18-008 Map 3
4*�� GRAPHIC SCALE IN FEET 20' 0 20' --------------------- ZONE SCHEDULE ZONE HEAD TYPE GPM 1 Turf Rotary 23.79 2 Turf Rotary 20.39 3 Drip Area 22.58 4 Drip Area 23.55 �f IRRIGATION NOTES I. ALL IRRIGATION SLEEVING UNDER PAVEMENTS SHALL BE 4" SCHEDULE 40 PVC (UNLESS - NOTED OTHERWISE) PLACED 18" - 24" BELOW FINISH GRADE. TAPE OR CAP ENDS SHUT. BACKFILL WITH CRUSHED LIMESTONE GRAVEL AND COMPACT ACCORDING TO EARTHWORK SPECIFICATIONS. MARK THE ENDS OF SLEEVES WITH WOOD STAKES OR STEEL'T' POSTS. VERIFY ACTUAL LOCATIONS ON SITE, 2. THIS IRRIGATION DESIGN IS BASED ON A DYNAMIC WATER PRESSURE OF 55 PSI @ 35 GPM. CONTRACTOR SHALL VERIFY AND NOTIFY LANDSCAPE ARCHITECT IF PRESSURE IS LESS THAN OR SIGNIFICANTLY HIGHER BEFORE PROCEEDING WITH INSTALLATION. 3. INSTALL RPZ IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE REGULATIONS. 4. AN INSULATED, FIBERGLASS ENCLOSURE IS TO BE INSTALLED OVER THE RPZ ASSEMBLY. 5. INSTALL CONTROLLER INSIDE BUILDING OR IF INSTALLED OUTSIDE IT MUST BE PLACED INSIDE OF A LOCKING ENCLOSURE. COORDINATE LOCATION WITH THE GENERAL CONTRACTOR. 6. APPROPRIATE SIZE VALVE BOXES ARE TO BE INSTALLED OVER ALL VALVES. 7. THE GENERAL CONTRACTOR TO PROVIDE ADEQUATE ELECTRICAL OUTLETS FOR ALL IRRIGATION CONTROLS. 8. CONTRACTOR SHALL OBTAIN ANY REQUIRED PERMITS, ADHERE TO ALL MUNICIPAL CODES AND FOLLOW STANDARD AND ACCEPTED LOCAL PRACTICES, 9. AN AUTOMATIC DRAIN VALVE SHALL BE INSTALLED AT THE LOWEST PORTION OF EACH ZONE AND AT 100, INTERVALS ON THE MAINLINE (SEE DETAIL). 10. THIS IRRIGATION DESIGN IS DIAGRAMMATIC ONLY. THE INTENT OF THIS DESIGN IS TO SHOW THE GENERAL LAYOUT AND LOGIC OF THE SYSTEM. SCALED MEASUREMENTS, QUANTITIES AND ACTUAL LOCATION OF EQUIPMENT MAY VARY DUE TO FIELD ADJUSTMENTS. PIPING LAYOUT IS SCHEMATIC. LOCATE HEADS, LINES AND WIRING ALONG BACK OF CURBS AND BED EDGES. COMBINE LINES AND WIRING IN COMMON TRENCHES WHERE POSSIBLE. PLACE HEADS DIRECTLY ADJACENT TO CURBS AND EDGES. PLACE VALVES IN ACCESSIBLE LOCATIONS. NO LINES ARE TO BE PLACED UNDER VEHICULAR PAVING AREAS UNLESS IN IRRIGATION SLEEVES. 11. PROVIDE 100% COVERAGE FOR ALL LANDSCAPE AREAS AND MAKE FINAL ADJUSTMENTS TO OBTAIN OPTIMAL PERFORMANCE. 100% COVERAGE WILL BE DEFINED AS HAVING HEAD TO HEAD COVERAGE IN ALL DIRECTIONS AND IN ALL AREAS. THERE SHALL BE NO SHRUB HEADS PLACED ON THE SAME ZONE WITH TURF HEADS. THERE SHALL BE NO TURF HEADS PLACED ON THE SAME ZONE WITH SHRUB HEADS. 12. REVIEW AND REPORT ANY DISCREPANCIES SHOWN ON THE PLAN, FOR CORRECTION, PRIOR TO PROCEEDING WITH RELATED WORK. 13.INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS DETAILS AND SPECIFICATIONS. 14. PLACE ALL PIPING ON THE PERIMETER OF LANDSCAPE AREAS WHERE POSSIBLE. PLACE VALVES IN PLANTING AREAS WHERE POSSIBLE. LIMIT TRENCHING AROUND EXISTING TREES AS MUCH AS POSSIBLE, BE AWARE OF THE LOCATION OF NEW TREES AND SHRUBS AND PLACE PIPING AWAY FROM THE ROOT BALLS. 15. ALL SPRAY HEADS IN PLANTING BEDS ARE TO BE 12" POP -UPS. ALL SPRAY AND ROTARY HEADS IN LAWN AREAS TO BE 4" POP-UP MINIMUM. 16, CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ALL UTILITIES DURING THE INSTALLATION. CGNTRACTOR SHALL CONFIRM THE LOCATION OF THE UTILITIES PRIOR TO STARTING ANY WORK. THE CCNTRACTOR IS RESPONSIBLE FOR CONTACTING THE ONE -CALL SYSTEM @ 1-800-482-8998. ALL UTILITY LOCATIONS SHOWN ARE APPROXIMATE AND ARE BASED ON SURVEY INFORMATION, SITE DEVELOPMENT PLANS, UTILITY RECORDS, ETC. I TSOME PIPING MAY BE SHOWN OFF PROPERTY OR OUTSIDE OF SLEEVES FOR GRAPHIC PURPOSES ONLY. PLACE ALL IRRIGATION COMPONENTS ON THE PROPERTY AND IN APPROPRIATE SLEEVES. IRRIGATION -SCHEDULE SYMBOL MAN UFACTURER/MODELIDESCRIPTION CITY DETAIL HUNTER MP1000 PROS-04-PRS40-CV 58 0 O S TURF ROTATOR, 4" (10.16 CM) POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC. HUNTER MP2000 PROS-04-PRS40-CV 3 QQQR TURF ROTATOR, 4" (10.16 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC. HUNTER MP800SR PROS-04-PRS40-CV 27 ® m TURF ROTATOR, 4.0" POP-UP WITH CHECK VALVE, PRESSURE ADJ. 360 REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY, ADJ=ORANGE AND GRAY ( ARC 90-210), 360=LIME GREEN AND GRAY (ARC 360) HUNTER MP CORNER PROS-04-PRS40-CV 2 TURF ROTATOR, 4" (10.16CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. T=TURQUOISE ADJ ARC 45-105 ON PRS40 BODY. HUNTER MP STRIP PROS-04-PRS40-CV 23 ®®® TURF ROTATOR, 4" (10.16 CM) POP-UP WITH FACTORY INSTALLED LST RST SST CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. LST=IVORY LEFT STRIP, SST=BROWN SIDE STRIP, RST=COPPER RIGHT STRIP. SYMBOL MANUFACTURERIMODELIDESCRIPTION QTY HUNTER ICZ-151-40 2 DRIP CONTROL ZONE KIT. 1-1/2" ICV GLOBE VALVE WITH 1" HY100 FILTER SYSTEM. PRESSURE REGULATION: 40PSL FLOW RANGE: 20 GPM TO 60 GPM. 120 MESH STAINLESS STEEL SCREEN. PIPE TRANSITION POINT IN DRIP BOX 12 PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP TUBING WITH RISER IN 6" (150MM) DRIP BOX. HUNTER PLD-AVR 2 1/2" THREADED AIRIVACUUM RELIEF VALVE AREA TO RECEIVE DRIPLINE HUNTER PLD-10-12 IN -LINE PRESSURE COMPENSATING LANDSCAPE DRIPLINE WITH BUILT-IN CHECK VALVE, 1.0 GPH EMITTERS AT 12" O.C. DRIPLINE LATERALS SPACED AT 12" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. UV RESISTANT. USE PLD-LOC FITTING OR BARBED FITTINGS. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY BUCKNER-SUPERIOR 100 2 3/4", 1", 1-1/4", 1-1/2", 2", 2-1/2", AND 3" NORMALLY OPEN BRASS HYDRAULIC VALVE WITH A FORWARD FLOW DESIGN. 2-PIECE DIAPHRAGM. BUCKNER-SUPERIOR VBM 1 ® BRASS MANUAL ANGLE VALVE IN 3/4", 1", 1-1/4", 1-112", AND 2". REMOVABLE BONNET AND INTERNAL ASSEMBLY FOR EASY SERVICE AND CLEANING. SAME SIZE AS MAINLINE. MV HUNTER ICV-G 1-1/2" 1". 1-1/2", 2", AND 3" PLASTIC ELECTRIC MASTER VALVE, GLOBE 1 CONFIGURATION, WITH NPT THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE. BF FEECO 825YA 1-1/2" REDUCED PRESSURE BACKFLOW PREVENTER 1 © HUNTER XCH-0400 ELECTROMECHANICAL CONTROLLER, 4 STATIONS, INDOOR/OUTDOOR 1 MODEL, BATTERY -POWERED. PLASTIC CABINET, FOR RESIDENTIALICOMMERCIAL USE. WATER METER 1" 1 M IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 ___---_____ IRRIGATION MAINLINE: PVC SCHEDULE 40 PIPE SLEEVE: PVC SCHEDULE 40 - - Valve Callout # Valve Number #" # Valve Flow Valve Size * ALL QUANTITIES ARE APPROXIMATE ONLY, CONTRACTOR SHOULD VERIFY EXACT QUANTITIES PRIOR TO BIDDING AND INSTALLATION. * SEE SHEET U-501 & LI-502 FOR IRRIGATION DETAILS 10825 Financial Centre Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull ® engineering I surveying 501.664,3245 t 501.664.6704 f www.craftontull.com Zoe W >R1 Go. ZZ Qom• • Oh113) C3N LN UO8 • • LL 1 Q " 00 - j EO W¢8 NUIN Cl W J�Z U� �w Q N w Z J w U Cn I Y Z z Cn C0 W Y Q W Y Y" LL U O U c=n W J Q J DATE: 14 DEC 2017 PROJECT NO: 17078 DRAWN BY: RPIAllA REVISION: LI1.0