HomeMy WebLinkAboutS-1805 Staff AnalysisITEM NO.: 6. S-1805
NAME: Little Rock Tours Subdivision Site Plan Review
LOCATION: located at 3100 Interstate 30
Planning Staff Comments,
1. Provide notification of the abutting property owners including the certified abstract list,
notice form with affidavit executed and proof of mailing. The notice must be mailed no
later than December 27, 2017. The Office of Planning and Development must receive the
proof of notice no later than January 5, 2018.
2. What is the proposed treatment of the western and northern boundaries? The fencing
appears to be chain link fencing with metal slats. This type fencing is prohibited in Little
Rock. Verify the type fencing in place.
3. The plan is difficult to interrupt as to the existing and proposed improvements. Provide a
site plan with a clearer intent for the development.
4. Provide details of the existing and proposed development on the site. Provide the existing
building(s) square footage(s) and the square footage of the new building(s).
5. The plan indicates graveled areas. Will graveled areas remain or will the site be paved?
6. Will there be any additional signage with the proposed new construction? If so provide
details of the proposed signage.
Variance/Waivers: A variance from Section 36-319 to allow a 15-foot rear yard setback for
the construction of an awning covering the proposed drive on the rear of
the building.
Engineering Comments:
Public Works Conditions.
1. Is the drainage easement public or private? Who is the easement in favor of?
2. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to
any land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of
construction.
3. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283 prior
to construction.
4. The property or portion of the property lies within the 100-year floodplain. The lowest
finished floor (including basement) of the proposed structure must be elevated to at least
one (1) foot above the base flood elevation. Attendant utility and sanitary facilities must
be elevated to above the base flood elevation. The finished floor elevation of at least one
(1) foot above the base flood elevation must be shown on the grading plan and all final
plats. An elevation certificate must be provided prior to the issuance of the certificate of
occupancy.
ITEM NO.: 6, S-1805
Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority: Sewer available to this site. EAD Analysis is
required. Contact Little Rock Water Reclamation Authority for additional information.
Entergy: Entergy does not object to this proposal. There do not appear to be any conflicts
with existing electrical utilities based on the information provided. There is an existing three
phase power line running along the west side of the property and one that bisects the
property to the north feeding the cell tower site. Contact Entergy in advance to discuss
electrical service requirements, or adjustments to existing facilities (if any) as this project
proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water: No comment received.
Fire Department-
1 . Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road,
the minimum road width shall be 26 feet, exclusive of shoulders.
2. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not
exceed 10 percent in grade except as approved by the fire chief.
3. Loadincl. Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities,
buildings or portions of buildings hereafter constructed shall be accessible to fire
department apparatus by way of an approved fire apparatus access road with an asphalt,
concrete or other approved driving surface capable of supporting the imposed load of fire
apparatus weighing at least 75,000 pounds.
4. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-
end fire apparatus access roads in excess of 150 feet shall be provided with width and
turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire
apparatus access roads.
5. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus
access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
a. Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
ITEM NO.:
S-1805
b. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
c. Exception: Projects having a gross building area of up to 124,000 square feet
that have a single approved fire apparatus access road when all building are
equipped throughout with approved automatic sprinkler systems.
d. D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of
the maximum overall diagonal dimension of the lot or area to be served,
measured in a straight line between accesses.
6. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30', approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls,
whichever is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of
30 feet from the building, and shall be positioned parallel to one entire side of
the building. The side of the building on which the aerial fire apparatus access
road is positioned shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
7. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
(Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony
Rhodes 501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of
Fire Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
Countv Plannina: No comment.
Building Codes/Landscape:
ITEM NO.: 6.
S-1805
Building Code: Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements and the review
process, contact a commercial plans examiner: Curtis Richey at 501.371.4724 or
crichev@littlerock.gov.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance requirements. Any
new development shall adhere to the current landscape code.
2. Existing vehicular use areas may continue as nonconforming until such time as a building
permit is granted to enlarge or reconstruct a structure on the property exceeding ten (10)
percent of the existing gross floor area. At such time ten (10) percent of the existing
vehicular use area shall be brought into compliance with the landscape ordinance and
shall continue to full compliance on a graduated scale. Verify existing building and
addition square footage.
