Loading...
HomeMy WebLinkAboutS-1859 Staff AnalysisJanuary 9, 2020 ITEM NO.: A FILE NO.: S-18 NAME. QuikTrip Site Plan Review LOCATION: Southwest of the intersection of Bass Pro Parkway and Otter Creek Road DEVELOPER: Daniel Chambers QuikTrip Corporation 4705 South 129th East Avenue Tulsa, Oklahoma 74134 OWNER/AUTHORIZED AGENT: Fletcher Realty LLC/Owner Derek Ballbergen, S&ME Inc./Authorized Agent SURVEYOR/ENGINEER: Derek Ballbergen, S&ME Inc./Engineer AREA: 15.77 acres nM-9 CURRENT ZONING VARIANCEM/AIVERS: NUMBER OF LOTS: 1 PLANNING DISTRICT: 16 C-4 FT. NEW STREET: 0 LF CENSUS TRACT: 41.03 1. Sections 30-43 and 31-210: Driveway locations and widths 2. Section 15-97: Vehicular Use Area Interior Landscaping 3. Section 15-98: Building Area Perimeter Landscaping BACKGROUND: This site is a vacant undeveloped tract zoned C-4 and located south of Otter Creek Road and west of Bass Pro Parkway. Containing approximately 15.77-acres of land the site is largely paved and was previously used by a trucking concern. The site also abuts the Interstate 30 frontage road. Northwest of the property is the recently developed commercial center anchored by Bass Pro and the Outlets of Little Rock. January 9, 2020 SUBDIVISION ITEM NO.: A Cont. FILE NO.: S-1859 As the proposed use is permitted in the C-4 district and multiple buildings are proposed, this request is for a site plan review. A PROPOSAL/REQUEST/APPLICANT'S STATEMENT: The applicant is proposing to develop a travel plaza/fueling station. The proposed use is allowed in the C-4 zone. The site is located near major traffic routes making it desirable for the developer to bring the travel plaza/fueling station to the property. Any existing pavement would be removed and any utility service lines not necessary for the new development would be removed during the site preparation and grading. The new development is proposed to be connected to each of the QVUIIII II,. IVQVVV ayJ VIQ iiVG iJi1YGJ. The new building would be approximately 8,292 square feet in area, additionally there would be a trash pad and enclosure, fuel pumps and canopies, as well as a truck scale. Si_ a 1.. L-ra : ]_ i - s d fr.. sta g ns Sigh on hte Sit Ylf tl iJ i�1 iricieade eriil CX a UI iwu aril.? iic@Siaridiiig �:o �iyiiJ. B. EXISTING CONDITIONS' The subject parcel is largely paved; however, is not developed with any structures. The property to the west contains an equipment/truck rental use. Further west is a church situated on a sizeable parcel that remains heavily covered in woods. Across Otter Creek Boulevard is a fuel center/truck stop with a convenience store and restaurant. Additional commercial uses are found to the northeast of the site. Interstate 30 is situated to the south and east generally. Industrial uses dominate the area on the opposite side of the highway. The overall area is characterized by uses oriented toward commercial uses and a significant portion would be considered to be primarily used by travelers using Interstate 30. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has had some communication with representatives of area neighborhood associations. Some concern has been expressed about traffic circulation and possible additional congestion from this development. Notice of the public hearing was sent to all owners of properties located within 200 feet of the site and the Southwest Little Rock United for Progress neighborhood association. 2 January 9, 2020 SUBDIVISION ITEM NO.: A (Cont.) FILE NO.: S-1.859 D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Sidewalks with appropriate handicap ramps are required along Otter Creek Road to the west property line in accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan. 2. Obtain permits for improvements within State Highway right-of-way from AHTD, District VI. 3. A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. 4. Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or owner. 5. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 6. A special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior to construction. 7. The minimum Finish Floor elevation of at least 1 ft. above the base flood elevation is required to be shown on plat and grading plans. 8. In accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25-foot-wide drainage and access easement is required adjacent to the floodway boundary. 9. Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 10. On site striping and signage plans should be forwarded to Public Works, Traffic Engineering for approval with the site development package. 11. Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more information. 12. Driveway locations and widths do not meet the traffic access and circulation 3 January 9, 2020 SUBDIVISION ITEM -NO.