Loading...
HomeMy WebLinkAboutS-1777 Staff AnalysisITEM NO.: 4, S-1777 NAME: The Parks Subdivision Preliminary Plat LOCATION: located on the south side of Mann Road in the 9600 — 9700 Block Planninq Staff Comments: 1. Provide notification of the abutting property owners of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than July 27, 2016. The Office of Planning and Development must receive the proof of notice no later than August 5, 2016. 2. How will the trail system be maintained, what is the proposed construction material for the trails, how will the area of the trails not be incorporated into the lots of the lots abutting the tract. Will the developer install fences along the property lines which abut the trail system with the construction of the new homes? 3. Dimension the front building setback. It appears the setback proposed is 25-feet. Are the side and rear yard setbacks proposed as typically required per the R-2, Single-family zoning district? 4. Provide the proposed phasing plan for the subdivision. 5. Provide a note on the preliminary plat stating the purpose for the numbering system. VarianceNVaivers: A request to allow the option of the development of an internalized pedestrian circulation system (Section 31-175(2)) in -lieu of sidewalks. Public Works Conditions: 1. Mann Road is classified on the Master Street Plan as a collector street. A dedication of right-of-way 30 feet from centerline will be required. 2. With site development, provide the design of street conforming to the Master Street Plan. Construct one-half street improvement to Mann Road including 5-foot sidewalks with the planned development. The new back of curb should be located 18 feet from centerline. Additional widening to 24 feet from centerline, tapers, and striping should be provided for lane shifts and west bound left turn lanes. Additional paving maybe required to comply with AASHTO guidelines. 3. Provide phasing plan for subdivision construction. Proposed improvements to Mann Road cannot be deferred to the last construction phase. 4. A grading permit in accordance with Section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advance grading variance requested to advance grade future phases of the subdivision with the issuance of a grading permit for the previous phase? If a variance is being requested, undisturbed buffers or berms should be maintained as found in the Land Alteration Regulations. 5. The proposed trail system layout will require pedestrians to walk in high traffic volume streets where sidewalks are required to be installed per the Master Street Plan are not ITEM NO.: 4. S-1777 proposed by this plan. Sidewalk should be provided adjacent to public streets and/or additional trails provided for better connectivity between homes and trails. Access considerations should be given for fenced in yards. 6. Provide a Sketch Grading and Drainage Plan per Section 29-186 due to the large drainage areas at the rear of lots. 7. Stormwater detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owners association as detailed in the bill of assurance. 8. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. 9. Streetlights are required by Section 31-403 of the Little Rock code of ordinances. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Greg Simmons, Traffic Engineering, 501.379.1813, gsimmons@littlerock.orq for more information. 10. Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 11.All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. 12.All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. 13.Access to detention ponds must be provided to the public right-of-way and/or access easement for future maintenance by the developer and/or local property owners' association. 14. Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley 501.371.4537, q hale little rock. or . Cascade Lane is a duplication and cannot be used. Big Bend Lane is too long in distance to be labeled as a lane. Consideration should be given to rename to "Drive". 15. If Big Bend Lane is constructed to a residential standard street, the minimum radius is 150 feet normal crown. 16.Additional traffic calming measures should be provided on Big Bend Lane on the east side of the development. 17. Big Bend Lane and Glacier Bay Drive should be constructed to a residential collector standard of 31 feet wide with sidewalk on one (1) side or a trail system due to the expected volume of traffic. The minimum radius should be 275 feet normal crown or 235 feet super -elevated. 18. Due to the proposed configuration, there is limited sight distance at the intersection of Big Bend Lane and Sequoia Lane. 19.The secondary emergency access should be constructed to the existing pavement of Peace Valley Road. Utilities and Fire Department/County Planning: Little Rock Wastewater: Sewer main extension required with easements if new sewer service is required for the project. Capacity fee analysis required. Contact Little Rock Wastewater Utility for additional information. ITEM NO.: 4. S-1777 Entergy: Entergy Distribution does not object to this proposal. A three phase power line exists along the south side of Mann Road which can be utilized to provide power to this development. However, the project proposes to utilize Entergy Transmission line easements for pedestrian walking trails and a few lots appear to encroach onto the Transmission easements. Contact Entergy Transmission well in advance to discuss the future use of its easements and contact Entergy Distribution well in advance to discuss future service requirements, new Distribution facilities locations and adjustments to existing Distribution facilities (if any) as this project proceeds. Centerpoint Energy: No comment received. AT & T: No comment received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. A water main extension will be needed to provide water service to this property. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be one at the expense of the developer. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department regarding the required placement of the hydrant(s) and contact Central Arkansas Waster regarding procedures for installation for the hydrant(s). 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Fire Department: 1. Maintain Access. 