3. A land use buffer six (6) percent of the average width/depth of the lot will be required
when an adjacent property has a dissimilar use of a more restrictive nature. The property
to the west is zoned R2. The minimum dimension shall in no case be less than nine (9)
feet in width. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be required upon
the property line side of the buffer. In addition to the required screening, buffers are to be
landscaped at the rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet.
4. Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
5. Any existing landscape areas shall be protected as per City of Little Rock Landscape
Ordinance (Sec. 15-100). Any trees or vegetation located in close proximity to
construction shall have the area within the dripline fenced and protected from
development activities. Any exiting landscape, irrigation, or opaque fence adjacent to the
residential property disturbed by construction shall be repaired or replaced before
completion and final acceptance of the project.
6. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
Transportation/Planning:
Rock Region Metro: The site is not located on a dedicated Rock Region Metro Route.
Planning Division: No comment.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, December 27 2017.
ITEM NO.: 6. S-1805
NAME: Little Rock Tours Subdivision Site Plan Review
LOCATION: located at 3100 Interstate 30
Planning Staff Comments:
1. Provide notification of the abutting property owners including the certified abstract list,
notice form with affidavit executed and proof of mailing. The notice must be mailed no later
than December 27, 2017. The Office of Planning and Development must receive the proof
of notice no later than January 5, 2018.
Proof of notification is attached.
2. What is the proposed treatment of the western and northern boundaries? The fencing
appears to be chain link fencing with metal slats. This type fencing is prohibited in Little
Rock. Verify the type fencing in place.
Wood fencing is to be installed along the west property line. Chain link fencing is to
remain along the north property line.
3. The plan is difficult to interrupt as to the existing and proposed improvements. Provide a
site plan with a clearer intent for the development.
A revised site plan and separate demolition plan has been provided.
4. Provide details of the existing and proposed development on the site. Provide the existing
building(s) square footage(s) and the square footage of the new building(s).
Site improvements will included the removal of a 3,550 SF metal building, metal
canopy & columns, 650 SF metal building, and various areas of pavement. The
existing 10,000 SF office metal building will remain and continue serve its current
function. The removed buildings will be replaced with a new 5,760 SF 1-story metal
building maintenance shop and 440 SF paint booth. Existing storm drain will be re-
routed and utilities extended to serve the new building. A new concrete apron will be
installed at the perimeter of the shop.
5. The plan indicates graveled areas. Will graveled areas remain or will the site be paved?
A concrete apron will be installed around the new maintenance building. Existing
gravel pavement to the south will remain.
ITEM NO.: 6. S-1805
6. Will there be any additional signage with the proposed new construction? If so provide
details of the proposed signage.
Potential new signage on the east side of the building elevation is shown on the
previously submitted elevation plans.
Variance/Waivers: A variance from Section 36-319 to allow a 15-foot rear yard setback for
the construction of an awning covering the proposed drive on the rear of
the building.
Engineering Comments:
Public Works Conditions:
1. Is the drainage easement public or private? Who is the easement in favor of?
The existing storm drain being re-routed conveys runoff from New Horizon Lane. The
new easement will be public in favor of the City of Little Rock.
2. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any
land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of
construction.
Will comply.
3. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283 prior to
construction.
Will comply.
4. The property or portion of the property lies within the 100-year floodplain. The lowest
finished floor (including basement) of the proposed structure must be elevated to at least
one (1) foot above the base flood elevation. Attendant utility and sanitary facilities must be
elevated to above the base flood elevation. The finished floor elevation of at least one (1)
foot above the base flood elevation must be shown on the grading plan and all final plats.
An elevation certificate must be provided prior to the issuance of the certificate of
occupancy.
Noted. Will comply.
ITEM NO.: 6. S-1805
Utilities/Fire Department/Parks/County Planning:
Will Comply
Little Rock Water Reclamation Authority Sewer available to this site. EAD Analysis is
required. Contact Little Rock Water Reclamation Authority for additional information.
