Loading...
HomeMy WebLinkAbout19-004 Application19-004 — Immanuel Outreach Church Ministries - 1123 Welch St — 201910451 1. Any new site development must comply with the City's minimal landscape and buffer ordinance requirements and the CUP approved by the Planning Commission (file number, Z-9345). 2. Signage is to be reviewed and permitted separately. 3. Landscape plan is not complete. Permit cannot be released until landscape requirements are met. Additional and complete review will be made upon the receiving landscape plan, and survey. Submit three (3) full size copies of the revised landscape plan and one (1) full size copy of the survey for review and approval. 4. For any site, trees from two (2) different genuses are required. At least twenty-five (25) percent of the trees on the site outside of those required for screening purposes are to be of evergreen variety. Trees must be a minimum of 2" in caliper at installation. Note the species and size specifications of the proposed trees on the plan. For any site, shrubs from two (2) different genuses are required. At least twenty-five (25) percent of the shrubs on the site outside of those required for screening purposes are to be of evergreen variety. Shrubs must be a minimum of 18" in height at installation. Note the species and size specifications of the proposed Shrub materials on the plan. 6. Land use buffers are to be maintained adjacent to the Welch Street R-4 zoned property to the north. As a component of all land use buffer requirements, opaque screening, whether a fence or other device, a minimum of six (6) feet in height shall be required upon the property line side of the buffer. A minimum of seventy (70) percent of the land use buffer shall be undisturbed. In addition to the required screening, buffers are to be landscaped at the rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet. Note on the plan if a fence or other screening device is in place or proposed along this north property line. If a fence is to be incorporated note that it will be constructed with the face directed outward towards the neighboring property. The property is approximately 160 linear feet in depth. A minimum of five (5) trees and sixteen (16) shrubs will be required between the proposed structure and north property line. 7. Trees and shrubs are required along any street right-of-way at the rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet. The Welch Street property is approximately 160 linear feet in depth. A minimum of five (5) trees and sixteen (16) shrubs will be required between the proposed structure and the E 12th St right-of-way. 8. Street buffers will be required at six (6) percent of the average depth of the lot. The property is located in the City's designated mature area. Atwenty-five (25%) percent reduction of the buffer requirements is acceptable. Requirements for landscaping in land use buffers shall be the same as perimeter landscaping plant materials are to be provided at the rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet. The depth of the College Street lot is approximately 160 feet. A minimum seven (7) foot street buffer will be required between the vehicular use area and the right-of-way. There is thirty-six (36) feet of vehicular use (excluding the drive) area adjacent to the street right-of-way. In addition to evergreen screening shrubs spaced not less than three feet on center one (1) tree will required to be placed in this buffer to meet the minimum landscape requirements. 9. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property, or the right-of-way of any street. This strip shall be at least six (6) feet, nine (9) inches in width in areas designated as "mature". One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. The College Street property is approximately 160 linear feet in depth. The north and south perimeters of the parking area will require a minimum of five (5) trees and sixteen (16) shrubs adjacent to both the north and south property lines. • No landscape is required between the parking and alley. 10. Screening requirements will need to be met for the vehicular use areas adjacent to street right- of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. • There is approximately seventy-five (75) linear feet of vehicular use area adjacent to the Welch Street right-of-way. A minimum of twenty-five (25) shrubs and three (3) trees will be required in this area. 11. Interior landscape areas shall comprise at least eight (8) percent of any vehicular use area containing twelve (12) or more parking spaces. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. • A minimum of three (3) trees will be required to meet the interior landscape requirements for thirty (30) parking spaces. 