2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. 3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. ITEM NO.: 4. S-1777 4. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. 5. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead- end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. 6. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: a. Minimum gate width shall be 20 feet. b. Gates shall be of swinging or sliding type. c. Construction of gates shall be of material that allow manual operation by one person. d. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. e. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. f. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. g. Locking device specifications shall be submitted for approval \by the fire code official h. Electric gate operators, where provided, shall be listed in accordance with UL 325. i. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. 7. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and all dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. ITEM NO.: 4. S-1777 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. 9. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501,918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Planning: No comment. Rock Region Metro: Location is currently served by METRO on routes 17 and 22. The development of this neighborhood street grid is important for residents to have access to the transit and paratransit services. Dead-end "lollipop" streets and disconnected sidewalk networks will impede resident's access to transit. We recommend along with the neighborhood exits on Mann Road that Peace Valley road be improved and provided as an access exit out of the neighborhood. This will connect the transit route and provide efficient routing for paratransit services. Building Code: No comment. Planning Division: No comment. Landscape: No comment. Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, July 27, 2016. August 11, 2016 ITEM NO.: 4 NAME. The Parks Subdivision Preliminary Plat FILE NO.: S-1777 LOCATION: Located on the south side of Mann Road in the 9600 — 9700 Block DEVELOPER: Town Creek LLC 11324 Arcade Drive Little Rock, AR 72211 FNr�INFFR- White-Daters and Associates 24 Rahling Circle Little Rock, AR 72223 AREA: 120 acres NUMBER OF LOTS: 369 FT. NEW STREET: 15,300 LF WARD: 7 PLANNING DISTRICT: 15 — Geyer Springs West CENSUS TRACT: 41.05 CURRENT ZONING: R-2, Single-family VARIANCE/WAIVERS: A request to allow the option of the development of an internalized pedestrian circulation system (Section 31-175(2)) in -lieu of sidewalks. A. PROPOSAL/REQUESTIAPPLICANT'S STATEMENT. The property is located just south of Mann Road and west of Wilderness Road. The property contains 120-acres with 364 proposed residential lots. The property will be developed in approximately six (6) phases with roughly 60 lots per phase. The lots are proposed 60-feet wide by 120-feet deep. Two (2) access points to Mann Road will be provided. An additional emergency access will be constructed to Peace Valley Road to the south via an all-weather drive. An emergency gate with Knox box will be provided. Mann Road will be improved to collector street standards with a 5-foot sidewalk. The developer is proposing to improve Mann Road in two (2) phases as the adjacent property develops. The developer is proposing the use of an internalized pedestrian circulation system in -lieu of sidewalks throughout the subdivision and to provide access to Morehart Park located to the southwest. Section 31-175 of the Little Rock Code of Ordinances outlines the minimum design requirements for sidewalks. The August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont. FILE NO.: S-1777 ordinances states internalized pedestrian circulation systems in the form of paved pathways may be substituted for sidewalks along collector and residential streets upon approval by the Planning Commission. An Entergy transmission line runs through the property. This easement will allow the pedestrian tail to be easily accessible from all areas of the development. Pedestrian tables will be constructed to slow traffic and create connectivity of the trail system throughout the development. B. EXISTING CONDITIONS: L The site is heavily wooded. There are single-family subdivisions located to the east and south of the proposed development area. To the north is Mann Road and a main railroad line. Across Mann Road to the north is a single-family subdivision. Mann Road is a two (2) lane road with no curb and gutter or sidewalk and open.ditches for drainage. NEIGHBORHOOD COMMENTS: All abutting property owners, the West Baseline Neighborhood Association and Southwest Little Rock United for Progress were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS. 1. Mann Road is classified on the Master Street Plan as a collector street. A dedication of right-of-way 30 feet from centerline will be required. 2. With site development, provide the design of street conforming to the Master Street Plan. Construct one-half street improvement to Mann Road including 5-foot sidewalks with the planned development. The new back of curb should be located 18 feet from centerline. Additional widening to 24 feet from centerline, tapers, and striping should be provided for lane shifts and west bound left turn lanes. Additional paving maybe required to comply with AASHTO guidelines. 3. Provide phasing plan for subdivision construction. Proposed improvements to Mann Road cannot be deferred to the last construction phase. 4. A grading permit in accordance with Section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advance grading variance requested to advance grade future phases of the subdivision with the issuance of a grading permit for the previous phase? 2 August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont. FILE NO.: S-1777 If a variance is being requested, undisturbed buffers or berms should be maintained as found in the Land Alteration Regulations. 5. The proposed trail system layout will require pedestrians to walk in high traffic volume streets where sidewalks are required to be installed per the Master Street Plan are not proposed by this plan. Sidewalk should be provided adjacent to public streets and/or additional trails provided for better connectivity between homes and trails. Access considerations should be given for fenced in yards. 