HomeMy WebLinkAboutS-1812 Staff AnalysisMay 17, 2018
ITEM NO.: 2
NAME: Rowanwood Subdivision Site Plan Review
FILE NO.: S-1812
LOCATION: Located on the East side of South Shackleford Road in the 2700 — 3300
Blocks
DEVELOPER:
Rowan Development LLC
12206 West Markham Street #110
Little Rock, AR 72221
OWNER/AUTHORIZED AGENT:
Rowan Development — Jacob Chi Owner
Holloway Engineering, Surveying and Civil Design, PLLC —Authorized Agent
SURVEYOR/ENGINEER.-
Holloway Engineering, Surveying and Civil Design, PLLC
200 Casey Drive
Maumelle, AR 72113
AREA: 21.97-acres NUMBER OF LOTS: 1
WARD: 6 PLANNING DISTRICT: 11 —1-430
CURRENT ZONING: MF-12
FT. NEW STREET: 762.66 LF
CENSUS TRACT: 24.08
VARIANCEIWAIVERS: A variance from the Land Alteration Ordinance to allow grading
of the entire development with the development of Phase I.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The request is for Subdivision/Multiple Building Site Plan Review as per Section
31-13 of the Little Rock Code of Ordinances. The property contains 21.97-acres
and is zoned MF-12. The applicant is proposing two, three and four unit single
story multi -family residential development on the east side of the creek. The
architecture of the units is intended to resemble high end single-family
residential. A total of 96-units are proposed within 30 buildings in the Phase I
portion of the development. No development plans are proposed for the Phase
11 portion of the development.
May 17, 2018
SUBDIVISION
ITEM NO.: 2 (Cont.) FILE NO.: S-1812
The units will be developed on a private gated street. No connection to
Aldersgate Road is proposed with the new development. The plan indicates an
emergency access drive extending from Aldersgate Road to Rowanwood Drive,
within the subdivision.
The applicant indicates the intent is to impact the existing creek as little as
possible but box culverts to tie in the existing drainage due to the required
widening on Shackleford Road will be required. The applicant indicates an
extensive amount of earth work will be required for the development. The
applicant is seeking approval of a variance request from the Land Alteration
Ordinance to allow grading of the entirety of the property with the development of
the first phase. The applicant notes there will be multiple segmental block walls
needed within the development.
No retaining wall is proposed to exceed the maximum wall height of 15-feet as
allowed per the Land Alteration Ordinance.
B. EXISTING CONDITIONS:
The property is heavily wooded. South Shackleford Road is located on the
western perimeter of the site and Good Shepard, a retirement community, is
located to the east. North of the site is Camp Aldersgate and south of the site is
a housing community operated by Our Way accessed from West 36t" Street.
Also south of the site located along South Shackleford Road is an undeveloped
wooded property zoned 0-3, General Office District. Street improvements to
South Shackleford Road adjacent to this site have not been completed. The
street improvements across South Shackleford Road were completed by the City
including curb, gutter and sidewalk.
C. NEIGHBORHOOD COMMENTS:
All property owners located within 200-feet of the site along with the John Barrow
Neighborhood Association and the Kensington Place Property Owners
Association were notified of the public hearing.
D. ENGINEERING COMMENTS:
BLIC WORKS CONDITIONS:
1. South Shackleford Road is classified on the Master Street Plan as a minor
arterial. A dedication of right-of-way 45-feet from centerline or back of the
new sidewalk will be required.
2. With site development, provide the design of street conforming to the
Master Street Plan. Construct one-half street improvement to South
K
May 17, 2018
SUBDIVISION
ITEM NO.: 2 (Cont.) FILE NO.: S-1812
Shackleford Road including 5-foot sidewalks with the planned development.
The new back of curb should be located 59-feet from west curb line.
Striping should be provided for a lane shift and left turn lane into site and
Shackleford Pass with tapers. Additional paving and striping beyond the
property line maybe needed for turn lane tapers to meet AASHTO and
MUTCD standards. Half street improvements should be made to South
Shackleford Road adjacent to the subject property. The existing culvert
under South Shackleford Road should be lengthened. Provide a revised
plan showing the existing and proposed street and drainage improvements,
driveways, intersecting streets, and striping.