12. An irrigation system shall be required for developments of one (1) acre or larger. Note on the landscape plan "An automatic irrigation system shall be provided for all new landscape areas and provide 100% full coverage." Or graphically represent the location of the hose bibs on the plan and note "A water source for landscape irrigation shall be located no further than seventy-five (75) feet of all plants or turf." 13. All landscape areas shall be protected as per City of Little Rock Landscape Ordinance (Sec. 15- 100). Wheel stops, and/or concrete curb and gutter will be required between vehicular use areas and any turf or planting area. 14. All ground or roof mounted mechanical systems shall be screened from abutting properties and streets. Any trash receptacles or pickup shall be oriented away from a primary street side of the property and screened from the public right-of-way. Screen shall exceed the height of the dumpster or trash containment areas by at least two (2) feet not to exceed eight (8) feet total height. 15. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. k r` Development Compliance Review Zoning, Subdivision, and Landscaping ADDRESS: 1123 Welch LEGAL DESCRPIPTION LOTS 2 THRU S BLOCK 9 MASONIC TO THE CITY OF LITTLE ROCK PULASKI COUNTY ARKANSAS ZONING CLASSIFICATION R4 CUP Z CASE NO(S) Z-9345 ZONING- N R2 S 03 E N/A W R2 SITE PLAN APPROVAL REQUIRED: YES ("R-6"; "R-7; "0-2"; "C-3"; "I-1"; "PZD" & "CUP") CZD MACARTHUR PARK HIST. DIST. _ RIVER MARKET DIST (If located in one of the above districts, approval of governing body must be obtained before permit can be issued) STREETS Welch St (west). College St (cast). E 12th St (soutb) EASEMENT CLEARENCE APPROVED DENIED N/A X REQUIREMENT CHART HGT. FRONT SIDE(S) REAR PLATTED SITE AREA CVG MIN SEP. REQUIRED: 14' N/A N/A N/A N/A N/A N/A N/A eave bt PURPOSED: 1 42' 25' 1 120' 1 10' Each lot > story 1 acre As per approved CUP ANCILLARY STRUCTURES: ("C-2" Only) MAX. ST.FRTG. COV ALLOWED: 40% PROPOSED N/A SPECIAL REGULATIONS: BOARD OF ADJUSTMENT (CASE No. ) DATE: BOARD OF ADJUSTMENT (CASE No. ) DATE: BOARD OF ADJUSTMENT (CASE No..�} DATE: BOARD OF ADJUSTMENT (CASE No. ,) DATE: X APPOVED SITE PLAN COMPLIANCE ("R-6"; "R-7; "0-2"; "C-2"; "I-1"; "PZD" & "CUP") SPECIFIC REQUIREMENTS, CONDITIONS, OR VARIANCE COMPLIANCE SIGNAGE PLAN: N/A APPROVED AS SUBMITTED. NOT SUBMITTED DENIED FOR THE FOLLOWING REASONS STREET PARKING AND LOADING OFF STREET SPACES REQUIRED: 28 (By Sec. Sec. 36-502) As approved for Phase I of the CUP PROVIDED 30 OFF -SITE N/A COMPACT CARS CARAT T nTTAT7NTernV AUTF)TT4 T)PPTT4 MA7,J_FTTVFRWG AREA WTDTH DEPTH MANEUVERING PARALLEL 22' 9' 11' RIGHT ANGLE 9' 20' 20' 60 DEGREES 9' 16' 22' 45 DRGREES 9' 18 12' PROPOSED PROPOSED 22' 8.5 11 8.5' 20' 20' 8.5' 18' 18' 8.5' 18' 12' OFF-STREET LOADING SPACES REQUIRED N/A (By Sec. 36-504) PROVIDED: _ OFF-STREET LOADING SPACE SIZE: 12' X 30' W/14' HEIGHT CLEARANCE PROVIDED: WHEEL STOPS REQUIRED: N_ S E W, Corh and gutter indicated on plan I: 21 N DSCAPING / BUFFER REQUIREMENTS SPECIFY: Attached and entered into IPS . Permit Number. 201909100 PROVIDED: N S E W EASEMENT IN -LIEU IRRIGATION Unkown MATURE AREA NO REGISTERED LANDSCAPE ARCHITECT NO VARIANCE GRANTED YES PA( .rE 3 SUMMARY OF ZONING SUBDIVISION AND LANDSCAPING REGULATIONS REQUIREMENTS NOT SATISFIED NO VIOLATION OF USE REGULATIONS NO VIOLATION OF YARD SPACE AND/ORAREA REQUIRMENTS (Lot Coverage) NO SPECIAL DISTRICT (Must receive approval by governing body before permit can be issued) YES EASEMENTS MUST REMAIN CLEAR AND UNOBSTRUCTED. NO SUBMITT LANDSCAPE BUFFER PLAN IN ACCORDANCE WITH LANDSCAPE CODE CHAPTER 15 & 36. NO SITE PLAN APPROVAL REQ. ("R-6"; "R-7"; "0-2"; "C-2"; "I-1"; "PZD & "CUP") X SPECIFY: Additional landsca a and zoning requirements to be proyidgl ADDITIONAL REQUIREMENTS NOT SATISFIED APPROVED DENIED NOT SHOWN PAVING OF VEHICULAR USE AREA X SCREENING ON THE N,S,E,W A. ZONING CODE CHAPTER 36 X B. LANDCAPE CODE CHAPTER 15 X NUMBER OF PARKING SPACES PROVIDED X A. STALL AND MANEUVERING AREA X NUMBER OF LOADING SPACES PROVIDED X B. STALL AND MANEUVERING AREA X WHEEL STOPS PLACED 30" INSIDE PROPERTY LINE(S) ALONG THE N, S, E, W SIDES X SIGNAGE PLAN X CONDITIONAL USE OR BOARD OF ADJUSTMENT SPECIAL CONDITIONS REQUIREMENTS X *Submit plans in accordance with requirements governing each of the above items not shown on this application in order to receive approval of the construction permit. APPLICATION IS APPROVED AS SUBMITTED X APPLICATION CANNOT BE APPROVED UNTIL ALL REQUIREMENTS LISTED ABOVE ARE SATISFIED. DATE: 1.28.18 D. Tracy Spillman PLANS DEVELOPMENT ADMINISTRATOR 502-371-4864 City of Little Rock Planning and Development Building Codes 723 West Markham Little Rock, Arkansas 72201-1334 Routing Slip for Commercial Building Permit Project Name: Immanuel Outreach Church Ministries Project Address: 1123 Welch Route Number: 201809 100 Application Date: 1-24-19 Date Due Out: 2-5-19 Applicant Contact Information: Name: Address: Phone: Fax: E-mail: Type of Project: Occupancy: Type of Construction: Height and Area of Building: Number of Stories: Fire Zone: Sprinklers: Fire Alarm Standpipe: Reviewer: Curtis Richey E-mail Address: crichey@,littlerock.gov Phone: 501.371.4724 Woods Group Architects — Ron Woods 501-425-4972 rwoods@woodsga.com New A-3 / B VB 24 1 No No -TBD No -TBD No