Loading...
HomeMy WebLinkAboutS-1828 Staff Analysis901 N 47th Street, Suite 200 Rogers, AR 72756 Crofton Tull architecture I engineering I surveying October 17, 2018 Subdivision Committee City of Little Rock 500 W. Markham St. Little Rock, AR 72201 501-371-4510 Re: Lanehart/McPherson Subdivision Below are responses to the received list of comments. 479.636.4838 (ph) 479.631.6224 (fax) Planning Staff Comments: 1. Provide notification of the abutting property owners including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than October 16, 2018. The Office of Planning and Development must receive the proof of notice no later than October 26, 2018. Notification provided. 2. Correct the zoning classification labels. The abutting zoning classifications should be R-2, Single-family. The property at the southeast corner of the site owned by Christopher Homes of Little Rock is zoned PD-R. Zoning classification corrected. 3. There are additional variances for lot widths require. Corner lots should be 75-feet in width. It appears Lots 26 and 27 are less than 60-feet at the building line. Lot widths corrected. 4. Provide a no right of vehicular access easement along the street frontages. The easement should be 10-feet in width. Easement provided. 5. Provide the proposed phasing plan for the proposed plat area. Will the lots be developed in a single or multiple phase? If multiple phases include a note in the general notes section of the proposed preliminary plat indicating the phasing plan. Subdivision will not be phased. 6. Provide the location of the proposed USPS mail kiosk. Location provided. 7. The platted building lines on all corner lots should be 25-feet. Corrected. 8. Remove the platted side and rear yard platted building lines. Lines removed. 9. Six (6) foot fences are not allowed in the setback adjacent to the streets. Noted. 901 N 47th Street, Suite 200 Rogers, AR 72756 Crafton Tull ® architecture I engineering I surveying Variance/Waivers: 479.636.4838 (ph) 479.631.6224 (fax) 1. A variance from the Land Alteration Ordinance to allow grading of the lots with the installation of the basic infrastructure. The subdivision will be developed in one phase. All lots will be graded with the installation of basic infrastructure. 2. A variance from 36-254 to allow lot widths, interior lot widths and corner lots, less than the typical ordinance standard. Also to allow platted building lines less than the typical ordinance standard. The affected lots are: 1-13, 18-20, 23, 24, 26, 27, 34, 36, 41 and 43. A total of 24 lots are less than 60' at the building line. We are also requesting a reduced setback width for Lot 1. Engineering Comments: Public Works Conditions: 1. McPherson Road is classified on the Master Street Plan as a residential street. A dedication of right-of-way 25-feet from centerline will be required. Noted. 2. Lanehart Road is classified on the Master Street Plan as a collector street. A dedication of right-of-way 30-feet from centerline will be required. Noted. 3. The west end of "Street 1" to McPherson Road is not classified as a loop street and should be constructed to a residential standard street section with a minimum of 26-feet of pavement within a 50-foot right-of-way. Corrected. 4. "Street 5" is not classified as a loop street or cul-de-sac and should be constructed to a residential standard street section of minimum 26-feet within a 50-foot right-of-way. Corrected. 5. Sidewalks with appropriate handicap ramps are required to be installed on the west end of "Street 1" and along "Street 5" in accordance with Section 31-175 of the Little Rock Code of Ordinances and the Master Street Plan. Added. 6. A 20-foot radial dedication of right-of-way is required at the intersection of Lanehart Road and McPherson Road. A 20-foot radial right-of-way dedication is required at all proposed street intersections. Added. 7. With site development, provide the design of street conforming to the Master Street Plan. Construct one-half street improvement to Lanehart Road including 5-foot sidewalks with the planned development. The new back of curb should be placed 18-feet from center of the existing street. Street improvement included. 8. Repair or replace any curb, gutter, sidewalk and access ramps that are damaged and not in compliance with ADA recommendations in the public right-of-way prior to occupancy. Understood. 901 N 47th Street, Suite 200 Rogers, AR 72756 C ra fto n Tu I I archiledure I engineering I surveying 479.636.4838 (ph) 479.631.6224 (fax) 9. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is a variance being requested to advance graded future phases with the first phase? Is a variance being requested to grade the lots with the street construction? Understood. Subdivision will be completed in one phase. 10. Provide a Sketch Grading and Drainage Plan with proposed pipe and ditch locations per Section 29-186. Sketch dragging and drainage plan provided. 11. Stormwater detention ordinance applies to this property. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owners association and detailed in the bill of assurance. Understood. 12. Access to detention ponds must be provided to the public right-of-way and/or access easement for future maintenance by the developer and/or local property owners association. Access provided. 13. Per Section 29-102 an evaluation should be conducted on the basis of existing downstream development and any analysis of stormwater runoff with and without the proposed development. If the proposed development will cause or increase downstream flooding conditions, provisions to minimize such flooding conditions should be included in the design of the storm management improvements. Such provisions may include downstream improvements and/or detention of stormwater runoff and it regulated discharge to the downstream storm drainage system. Evaluation preformed and results shown in drainage report. 14. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. Understood. 15. Street improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. Noted. 16. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons, simmons littlerock, ov or 501.379.1813 for more information. Noted. 17. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering, Travis Herbner, therbner(@littlerock.gov or 501. 379.1805 for more information. Noted. 18. Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Traffic Engineering, Travis Herbner, therbner@littlerock.gov or 501. 379.1805 for more information. Noted. 19. Per the Master Street Plan, parking is restricted to one side of the street on a 24-foot wide street. Show on the plan now and on the final plat and bill of assurance, the area along the street where parking is allowed. Shown. 