- A (Cont.) FILE NO.: 5-1859 requirements of Sections 30-43 and 31-210. The width of driveway must not exceed 35 feet. Driveway spacing on arterial streets is 300 ft. between driveways and from intersections and 150 ft. trorm side property lines. Variances must be requested for the proposed driveway locations. Sta ii cannot recommend approval of the driveway within the Utter Creek Rd EB right turn lane. 13. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 14. The 1-30 frontage road driveways should be one way. Signage should be installed to prevent left turns. 15. The proposed right in/right out driveway island should be truck mountable. E. UTILiTIES1FIRE DEPARTIVEN T /P ARKSfCOUN T Y PLANNIN& Little --Rock Water Reclamation Authod : --Sewer main extension required -with easements if new sewer service is required for this project. FOG Analysis FIX c.. quired . Entergy: Entergy does not object to this proposal. There does not appear to be any conflicts with existing electrical utilities at this location. Three phase lines are located along Otter Creek. Contact Entergy in advance to discuss electrical service requirements, or adjustments to existing facilities (if any) as this project proceeds. CenterPoint Energy: No comment. AT & T: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. 4 January 9, 2020 SUBDIVISION ITEM NO.: A Cont. FILE NO.: S-1859 Fire Department: Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. 5 January 9, 2020 SUBDIVISION ITEM NO.: A Cont. FILE NO.: S-1859 Dead Ends. Rlaintsin fire arennnntim access roads nt ripad Pnd locations as ner Appendix v of the 2012 rirkuiisas Fare Pre .`r'atlol'ra?:Sim Vol. 1 Coctinei Pl°lil,d P4pari Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirenn.ents cU-r Dead-end fire n�r arnfIS aS^.emsS roars. _ Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757 nr (a,nt. John Hogue591-918-3754)_ Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. Count Planning: No comment received. F. BUILDING CODESILANDSCAPE: Building Code: r-__ • _ t subject t- Ifull 1 plan d I � �o issu 11nc of irC�jeC.l is JLI L1�Cl:l LU IUII I,UIIIII1Cll.lal s.J10111 IGVICYV ailu approval �:.,rivr av iJJu�ai ia... are a building permit. For information on submittal requirements and the review process, contact a commerciai plans examiner: Curtis Richey at 501.371.4724; cricheVQIittierock.gov or Steve Crain at 501-371-4875; scrain iittlerock. ov La,ndscam 1. Any new site development must comply with the City's minimal landscape and buffer ordinance requirements. 2. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half (1/) the full width requirement but in no case less than nine (9) feet. The maximum dimension required shall be fifty (50) feet. The approximate average width and depth of the lot is 500 feet. A minimum thirty-foot (301 street buffer will be required ad'acent to the riahts-of-way on north south and east sides of the property. t. January 9, 2020 SUBDIVISION ITEM NO.. A Cont. FILE NO.: S-1859 The east street buffer and portions of southeast and northeast buffers are deficient. 3. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street, highway or freeway. This strip shall be at least nine (9) feet wide. The perimeter planting strip adjacent to freeways or expressways shall be at least thirty (30) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. A portion of the perimeter planting strip adjacent to the northeast right of-way's less than the minimum nine (9) foot requirement. 4. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-way. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. 5. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty (150) or fewer parking spaces. Interior islands must be a minimum of seven and one half (7 1 /2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. Interior landscape areas may be deficient. 6. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building. 7. An irrigation system shall be required for developments of one (1) acre or larger. 8. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. 9. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance 7 January 9, 2020 SUBDIVISION ITEM NO.: A Cont. FILE NO.: 5-1859 regUife-MU t, iJ� tJ-lveli VVIlc1t � lur ,Clvliig LIeC3 o1 si:. i'�l iilCll callP�l or larger. /— T AhIL�I'l /�I�T Ir'1 AI lr11 AAII� IAIl�• 0. 1 Rr,IV�rVrt 1ATIUIVlr LeuV I� I I V V. Rock li,ry{Uil IVICLIU. I'd t.Vlillllellt. Planning Division: No comment. H. SUBDIVISION COMMITTEE COMMENT: September 18, 2019 The applicant was present. Staff presented the item. The Planning Department requested the site plan show 45-foot setbacks from all rights -of -way and no less than 15 feet on the rear. A specific signage plan was also asked of the applicant. The Public Works comments regarding the requirement for sidewalks along Otter Creek Road, stormwater detention, driveway locations, and making the driveways to 1-30 one wav were noted. Landscaping comments pointed out included the deficiencies in the proposed street buffer widths and interior landscape areas were also not compliant. Responses to comments and issues with revisions were required no later than