3. Private access is proposed for these lots. In accordance with Section
31-207, private streets must be designed to the same standards as public
streets. A minimum access easement width of 45-feet is required and street
width of 24-feet from back of curb to back
4. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other
than residential subdivisions, site grading and drainage plans must be
submitted and approved prior to the start of construction. Is an advanced
grading permit being requested to grade and clear Phase 2 with the
issuance of a grading permit for Phase 1?
5. Provide a sketch grading and drainage plan showing the centerline of the
creek, label elevations, and provide clearer labeling text. Slopes appear to
exceed 3:1. A variance should be requested for slopes that exceed 3:1.
Clearly show the areas in need of a slope variance. What is the proposed
stabilization method for slopes that exceed 3:1?
6. Stormwater detention ordinance applies to this property. Maintenance of
the detention pond and all private drainage improvements is the
responsibility of the developer and/or property owner. Concrete trickle
channels are suggested to be constructed within the detention pond for
ease of maintenance and to reduce ponding.
7. If disturbed area is one (1) or more acres, obtain a NPDES stormwater
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
8. Alteration of the water course will require approval from the Little Rock
District of the US Army Corps of Engineers prior to start of work.
9. Show locations of streets and driveways on the west side of South
Shackleford Road.
3
May 17, 2018
SUBDIVISION
ITEM NO.: 2 (Cont.) FILE NO.: S-1812
10. Streetlights are required by Section 31-403 of the Little Rock code of
Ordinances. Provide plans for approval to Traffic Engineering. Streetlights
must be installed prior to platting/certificate of occupancy. Contact Traffic
Engineering Greg Simmons, gsimmonsalittlerock.gov or 501.379.1813 for
more information.
11. Hauling of fill material on or off site over municipal streets and roads
requires approval prior to a grading permit being issued. Contact Public
Works Traffic Engineering at 621 South Broadway Street, Travis Herbner,
therbner@littlerock.gov or 501.379.1805 for more information.
12. The private street shall be constructed with a concrete apron.
13. In accordance with Section 32-8, no obstruction to visibility shall be located
within a triangular area from the intersecting right-of-way line (or intersecting
tangent lines for radial dedications) at the intersection of Rowanwood Drive
with South Shackleford Road. This intersection is less than a 90 degree
angle.
14. Per the Master Street Plan, parking is restricted to one side of the street on
a 24-foot wide street. Show on the plan now and on the final plat and bill of
assurance, the area along the private streets where parking is restricted.
15. No residential waste collection service will be provided on private streets
unless the property owners association provides a waiver of damage claims
for operations on private property. For collection service in the rear alleys,
the alley pavement must be at least 20-feet wide and the receptacles taken
to one (1) side of the alley.
16. Traffic calming devices are required for long straight streets to discourage
speeding. Traffic circles, round -a -bouts, speed tables, and narrowing are
suggested at regular intervals and at main intersections. Contact Traffic
Engineering, Travis Herbner, the rhnerQlittlerock-go or 501.379.1805 for
additional information. Show the proposed devices and locations.
17. Damage to public and private property due to hauling operations or
operation of construction related equipment from a nearby construction site
shall be repaired by the responsible party prior to issuance of a certificate of
occupancy.
18. Retaining walls designed to exceed 15-feet in height are required to seek a
variance for construction. Provide proposed wall elevations.
19. Prior to construction of retaining walls, an engineer's certification of design
and plans must be submitted to Public Works for approval. After
construction, an as -built certification is required for construction of the
retaining wall.
20. A minimum undisturbed strip 25-feet wide except for reasonable access
shall be provided along each side of streams having a 10 year storm >150
4
May 17, 2018
SUBDIVISION
ITEM NO.- 2
FILE NO.: S-1812
cfs. The undisturbed strip should be measured from the top of the bank.
