Loading...
HomeMy WebLinkAboutS-1735 Staff AnalysisITEM NO.: 2. S-1735 NAME: McCracken Land Development Preliminary Plat LOCATION- located in parts of the 14600 and 14700 Blocks of Kanis Road Planning Staff Comments: 1. Provide notification of the abutting property owners including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than October 15, 2014. The Office of Planning and Development must receive the proof of notice no later than October 24, 2014. 2. The plat includes a variance to allow reduced lot widths for a number of the proposed lots. 3. What are the proposed side and rear yard setbacks? Indicate in a note on the proposed preliminary plat. 4. If a tract is platted along Kanis Road then a number of variances can be avoided, 35-foot platted building line, double frontage lots, restrictive access easement along Kanis Road. Variance/Waivers: Master Street Plan, Advanced grading, Number of lots on a minor residential street, Lot widths Public Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45-feet from centerline will be required. 2. With site development, provide the design of the street conforming to the Master Street Plan. Construct one-half street improvement to Kanis Road including 5-foot sidewalks with the planned development. The new back of curb should be 29.5-feet from centerline. Striping and transitions should be provided for a left turn lane. 3. With 41-lots, a variance from the Master Street Plan must be requested for the proposed street to be classified as a minor residential street. 4. Since the street is proposed to be 24-feet in width, show on the plan the area of street where parking will be restricted to one side. 5. The bulb in the center of the proposed street is ineffective for traffic calming as required by the Master Street Plan. Show on the plan the proposed means of traffic calming. Contact Nat Banihatti in Traffic Engineer at 501.379.1818 with any questions or for additional information. 6. The frontage along Kanis Road where the storm -drain is proposed should be platted as tract land. 7. A no access easement should be platted on the east side of Lot 19. 8. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior ITEM NO.: 2. 5-1735 to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is construction of the subdivision proposed to be phased? 9. Stormwater detention ordinance applies to this property. 10.If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. 11. The lots on the south side of the street should be graded where the front yards of each lot and roof top drain to the street and the rear yards drain to the south. 12. Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 13. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering 501.379.1813, Greg Simmons, for more information. 14. Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley at 501.371.4537. 15. Per Section 29-102 an evaluation should be conducted on the basis of existing downstream development and any analysis of stormwater runoff with and without the proposed development. If the proposed development will cause or increase downstream flooding conditions, provisions to minimize such flooding conditions should be included in the design of the storm management improvements. Such provisions may include downstream improvements and/or detention of stormwater runoff and its regulated discharge to the downstream storm drainage system. 16. Provide a letter prepared by a registered engineer certifying the sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 17. Show the existing driveways adjacent to this property on the west side of Kanis Road. 18.A driveway apron should be provided for the emergency access. The apron could be constructed of concrete or green pavers. Gravel is not allowed. Utilities and Fire Department/County Planning: Wastewater: Sewer main extension required, with easement, if sewer service is required for this project. The property must be annexed into the City limits of Little Rock to receive sewer service. Entergy: Entergy does not object to this proposal. A 3-phase power line is located on Kanis Road. A single phase, overhead power line is located on the rear lot lines of the subdivision to the north. Any service to this subdivision will need to be from the front lot line. Contact Entergy in advance to work out the electrical layout plan. Center -Point Energy: No comment received. AT & T: No comment received. Item # 2. ITEM NO,, 2, IVIC101 Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. 3. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 4. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 5. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). 6. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Fire Department: Turn -around as per Appendix D — 2012 AFC, Access Roads as per Appendix D with fire hydrant D 103.1-2. Hydrants as per 2012 AFAC Code. Contact the Little Rock Fire Department for additional information. County Planning: The property must be annexed into the City limits of the City of Little Rock prior to development. CATA: The area is not currently served by CATA at this location but it is on CATA's long range plans using Kanis Road. The development consists of single family homes. CATA requests consideration of ADA accessible sidewalks at this location and a pullout to enable buses to pull out of traffic to serve this location when improvements are made. Parks and Recreation: No comment received. Building Code: No comment. Planning Division: No comment. Landscape: No comment. Item # 2. ITEM NO.: 2. 