September 25, 2019. I, ANALYSIS: A rpvisPci site plan has hPPn submitted in response to the subdivision committee comments. Building setbacks have been added, showing the front and side yards as no less than 45-feet and the rear yard no less than 15-feet. A sign plan has been provided. The proposed signage is as follows: A "high-rise" pole sign is shown near the intersection of Bass Pro Parkway with the Interstate 30 frontage road. This sign is indicated on the plans as 46-feet in height and 171.34-square feet in area. The applicant has indicated this sign would comply with the maximum allowed height and area of freestanding signs in commercial districts being 36-feet in height and 160-square feet in area, with the possibility additional height allowed under Section 36-557(b) whereby the height of a ground -mounted on -premises sign located on a property adjacent to and contiguous with an expressway or freeway may be measured from the elevation of the centerline of the n January 9, 2020 SUBDIVISION ITEM NO_: A Cont. FILE NO.: S-1859 traffic lanes (excluding frontage roads) adjacent to the subject property to the top of the sign structure. 2. A pole sign with a height of 35-feet is proposed slightly east of the western drive connecting to Otter Creek Road. The area of this sign would be 134- square feet. 3. Building signage would compliance with the commercial building standards. 4. Various directional signs would be placed adjacent to the access drives to provide guidance on available services and to assist in separating automobiles from semi -trucks. Sidewalks and appropriate accessible ramps have been added to the site plan and would be constructed along Otter Creek Road to the west property line in compliance with the City standards and the Master Street Plan. A grading permit would be obtained prior to any land clearance or grading activities are commenced at the site. Stormwater detention will be provided on -site. The proposed detention pond has been added to the site plan along the western edge of the property. Specific plans meeting standards would be finalized and approved during the permitting process. The base flood elevation at this site is estimated to be approximately 296 feet. The proposed building elevation is 308.50 feet, placing it more than one -foot above the base flood elevation. Plans for street improvements and signage, as well as on -site striping and signage will be reviewed and approved by Public Works prior to the onset of construction. Five access drives are shown on the site plan. Two drives are proposed to connect to the Interstate 30 frontage road. They are both 40-feet in width as they are likely to be used by semi -trucks and require additional width to accommodate the turning widths for semi -trucks. The connections to the frontage road are existing and would be improved with this development. One drive would extend to Bass Pro Parkway. This drive would be "right in/right out" and have a truck mountable island to enforce those movements. Two drives are proposed for Otter Creek Road. The drive closer to the intersection with Bass Pro Drive has been shifted west at the direction of Public Works to remove it from the right-hand turn lane for vehicles turning from Otter Creek Road onto Bass Pro Parkway. A permit would be required from ArDOT for this drive. Public Works has indicated the new location is still within the taper for the right -turn lane and the recommend the driveway be moved further west. The second driveway on Otter Creek Road is less than 150-feet from the property line requires a variance; however, it lines up with the driveway for the 9 January 9, 2020 SUBDIVISION ITEM NO.: A _(Cont. FILE NO.: 5-1859 property opposite Otter Creek Roaa anU this is a iilore desirable con filyilrationl thain having the drive not aligned. This driveway also has a width proposed at 40-feet. The additional width would allow for semi -trucks to better manage left turns into the site. The UIrecLional signs at the Drives I.UIIIIC4tl1 It tlJ tIIG Inter JLQ tc w frontage road would also advise motorists that left turns are not permitted on to the one-way frontage road. The initial plan submittal did not provide a full street landscape buffer. The revised site plan now complies. Also, the perimeter planting strip for vehicular areas abutting adjoining properties or rights -of -way has been revised for compliance. The minimum 9-foot wide strip is now shown on the plan along Bass Pro Parkway. The required screening materials will also be provided within the buffers between the vehicular use areas and rights -of -way. A variance is requested to not provide all of the required green space of 8°Io of the vehicular area as green space. As the site will be used by larger vehicles, there must be sufficient space for these vehicles to circulate. The landscaping plan does provide landscaping islands within the area uesignatea for automobile use EaiRd . Oho