Provide the ten (10) year storm flow.
21. The owner and/or manager of each multi -family residence of 100 or more
dwelling units shall provide recycling and encourage participation by the
tenants, renters, or owners of each unit. Contact Melinda Glasgow,
mglasgow,@littlerock.govov or 501.371.4646 for more information.
22. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
23. Show proposed location(s) of USPS cluster box units in conformance with
USPS and City of Little Rock policy design standards.
24. Submit a Traffic Impact Study for the proposed project. Study should
address trip generation and trip distribution for the development and also
should take into account existing and projected traffic growth.
25. Show driveway location for Phase 2.
E. Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authorit : Sewer main extension required with
easements if new sewer service is required for this project. Capacity fee
calculation required. Retain easements for existing sewer line. Contact Little
Rock Water Reclamation Authority for additional information.
Entergy: Entergy does not object to this proposal. There do not appear to be
any conflicts with existing electrical utilities at this location. A three phase
overhead electrical power line runs along the west side of South Shackelford
Road just to the south of this project, and another one exists on Aldersgate Road
just to the east of the project. Contact Entergy in advance to discuss electrical
service requirements, or adjustments to existing facilities (if any) as this project
proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review. Contact Central Arkansas Water regarding procedures for installation
of water facilities and/or fire service. Approval of plans by the Arkansas
5
May 17, 2018
SUBDIVISION
ITEM NO.: 2 (Cont.
FILE NO.: S-1812
Department of Health Engineering Division and the Little Rock Fire
Department is required.
3. This development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate pressure
and fire protection.
4. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
5. Additional fire hydrant(s) will be required. Contact the Little Rock Fire
Department to obtain information regarding the required placement of the
hydrant(s) and contact Central Arkansas Water regarding procedures for
installation of the hydrant(s).
6. A Capital Investment Charge based on the size of meter connection(s) will
apply to this project in addition to normal charges. This fee will apply to all
connections including metered connections off the private fire system.
Fire Department:
Access roads: Fire Apparatus Access Roads shall conform to all the
requirements of Chapter 5 and Appendix D of the 2012 Arkansas Fire Prevention
Code, Vol. 1. Specifically addressed are required access, construction & design
specifications, access road gates, signs, driveway widths of structures with
hydrants, aerial fire apparatus access roads, aerial fire apparatus roads distance
to structure, fire lane markings, commercial & industrial developments, and
residential developments. Locations and extent of fire lane markings must be
approved by the fire code official and is subject to change at any time upon field
evaluation. Contact Capt. Tony Rhodes at (501) 918-3757.
Addresses: Addresses shall be posted in a conspicuous place during
construction and when construction is complete as per Little Rock City Ordinance
Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol.
1 to facilitate emergency response. Numbers/Letters shall be Arabic numbers or
alphabetic letters to be minimum 6" in height, of a durable, reflective material on
a color contrasting background to promote enhanced visibility. The numbers hall
be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on
which the number is based. Whenever any building is situated so that the
number is not clearly discernible from the street line or vision of the building from
the street is otherwise obscured, the number or numbers assigned shall be
placed near the walk, driveway or common entrance to such buildings, and
affixed upon a gate post, fence, mailbox, post, or other appropriate place so as to
be easily discernible (this is in addition to the numbers/letters on the building).
Numbers painted or stenciled on the curb shall not be a lawful substitute for the
A
May 17, 2018
SUBDIVISION
ITEM NO.: 2 (Cont.
FILE NO.: S-1812
display of address numbers prescribed by this article. Subject to change upon
field evaluation. Contact Capt. Tony Rhodes at (501) 918-3757.
Apparatus Access — FDC-hydrant: The LR Fire Department must approve the
proposed location of the building's Fire Department Connection [FDC]. Per 2012
Arkansas Fire Prevention Code, Vol. 1, Section 912.2. With respect to hydrants,
driveways, buildings and landscaping, fire department connections shall be so
located that fire apparatus and hose connected to supply the system will not
obstruct access to the buildings for other fire apparatus, this includes parking
spaces in between, and around the FDC and the fire apparatus access road.
