Loading...
HomeMy WebLinkAbout17-046 ApplicationCitv of Little Rock Planning and Development Building Codes 723 West Markham Little Rock, Arkansas 72201-1334 Routing Slip for Commercial Building Permit Project Name: McDonald's Project Address: 10201 N. Rodney Parham Application Number: 201707119 Distribution Date: 8.17.17 Comments Due: 8.31.17 Contact Information: Name: Bob Kempkes Taylor/Kempkes Architects Phone: 501.282.0513 E-mail: bob@taylorkempkes.com Type of Project: New Building Occupancy Use: Assembly A-2 Restaurant Occupancy Load: 104 Type of Construction: V-B Area of building: 4456 S.F. Number of Stories: 1 Height: 19'- 0" Fire Zone: NO Sprinklers: YES Fire Alarm: NO Reviewer: Mark Alderfer E-mail Address: malderfer@littlerock.gov Phone: 501.371.4875 17-046 — McDonald's —10201 N Rodney Parham— 201707119 1. Site plan must comply with the City's minimal landscape / buffer ordinance requirements, the requirements of the City Beautiful Commission variance case #656. 2. Signage is to be reviewed and permitted separately. 3. Landscape plan is acceptable. However, plans that were submitted are indicated as "Not For Construction". Construction drawings must be received before the issuance of a building permit. Three (3) copies of the construction document sheet 1-1.0 shall be returned to the Plans Development Administrator before the permit can be released. 4. All landscape areas shall be protected as per City of Little Rock Landscape Ordinance (Sec. 15- 100). Mulch, edging, wheel stops, and/or concrete curb and gutter will be required. 5. All ground or roof mounted mechanical systems shall be screened from abutting properties and streets. Any trash receptacles or pickup shall be oriented away from a primary street side of the property and screened from the public right-of-way. Screen shall exceed the height of the dumpster or trash containment areas by at least two (2) feet not to exceed eight (8) feet total height. As per Sec. 36-298. - General district restrictions. No excessive or unusual noise, shall be emitted so that it constitutes a nuisance which substantially exceeds the general level of noise emitted by uses adjacent to or immediately surrounding the site. A sound deflection board at least six (6) feet in height and twenty (20) feet in length along the opposite lane of the menu order board will be required. Confirm deflection wall will be constructed. If a deflection board is not desired a variance from the Board of Adjustment may be required. Contact Zoning and Enforcement Administrator, Mr. Monte Moore at 501-371-4792 or mmoore(@Iittlerock.gov for additional information. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. f Development Compliance Review Zoning, Subdivision, and Landscaping ADDRESS: 10201 N Rodnev Parham LEGAL DESCRPIPTION BRECKENRIDGE BUSINESS LT I & PT LTA BLK 8 BEG NE COR LT 1 S41 *W216 65'S37* W23 4' N50* W126 58' N77 43' BRECKENRIDGE BUSINESS LT 1 & PT LT A BLK 8 BEG NE COR LT 1 S41*W216 65' S37* W23 4' N50* W126 58' N77 43' N40* E144.7' TO S R/W RODYARH RD S61 * E177' TO BEG ZONING CLASSIFICATION C-4 Z CASE NO(S) ZONING- N N/A S C-4 E N/A W C-4 SITE PLAN APPROVAL REQUIRED: NO ("R-6"; "R-7; "0-2"; "C-3"; "I-1"; "PZD" & "CUP") CZD MACARTHUR PARK