLOWZURN 975 XLDOMESTIC WATER REDUCED PRESSURE PRINCIPLE BACKFLOWPREVENTERFBVFLOW BALANCINGVALVENEXUS UMNL PRESSURE DEPENDENT ON FLOW VALVE. 0.5 GPMGM GAS METER - - 7" W.C. GAS METER ASSEMBLYPLUMBING FIXTURE SCHEDULEMARK DESCRIPTIONBASIS OF DESIGNREMARKSMANUFACTURER MODELDFBI-LEVEL DRINKING FOUNTAIN WITH BOTTLEFILLERELKAY LVRCTL8WSK HI / LOW WITH BOTTLE FILLEREXP1 EXPANSION TANK WATTS PLT-5FD FLOOR DRAIN WITH TRAP GUARD ZURN Z415S-Z1-NH-9 WITH PROSET TG33-ZURN TRAP GUARDFPHB FROST-PROOF HOSE BIBB ZURN Z1321L1 WALL-HUNG LAVATORY ZURN Z5341WITH ZURN Z81104-XL FAUCET, MV, AND TRUEBRO "LAVGUARD"TRAP, STOP AND SUPPLY COVERMS MOP SINK ZURN Z1996-24 WITH CHICAGO FAUCET 897 RCF.REF REFRIGERATOR ICE MAKER BOX SOUIX CHIEF 68-1000MF SHANK CONNECTION= MIP/FSWTS1 DROP-IN BAR SINK MOEN TG2045522 WITH GOOSENECK SINGLE HANDLE FAUCETS2 DROP -IN KITCHEN SINK ELKAY CR3322-3 WITH MOEN 8799 FAUCETUR URINAL - FLUSH VALVE (MANUAL)AMERICANSTANDARD6550.001 WHITE, WITH ZURN Z6003A V FLUSH VALVE (MANUAL)WC WATER CLOSET - FLOOR-MTD TANK TYPE - ADAAMERICANSTANDARD215AA.104 WHITE, WITH CHURCH 295SSCT SEATWF 36" SEMI-CIRCULAR WASH FOUNTAIN BRADLEY SN2003FOOT OPERATED, WITH THERMOSTATIC MIXING VALVE,SUPPLIES AND STOPSNOT TO SCALE1111DRY VENT DETAILDRY VENT DETAILDRY VENT DETAILDRY VENT DETAILNOT TO SCALE2222TYPICAL HOT WATER RECIRCULATION SCHEMATICTYPICAL HOT WATER RECIRCULATION SCHEMATICTYPICAL HOT WATER RECIRCULATION SCHEMATICTYPICAL HOT WATER RECIRCULATION SCHEMATICNOT TO SCALE3333TYPICAL GAS RADIANT HEATER DETAILTYPICAL GAS RADIANT HEATER DETAILTYPICAL GAS RADIANT HEATER DETAILTYPICAL GAS RADIANT HEATER DETAIL# Description Date