Enter. : Entergy does not object to this proposal. There do not appear to be any conflicts with
existing electrical utilities based on the information provided. There is an existing three phase
power line running along the west side of the property and one that bisects the property to the
north feeding the cell tower site. Contact Entergy in advance to discuss electrical service
requirements, or adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water: No comment received.
Fire Department:
1. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the
minimum road width shall be 26 feet, exclusive of shoulders.
2. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not
exceed 10 percent in grade except as approved by the fire chief.
3. Loading. Maintain fire apparatus access. road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities,
buildings or portions of buildings hereafter constructed shall be accessible to fire
department apparatus by way of an approved fire apparatus access road with an asphalt,
concrete or other approved driving surface capable of supporting the imposed load of fire
apparatus weighing at least 75,000 pounds.
4. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end
fire apparatus access roads in excess of 150 feet shall be provided with width and
turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire
apparatus access roads.
5. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus
access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
ITEM NO.: 6.
S-1805
a. Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or
facilities exceeding 30 feet or three stories in height shall have at least two means
of fire apparatus access for each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
c. Exception: Projects having a gross building area of up to 124,000 square feet that
have a single approved fire apparatus access road when all building are equipped
throughout with approved automatic sprinkler systems.
d. D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of
the maximum overall diagonal dimension of the lot or area to be served,
measured in a straight line between accesses.
6. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30', approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof surfaces
shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever
is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of 30
feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road
is positioned shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
7. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason
Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes
501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of Fire
Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County Planning No comment.
ITEM NO.: 6,
S-1805
Building Codes/Landscape:
Building Code: Project is subject to full commercial plan review and approval prior to issuance
of a building permit. For information on submittal requirements and the review process, contact
a commercial plans examiner: Curtis Richey at 501.371.4724 or cricheV@littlerock.gov.
Landscape:
Site plan must comply with the City's landscape and buffer ordinance requirements. Any
new development shall adhere to the current landscape code.
Noted.
2. Existing vehicular use areas may continue as nonconforming until such time as a building
permit is granted to enlarge or reconstruct a structure on the property exceeding ten (10)
percent of the existing gross floor area. At such time ten (10) percent of the existing
vehicular use area shall be brought into compliance with the landscape ordinance and shall
continue to full compliance on a graduated scale. Verify existing building and addition
square footage.
Noted. Existing and new building square footages have been added to the site plan.
3. A land use buffer six (6) percent of the average width/depth of the lot will be required when
an adjacent property has a dissimilar use of a more restrictive nature. The property to the
west is zoned R2. The minimum dimension shall in no case be less than nine (9) feet in
width. As a component of all land use buffer requirements, opaque screening, whether a
fence or other device, a minimum of six (6) feet in height shall be required upon the property
line side of the buffer. In addition to the required screening, buffers are to be landscaped
at the rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet.
Will comply. An 11.5' buffer is shown along the west property line.
4. Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing of
not less than thirty (30) feet.
Noted.
ITEM NO.: 6. S-1805
5. Any existing landscape areas shall be protected as per City of Little Rock Landscape
Ordinance (Sec. 15-100). Any trees or vegetation located in close proximity to construction
shall have the area within the dripline fenced and protected from development activities.
Any exiting landscape, irrigation, or opaque fence adjacent to the residential property
disturbed by construction shall be repaired or replaced before completion and final
acceptance of the project.
Noted.
6. The City Beautiful Commission recommends preserving as many existing trees as feasible
on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when
preserving trees of six (6) inch caliper or larger.
Noted.
Transportation/Planning:
Will comply
Rock Region Metro: The site is not located on a dedicated Rock Region Metro Route,
Planning Division: No comment.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, December 27 2017.
ITEM NO.: 7. Z-4324-A
NAME: ACE General Contractors Short -form PID
LOCATION: located in the 11400 Block of Stagecoach Road
Planning Staff Comments:
1. Provide notification of the abutting property owners including the certified abstract list,
notice form with affidavit executed and proof of mailing. The notice must be mailed no later
than December 27, 2017. The Office of Planning and Development must receive the proof
of notice no later than January 5, 2018.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, December 27 2017.