901 N 47th Street, Suite 200 Rogers, AR 72756 ' Crafton Tull m architecture I engineering I surveying 479.636.4838 (ph) 479.631.6224 (fax) 20. Street names and street naming conventions must be approved by Public Works. It is suggested that two (2) street names be used for the streets within the subdivision. Contact Glenn Haley, ghaley(a)Iittlerock.go_v_ or 501.371.4537. Noted. 21. Vegetation must be established on disturbed area within 21-days of completion of street construction activities. Understood. 22. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. Understood. 23. All public drainage easements must be unobstructed and access provided to the public right- of-way by constructed infrastructure and/or documented on the final plat. The plat should show the detention pond in tract land extending to the public right-of-way. Other drainage improvements may be best maintained and unobstructed if placed in similar tract lands. Shown as requested. 24. All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. Noted. 25. 100-year overflow swales must be constructed and placed within public drainage easements. Noted. Swales to be constructed. 26. Show proposed location(s) of USPS cluster box units in conformance with USPS and City of Little Rock policy design standards. Shown. 27. No access will be allowed from the rear of the lots to the adjacent street. Plat a no vehicle access easement a minimum of 10-feet in width. Easement shown. 28. In accordance with Section 32-8, no obstruction to visibility shall be located within a triangular area 50-feet back from the intersecting right-of-way line (or intersecting tangent lines for radial dedications) at the proposed intersection. Sight triangles shown. Utilities/Fire Department/Parks/County Planning: Little Rock Water Reclamation Authority: Sewer main extension required with easements if sewer service is required for this project. Contact Little Rock Water Reclamation Authority for additional information Understood Entergy: Entergy does not object to this proposal. There is an existing three phase, overhead power line on the north side of Lanehart Road on the south side of this development. Construction of any structure must maintain clearances between the structure and the power lines according to OSHA and NESC (code) requirements. All required separations and clearances to power lines must be maintained during and after construction. It is difficult to determine from the plat what that separation will be. Contact Entergy in advance to discuss electrical service requirements or adjustments to existing facilities (if any) as this project proceeds. Understood. Entergy will be contacted. Centerpoint Energy: No comment received. 901 N 47th Street, Suite 200 Rogers, AR 72756 ti Grafton Tull architecture I engineering I surveying AT & T: No comment received. Central Arkansas Water: No comment received. Fire Department, 479.636.4838 (ph) 479.631.6224 (fax) 1. Full Plan Review — Maintain Access Noted. 2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Noted. 3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Noted. 4. Loadinq. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Noted. 5. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Noted. 6. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 901 N 47th Street, Suite 200 Rogers, AR 72756 Crofton Tull architecture I engineering I surveying 479.636.4838 (ph) 479.631.6224 (fax) 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Understood. 7. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Understood. a. Exceptions: Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. b. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. 8. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants as per Table C105.1. Noted. Parks and Recreation: No comment received. County Planning: No comment. Building Codes/Landscape: BuildingCode: As per 2012 Arkansas Fire Prevention Code Volume III Residential Construction, Section R302.1(1) Table, Houses 5-feet apart must have one (1) hour fire walls on each exterior wall and no openings are allowed in that wall for doors or windows. Noted. 901 N 47th Street, Suite 200 Rogers, AR 72756 Craftan Tu I f architecture I engineering I surveying 479.636.4838 (ph) 479.631.6224 (tax) The 2012 AR Fire Prevention Code Vol. III for one (1) and two (2) family dwellings requires foundations meet the following Sections of the Code. If the foundation cannot be verified by the building official at the time of the footing inspection the building official may require verification the foundation meets the required elevation by a licensed engineer. Noted. R403.1.7.3 Foundation elevation. On grade sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12-inches (305 mm) plus two (2) percent. Noted. R403.1.7.4 Alternate setback and clearances. Alternate setbacks and clearances are permitted, subject to the approval of the building official. The building official is permitted to require an investigation and recommendation of a qualified engineer to demonstrate that the intent of this Section has been satisfied. Such an investigation shall include consideration of materials, height of slope, slope gradient, load intensity and erosion characteristics of slope material. Noted. Landscape: No comment. Tra nsr)ortation/Pllann incy Rock Region Metro: The site is not located on a dedicated Rock Region Metro Route. Planning Division: No comment. Should you have any additional questions, please feel free to contact us. Sincerely, 11 ITEM NO.: 4. NAME: Lanehart McPherson Preliminary Plat S-1828 LOCATION: located on the Northeast corner of Lanehart Road and McPherson Road Planning Staff Comments: 1. Provide notification of the abutting property owners including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than October 16, 2018. The Office of Planning and Development must receive the proof of notice no later than October 26, 2018. 2. Correct the zoning classification labels. The abutting zoning classifications should be R-2, Single-family. The property at the southeast corner of the site owned by Christopher Homes of Little Rock is zoned PD-R. 3. There are additional variances for lot widths require. Corner lots should be 75-feet in width. It appears Lots 26 and 27 are less than 60-feet at the building line. 4. Provide a no right of vehicular access easement along the street frontages. The easement should be 10-feet in width. 5. Provide the proposed phasing plan for the proposed plat area. Will the lots be developed in a single or multiple phase? If multiple phases include a note in the general notes section of the proposed preliminary plat indicating the phasing plan. 6. Provide the location of the proposed USPS mail kiosk. 7. The platted building lines on all corner lots should be 25-feet. 8. Remove the platted side and rear yard platted building lines. 9. Six (6) foot fences are not allowed in the setback adjacent to the streets. Variance/Waivers: 1. A variance from the Land Alteration Ordinance to allow grading of the lots with the installation of the basic infrastructure. 