FDC shall be located on the street side of buildings, fully visible and recognizable
from the street or nearest point of fire department vehicle access or as otherwise
approved. A remote FDC is recommended and location must be approved.
Signage of at least 6 inches high, red letters on white background, with "FDC"
must be mounted above the FDC to be visible from fire apparatus access road.
Subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes
at (501) 918-3757.
Parks and Recreation: No comment received.
County Planning: No comment.
F. Building Codes/Landsca e:
Building Code: Project is subject to full commercial plan review and approval
prior to issuance of a building permit. For information on submittal requirements
and the review process. This project will require fully developed Architectural,
Structural, Civil and MEP Plans. Contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichey _littlerock.go .
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. Transportation/Planning:
Rock Re ion Metro: No comment received.
Planning Division: No comment-
7
May 17, 2018
SUBDIVISION
ITEM NO.: 2 Cont. FILE NO.: S-1812
H. SUBDIVISION COMMITTEE COMMENT: (April 25, 2018)
Mr. Mark Redder of Holloway Engineering, Surveying and Civil Design was
present representing the request. Staff presented an overview of the item stating
there were few outstanding technical issues in need of addressing related to the
site plan. Staff requested the applicant provide details concerning the proposed
signage plan. Staff also requested additional information concerning the
proposed future Phase II building or for the applicant to remove the building from
the site plan until the development plans were secured.
Public Works comments were addressed. Staff stated the new back of curb on
South Shackleford Road should be 59-feet from the west curb line. Staff stated
striping should be provided for a lane shift and left turn lane into the site and
Shackleford Pass with tapers. Staff stated additional paving and striping beyond
the property line was needed for turn lane tapers to meet the various standards.
Staff questioned if the request included advanced grading of the Phase 2 portion
of the development with the development of Phase 1. Staff questioned if any
walls would exceed 15-feet in height. Staff also questioned if there would be
grades steeper than 3:1 slopes.
Landscaping comments were addressed. Staff stated no land use buffers were
required since the abutting properties were not zoned or used as single-family
and duplex.
Staff noted the comments from the various other departments and agencies.
Staff suggested the applicant contact the departments or agencies directly with
any questions or concerns. There were no more issues for discussion. The
Committee then forwarded the item to the full Commission for final action.
I. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the
technical issues associated with the request. The applicant has provided the
proposed signage plan and removed the building from the Phase II portion of the
development. The request is for Subdivision/Multiple Building Site Plan Review
as per Section 31-13 of the Little Rock Code of Ordinances. The property
contains 21.97-acres and is zoned MF-12. The development is proposed with
4.37 units per acre.
The development is proposed with single story multi -family residential units
located on the east side of the creek. The plan indicates 30 buildings containing
a total of 96 units within this portion of the development. The development is
proposed with a private gated street. No connection to Aldersgate Road is
proposed with the new development. The plan indicates an emergency access
May 17, 2018
SUBDIVISION
ITEM NO.: 2 (Cont.
FILE NO.: S-1812
drive extending from Aldersgate Road to Rowanwood Drive, within the
subdivision.
The applicant indicates the intent is to impact the existing creek as little as
possible but box culverts to tie in the existing drainage due to the required
widening on South Shackleford Road will be required. The applicant indicates an
extensive amount of earth work will be required for the development. The
applicant is seeking approval of a variance request from the Land Alteration
Ordinance to allow grading of the entirety of the property with the development of
the first phase.
The applicant notes there will be multiple segmental block walls needed within
the development. The application indicates no wall height will exceed the 15-foot
maximum wall height as allowed by the Land Alteration Ordinance.
The site plan includes grading to the property lines in a number of location. The
Zoning Ordinance, Section 36-522(b), states buffers for multi -family
developments are only required where abutting single-family and duplex use or
zoning. The property to the north is zoned OS, Open Space. The property to the
east is zoned MF-18 and the property to the south is zoned 0-3, General Office
District and MF-12.