April 5, 2018
ITEM NO, A FILE NO.: S-1805
NAME: Little Rock Tours Subdivision Site Plan Review
LOCATION: Located at 3100 Interstate 30
DEVELOPER
Little Rock Tours, Inc.
3100 Interstate 30
Little Rock, AR 72206
OWNER/AUTHORIZED AGENT:
Carey Martin, Little Rock Tours, Owner
Crafton Tull and Associates, Agent
SURVEYOR/ENGINEER:
Crafton, Tull and Associates
10825 Financial Centre Parkway, Suite 300
Little Rock, AR 72211
AREA: 1.87-acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 1 PLANNING DISTRICT: 8 — Central City CENSUS TRACT: 5
CURRENT ZONING: 1-2, Light Industrial District
VARIANCE/WAIVERS: A variance from Section 36-319 to allow a 15-foot rear yard
setback for the construction of an awning covering the proposed drive on the rear of the
building.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is requesting Subdivision/Multiple Building Site Plan Review as per
Section 31-13 of the Little Rock Code of Ordinances. The applicant is proposing
the construction of a 5,760 square foot bus maintenance and service building on
this 1.87-acre site. Access and circulation on the site will not be altered with the
construction of the new building. Service and maintenance functions currently
being performed outdoors will be moved into the new building. Storm drainage
and utilities will be rerouted as shown on the site plan to accommodate
April 5, 2018
SUBDIVISION
WWLArkMW-AVlore fi
FILE NO.: S-1805
construction of the new building. Constructed as a single story, the building
fagade materials will consist of split face block and metal building panels.
The request includes a variance from Section 36-319 to allow a 15-foot rear yard
setback for the construction of an awning covering the proposed drive on the rear
of the building.
B. EXISTING CONDITIONS:
Little Rock Tours is located on the property which contains two (2) buildings.
A portion of the area to the west is a single-family subdivision and there is a
single-family home located to the north of the site. Interstate 30 is the property's
eastern boundary. South of the site is Ryder Truck Rental. The 1-30 access road
is one-way south bound adjacent to this site.
C. NEIGHBORHOOD COMMENTS:
All abutting property owners along with the CONO - Community Outreach
Neighborhood Association were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Is the drainage easement public or private? Who is the easement in favor of?
2. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other than
residential subdivisions, site grading and drainage plans must be submitted
and approved prior to the start of construction.
3. A special Grading Permit for Flood Hazard Areas will be required per Section
8-283 prior to construction.
4. The property or a portion of the property lies within the 100-year floodplain.
The lowest finished floor (including basement) of the proposed structure must
be elevated to at least one (1) foot above the base flood elevation. Attendant
utility and sanitary facilities must be elevated to above the base flood
elevation. The finished floor elevation of at least one (1) foot above the base
flood elevation must be shown on the grading plan and all final plats. An
elevation certificate must be provided prior to the issuance of the certificate of
occupancy.
2
April 5, 2018
SUBDIVISION
ITEM NO.: A Cont. FILE NO.: S-1805
E. Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authorit : Sewer available to this site. EAD
Analysis is required. Contact Little Rock Water Reclamation Authority for
additional information.
Entergy: Entergy does not object to this proposal. There do not appear to be
any conflicts with existing electrical utilities based on the information provided.
There is an existing three phase power line running along the west side of the
property and one that bisects the property to the north feeding the cell tower site.
Contact Entergy in advance to discuss electrical service requirements, or
adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water: No comment received.
Fire Department:
1. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet,
exclusive of shoulders.
2. Grade. Maintain fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire
apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
3. Loading. Maintain fire apparatus access road design as per Appendix D of
the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed
shall be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at
least 75,000 pounds.
4. Dead Ends. Maintain fire apparatus access roads at dead end locations as
per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of
150 feet shall be provided with width and turnaround provisions in accordance
with Table D103.4. Requirements for Dead-end fire apparatus access roads.