2. A variance from 36-254 to allow lot widths, interior lot widths and corner lots, less than the typical ordinance standard. Also to allow platted building lines less than the typical ordinance standard. Engineering Comments: Public Works Conditions: 1. McPherson Road is classified on the Master Street Plan as a residential street. A dedication of right-of-way 25-feet from centerline will be required. 2. Lanehart Road is classified on the Master Street Plan as a collector street. A dedication of right-of-way 30-feet from centerline will be required. 3. The west end of "Street 1" to McPherson Road is not classified as a loop street and should be constructed to a residential standard street section with a minimum of 26-feet of pavement within a 50-foot right-of-way. ITEM NO 4. S-1828 4. "Street 5" is not classified as a loop street or cul-de-sac and should be constructed to a residential standard street section of minimum 26-feet within a 50-foot right-of-way. 5. Sidewalks with appropriate handicap ramps are required to be installed on the west end of "Street 1" and along "Street 5" in accordance with Section 31-175 of the Little Rock Code of Ordinances and the Master Street Plan. 6. A 20-foot radial dedication of right-of-way is required at the intersection of Lanehart Road and McPherson Road. A 20-foot radial right-of-way dedication is required at all proposed street intersections. 7. With site development, provide the design of street conforming to the Master Street Plan. Construct one-half street improvement to Lanehart Road including 5-foot sidewalks with the planned development. The new back of curb should be placed 18-feet from center of the existing street. 8. Repair or replace any curb, gutter, sidewalk and access ramps that are damaged and not in compliance with ADA recommendations in the public right-of-way prior to occupancy. 9. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is a variance being requested to advance graded future phases with the first phase? Is a variance being requested to grade the lots with the street construction? 10. Provide a Sketch Grading and Drainage Plan with proposed pipe and ditch locations per Section 29-186. 11. Stormwater detention ordinance applies to this property. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owners association and detailed in the bill of assurance. 12.Access to detention ponds must be provided to the public right-of-way and/or access easement for future maintenance by the developer and/or local property owners association. 13. Per Section 29-102 an evaluation should be conducted on the basis of existing downstream development and any analysis of stormwater runoff with and without the proposed development. If the proposed development will cause or increase downstream flooding conditions, provisions to minimize such flooding conditions should be included in the design of the storm management improvements. Such provisions may include downstream improvements and/or detention of stormwater runoff and it regulated discharge to the downstream storm drainage system. 14.If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. 15. Street improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 16.Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons, gsimmonsplittlerock.gov or 501.379.1813 for more information. 17.Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering, Travis Herbner, therbnerglittlerock.gov or 501. 379.1805 for more information. 18. Hauling of fill material on or off site over municipal streets and roads requires approval ITEM NO.: 4. S-1828 prior to a grading permit being issued. Contact Traffic Engineering, Travis Herbner, therbner(cD-littlerock.gov or 501. 379.1805 for more information. 19. Per the Master Street Plan, parking is restricted to one side of the street on a 24-foot wide street. Show on the plan now and on the final plat and bill of assurance, the area along the street where parking is allowed. 20. Street names and street naming conventions must be approved by Public Works. It is suggested that two (2) street names be used for the streets within the subdivision. Contact Glenn Haley, ghale-ljttlerock.gov or 501.371.4537. 21.Vegetation must be established on disturbed area within 21-days of completion of street construction activities. 22. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 23.All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. The plat should show the detention pond in tract land extending to the public right-of-way. Other drainage improvements may be best maintained and unobstructed if placed in similar tract lands. 24.All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. 25.100-year overflow swales must be constructed and placed within public drainage easements. 26. Show proposed location(s) of USPS cluster box units in conformance with USPS and City of Little Rock policy design standards. 27. No access will be allowed from the rear of the lots to the adjacent street. Plat a no vehicle access easement a minimum of 10-feet in width. 28.In accordance with Section 32-8, no obstruction to visibility shall be located within a triangular area 50-feet back from the intersecting right-of-way line (or intersecting tangent lines for radial dedications) at the proposed intersection. Utilities/Fire Department/Parks/County Plannin Little Rock Water Reclamation Authority: Sewer main extension required with easements if sewer service is required for this project. Contact Little Rock Water Reclamation Authority for additional information Entergy: Entergy does not object to this proposal. There is an existing three phase, overhead power line on the north side of Lanehart Road on the south side of this development. Construction of any structure must maintain clearances between the structure and the power lines according to OSHA and NESC (code) requirements. All required separations and clearances to power lines must be maintained during and after construction. It is difficult to determine from the plat what that separation will be. Contact Entergy in advance to discuss electrical service requirements or adjustments to existing facilities (if any) as this project proceeds. Center pint Ener : No comment received. ITEM NO.: 4 S-1828 AT & T: No comment received. Central Arkansas Water: No comment received. Fire Department: 1. Full Plan Review — Maintain Access 2, Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. 3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. 4. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. 5. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead- end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. 6. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. ITEM NO.: 4. S-1828 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. 7. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. a. Exceptions: Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. b. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. 8. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Planning: No comment. Building Codes/Landscape: Building Code: As per 2012 Arkansas Fire Prevention Code Volume III Residential Construction, Section R302.1(1) Table, Houses 5-feet apart must have one (1) hour fire walls on each exterior wall and no openings are allowed in that wall for doors or windows. The 2012 AR Fire Prevention Code Vol. III for one (1) and two (2) family dwellings requires foundations meet the following Sections of the Code. If the foundation cannot be verified by the building official at the time of the footing inspection the building official may require verification the foundation meets the required elevation by a licensed engineer. R403.1.7.3 Foundation elevation. On grade sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12-inches (305 mm) plus two (2) percent. ITEM NO.: 4. S-1828 R403.1.7.4 Alternate setback and clearances. Alternate setbacks and clearances are permitted, subject to the approval of the building official. The building official is permitted to require an investigation and recommendation of a qualified engineer to demonstrate that the intent of this Section has been satisfied. Such an investigation shall include consideration of materials, height of slope, slope gradient, load intensity and erosion characteristics of slope material. Landscape: No comment. Trans ortation/Plannin Rock Region Metro: The site is not located on a dedicated Rock Region Metro Route. Planning Division: No comment. Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on or before Wednesday, October 17, 2018. If you have any questions please contact Dana Carney, dcarney@1ittlerock.gov or 501.371.6817 or Jamie Collins, gcollinsglittlerock goy or 501.371.6818. STAFF UPDATE AND RECOMMENDATION: The applicant has submitted revisions and responses to address the outstanding staff issues. Staff recommends approval of the proposed preliminary plat subject to compliance with the following conditions: Compliance with the staff comments and conditions outlined in paragraphs D, E and F of the agenda staff report. Compliance with the following additional conditions from Public Works: a. The proposed sketch grading and drainage plan is approved conceptually and more definite plans and calculations will be provided with the construction plans prior to installation of any stormwater drainage infrastructure. b. Vehicle parking will be restricted from the interior side of the center block; this note must be placed on the plat. c. An access ramp is proposed by the applicant to be constructed on the west side of McPherson Road at the McPherson Road/Street 1 intersection. d. A franchise permit is required to be obtained for the LISPS box units to be placed in the public right-of-way. Plans for the USPS box units must be approved by staff prior to installation. Staff recommends approval of the following variances for this plat: 1. A variance from Section 31-232 (e) to allow proposed lot Ito have a width less than 75 feet. 2. A variance from Section 31-256 to allow Lot Ito have a street side building line of less than 25 feet on the McPherson road perimeter. 3. A variance from Section 36-254 to allow lots 1-13, 18-20, 23, 24, 26, 27, 34, 36, 41 and 43 to have a width of less than 60 feet. 4. A variance from the land alteration ordinance to allow advance grading of the lots with construction of the street and drainage infrastructure. Carney, Dana From: Carney, Dana Sent: Tuesday, October 23, 2018 10:38 AM To: Floriani, Vince; 'Brad Peterson' Subject: RE: Lanehart McPherson Subdivision - Drainage Report Thank you. The agenda was completed and will go out with "staff recommendation forthcoming". I will read the information below into the record at the meeting. At this point, it looks like it will be on regular agenda due to opposition From: Floriani, Vince Sent: Tuesday, October 23, 2018 10:05 AM To: Carney, Dana <DCarney@littlerock.gov>;'Brad Peterson' <Brad.Peterson @craftontuILcom> Subject: RE: Lanehart McPherson Subdivision - Drainage Report Dana, Public Works recommends approval of the preliminary plat with the following conditions: 1. The proposed sketch grading and drainage plan is approved conceptually and more definite plans and calculations will be provided with the construction plans prior to installation of any stormwater drainage infrastructure; 2. Vehicle parking will be restricted from the interior side of the center block; 3. An access ramp is proposed by the applicant to be constructed on the west side of McPherson Road at the McPherson Rd/Street 1 intersection; 4. A franchise permit is required to be obtained for the USPS box units to be placed within the public right-of- way. Plans for the USPS box units must be provided staff prior to installation. In addition, staff recommends approval of a land alteration variance to advance grade the lots with construction of the street and drainage infrastructure. If you have any questions, please let me know. Thanks, Vince Floriani, P.E. Little Rock Public Works -Civil Engineering 701 W. Markham St. Little Rock, Arkansas 72201 501-371-4817 From: Carney, Dana Sent: Tuesday, October 23, 2018 9:33 AM To: 'Brad Peterson'; Floriani, Vince Subject: RE: Lanehart McPherson Subdivision - Drainage Report Vince please let me know your thoughts. Brad is the attached a revised plan? There is no revision date on it Dana Carney, Zoning and Subdivision Manager Department of Planning and Development 723 W. Markham Street Little Rock, AR 72201 (501) 371-6817 From: Brad Peterson [mailto:Brad.Peterson@craf#ontuil.com] Sent: Tuesday, October 23, 2018 9:21 AM To: Floriani, Vince <VFloriani@littlerock.Pov> Cc: Carney, Dana <DCarney _ littlerock.gov> Subject: RE: Lanehart McPherson Subdivision - Drainage Report Vince, Our response to your most recent comments are as follows: 3. Will comply. A sidewalk and access ramp will be constructed to existing sidewalk on the west side of McPherson St. 4. Street 5 dimension labels have been corrected. 9. A variance is requested to grade the lots with the construction of street and drainage infrastructure. 10. Grading and storm drainage has been revised as shown on the attached revised preliminary plat. 12. Storm drainage will be piped to the detention pond to allow access for routine maintenance. Applicant will work with staff to determine appropriate placement of the inlet and pipe to avoid damage to infrastructure during maintenance activities. 