The plan indicates the placement of a monument sign located along South South
Shackleford Road. The sign is indicated with a maximum height of six (6) feet
and a maximum sign area of 24 square feet.
The plan includes a mail kiosk at the entrance to the subdivision. The site plan
includes the placement of five (5) parking spaces for the residents to park out of
the driveway while accessing the mail kiosk.
The plan includes the placement of a six (6) foot iron decorative fence along the
Shackleford Road frontage. Along the remaining perimeters a six (6) foot wood
fence will be installed.
Ordinance No. 20,839 adopted by the Little Rock Board of Directors on February
11, 2014, modified Section 31-13(f) of the Little Rock Code to limit the term of
approval of a site plan to a maximum of three (3) years from the date of approval.
If an approved multi -phase development, has not been completed within three (3)
years of the date of approval the site plan must be reviewed and reapproved by
the Commission in the same manner as the initial site plan review.
There are a number of technical issues which have not been resolved related to
the development plan. The applicant has not provided the requested traffic
analysis. The applicant also has not provided a letter certifying the sight distance
l~
May 17, 2018
SUBDIVISION
ITEM NO.: 2 (Cont.
of the proposed driveway locatio
on these issues and provide a
hearing.
J. STAFF RECOMMENDATION:
FILE NO.: S-1812
n
. Staff will continue to work with the applicant
recommendation at the May 17, 2018, public
Staff recommendation forthcoming.
PLANNING COMMISSION ACTION:
(MAY 17, 2018)
The applicant was present. There were no registered objectors present. Staff
presented the item stating the applicant had addressed their concerns with regard to the
traffic analysis and the proposed grading plan. Staff stated they were in support of the
request. Staff presented a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation of approval of the variance
request from the City's Land Alteration Ordinance to allow grading of both phases with
the development of the first phase. There was no further discussion. The item was
placed on the consent agenda and approved as recommended by staff by a vote of
8 ayes, 0 noes and 3 absent.
10
ITEM NO.: 2,
NAME: Rowanwood Subdivision Site Plan Review
S-1812
LOCATION: located on the East side of South Shackleford Road in the 2700 — 3300 Blocks
Planning Staff Comments:
1. Provide notification of all property owners located within 200-feet of the site including the
certified abstract list, notice form with affidavit executed and proof of mailing. The notice
must be mailed no later than May 2, 2018. The Office of Planning and Development must
receive the proof of notice no later than May 11, 2018.
2. Provide details of the proposed future building, include the proposed parking layout,
maximum building height, dimensions from the property lines or remove the building from
the site plan.
3. Provide details of the proposed signage plan. Include the location of any ground signage
and the location of any proposed building signage.
4. Provide details of any proposed fencing. Include the location, total height and
construction materials.
5. Is there a community center or any areas of indoor or outdoor recreational activities?
6. Provide a drawing with less detail such as section lines, contours, proposed contours.
7. Will the retaining wall exceed 15-feet in height? If so request a variance.
8. Provide the location of the proposed mail kiosk. The postal service has indicted they will
not access private developments or streets.
Variance/Waivers: None requested.
Engineering Comments:
Public Works Conditions:
1. Shackleford Road is classified on the Master Street Plan as a minor arterial. A dedication
of right-of-way 45-feet from centerline or back of the new sidewalk will be required.
2. With site development, provide the design of street conforming to the Master Street Plan.
Construct one-half street improvement to Shackleford Road including 5-foot sidewalks
with the planned development. The new back of curb should be located 59 feet from west
curb line. Striping should be provided for a lane shift and left turn lane into site and
Shackleford Pass with tapers. Additional paving and striping beyond the property line
maybe needed for turn lane tapers to meet AASHTO and MUTCD standards. Half street
improvements should be made to Shackleford Road adjacent to the subject property. The
existing culvert under Shackleford Road should be lengthened. Provide a revised plan
showing the existing and proposed street and drainage improvements, driveways,
intersecting streets, and striping.