3
April 5, 2018
SUBDIVISION
ITEM NO.: A (Cont.
FILE NO.: S-1805
5. Commercial and Industrial Developments — 2 means of access. - Maintain
fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1
a. Section D104.1 Buildings exceeding three stories or 30 feet in
height. Building or facilities exceeding 30 feet or three stories in
height shall have at least two means of fire apparatus access for
each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area.
Buildings or facilities having a gross building area of more than
62,000 square feet shall be provide with two separate and
approved fire apparatus access roads.
c. Exception: Projects having a gross building area of up to
124,000 square feet that have a single approved fire apparatus
access road when all building are equipped throughout with
approved automatic sprinkler systems.
d. D104.3 Remoteness. Where two fire apparatus access roads are
required, they shall be placed a distance apart equal to not less
than one half of the length of the maximum overall diagonal
dimension of the lot or area to be served, measured in a straight
line between accesses.
6. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the
grade plane and the highest roof surface exceed 30', approved
aerial fire apparatus access roads shall be provided. For the
purposes of this section the highest roof surfaces shall be
determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet
walls, whichever is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a
minimum unobstructed with of 26', exclusive of shoulders, in the
immediate vicinity of the building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access
routes meeting this condition shall be located within a minimum of
15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the
building on which the aerial fire apparatus access road is positioned
shall be approved by the fire code official.
4
April 5, 2018
SUBDIVISION
ITEM NO.: A (Cont.
FILE NO.: S-1805
d. D105.4 Obstructions. Overhead utility and power lines shall not be
located over the aerial fire apparatus access road or between the
aerial fire apparatus road and the building. Other obstructions shall
be permitted to be places with the approval of the fire code official.
7. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the
2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction
with Central Arkansas Water (Jason Lowder 501.377.1245) and the
Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or
Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants
as per Table C105.1.
Parks and Recreation: No comment received.
County Planning: No comment.
F. Building Codes/Landscape:
Building Code: Project is subject to full commercial plan review and approval
prior to issuance of a building permit. For information on submittal requirements
and the review process, contact a commercial plans examiner: Curtis Richey at
501.371.4724 or cricheyCa)-littlerock.gov.
Landscape.
1. Site plan must comply with the City's landscape and buffer ordinance
requirements. Any new development shall adhere to the current landscape
code.
2. Existing vehicular use areas may continue as nonconforming until such time
as a building permit is granted to enlarge or reconstruct a structure on the
property exceeding ten (10) percent of the existing gross floor area. At such
time ten (10) percent of the existing vehicular use area shall be brought into
compliance with the landscape ordinance and shall continue to full
compliance on a graduated scale. Verify existing building and addition square
footage.
3. A land use buffer six (6) percent of the average width/depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive
nature. The property to the west is zoned R-2, Single-family. The minimum
dimension shall in no case be less than nine (9) feet in width. As a component
of all land use buffer requirements, opaque screening, whether a fence or
other device, a minimum of six (6) feet in height shall be required upon the
property line side of the buffer. In addition to the required screening, buffers
are to be landscaped at the rate of one (1) tree and three (3) shrubs for every
thirty (30) linear feet.
5
April 5, 2018
SUBDIVISION
ITEM NO.: A (Cont.) FILE NO.: S-1805
W
7
4. Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape area.
Provide trees with an average linear spacing of not less than thirty (30) feet.
5. Any existing landscape areas shall be protected as per City of Little Rock
Landscape Ordinance (Sec. 15-100). Any trees or vegetation located in close
proximity to construction shall have the area within the dripline fenced and
protected from development activities. Any exiting landscape, irrigation, or
opaque fence adjacent to the residential property disturbed by construction
shall be repaired or replaced before completion and final acceptance of the
project.
6. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
Transportation/Planning-
Rock Region Metro: The site is not located on a dedicated Rock Region Metro
Route.
Planning Division: No comment.
SUBDIVISION COMMITTEE COMMENT -
(December 20, 2017)
Mr. Frank Riggins of Crafton Tull and Associates was present representing the
request. Staff presented an overview of the item stating there were few
outstanding technical issues in need of addressing related to the site plan. Staff
questioned the buffers and screening of the areas adjacent to the single-family
homes. Staff also questioned if any additional signage was proposed with the
new development.