hliffnr aYtancionc hrarkatinn the sPmi-trijr.k narking area meeting the intent of the requirement. Another variance is requested for the building landscape areas. Landscape variances require the approval of the City Beautiful Commission. It appears all other technical issues have been addressed. Staff is supportive of this use of the property and the applicant has modified the site plan to balance the operational requirements of the use of the site as a travel plaza/fueling center with the technical standards of the various development codes. STAFF RECOMMENDATION: Staff recommends approval of the site plan subject to compliance with the comments and conditions outlined in paragraphs D, E, and F of the agenda staff report. i[7 January 9, 2020 SUBDIVISION ITEM NO.: A(Cont.)FILE NO.: S-1859 Staff also recommends approval of the variances to allow the driveways as shown on the site plan, subject to ARDoT approval. PLANNING COMMISSION ACTION: (NOVEMBER 21, 2019) The applicant was not present. There were no registered objectors present. Staff informed the commission that the applicant did not provide a complete set of revisions or responses to sufficiently address the Subdivision Committee comments; therefore, the request should be deferred to January 9, 2020. There was no further discussion. The item was placed on the consent agenda and deferred to the January 9, 2020 agenda. The vote was 10 ayes, 0 noes, and 1 absent. PLANNING COMMISSION ACTION: (JANUARY 9, 2020) The applicant was present. There was one registered objector present. Staff presented the item and a recommendation to approve the site plan as outlined in the "staff recommendation" above. Commissioner Brock inquired of the applicant whether the approvals required for some of the site access driveway connections had been obtained from the Arkansas Department of Transportation (ArDOT). Daniel Chambers of QuikTrip Corporation responded they are working with ArDOT to gain approval. The initial site plan was revised based upon the issues raised in the review process. In conversation today, ArDOT staff requested the east drive onto Otter Creek Road be shifted further to the west to remove it from the taper for the right turn lane. This request can be accommodated by the developer. Commissioner Brock added the traffic on Otter Creek Road turning onto 1-30 tends to back up and that he is concerned this project would make the issue worse. Mr. Chambers replied they are both aware of the traffic issues in the area and share the concern. They have revised the site plan to in response to the conditions and concerns to accommodate the existing traffic and not to create additional problems. Troy Laha addressed the commission stating he was opposed to the proposed driveway layout. He has been to other locations operated by the developer and has some understanding of how the property would operate. He would like the access drive to Bass Pro Parkway removed, as drivers will not adhere to the "right-in/right out" design and attempt to make left turns into and out of the site. The drives onto Otter Creek will have the same issue of drivers attempting left turns. He believes the site would work with just three access drives. 11 January 9, 2020 SUBDIVISION 1TEM NO.: A Cont. FILE NO.: S-1859 ee-'----t 11__:__--.: _... Lal__ trafr:_ is..ues rl:.-....♦•...-l�..Ili...S Commissioner Haynes asked s`[ati a1Dout ulei ICview of h Li dIIIL; 13.7U C.9. LJiI=%1LUi L.IU1111 responded the initial concerns are about vehicle stacking and getting on or off the property and the understanding that there will be traffic associated with any development. Mike r�. .I_I•_ Ini__._ r1 .1.Y a C...LL. .... I .J �L. 4 Public 1A/i.rL, n4 fF'p--+ � Hood of the Pu[Jllc VVUIks Depal ment IUILIICI CxpIaIneU 1.11 L PUUIIL. vvVlf�O .7La11 JNcllL } f _ ir- reviewing this nrnimf4 The cit= plan has. been nevi--- to significant amount I1J 1.111E vl tiI 11G Ili I evlc. dVn ig LI n.� VI vj-. v v addf�SS U1 C:onCelflS brought up on tl C initial plan. The Gast Wive vn Otter essentially complies with standards. Mr. Hood indicated ArDOT has expressed some concern about the access drive to Bass Pro Parkway and there is the possibility it may not be approved. There was no further discussion and Chairman Latture called for a motion. Vice Chairman Hamilton made a motion to approve the site plan as submitted with the staff recommendation for approval. Commissioner Betton seconded. The vote was 8 ayes, 2 noes, and 1 absent. 12 November 21, 2019 ITEM NO.: A FILE NO.: S-1859 NAME: QuikTrip Site Plan Review LOCATION: Southwest of the intersection of Bass Pro Parkway and Otter Creek Road DEVELOPER: QuikTrip 4705 South 129th East Avenue Tulsa, Oklahoma 74134 OWNER/AUTHORIZED AGENT: Fletcher Realty LLC./Owner Phillip Lewis/Authorized Agent SURVEYOR/ENGINEER: Brooks Surveying, Inc./Surveyor Phillip Lewis Engineering, Inc./Engineer AREA: 15.77 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF WARD: 7 PLANNING DISTRICT: 16 CENSUS TRACT: 41.03 CURRENT ZONING: C-4 VARIANCE/WAIVERS: 1. Allow for reduced perimeter landscaping strip. 