3. Private access is proposed for these lots. In accordance with Section 31-207, private
streets must be designed to the same standards as public streets. A minimum access
easement width of 45-feet is required and street width of 24-feet from back of curb to back
ITEM NO.: 2. S-1812
4. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to
any land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of
construction. Is an advanced grading permit being requested to grade and clear Phase 2
with the issuance of a grading permit for Phase 1?
5. Provide a sketch grading and drainage plan showing the centerline of the creek, label
elevations, and provide clearer labeling text. Slopes appear to exceed 3:1. A variance
should be requested for slopes that exceed 3:1. Clearly show the areas in need of a
slope variance. What is the proposed stabilization method for slopes that exceed 3:1?
6. Stormwater detention ordinance applies to this property. Maintenance of the detention
pond and all private drainage improvements is the responsibility of the developer and/or
property owner. Concrete trickle channels are suggested to be constructed within the
detention pond for ease of maintenance and to reduce ponding.
7. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the
Arkansas Department of Environmental Quality prior to the start of construction.
8. Alteration of the water course will require approval from the Little Rock District of the US
Army Corps of Engineers prior to start of work.
9. Show locations of streets and driveways on the west side of Shackleford Road.
10.Streetlights are required by Section 31-403 of the Little Rock code of Ordinances.
Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineering Greg Simmons,
gsimmons@littlerock.gov or 501.379.1813 for more information.
11. Hauling of fill material on or off site over municipal streets and roads requires approval
prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621
South Broadway Street, Travis Herbner, therbner@littlerock.gov or 501.379.1805 for more
information.
12. The private street shall be constructed with a concrete apron.
13.In accordance with Section 32-8, no obstruction to visibility shall be located within a
triangular area from the intersecting right-of-way line (or intersecting tangent lines for
radial dedications) at the intersection of Rowanwood Drive with Shackleford Road. This
intersection is less than a 90 degree angle.
14. Per the Master Street Plan, parking is restricted to one side of the street on a 24 foot wide
street. Show on the plan now and on the final plat and bill of assurance, the area along
the private streets where parking is restricted.
15. No residential waste collection service will be provided on private streets unless the
property owners association provides a waiver of damage claims for operations on private
property. For collection service in the rear alleys, the alley pavement must be at least 20
feet wide and the receptacles taken to one (1) side of the alley.
16.Traffic calming devices are required for long straight streets to discourage speeding.
Traffic circles, round -a -bouts, speed tables, and narrowing are suggested at regular
intervals and at main intersections. Contact Traffic Engineering, Travis Herbner,
therbnerC@Iittlerock.gov or 501.379.1805 for additional information. Show the proposed
devices and locations.
17. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by the
responsible party prior to issuance of a certificate of occupancy.
ITEM NO.: 2, S-1812
18. Retaining walls designed to exceed 15-feet in height are required to seek a variance for
construction. Provide proposed wall elevations.
19. Prior to construction of retaining walls, an engineer's certification of design and plans must
be submitted to Public Works for approval. After construction, an as -built certification is
required for construction of the retaining wall.
20.A minimum undisturbed strip 25-feet wide except for reasonable access shall be provided
along each side of streams having a 10 year storm >150 cfs. The undisturbed strip
should be measured from the top of the bank. Provide the ten (10) year storm flow.
21.The owner and/or manager of each multi -family residence of 100 or more dwelling units
shall provide recycling and encourage participation by the tenants, renters, or owners of
each unit. Contact Melinda Glasgow, mglasgow@littier_o_ck�clav or 501.371.4646 for more
information.
22. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-
way prior to occupancy.
23. Show proposed location(s) of USPS cluster box units in conformance with USPS and City
of Little Rock policy design standards.
24. Submit a Traffic Impact Study for the proposed project. Study should address trip
generation and trip distribution for the development and also should take into account
existing and projected traffic growth.
25. Show driveway location for Phase 2.
Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority: Sewer main extension required with easements if
new sewer service is required for this project. Capacity fee calculation required. Retain
easements for existing sewer line. Contact Little Rock Water Reclamation Authority for
additional information.
