Loading...
HomeMy WebLinkAbout18-015 Map 3!F SET ROOTFLARE 3' ABOVE FINISHEDGRADE REMOVE CONTAINER OR BURLAP & WIRE FROM TOP 1/3 OF ROOTBALL BACKFILL MIXTURE \ SCARIFY WALLS AND BOTTOM OF PIT TREES TO BE ANCHORED BY METHOD SHOWN IN DETAILS MULCH I-2.5 x ROOTBALL DIAMETER — I SECTION TREE PLANTING DETAIL N.T.S. :I�Kel7_1�7� UNDISTURBEDOR COMPACTED SUB -GRADE PLANT QUANTITY CALCULATION EXAMPLE FOR 100 SO Fr. AREA C. 2' O.C. SPACING SQUARE SPACING: AREA (IN SQ Ff.) 100 = 25 QTY SPACING' (IN FEET) 2' TRIANGULAR SPACING: AREA (IN SO FT.)/0.86 100/0, 86 = 29 QTY SPACING' (IN FEET) 2� ZAS —PLANT LOCATION (TYP.) =O \ Q 6" @ GROUNDCOVER D NOTE: SPACING DIAGRAM REFERS TOALL PAVING EDGE/BUILDING/ PLANTING UNLESS NOTEDOTHERWISE. CURB/STEEL EDGING PLAN TRIANGULAR SPACING DETAIL N.T.S. (REF. PLANS) S" STEEL EL EDGING EDGING I" ABOVE GRASS rPLANTINGlGRAV� AREA II EXISTING SOIL SECTION STEEL EDGING AT PLANTING/GRAVEL N.T.S. NOTES: 1. PLANTING BED TO BE COMPLETELY OVER -EXCAVATED &FILLED WI BACKFILL MIXTURE 2. BEFORE LAYING PLANTING MIXTURE, SCARIFY SUBGRADE IN THE DIRECTION OF SLOPE FOR POSITIVE DRAINAGE 3. ALL LABELS TO BE REMOVED AFTER FIRST PUNCH INSPECTION KEEP MULCH AWAY FROM BASE OF PLANT 3" MULCH . SPACING AS PER PLANTING PLAN & SPACING CHART Iy171F9lmi:7_1S4 MIXTURE FYf1c7:L1S�l SECTION 6" MIN. STEEL E DGI NG AS REQUIRED BY OWNER (SEE DETAIL) PLANTS REMOVE CONTAINER & PRUNE ANY CIRCLING ROOTS PLANTING BED DETAIL N.T.S. T524 �24 L 1" TO 2" CALIPER 2 'v UNITS PERTREE TS36 2" TO 4" CALIPER - 3 - � UNITS PERTREE �42 3' TS42 4" TO 6" CALIPER - 3 iu UNITS PERTREE —� 12" taa TS48 NPCALIPER-3 UNITS A (V UNITS PERTREE 12" �T NOTES: 1. DETERMINE THE PROPER SIZE TREESTAPLE DEVICE BY MEASURING THE DEPTH OF THE ROOT BALL, BACKFILL MIX, AND DRAINAGE GRAVEL, PLUS ADDING 17'-18' INTO UNDISTURBED SUBGRADE. ROUND UPTOTHE NEXTSIZE IF NECESSARY. 2. IN EXTREME WIND AND/OR LOOSE SOIL CONDITIONS. USE THREE TREE STAPLE DEVICES PER TREE AND/OR ROUND UP TO THE N EXT SIZE. TREE STAPLE SIZE AND 1 QUANTITY GUIDE N.T.S. INSTALL SHORT PRONG HALFWAY BETWEEN TRUNK AND EDGEOFROOTBAU - UPHILL TREE REF. PLANTING PLANS PLAN INSTALL LONG PRONG UP AGAINST SIDE OF ROOTBALL TREE REF. PLANTING PLANS RECESS TREE STAPLE DEVICE 1" TO 2" INTO ROOT BALLTO FINISH BELOW GRADE TREE STAPLE: PER MANUFACTURERS RECOMMENDATIONS _7 TEL: (877) 8733749 12" MIN. INTO UNDISTURBED SUBGRADE SECTION TREE STAPLE - TWO STAPLE DETAIL N T S INSTALL SHORT PRONG HALFWAY BETWEENTRUNK AND EDGEOFROOTBALL - UPHILL PLAN TREE REF. PLANTING PLANS 12" MIN. INTO UNDISTURBED SUBGRADE INSTALL LONG PRONG UP AGAINST SIDE OF ROOT BALL TREE REF. PLANTING PLANS RECESS TREE STAPLE DEVICE 1" TO 2" INTO ROOT BALLTO FINISH BELOW GRADE SECTION TREE STAPLE: PER MANUFACTURERS RECOMMENDATIONS TEL: (877) 8733749 TREE STAPLE - THREE STAPLE DETAIL N.T.S. No.5076 # .RkANSP.`��`