2. Allow for reduced interior parking area landscaping. 3. Driveway spacing. PLANNING COMMISSION ACTION The applicant was not present. There were no registered objectors present. Staff informed the commission that the applicant did not provide revisions or responses to the Subdivision Committee comments by September 25, 2019; therefore, the request should be deferred to the November 21, 2019 meeting. There was no further discussion. The item was placed on the consent agenda and deferred to the November 21, 2019 agenda. The vote was 9 ayes, 0 noes, and 2 absent. November 21, 2019 SUBDIVISION ITEM NO.: A (Cont.) FILE NO.: S-1859 STAFF UPDATE AND RECOMMENDATION: The applicant did not provide a complete set of revisions or responses to sufficiently address the Subdivision Committee comments. Staff recommends deferral of this item to the January 9, 2020. PLANNING COMMISSION ACTION: (NOVEMBER 21, 2019) The applicant was not present. There were no registered objectors present. Staff informed the commission that the applicant did not provide a complete set of revisions or responses to sufficiently address the Subdivision Committee comments; therefore the request should be deferred to January 9, 2020. There was no further discussion. The item was placed on the consent agenda and deferred to the January 9, 2020 agenda. The vote was 10 ayes, 0 noes, and 1 absent. October 10, 2019 ITEM NO.: 3 NAME: QuikTrip Site Plan Review FILE NO. S-1859 LOCATION: Southwest of the intersection of Bass Pro Parkway and Otter Creek Road DEVELOPER: QuikTrip 4705 South 129t" East Avenue Tulsa, Oklahoma 74134 OWNER/AUTHORIZED AGENT: Fletcher Realty LLC./Owner Phillip Lewis/Authorized Agent SURVEYOR/ENGINEER: Brooks Surveying, Inc./Surveyor Phillip Lewis Engineering, Inc./Engineer AREA: 15.77 acres WARD: 7 CURRENT ZONING: VARIANCE/WAIVERS: NUMBER OF LOTS: 1 PLANNING DISTRICT: 16 W1 1. Allow for reduced perimeter landscaping strip. 2. Allow for reduced interior parking area landscaping. 3. Driveway spacing. STAFF UPDATE AND RECOMMENDATION: FT. NEW STREET: 0 LF CENSUS TRACT: 41.03 The applicant did not provide revisions or responses to the Subdivision Committee comments by September 25, 2019. Staff recommends deferral of this item to the November 21, 2019 meeting. October 10, 2019 SUBDIVISION ITEM NO.: 3 Cont. FILE NO.: S-1859 PLANNING COMMISSION ACTION: (OCTOBER 10, 2019) The applicant was not present. There were no registered objectors present. Staff informed the commission that the applicant did not provide revisions or responses to the Subdivision Committee comments by September 25, 2019; therefore, the request should be deferred to the November 21, 2019 meeting. There was no further discussion. The item was placed on the consent agenda and deferred to the November 21, 2019 agenda. The vote was 9 ayes, 0 noes, and 2 absent. 2 October 10, 2019 ITEM NO. 3 FILE NO.: S-1 NAME: QuikTrip Site Plan Review LOCATION: Southwest of the intersection of Bass Pro Parkway and Otter Creek Road DEVELOPER. QuikTrip 4705 South 129t" East Avenue Tulsa, Oklahoma 74134 OWNER/AUTHORIZED AGENT: Fletcher Realty LLC./Owner Phillip Lewis/Authorized Agent SURVEYOR/ENGINEER Brooks Surveying, Inc./Surveyor Phillip Lewis Engineering, Inc./Engineer AREA: 15.77 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF WARD: 7 PLANNING DISTRICT: 16 CENSUS TRACT: 41.03 CURRENT ZONING: C-4 VARIANCEIWAIVERS: 1. Allow for reduced perimeter landscaping strip. 2. Allow for reduced interior parking area landscaping. 3. Driveway spacing. STAFF UPDATE AND RECOMMENDATION The applicant did not provide revisions or responses to the Subdivision Committee comments by September 25, 2019. Staff recommends deferral of this item to the November 21, 2019 meeting. October 10, 2019 SHRDIVISiON ITEM NO.: 3 (Cont.) FILE NO.: S-1859 PLANNING COMMISSION ACTION: (OCTOBER 10, 2019) The applicant was not present. There were no registered objectors present. Staff informed the commission that the applicant did not provide revisions or responses to the Subdivision Committee comments by September 25, 2019; therefore, the request should be deferred to the November 21, 2019 meeting. There was no further discussion. The item was placed on the consent agenda and deferred to the November 21, 2019 agenda. The vote was 9 ayes, 0 noes, and 2 absent. 