6. Provide a Sketch Grading and Drainage Plan per Section 29-186 due to the large drainage areas at the rear of lots. 7. Stormwater detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner's association as detailed in the bill of assurance. 8. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. 9. Streetlights are required by Section 31-403 of the Little Rock code of ordinances. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Greg Simmons, Traffic Engineering, 501.379.1813, gsimmons(c- Iittlerock.org for more information. 10. Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 11. All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. 12. All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. 13. Access to detention ponds must be provided to the public right-of-way and/or access easement for future maintenance by the developer and/or local property owners' association. 14. Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley 501.371.4537, ghaley(�D-littlerock.orq. Cascade Lane is a duplication and cannot be used. Big Bend Lane is too long in distance to be labeled as a lane. Consideration should be given to rename to "Drive". 3 August 11, 2016 SUBDIVISION EM NO.: 4 (Cont.) FILE NO.: S-1777 15. If Big Bend Lane is constructed to a residential standard street, the minimum radius is 150 feet normal crown. 16. Additional traffic calming measures should be provided on Big Bend Lane on the east side of the development. 17. Big Bend Lane and Glacier Bay Drive should be constructed to a residential collector standard of 31 feet wide with sidewalk on one (1) side or a trail system due to the expected volume of traffic. The minimum radius should be 275 feet normal crown or 235 feet super -elevated. 18. Due to the proposed configuration, there is limited sight distance at the intersection of Big Bend Lane and Sequoia Lane. 19. The secondary emergency access should be constructed to the existing pavement of Peace Valley Road. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Little Rock Wastewater: Sewer main extension required with easements if new sewer service is required for the project. Capacity fee analysis required. Contact Little Rock Wastewater Utility for additional information. Entergy: Entergy Distribution does not object to this proposal. A three phase power line exists along the south side of Mann Road which can be utilized to provide power to this development. However, the project proposes to utilize Entergy Transmission line easements for pedestrian walking trails and a few lots appear to encroach onto the Transmission easements. Contact Entergy Transmission well in advance to discuss the future use of its easements and contact Entergy Distribution well in advance to discuss future service requirements, new Distribution facilities locations and adjustments to existing Distribution facilities (if any) as this project proceeds. Centerpoint Energy: No comment received. AT & T: No comment received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. A water main extension will be needed to provide water service to this property. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation 2 August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont. of water facilities and/or fire service Department of Health Engineering Department is required. FILE NO.: S-1777 Approval of plans by the Arkansas Division and the Little Rock Fire 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department regarding the required placement of the hydrant(s) and contact Central Arkansas Waster regarding procedures for installation of the hydrant(s). 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Fire Department: 1. Maintain Access. 2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. 3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. 4. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. 5. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of I.7 August 11, 2016 SUBDIVISION NO.: 4 (Cont.) FILE NO.: S-1777 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. 6. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria. a. Minimum gate width shall be 20 feet. b. Gates shall be of swinging or sliding type. c. Construction of gates shall be of material that allow manual operation by one person. d. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. e. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. f. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. g. Locking device specifications shall be submitted for approval \by the fire code official h. Electric gate operators, where provided, shall be listed in accordance with UL 325. i. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. 7. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and all dwelling units are equipped throughout with an approved automatic sprinkler system in accordance 9 August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont. FILE NO.: S-1777 with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. 8. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501,918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Planning: No comment. Rock Region Metro: Location is currently served by METRO on routes 17 and 22. The development of this neighborhood street grid is important for residents to have access to the transit and paratransit services. Dead-end "lollipop" streets and disconnected sidewalk networks will impede resident's access to transit. We recommend along with the neighborhood exits on Mann Road that Peace Valley Road be improved and provided as an access exit out of the neighborhood. This will connect the transit route and provide efficient routing for paratransit services. F. ISSUES/TECHN ICAUDESIGN: Building Code: The 2012 AR Fire Prevention Code Vol. III for one (1) and two (2) family dwellings requires foundations meet the following Sections of the Code. If the foundation cannot be verified by the building official at the time of the footing inspection the building official may require verification the foundation meets the required elevation by a licensed engineer. R403.1.7.3 Foundation elevation. On grade sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12-inches (305 mm) plus two (2) percent. R403.1.7.4 Alternate setback and clearances. Alternate- setbacks and clearances are permitted, subject to the approval of the building official. The building official is permitted to require an investigation and recommendation of a qualified engineer to demonstrate that the intent of this Section has been 7 August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont.) FILE NO.: S- L satisfied. Such an investigation shall include consideration of materials, height of slope, slope gradient, load intensity and erosion characteristics of slope material. Please address any questions to the building inspectors at 501.371.4833 or 501.371.4834. Planning Division: No comment. Landscape: No comment. SUBDIVISION COMMITTEE COMMENT: (July 20, 2016) Mr. Joe White of White Daters and Associates was present representing the request. Staff presented an overview of the item stating there were additional items necessary to complete the review process. Staff questioned the dimension of the front building setback. Staff also questioned the proposed phasing plan. Public Works comments were addressed. Staff stated Mann Road was classified on the Master Street Plan as a collector street. Staff stated dedication of right of way and Y2 street improvements were required with the proposed new development. Staff questioned if the street improvements would be completed with the first phase or with later phases. Staff stated the minimum radius for Big Bend Lane was 150-feet. Staff stated additional traffic calming measures should be provided on Big Bend Lane. Staff stated Big Bend Lane and Glacier Bay Drive should be constructed to a residential collector standard with 31-feet of pavement with sidewalk on one (1) side of the street or a trail system due to the expected volume of traffic. Staff noted the comments from the various other departments and agencies. Staff suggested the applicant contact the departments or agencies directly with any questions or concerns. There were no more issues for discussion. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant has provided a revised preliminary plat to staff addressing the technical issues associated with the request raised at the July 20, 2016, Subdivision Committee meeting. The applicant has provided the front building line for the single-family lots. The applicant has also provided the proposed phasing plan. The property contains 120-acres with 364 single-family residential lots. The property will be developed in approximately six (6) phases with roughly 60 lots per phase. The lot numbering system allows for the block number followed by 0 August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont.) FILE NO.: S-1777 the lot number (Lot 171 is Lot 71 in Block 1). The lots are proposed 60-feet wide by 120-feet deep. The lots are indicated with an average lot size of 60-feet by 120-feet and 7,200 square feet. The lots are indicated with a front platted building line of 25-feet. The remaining setbacks will comply with the R-2, Single- family zoning district. Two (2) access points to Mann Road will be provided. An additional emergency access will be constructed to Peace Valley Road to the south via an all-weather drive. An emergency gate with Knox box will be provided. Mann Road will be improved to collector street standards with a 5-foot sidewalk. Mann Road at each entrance will be widened to create a left turn lane into the development. The Phase I improvements will include 430-feet of widening to create a left turn lane into the southern entrance. The improvements with the Phase V portion of the development include completing the improvements to Mann Road and installing an additional 430-feet of widening to create the left turn lane into the second entrance to the subdivision. An Entergy transmission line runs through the property. This easement will allow the pedestrian trail to be easily accessible from all areas of the development. Pedestrian tables will be constructed to slow traffic and create connectivity of the trail system throughout the development. The trail system will be maintained by the Property Owners Association. The internalized pedestrian circulation system will be used in -lieu of the placement of sidewalks throughout the subdivision. Access to Morehart Park, located to the southwest of the subdivision, is indicated on the site plan. Section 31-175 of the Little Rock Code of Ordinances outlines the minimum design requirements for the trail system. The ordinances states internalized pedestrian circulation systems in the form of paved pathways may be substituted for sidewalks along collector and residential streets upon approval by the Planning Commission. The applicant is seeking a variance from the City's Land Alteration Ordinance to allow advanced grading of the lots as each phase is developed. The applicant has indicated the builder purchasing the lots requires that all trees be removed and the lots graded with pad ready site for the new home construction. The request does not include clearing of the entire site with the first phase of development. As each phase is developed then that particular phase will be cleared. Staff is supportive of the applicant's request. The applicant is seeking preliminary plat approval to allow the development of a single-family subdivision at a density of 3.03 units per acre. The lots are indicated with lot sizes and setbacks which fully comply with the R-2, Single-family zoning district. 