Public Works comments were addressed. Staff questioned if the drainage
easement was public or private. Staff stated a special grading permit for flood
hazard areas was required. Staff stated the site was located within the 100-year
flood plain. Staff stated the finished floor of the new building should be located at
least one (1) foot above the base flood elevation.
Landscaping comments were addressed. Staff stated any upgrades to the site
would require compliance with the landscape ordinance minimums based on the
percentage of upgrade. Staff stated any new developed or paved areas were to
comply with the minimum requirements of the landscape ordinance. Staff stated
any existing landscaped areas were to be protected.
L�
April 5, 2018
SUBDIVISION
ITEM NO.: A (Cont.1 FILE NO.: S-1805
Staff noted the comments from the various other departments and agencies.
Staff suggested the applicant contact the departments or agencies directly with
any questions or concerns. There were no more issues for discussion. The
Committee then forwarded the item to the full Commission for final action.
ANAI YSI.q
The applicant submitted a revised site plan to staff addressing most of the
technical issues associated with the request. The applicant has provided a note
on the plan stating a new wood fence will be installed adjacent to the residential
homes. The applicant has indicated new signage is proposed along the eastern
facade of the new building with the new construction.
The applicant is requesting Subdivision/Multiple Building Site Plan Review as per
Section 31-13 of the Little Rock Code of Ordinances. The proposal is to allow
the construction of a 5,760 square foot bus maintenance and service building on
this 1.87-acre site. The plan includes the reworking of a number of the buildings
by removing previous additions and the removal of a number of free standing
buildings. The site improvements include the removal of a 3,550 square foot
metal building, metal canopy and columns, 650 square foot metal building and
various areas of pavement. The existing 10,000 square foot office, metal
building, will remain and continue to serve as its current function, the offices for
Little Rock Tours. The removed buildings will be replaced with a new
5,760 square foot 1-story metal building maintenance shop and a 440 square
foot paint booth. The existing storm drain will be rerouted and utilities extended
to serve the new building. A new concrete apron will be installed at the perimeter
of the shop. The building facade materials will consist of split face block and
metal building panels.
Access and circulation on the site will not be altered with the construction of the
new building. Service and maintenance functions currently being performed
outdoors will be moved into the new building. Storm drainage and utilities will be
rerouted as shown on the site plan to accommodate construction of the new
building. Easements will be relocated, both public and private, and dedicated via
newly recorded easement dedication deed. The applicant is proposing to
connect to the sanitary sewer system to allow the water from the bus washing to
flow into and be contained within the sanitary sewer. If during review the
applicant elects to not connect to the sanitary sewer system the applicant must
contact the Arkansas Department of Environmental Quality to obtain all proper
permits.
The applicant is requesting a variance from Section 36-319 to allow a 15-foot
rear yard setback for the construction of an awning covering the proposed drive
N
April 5, 2018
SUBDIVISION
ITEM NO.: A (Cont.
FILE NO.: S-
on the rear of the building. The property is zoned 1-2, Light Industrial District
which typically requires the placement of a 25-foot rear yard setback.
The Subdivision/Multiple Building Site Plan Review as per Section 31-13 of the
Little Rock Code of Ordinances states Subdivision Site Plan Review is a
development review process that provides for case by case consideration of
project particulars including the provision of parking and landscaping in
accordance with the appropriate ordinances, siting of buildings, and the
relationships with adjoining properties.
Ordinance No. 20,839 adopted by the Little Rock Board of Directors on
February 11, 2014, modified Section 31-13(f) of the Little Rock Code to limit the
term of approval of a site plan to a maximum of three (3) years from the date of
approval. If an approved multi -phase development, has not been completed
within three (3) years of the date of approval the site plan must be reviewed and
reapproved by the Commission in the same manner as the initial site plan review.