19. Vehicle parking will be restricted to the interior loop portion of streets 1, 2, 3, and 4 Thanks, Brad Brad Peterson, P.E., CFM, LEED AP Vice President I Infrastructure rtfton TUil • a Office: 501-664-3245 1 Direct: 501-748-8246 1 Fax: 501-664-6704 10825 Financial Centre Parkway, Ste 300 Little Rock, AR 72211-3554 www.craftontull.com Disclaimer This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you are not the named addressee you should not disseminate, distribute or copy this a -mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. Thank you, we appreciate your cooperation. From: Floriani, Vince <VFloriani littlerock. ov> Sent: Thursday, October 18, 2018 2:05 PM To: Brad Peterson <Brad.Peterson@craftontu_Ilcom> Cc: Carney, Dana <DCa rneV@ little rock. ov> Subject: RE: Lanehart McPherson Subdivision - Drainage Report Brad, Following review of your revised plans I have some comments and questions. 3. With the new proposed intersection at McPherson St. and Street 1 constructed with sidewalk and access ramp, staff requests an access ramp to be constructed on the west side of McPherson St. to align with the new sidewalk and ramp to improve pedestrian access. 4. Street 5 is not shown to be constructed in conformance to the Master Street Plan residential street standard. Is the applicant requesting a variance to not construct to the residential street standard? 9. Please confirm the applicant requesting an advanced grading variance to grade the lots with construction of the street and drainage infrastructure. 10. Staff cannot approve the proposed sketch drainage plan. At the Planning Commission, drainage improvements are only approved fundamentally and conceptually. Fundamentally, your plan proposes to pond stormwater within the street gutter on the interior block of the street at the northeast corner of the subdivision or the plan proposes to not construct a street crown. Neither of these options can be approved by staff. In addition, staff cannot approve a inlet with throat extensions that exceed 10 ft. You are proposing 20 ft of throat extension. Per the drainage manual, during the 25 year and larger storm events, the center 10 ft of a residential street cannot flood and must be passable. It appears additional drainage infrastructure should be installed. Please revise with sketch plan to resolve these issues. 12. Access to the detention pond for routine maintenance as required by the stormwater drainage manual will be blocked or infrastructure damaged due to the proposed minimum width of the open tract, the proposed street inlet adjacent to the tract, and the depth and width of the proposed ditching. 8 to 10 additional feet of width on one side of the ditch and inlet should be provided in the open tract. 19. Please confirm that vehicle parking will be restricted from the interior loop portion of the streets 1, 2, 3, and 4. If you have any questions or desire additional information, please do not hesitate to contact me. Thanks, Vince Floriani, P.E. Little Rock Public Works -Civil Engineering 701 W. Markham St. Little Rock, Arkansas 72201 501-371-4817 From: Brad Peterson[ma ilto: Brad. Peterson(acraftontull.com] Sent: Thursday, October 18, 2018 8:57 AM To: Floriani, Vince Cc: Carney, Dana Subject: RE: Lanehart McPherson Subdivision - Drainage Report Vince, Attached is an updated drainage report and a grading plan for the Lanehart McPherson Subdivision. The attached plat documents were delivered to Dana yesterday afternoon. Let us know if you need hard copies of these documents or anything else. Thanks, Brad Brad Peterson, P.E., CFM, LEED AP Vice President I Infrastructure Grafton Tull Office: 501-664-3245 1 Direct: 501-748-8246 1 Fax: 501-664-6704 10825 Financial Centre Parkway, Ste 300 Little Rock, AR 72211-3554 www.craftontull.com f TWTI Disclaimer This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. Thank you, we appreciate your cooperation. From: Brad Peterson Sent: Wednesday, October 3, 2018 11:31 AM To: Floriani, Vince <VFloriani@littlerock.gQv> Cc:'James, Donna' <DJames@littlerock.gov> Subject: Lanehart McPherson Subdivision - Drainage Report Vince, Attached is the drainage report of the McPherson Subdivision that's going through the Planning Commission. We'll be at subdivision next Wednesday. Thanks, Brad Carney, Dana From: Floriani, Vince Sent: Monday, October 22, 2018 12:34 PM To: Carney, Dana Subject: RE: Lanehart McPherson Plat The applicant is continuing to work with staff on issues in regards to the proposed stormwater drainage plan and access to the detention pond for maintenance. An update is forthcoming. Vince Floriani, P.E. Little Rock Public Works -Civil Engineering 701 W. Markham St. Little Rock, Arkansas 72201 501-371-4817 From: Carney, Dana Sent: Monday, October 22, 2018 8:55 AM To: Floriani, Vince Subject: RE: Lanehart McPherson Plat Can you send me a sentence or two about the outstanding items. I will put those in my write-up so I can get it done. I will then leave it as staff recommendation forthcoming. From: Floriani, Vince Sent: Monday, October 22, 2018 8:33 AM To: Carney, Dana <DCarnev@littleroc_k. oy>;'Brad.Peterson@craftontuIl.com' <Brad.Peterson@craftantull.com> Subject: RE: Lanehart McPherson Plat Dana, Yes, there are still outstanding items that need to be resolved before Public Works can recommend approval. I believe Brad is working on them. I do not know a timeframe for completion. Vince Floriani, P.E. Little Rock Public Works -Civil Engineering 701 W. Markham St. Little Rock, Arkansas 72201 501-371-4817 From: Carney, Dana Sent: Monday, October 22, 2018 7:21 AM To: Floriani, Vince Subject: Lanehart McPherson Plat Vince Where are we on this plat? There were outstanding engineering issues as I recall. Dana Carney, Dana From: Brad Peterson <Brad.Peterson @craftontuILcom> Sent: Thursday, October 18, 2018 2:19 PM To: Floriani, Vince Cc: Carney, Dana Subject: RE: Lanehart McPherson Subdivision - Drainage Report Vince, We'll review your comments and provide responses with updated drawings as quickly as possible. It looks like Street 5 was drawn to be standard residential street, but the dimensions were not updated. We'll address this in our response. We won't be requesting a variance to not construct to the residential street standard. Thanks, Brad Brad Peterson, P.E., CFM, LEED AP Vice President I Infrastructure }' Grafton Tull Office: 501-664-3245 1 Direct: 501-748-8246 1 Fax: 501-664-6704 10825 Financial Centre Parkway, Ste 300 Little Rock, AR 72211-3554 www.craftontull.com Disclaimer This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. Thank you, we appreciate your cooperation. From: Floriani, Vince <VFloriani@littlerock.gov> Sent: Thursday, October 18, 2018 2:05 PM To: Brad Peterson <Brad.Peterson@craftontull.com> Cc: Carney, Dana <DCarney@little rock.gov> Subject: RE: Lanehart McPherson Subdivision - Drainage Report Brad, Following review of your revised plans I have some comments and questions. 