0 August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont-) FILE NO.: S-1777 STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the comments and conditions as outlined in paragraphs D, E and F of the agenda staff report. Staff recommends approval of the variance request from the City's Land Alteration Ordinance to allow grading of an entire phase of the subdivision with the development of that particular phase. PLANNING COMMISSION ACTION: (AUGUST 11, 2016) The applicant was present. There were registered objectors present. Staff presented the item with a recommendation of approval of the request subject to compliance with the comments and conditions as outlined in paragraphs D, E and F of the agenda staff report. Staff presented a recommendation of approval of the variance request from the City's Land Alteration Ordinance to allow grading of an entire phase of the subdivision with the development of that particular phase. Mr. Shawn Shackleford addressed the Commission in opposition to the request. He stated he and his family owned a testing and inspection company that was located next door to the proposed subdivision. He stated he was licensed with all required state and federal agencies. He stated the terms of his license did not allow for residential development adjacent to his business. He stated if the development was approved his business would be required to move. Ms. Linda Bergin addressed the Commission in opposition of the request. She stated she had a number of concerns related to noise and safety. She stated the site was located with a significant power transmission line running through the property. She stated there had been a number of studies related to illnesses of children living near power lines. She stated the plat indicated homes backing up to power lines and the placement of trails and recreational activities for the subdivision all accessing and located under the power lines. She stated currently the trees were a buffer for the noise of the trains and the freeway. She stated once the trees were removed the noise would increase. She stated the railroad line along Mann Road was the busiest in the country. She stated there were 30 to 50 trains per day running along the track. She stated there were two (2) crossings over the track from Mann Road. She stated at each crossing the train was required to blow the whistle four (4) times. She stated with the loss of the trees the noises would be greater. She stated the adjoining neighborhood was once a nice neighborhood with large homes. She stated this was no longer true. She stated there were 432 homes in the in the City foreclosure. She stated 130 of those homes were in the 72209 zip code. She stated crime was on an issue in the area. She stated there were 75 reported crimes within the general area. She questioned who would want 10 August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont. LE NO.: S-1777 to buy a home that was next to a subdivision that had such a high crime rate and where the homes were rental property. She questioned the placement of the detention areas and the impact on the area and potential insect breeding grounds. Mr. Phillip Abernathy addressed the Commission in opposition of the request. He stated he was a resident of the Legion Hut neighborhood. He stated he was concerned with the loss of the wooded area and the impact that would have on sound. He stated with the removal of the wooded areas noise of the train and the interstate would be heard by the neighborhoods. He questioned the upgrades that would be required by police and fire to serve the new subdivision. He stated the existing schools were at capacity and questioned what upgrades would be required to service the new students. He stated ingress and egress from the subdivision with only access to Mann Road was a concern. He questioned if there was a train derailment how the residents would be evacuated. Ms. Sharon Forrester addressed the Commission in opposition of the request. She stated her home was located on five (5) acres and had a common property line with Morehart Park and Twin Oaks Park. She stated her concern was the area and safety of the residents. She stated she was concerned with the loss of trees and the potential increase in noise. She stated she was concerned that the homes would not sell due to the adjacent neighborhoods. She stated she echoed all the other speakers concerns. She stated she was also concerned residents accessing the park would confuse her property with park land, which has happened in the past, with patrons of the park thinking her property was part of the park. She stated she was concerned how the new subdivision would impact property values in the area. Mr. Joe White addressed the Commission stating the area was once a thriving neighborhood and he felt the area was coming back. He stated with the recent construction of Bass Pro, the Outlets and the new Fed Ex facility he felt people would be looking to the area to buy new homes. He stated new construction typically was a good infusion into an area. He stated Rausch Coleman was committed to build the first 60 homes within the subdivision. He stated the homes did back up to the power lines and the development was taking into consideration the potential impacts of the power lines on the future home sites. He stated the development was not maximizing the land area. He stated the development was right at three (3) units per acre. He stated typical subdivision development, when maximizing the land area, was near four (4) units per acre. He states the detention ponds were dry ponds. He stated they would fill during heavy rains and in a few hours the water would drain out. He stated the developer did not want to construct a wet pond and face the liability that would potentially go along with a wet detention pond. 11 August 11, 2016 SUBDIVISION ITEM NO.: 4 (Cont. FILE NO.: S-1777 Commissioner Laha stated he felt the neighborhood was a great place to live and Southwest United for Progress had voted to support the development. He stated his home was located near the power line and he did not feel there were any adverse impacts of allowing subdivisions to develop around power lines. He stated according to the police department the crime rate in the area was the least of the entire City. He stated there was petty crime all over the City but the major crimes in the area were less in southwest than any other part of Little Rock. Commissioner Bubbus stated he felt the development was good for the area. He stated his home was not far from this area and he felt new single-family with a nice quality developer was an asset for the neighborhoods. There was no further discussion. The chair entertained a motion for approval of the preliminary plat request as recommended by staff. The motion carried by a vote of 9 ayes, 0 noes and 2 absent. A motion was made to approve the variance request from the City's land alteration ordinance. The motion carried by a vote of 9 ayes, 0 noes and 2 absent. 12