HIST. DIST. RIVER MARKET DIST (If located in one of the above districts, approval of governing body must be obtained before permit can be issued) STREETS Rodney Parham North Breckenridge East EASEMENT CLEARENCE APPROVED DENIED N/A X REQUIREMENT CHART HGT. FRONT SIDE(S) REAR PLATTED SITE AREA CVG MIN SEP. REQUIRED: 35' 1 45' 15' 15' 1257 14,000 sgft N/A N/A PURPOSED: 1 40 1 72' 1 53' 1 76' j 84' .857 Acres I N/A I - ANCILLARY STRUCTURES: ("C-2" Only) MAX. ST.FRTG. COV ALLOWED: 40% PROPOSED N/A SPECIAL REGULATIONS: BOARD OF ADJUSTMENT (CASE No. } DATE: BOARD OF ADJUSTMENT (CASE No. ) DATE: BOARD OF ADJUSTMENT (CASE No. ) DATE: BOARD OF ADJUSTMENT (CASE No. _ ] DATE: APPOVED SITE PLAN COMPLIANCE ("R-6"; "R-7"; "0-2"; "C-2"; "I-1"; "PZD" & "CUP") SPECIFIC REQUIREMENTS, CONDITIONS, OR VARIANCE COMPLIANCE SIGNAGE PLAN: N/A APPROVED AS SUBMITTED. I';V;F 2 NOT SUBMITTED DENIED FOR THE FOLLOWING REASONS STREET PARKING AND LOADING ■ OFF STREET SPACES REQUIRED: 45 (By Sec. Sec. 36-502) Restrurrrrnts L0 simee f{►r each oil hundred (10(0 .square feet ofZross floor area. PROVIDED 40 + 11 Stacking Spaces OFF -SITE Adjacent shopping center parking COMPACT CARS QXAAT T nThAPKT3TnNT WTnTu T)F.PTu MANFINFUNG AREA WIDTH DEPTH MANEUVERING PARALLEL 22' 9' 11' RIGHT ANGLE 60 DEGREES 45 DRGREES 9' 20' 20' PROPOSED PROPOSED 22' 8.5 11 8.5' 20' 20' 8.5 18' 18' 8.5' 18' 12' OFF-STREET LOADING SPACES REQUIRED N/A (By Sec. 36-504) PROVIDED: OFF-STREET LOADING SPACE SIZE: 12' X 30' W/14' HEIGHT CLEARANCE PROVIDED: WHEEL STOPS REQUIRED: N_ S E W PROVIDED: N S E W. Curb and gutter & wheel stops noted on plan LANDSCAPING / BUFFER REQUIREMENTS SPECIFY: Attached and entered into Cornerstone. Permit Number, 20I707119 EASEMENT IN -LIEU IRRIGATION YES MATURE AREA NO REGISTERED LANDSCAPE ARCHITECT NO VARIANCE GRANTED N/A SUMMARY OF ZONING SUBDIVISION AND LANDSCAPING REGULATIONS REQUIREMENTS NOT SATISFIED NO VIOLATION OF USE REGULATIONS NO VIOLATION OF YARD SPACE AND/ORAREA REQUIRMENTS (Lot Coverage) NO SPECIAL DISTRICT (Must receive approval by governing body before permit can be issued) YES EASEMENTS MUST REMAIN CLEAR AND UNOBSTRUCTED. YES SUBMITT LANDSCAPE BUFFER PLAN IN ACCORDANCE WITH LANDSCAPE CODE CHAPTER 15 & 36. YES SITE PLAN APPROVAL REQ. ("R-6"; "R-7; "0-2"; "C-2"; "I-1"; "PZD & "CUP"). SPECIFY: Landscape Plans are noted "Not For Construction" Change designation before releasing permit. ADDITIONAL REQUIREMENTS NOT SATISFIED APPROVED DENIED NOT SHOWN PAVING OF VEHICULAR USE AREA X SCREENING ON THE N,S,E,W A. ZONING CODE CHAPTER 36 X B. LANDCAPE CODE CHAPTER 15 X NUMBER OF PARKING SPACES PROVIDED X A. STALL AND MANEUVERING AREA X NUMBER OF LOADING SPACES PROVIDED X B. STALL AND MANEUVERING AREA X WHEEL STOPS PLACED 30" INSIDE PROPERTY LINE(S) ALONG THE N, S, E, W SIDES X SIGNAGE PLAN X CONDITIONAL USE OR BOARD OF ADJUSTMENT X SPECIAL CONDITIONS REQUIREMENTS *Submit plans in accordance with requirements governing each of the above items not shown on this application in order to receive approval of the construction permit. APPLICATION IS APPROVED AS SUBMITTED X APPLICATION CANNOT BE APPROVED UNTIL ALL REQUIREMENTS LISTED ABOVE ARE SATISFIED. DATE: 8.18.17 D. Tracy Spillman PLANS DEVELOPMENT ADMINISTRATOR 502-371-4864