3. With the new proposed intersection at McPherson St. and Street 1 constructed with sidewalk and access ramp, staff requests an access ramp to be constructed on the west side of McPherson St. to align with the new sidewalk and ramp to improve pedestrian access. 4. Street 5 is not shown to be constructed in conformance to the Master Street Plan residential street standard. Is the applicant requesting a variance to not construct to the residential street standard? 9. Please confirm the applicant requesting an advanced grading variance to grade the lots with construction of the street and drainage infrastructure. 10. Staff cannot approve the proposed sketch drainage plan. At the Planning Commission, drainage improvements are only approved fundamentally and conceptually. Fundamentally, your plan proposes to pond stormwater within the street gutter on the interior block of the street at the northeast corner of the subdivision or the plan proposes to not construct a street crown. Neither of these options can be approved by staff. In addition, staff cannot approve a inlet with throat extensions that exceed 10 ft. You are proposing 20 ft of throat extension. Per the drainage manual, during the 25 year and larger storm events, the center 10 ft of a residential street cannot flood and must be passable. It appears additional drainage infrastructure should be installed. Please revise with sketch plan to resolve these issues. 12. Access to the detention pond for routine maintenance as required by the stormwater drainage manual will be blocked or infrastructure damaged due to the proposed minimum width of the open tract, the proposed street inlet adjacent to the tract, and the depth and width of the proposed ditching. 8 to 10 additional feet of width on one side of the ditch and inlet should be provided in the open tract. 19. Please confirm that vehicle parking will be restricted from the interior loop portion of the streets 1, 2, 3, and 4. If you have any questions or desire additional information, please do not hesitate to contact me. Thanks, Vince Floriani, P.E. Little Rock Public Works -Civil Engineering 701 W. Markham St. Little Rock, Arkansas 72201 501-371-4817 From: Brad Peterson[mailto:Brad.Peterson@craftontull.com] Sent: Thursday, October 18, 2018 8:57 AM To: Floriani, Vince Cc: Carney, Dana Subject: RE: Lanehart McPherson Subdivision - Drainage Report Vince, Attached is an updated drainage report and a grading plan for the Lanehart McPherson Subdivision. The attached plat documents were delivered to Dana yesterday afternoon. Let us know if you need hard copies of these documents or anything else. Thanks, Brad November 1, 2018 ITEM NO.: 4 NAME: Lanehart McPherson Preliminary Plat FILE NO.: S-1828 LOCATION: Located on the Northeast corner of Lanehart Road and McPherson Road DEVELOPER: Little Rock LD, LLC 4058 N College Street, Suite 300 Fayetteville, AR 72703 OWNER/AUTHORIZED AGENT: Roman Catholic Diocese of Little Rock, Owner Little Rock LD, LLC — Purchase Agreement Crafton Tull and Associates, Agent SURVEYOR/ENGINEER: Crafton Tull and Associates 901 N 47th Street #200 Rogers, AR 72756 AREA: 12.03-acres NUMBER OF LOTS: 45 FT. NEW STREET: 1,812 LF WARD: 7 PLANNING DISTRICT: 12 — 65th Street West CENSUS TRACT: 24.05 CURRENT ZONING: VARIANCE/WAIVERS: R-2, Single-family 1. A variance from the Land Alteration Ordinance to allow grading of the lots with the installation of the basic infrastructure. 2. A variance from 36-254 to allow lot widths, interior lot widths and corner lots, less than the typical ordinance standard. Also to allow platted building lines less than the typical ordinance standard. November 1, 2018 SUBDIVISION ITEM NO.: 4(Cont.)FILE NO.: S-1828 A. PROPOSAUREQUEST/APPLICANT'S STATEMENT: The request is to subdivide 12.03-acres into 45 single-family residential lots. According to the applicant the parcel is small, so a simple loop street is being proposed with access to each of the existing roadways; Lanehart and McPherson Roads. Due to the small size of the property the applicant is requesting two (2) points of access. An existing overhead power line easement along Lanehart Road, and the need for a substantially wide drainage easement, the lots have been configured to include a few 55-foot wide lots. All the 55-foot wide lots meet the minimum lot area size of the R-2, Single-family Zoning District. The lots have an average depth of 135-feet. The plat also includes a variance to allow the corner lots with a lot width less than 75-feet. Lots in the subdivision will vary in size from 7,000 square feet to over 18,000 square feet. B. EXISTING CONDITIONS: The property is located on the Northeast corner of Lanehart and McPherson Roads. The site is timbered. There is a senior living facility located to the east of this site. To the west is a single-family subdivision and south of the site are single-family homes located on large lots or tracts. C. NEIGHBORHOOD COMMENTS: All abutting property owners along with the Stagecoach Dodd Neighborhood Association and Southwest Little Rock United for Progress were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. McPherson Road is classified on the Master Street Plan as a residential street. A dedication of right-of-way 25-feet from centerline will be required. 2. Lanehart Road is classified on the Master Street Plan as a collector street. A dedication of right-of-way 30-feet from centerline will be required. 3. The west end of "Street 1" to McPherson Road is not classified as a loop street and should be constructed to a residential standard street section with a minimum of 26-feet of pavement within a 50-foot right-of-way. 4. "Street 5" is not classified as a loop street or cul-de-sac and should be constructed to a residential standard street section of minimum 26-feet within a 50-foot right-of-way. 2 November 1, 2018 SUBDIVISION ITEM NO.: 4 (Cont.) FILE NO.: S-1828 5. Sidewalks with appropriate handicap ramps are required to be installed on the west end of "Street 1" and along "Street 5" in accordance with Section 31-175 of the Little Rock Code of Ordinances and the Master Street Plan. 6. A 20-foot radial dedication of right-of-way is required at the intersection of Lanehart Road and McPherson Road. A 20-foot radial right-of-way dedication is required at all proposed street intersections. 7. With site development, provide the design of street conforming to the Master Street Plan. Construct one-half street improvement to Lanehart Road including 5-foot sidewalks with the planned development. The new back of curb should be placed 18-feet from center of the existing street. 8. Repair or replace any curb, gutter, sidewalk and access ramps that are damaged and not in compliance with ADA recommendations in the public right-of-way prior to occupancy. 9. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is a variance being requested to advance graded future phases with the first phase? Is a variance being requested to grade the lots with the street construction? 