Staff is supportive of the applicant's request. The applicant is seeking site plan
approval per Section 31-13 to allow the placement of more than one (1) structure
on a single parcel of property. The applicant is proposing upgrades to the site
including additional landscaping and a new screening fence adjacent to the
residential homes. Although there is a variance to allow a reduced building
setback along the rear property line staff does not feel this will significantly
impact this site or the adjoining homes.
J. STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
Staff recommends approval of the variance request from Section 36-319 to allow
a 15-foot rear yard setback for the construction of an awning covering the
proposed drive on the rear of the building.
PLANNING COMMISSION ACTION:
(JANUARY 11, 2018)
The applicant was present. There were no registered objectors present. Staff
presented the item stating the applicant had submitted a request dated January 8, 2018,
requesting a deferral of this item to the February 22, 2018, public hearing to allow the
developer's time to meet with the adjoining neighborhood. Staff stated the deferral
request would require a waiver of the Commission's By-laws with regard to the late
deferral request. A motion was made to approve the By-law waiver request with regard
0
April 5, 2018
SUBDIVISION
ITEM NO.. A Cont. FILE NO.: S-1805
to the late deferral request. The motion carried by a vote of 11 ayes, 0 noes and
0 absent. There was no further discussion. The item was placed on the consent
agenda and approved as recommended by staff by a vote of 11 ayes, 0 noes and
0 absent.
STAFF UPDATE:
The applicant submitted a request dated February 6, 2018, requesting deferral of this
item to the April 5, 2018, public hearing. Staff is supportive of the deferral request.
PLANNING COMMISSION ACTION: (FEBRUARY 22, 2018)
The applicant was present. There were no registered objectors present. Staff stated
the applicant had submitted a request dated February 6, 2018, requesting deferral of
this item to the April 5, 2018, public hearing. Staff stated they were supportive of the
deferral request. There was no further discussion. The item was placed on the consent
agenda and approved as recommended by staff by a vote of 10 ayes, 0 noes and
1 absent.
STAFF UPDATE:
The applicant submitted a revised site plan to staff which has relocated the proposed
new construction. The proposed project includes the construction of a 5,760 square
foot bus maintenance and service building on this 1.87-acre site. Since the initial site
plan submittal, the proposed building location has been moved north on the property to
allow for the transition between the current site elevation and the finished floor elevation
needed to meet flood plain development requirements.
Access and circulation on the site will not be altered with the construction of the new
building. The service and maintenance functions currently being performed outdoors
will be moved into the new building. Storm drainage and utilities will be rerouted as
indicated on the site plan to accommodate construction of the new building. An existing
utility easement will be relocated with the new construction.
Construction is proposed as a single story. The building fagade materials will consist of
split face block and metal building panel.
The applicant is requesting a variance to allow a 15-foot rear yard setback. This
request is to accommodate the construction of an awning covering the proposed drive
on the rear of the building. Based on the orientation of the lots when the lots were
E
April 5, 2018
SUBDIVISION
ITEM NO.: A Cont. FILE NO.: S-1805
platted this would typically be a side yard setback. Based on the way the property has
developed staff is reviewing and considered this as the rear yard.
Staff continues to support the applicant's request. The applicant is seeking approval to
allow the removal of an existing metal building and the allowance of construction of the
new maintenance building. The plan also indicates the placement of a small, 28-foot by
16-foot paint booth. To staffs knowledge there are no remaining outstanding technical
issues associated with the request. Staff feels the new construction as proposed is
appropriate.
Staff recommends approval of the request subject to compliance with the comments
and conditions as outlined in paragraphs D, E and F of the agenda staff report.
Staff recommends approval of the variance request from Section 36-319 to allow a
15-foot rear yard setback for the construction of an awning covering the proposed drive
on the rear of the building.
PLANNING COMMISSION ACTION: (APRIL 5, 2018)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation of approval of the variance
request from Section 36-319 to allow a 15-foot rear yard setback for the construction of
an awning covering the proposed drive on the rear of the building. There was no further
discussion. The item was placed on the consent agenda and approved as
recommended by staff by a vote of 10 ayes, 0 noes, 0 absent and 1 recusal
(Commissioner Keith Cox).
10