Entergy: Entergy does not object to this proposal. There do not appear to be any conflicts
with existing electrical utilities at this location. A three phase overhead electrical power line
runs along the west side of Shackelford Road just to the south of this project, and another
one exists on Aldersgate Road just to the east of the project. Contact Entergy in advance to
discuss electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
ntral Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water service
must be met.
2. Please submit plans for water facilities and/or fire protection system to Central Arkansas
Water for review. Plan revisions may be required after additional review. Contact Central
Arkansas Water regarding procedures for installation of water facilities and/or fire service.
ITEM NO.
9
S-1812
Approval of plans by the Arkansas Department of Health Engineering Division and the
Little Rock Fire Department is required.
3. This development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire protection.
4. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas
Water. That work would be done at the expense of the developer.
5. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to
obtain information regarding the required placement of the hydrant(s) and contact Central
Arkansas Water regarding procedures for installation of the hydrant(s).
6. A Capital Investment Charge based on the size of meter connection(s) will apply to this
project in addition to normal charges. This fee will apply to all connections including
metered connections off the private fire system.
Fire Department:
Access roads: Fire Apparatus Access Roads shall conform to all the requirements of
Chapter 5 and Appendix D of the 2012 Arkansas Fire Prevention Code, Vol. 1. Specifically
addressed are required access, construction & design specifications, access road gates,
signs, driveway widths of structures with hydrants, aerial fire apparatus access roads, aerial
fire apparatus roads distance to structure, fire lane markings, commercial & industrial
developments, and residential developments. Locations and extent of fire lane markings
must be approved by the fire code official and is subject to change at any time upon field
evaluation. Contact Capt. Tony Rhodes at (501) 918-3757.
Addresses: Addresses shall be posted in a conspicuous place during construction and
when construction is complete as per Little Rock City Ordinance Section 30-346 and Section
505 of the 2012 Arkansas Fire Prevention Code, Vol. 1 to facilitate emergency response.
Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum 6" in height, of
a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the
side of the proper door of each building so that the number can be seen plainly from the
street on which the number is based. Whenever any building is situated so that the number
is not clearly discernible from the street line or vision of the building from the street is
otherwise obscured, the number or numbers assigned shall be placed near the walk,
driveway or common entrance to such buildings, and affixed upon a gate post, fence,
mailbox, post, or other appropriate place so as to be easily discernible (this is in addition to
the numbers/letters on the building). Numbers painted or stenciled on the curb shall not be a
lawful substitute for the display of address numbers prescribed by this article. Subject to
change upon field evaluation. Contact Capt. Tony Rhodes at (501) 918-3757.
Apparatus Access — FDC-hydrant: The LR Fire Department must approve the proposed
location of the building's Fire Department Connection [FDC]. Per 2012 Arkansas Fire
Prevention Code, Vol. 1, Section 912.2. With respect to hydrants, driveways, buildings and
landscaping, fire department connections shall be so located that fire apparatus and hose
connected to supply the system will not obstruct access to the buildings for other fire
apparatus, this includes parking spaces in between, and around the FDC and the fire
apparatus access road. FDC shall be located on the street side of buildings, fully visible and
recognizable from the street or nearest point of fire department vehicle access or as
4
ITEM NO.:
2.
S-1812
otherwise approved. A remote FDC is recommended and location must be approved.
Signage of at least 6 inches high, red letters on white background, with "FDC" must be
mounted above the FDC to be visible from fire apparatus access road. Subject to change at
any time upon field evaluation. Contact Capt. Tony Rhodes at (501) 918-3757.
Parks and Recreation: No comment received.
County Planning: No comment.
Building Codes/Landscape:
Building Code: Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements and the review
process. This project will require fully developed Architectural, Structural, Civil and MEP
Plans. Contact a commercial plans examiner: Curtis Richey at 501.371.4724;
cricheya.I ittle rock. g ov
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance requirements.
2. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
Transportation/Planning:
Rock Re ion Metro: No comment received.
Planning Division: No comment.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, May 2, 2018.
5