HomeMy WebLinkAbout14-097 Map 3FINISH
SET ROOTFLARE 3"
ABOVE FINISHED GRA
REMOVE CONTAINER OR
BURLAP & WIRE FROM T(
113 OF ROOTBALL
BACKFILL MIXTURE -
SCARIFY WALLS -
AND BOTTOM OF
PIT
TREES TO BE ANCHORED BY
METHOD SHOWN IN DETAILS
MULCH
PLANT QUANTITY CALCULATION EXAMPLE FOR 100 SQ FT.
AREA (d 2' O.C. SPACING
SQUARE SPACING: AREA (IN SQ FT.) 100 = 25 QTY
SPACING' (IN FEET) 2'
TRIANGULAR SPACING: AREA (IN SO FT.M0.86 10010.86 = 29 QTY
SPACING' (IN FEET) 2'
INSTALL SHORT PRONG
HALFWAY BETWEEN TRUNK
AND EDGE OF ROOT BALL -
INSTALL LONG PRONG UP
AGAINST SIDE OF ROOT BALL
TREE REF.
PLANTING PLANS
DEVELOPMENT
CONSULTANTS
INCORPORATED
:OPYRIGHT:
2014
V=20'
DRAWN BY:
EH4
CHECKED BY:
DW
APPROVED BY:
EH4
DATE:
11-24-2014
1�. �( `ROOTBALL
AS NOTED
�
�
�f
LOCATION
PLAN
(TYP.)
\\\1
_
I---PLANT
16" Q GROUNDCOVER
PLANS""
w
�
TREE REF.
W
--I AS NOTED
PLANTING
NOTE:
ECESS TREE STAPLE DEVICE 1"
SPACING DIAGRAM REFERS TO ALL PAVING EDGE/BUILDING!
TO 2" INTO ROOT BALL TO FINISH
BELOW GRADE7
Q
PLANTING UNLESS NOTED OTHERWISE. CURB/STEEL EDGING
Y0
z
PLAN
O
GRADE TRIANGULAR SPACING DETAIL
TREE STAPLE
a
W
3
PER MANUFACTURERS
RECOMMENDATIONS
0
N.T.S.
TEL: (877) 873 3749
I 1
V
12" MIN. INTO
UNDISTURBED SUBGRADE
Z
UNDISTURBED OR
COMPACTED SUB -GRADE
�2.5 x ROOTBALL DIAMETER
SECTION
TREE PLANTING DETAIL
N.T.S.
NOTES:
1. PLANTING BED TO BE COMPLETELY OVER -EXCAVATED & FILLED W/ BACKFILL MIXTURE
2. BEFORE LAYING PLANTING MIXTURE, SCARIFY SUBGRADE IN THE DIRECTION OF SLOPE
FOR POSITIVE DRAINAGE
3. ALL LABELS TO BE REMOVED AFTER FIRST PUNCH INSPECTION
KEEP MULCH AWAY
FROM BASE OF PLANT - _ a
2" MULCH
SPACING AS PER
PLANTING PLAN &--�----{
SPACING CHART r6" MIN.
`UNDISTURBED
SUBGRADE
SECTION
PLANTING BED DETAIL
N.T.S.
1/B" STEEL
EDGING
GRASS
AREA
PLANTING/GRAVEL
AREA (REF. PLANS)
EDGING 1"ABOVE
PLANTING/GRAVEL
STEEL EDGING AS
REQUIRED BY OWNER
(SEE DETAIL)
REMOVE CONTAINER &
PRUNE ANY CIRCLING
ROOTS
GRADE
EXISTING
SOIL
SECTION
STEEL EDGING AT PLANTING/GRAVEL
N.T.S.
J..
TS24
1" TO 2" CALIPER 2
UNITS PER TREE
4"
TS36
3Q"—��
2" TO 4" CALIPER - 3
N
UNITS PER TREE
42" I
TS42
_L
4" TO 6" CALIPER - 3
UNITS PER TREE
I
�i 12"�
TS48
6" TO 8" CALIPER - 3
UNITS PER TREE Iml ITr
�{ 12" I--
NOTES:
1. DETERMINE THE PROPER SIZE TREE STAPLE DEVICE BY
MEASURING THE DEPTH OF THE ROOT BALL, BACKFILL MIX,
AND DRAINAGE GRAVEL, PLUS ADDING 12"-18" INTO
UNDISTURBED SUBGRADE. ROUND UP TO THE NEXT SIZE IF
NECESSARY.
2. IN EXTREME WIND AND/OR LOOSE SOIL CONDITIONS. USE
THREE TREE STAPLE DEVICES PER TREE AND/OR ROUND
UP TO THE NEXT SIZE.
TREE STAPLE SIZE
AND QUANTITY GUIDE
N.T.S.
INSTALL SHORT PRONG
HALFWAY BETWEEN TRUNK
AND EDGE OF ROOT BALL —
TREE REF.
PLANTING PLANS
PLAN
INSTALL LONG PRONG UP
AGAINST SIDE OF ROOT BALL
TREE REF.
PLANTING PLANS
RECESS TREE STAPLE DEVICE 1"
TO 2" INTO ROOT BALL TO FINISH
BELOW GRADE
TREE STAPLE:
PER MANUFACTURERS
RECOMMENDATIONS
TEL: (877) 873 3749
12" MIN. INTO-"
UNDISTURBED SUBGRADE
SECTION
TREE STAPLE - TWO STAPLE DETAIL
N.T.S.
SECTION
lTmillIr.\I■
N :/ *
1,4&nset/
Z
W
2
a
0
.J
uj
0
J
W
w
O
J
Z_
ui
O
�w
V
0
wo
Oa
LL z
z
W rc
J a
Yx
Q � W
T rJ
iif^ J
14-149