10. Provide a Sketch Grading and Drainage Plan with proposed pipe and ditch locations per Section 29-186. 11. Stormwater detention ordinance applies to this property. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owners association and detailed in the bill of assurance. 12. Access to detention ponds must be provided to the public right-of-way and/or access easement for future maintenance by the developer and/or local property owners association. 13. Per Section 29-102 an evaluation should be conducted on the basis of existing downstream development and any analysis of stormwater runoff with and without the proposed development. If the proposed development will cause or increase downstream flooding conditions, provisions to minimize such flooding conditions should be included in the design of the storm management improvements. Such provisions may include downstream improvements and/or detention of stormwater runoff and it regulated discharge to the downstream storm drainage system. 14. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. 3 November 1, 2018 SUBDIVISION ITEM NO.: 4 [Cont. FILE NO.: S-1828 15. Street improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 16. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons, simmons littierock. ov or 501.379.1813 for more information. 17. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering, Travis Herbner, therbner@littlerock.gov or 501. 379.1805 for more information. 18. Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Traffic Engineering, Travis Herbner, therbner -_littlerock.gov or 501. 379.1805 for more information. 19. Per the Master Street Plan, parking is restricted to one side of the street on a 24-foot wide street. Show on the plan now and on the final plat and bill of assurance, the area along the street where parking is allowed. 20. Street names and street naming conventions must be approved by Public Works. It is suggested that two (2) street names be used for the streets within the subdivision. Contact Glenn Haley, ghaleyCcr—littlerock.gov or 501.371.4537. 21. Vegetation must be established on disturbed area within 21-days of completion of street construction activities. 22. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 23. All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. The plat should show the detention pond in tract land extending to the public right-of-way. Other drainage improvements may be best maintained and unobstructed if placed in similar tract lands. 24. All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. 25. 100-year overflow swales must be constructed and placed within public drainage easements. 26. Show proposed location(s) of USPS cluster box units in conformance with USPS and City of Little Rock policy design standards. 4 November 1, 2018 .qI IRniviRinN NO.: 4 (Cont. FILE NO.: S-1828 27. No access will be allowed from the rear of the lots to the adjacent street. Plat a no vehicle access easement a minimum of 10-feet in width. 28. In accordance with Section 32-8, no obstruction to visibility shall be located within a triangular area 50-feet back from the intersecting right-of-way line (or intersecting tangent lines for radial dedications) at the proposed intersection. E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING: Little Rock Water Reclamation Authority : Sewer main extension required with easements if sewer service is required for this project. Contact Little Rock Water Reclamation Authority for additional information Entergy: Entergy does not object to this proposal. There is an existing three phase, overhead power line on the north side of Lanehart Road on the south side of this development. Construction of any structure must maintain clearances between the structure and the power lines according to OSHA and NESC (code) requirements. All required separations and clearances to power lines must be maintained during and after construction. It is difficult to determine from the plat what that separation will be. Contact Entergy in advance to discuss electrical service requirements or adjustments to existing facilities (if any) as this project proceeds. Centerpoint Energy: No comment received. AT & T: No comment received. Central Arkansas Water: No comment received. Fire Department: 1. Full Plan Review — Maintain Access 2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. 3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. 4. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and Ili November 1, 2018 SUBDIVISION ITEM NO.: 4 (Cont. FILE NO.: S-1828 loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. 5. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. 6. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 10. Minimum gate width shall be 20 feet. 11. Gates shall be of swinging or sliding type. 12. Construction of gates shall be of material that allow manual operation by one person. 13. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 14. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 15. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 16. Locking device specifications shall be submitted for approval \by the fire code official 17. Electric gate operators, where provided, shall be listed in accordance with UL 325. a. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. 7. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with 1.1 November 1, 2018 SUBDIVISION ITEM NO.: 4 (Cont. FILE NO.: S-1828 two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. 8. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Planning: No comment. F. BUILDING CODES/LANDSCAPE: Building Code: As per 2012 Arkansas Fire Prevention Code Volume III Residential Construction, Section R302.1(1) Table, Houses 5-feet apart must have one (1) hour fire walls on each exterior wall and no openings are allowed in that wall for doors or windows. The 2012 AR Fire Prevention Code Vol. III for one (1) and two (2) family dwellings requires foundations meet the following Sections of the Code. If the foundation cannot be verified by the building official at the time of the footing inspection the building official may require verification the foundation meets the required elevation by a licensed engineer. R403.1.7.3 Foundation elevation. On grade sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12-inches (305 mm) plus two (2) percent. R403.1.7.4 Alternate setback and clearances. Alternate setbacks and clearances are permitted, subject to the approval of the building official. The building official is permitted to require an investigation and recommendation of a qualified engineer to demonstrate that the intent of this Section has been satisfied. Such an 7 November 1, 2018 SUBDIVISION ITEM NO.: 4 Cont.) FILE NO.: S-1828 G. H investigation shall include consideration of materials, height