2 Alex Koenig Development Administrator City of Little Rock Planning & Development Department 723 Markham Blvd Little Rock, AR 72201 (501) 371-6821 RE: 5-1859 QuikTrip Site Plan Review Comment Response Letter Alex, Below are the comment responses. Planning Staff Comments: 1. Provide notification of the (abutting property owners/property owners within 200-feet of the site) including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than September 25, 2019. The Office of Planning and Development must receive the proof of notice no later than October 4, 2019. Response: Mailings have been sent out with response cards. Signed affidavit is attached with this submittal 2. Building setbacks on site plan should be 45 feet from all rights -of -way and no less than 15 feet on the rear. Response: Added the setbacks on the Site Plan 3. Provide a specific signage plan. Response: Signage Plan has been included in the re -submittal Engineering Comments: Public Works Conditions: 1. Sidewalks with appropriate handicap ramps are required along Otter Creek road to the west property line in accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan. Response: Sidewalk and ADA ramps have been added in conformance with Sec 31-175 of the Little Rock Code and Master Plan 2 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI. Response: QuikTrip is actively working with DOT to obtain permits 3. A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and provided prior to the start of construction. Response: Understood. A grading permit is required and will be pulled before any land clearing activities are started 4. Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private Response: Fire access roads will be maintained along with fire hydrants Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Response: Driveways and site grading will not exceed a slope of 10%. Loadine Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Response: Building access will be accessible to fire department apparatus. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Response: Building height is 20 ft. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Response: Building area is 8,292-sf. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. Response: Noted. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead- end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Response: Noted. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — Landscape: Any new site development must comply with the City's minimal landscape and buffer ordinance requirements. Response: Noted. 2. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half (%) the full width requirement but in no case less than nine (9) feet. The maximum dimension required shall be fifty (50)feet. The a pproximate avers a width and de pth of the lot is 500 feet. A minimum thin -foot 30 street buffer will be req aired ad -scent to the ri hts-of -way on north south and east sides of the oronerty. The east street buffer and portions of southeast and northeast buffers are deficient. Response: Site layout has been revised to show minimum buffer widths of 30-ft. 3. A perimeter plantingstrip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street, highway or freeway. This strip shall be at least nine (9) feet wide. The perimeter planting strip adjacent to freeways or expressways shall be at least thirty (30) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter plantingstrip. A portion of the perimeter planting strip adjacent to the northeast right-of-way's less than the minimum nine (91 foot requirement. Response: Site layout has been revised to show the minimum required buffer widths. 4. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-way. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30)feet. Response: Screening shown on landscape drawing. 5. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty (150) or fewer parking spaces. Interior islands must be a minimum of seven and one half (71/2) feet in width. Trees shall be included in the interior landscape areas atthe rate of one (1) tree for everytwelve (12) parking spaces. Interior landscape areas may be deficient. Response: A variance is requested from this requirement. (Should the end caps on the parking island be counted, this requirement is met. If not, a variance is requested.) 6. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building. Response: A variance is requested from this requirement. 7. An irrigation system shall be required for developments of one (1) acre orlarger. Response: An irrigation system will be included in the final design documents. 8. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. Response: Final design documents will be signed and sealed by a Registered Landscape Architect. 9. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. Response: Noted. Transportation/Planni ne: Rock Region Metro: No comment Planning Division: No comment Revised plat/plan: Submit responses to staff issues and four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on or before September 25, 2019. If you have any questions please contact Alex Koenig, akoeni _ @littierock.poy or 501.371.6821 or Dana Carney, dcarnev@littlerock.gov or 501.371.6817. If there is any additional information that is needed, feel free to contact me. Thanks, 0—j 6'� Daniel Chambers QuikTrip Corporation 4705 South 129th East Ave Tulsa, OK 74134 (918) 615-7147 daniel.chambers uiktri .com