of slope, slope gradient, load intensity and erosion characteristics of slope material. Landscape: No comment. TRANSPORTATION/PLANNING: Rock Region Metro: The site is not located on a dedicated Rock Region Metro Route. Planning Division: No comment. SUBDIVISION COMMITTEE COMMENT: (October 10, 2018) Mr. Brad Peterson of Crafton, Tull and Associates was present representing the request. Staff presented an overview of the item stating there were a few outstanding technical issues in need of addressing related to the proposed preliminary plat. Staff stated corner lots should be indicated with a minimum lot width of 75-feet and a minimum building setback along each street side of 25-feet. Mr. Peterson questioned if the corner lots could be indicated with a lesser width and approved as a variance. Staff stated the request could include a variance to allow the reduced lot width for the corner lots. Staff requested Mr. Peterson remove the building lines indicated along the rear and side yards. Staff requested he label the front building setback. Staff requested Mr. Peterson correct the zoning classifications labeled on the plat. Public Works comments were addressed. Staff stated a grading permit was required prior to any land clearing on the site. Staff stated parking would be restricted to one (1) side of the street on the streets proposed with 24-feet of pavement. Staff stated the entrance streets did not meet the minimum requirements for a minor residential street. Staff stated sidewalks should be provided from Lanehart and McPherson Roads into the subdivision to allow for proper pedestrian access. Staff requested the applicant provide the location for the USPS Mail Cluster Box(s). Staff stated fences would not be allowed within the building setback or at a minimum fences were to be placed to allow for a proper sight distance with the intersecting street. Staff noted the comments from the various other departments and agencies. Staff suggested the applicant contact the departments or agencies directly with any questions or concerns. There were no more issues for discussion. The Committee then forwarded the item to the full Commission for final action. 0 November 1, 2018 SUBDIVISION ITEM NO.: 4 (Cont.) FILE NO.- S-1828 J ANALYSIS: The request is to subdivide a 12.03 acre tract into 45 single family residential lots and 1 tract which will contain the stormwater detention facility. Access to the proposed subdivision is from 2 new streets off of Lanehart Road and McPherson Road. The proposed density is 3.74 +/- lots per acre. The minimum lot size is 7,000 square feet. The lots range in size from 7,000 square feet to over 16,000 square feet. The overall average lot size is 8,606 square feet. The applicant submitted a revised plat and cover letter addressing most of the technical issues raised at subdivision committee. The zoning designations of the abutting properties have been corrected. A 10-foot "no vehicle access easement" has been located along the rear of the lots that are adjacent to both McPherson and Lanehart Roads. The subdivision is proposed to be developed in a single phase. USPS mail kiosks have been located on each of the two entry streets. The platted building lines on all corner lots have been indicated at 25 feet, as required. The required right-of-way dedication for McPherson, Lanehart and the radial at the intersection has been shown. The applicant has agreed to make the changes to the required right-of-way and street design for the two entry streets to comply with residential standard street sections. Three variances are requested with the proposed plat. Lot 1, located at the corner of Street 1 and McPherson is indicated as 65.02 feet in width. Section 31-232 (e) states corner lots are to have a minimum width of 75 feet to accommodate the required building line on both streets. That same Lot 1 is proposed to have a building line of 16 feet on the McPherson perimeter. Section 31-256 states the building lines for residential lots are to be at least 25 feet from each street property line. Section 36-254 states the minimum lot width in the R-2 zoning district is to be 60 feet. A total of 24 of the 45 lots are proposed to have a width of 55 feet. The affected lots are 1-13, 18-20, 23, 24, 26, 27, 34, 36, 41 and 43. All of the lots exceed the R-2 zoning minimum of 7,000 square feet in size. The applicant is also requesting a variance from the Land Alteration Ordinance to allow grading of the lots with the installation of the basic infrastructure since the subdivision is to be developed in one phase. The applicant is continuing to work with staff on issues regarding the proposed stormwater drainage plan and access to the proposed detention pond for maintenance STAFF RECOMMENDATION: Staff recommendation is forthcoming. E01 November 1, 2018 SUBDIVISION ITEM NO.: 4 Cont. FILE NO.: S-1828 PLANNING COMMISSION ACTION: (NOVEMBER 1, 2018) The applicant was present. There were no objectors present. Staff informed the commission that the applicant had submitted revisions and responses to address the outstanding staff issues. Staff recommended approval of the proposed preliminary plat subject to compliance with the following conditions: 1. Compliance with the staff comments and conditions outlined in paragraphs D, E and F of the agenda staff report. 2. Compliance with the following additional conditions from Public Works: a. The proposed sketch grading and drainage plan is approved conceptually and more definite plans and calculations will be provided with the construction plans prior to installation of any stormwater drainage infrastructure. b. Vehicle parking will be restricted from the interior side of the center block; this note must be placed on the plat. c. An access ramp is proposed by the applicant to be constructed on the west side of McPherson Road at the McPherson Road/Street 1 intersection. d. A franchise permit is required to be obtained for the USPS box units to be placed in the public right-of-way. Plans for the USPS box units must be approved by staff prior to installation. Staff recommended approval of the following variances for this preliminary plat: 1. A variance from Section 31-232 (e) to allow Lot 1 to have a lot width less than 75 feet. 2. A variance from Section 31-256 to allow Lot 1 to have a street side building line of less than 25 feet on the McPherson Road perimeter. 3. A variance from Section 36-254 to allow Lots 1-13, 18-20, 23, 24, 26, 27, 34, 36, 41 and 43 to have a width less than 60 feet. 4. A variance from the land alteration ordinance to allow advance grading of the lots with construction of the street and drainage infrastructure. There was no further discussion. The item was placed on the consent agenda and approved as recommended by staff, including all conditions and variances. The vote was 11 ayes, 0 noes and 0 absent. 10