5-17 Revised plat/plan _ Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, October 15, 2014. Item # 2. Page 4 Staff Comments: 1.) Provide Letter of Application. 2.) Provide Bill of Assurance. 4.) Suggest Re -titling of Plat. A subdivision named "Kanis Creek" already exists in Pulaski County. 18.) Show Zoning districts for all properties on plat. 23.) Provide summary of development plan. 24.) Lot is part of an existing subdivision. Verify and state on plat that redevelopment of Tract 10 does not violate any covenants and restrictions for original subdivision. 26.) Provide Drainage calculations that verify MS-4 stormwater requirements are met. 27.) Provide approval from West Pulaski Volunteer Fire Dept. 29.) Provide street centerline profile. 31.) Provide Storm drainage plan with calculations for all inlets, ditches/swales etc. 34.) Certificate of Engineering Accuracy refers to City of Maumelle. 38.) Right of Way width for Kanis Creek Drive does not comply with standards for Local Road within Pulaski County (50' R.O.W. for street with curb and gutter.) 56.) Comply with ADEQ Stormwater Pollution Prevention requirements. 57.) Pay $33.00 Review Fee. Additional Staff Comments: -Comments are provided for this plat in the event Subdivision is not annexed into the City of Little Rock prior to beginning construction. -Note #5 on Typical Roadway Section refers to Beau Rivage Drive and Beau Rivage Cove. These streets are not adjacent to this development. -Permits will be required for road improvements and driveways off Kanis Creek and Kanis Road from Pulaski County Public Works. -Public works will review drainage calculations/street design specification once all information is provided. -Add note on plat about Tract B. Public Works Comments: 1.)Provide traffic study showing amount of traffic that would be turning onto Kanis Creek Drive from Kanis Road and exiting Kanis Creek Drive onto Kanis Road. 2.) Provide traffic control plan for all phases of construction. 3.) Provide complete set of drainage plans with profiles. 4.) Show all culvert lengths, grade, material, and size on plans. 5.) Provide all stormwater runoff calculations for all inlets, gutters, ditches, channels, culverts, junctions, and culvert outflows. Provide bypass calculations for all curb inlets. 6.) Delineate all watersheds affecting subdivision drainage. 7.) Show directions of flow for all ditches, gutters, drains and sheet flow. 8.) Provide road profile, stationing and cross sections for Kanis Creek Drive and Kanis Road. 9.) Provide Geotechnical report. 10.) Show Class 7 material extending under curb and gutter. 11.) Provide complete set of building plans. 12.) Provide PCRB with copy of ADEQ stormwater permits. All construction must adhere to ADEQ stormwater regulations. ADEQ permit, SWPPP, rain gauge and inspection reports must be onsite during construction. 13.) Provide complete set of plans for all utilities in Right of Way. 14.) Provide standard detail drawing for all drainage structures. 15.) Show radius data for road intersection flares. 16.) Show property line/right of way radius data for all intersections on plat. 17.) Provide plan for improvements on Kanis Road including typical cross section. 18.) Minimum roadway width should be at least 28 feet without curb and gutter 27 feet with curb and gutter. 19.) Provide building plans for detention pond. 20.) Specify psi strength for all concrete. 21.) Specify control/expansion joint intervals for curb and gutter. 22.) Provide pdf as well as hard copies of all plans and plat. 23.) Show any proposed drainage channels. 24.) Include cross-section detail and dimensions for any needed ditches or channels. 25.) Right of Way Width for Kanis Creek Drive should be 60' for streets without curb and gutter, 50 for streets with curb and gutter. 26.) Show appropriate amount of rip -rap at detention pond outflow. 27.) Provide erosion control plan. 28.) Show all needed signs on plans and standard detail. 29.) Provide PCRB with base course proctor and subgrade proctor. 30.) Include maintenance agreement, in Bill of Assurance, indicating who is responsible for maintenance of all stormwater facilities. 31.) Indicate all EPA 303 (d) listed streams affected by stormwater runoff from this development. 32.) Provide statement indicating contribution to listed cause of pollution for any affected EPA 303(d) listed stream. 33.) Include all 2 year, 10 year, 25 year, 100 year storm event calculations for pre -development and post -development conditions. 34. Include post -construction peak runoff with and without detention. Staff recommendation: Approval Subject to Compliance with Staff Requirements. October 30, 2014 I ITEM NO.: 2 FILE NO.: S-1735 NAME: McCracken Land Development Preliminary Plat LOCATION: Located in parts of the 14600 and 14700 Blocks of Kanis Road DEVELOPER: McCracken Land Development 11815 Hinson Road, Suite C Little Rock, AR 72212 ENGINEER: Holloway Engineering, Surveying and Civil Design, PLLC 200 Casey Drive Maumelle, AR 72113 AREA: 9.36 acres NUMBER OF LOTS: 41 FT. NEW STREET: 1,410 LF CURRENT ZONING PLANNING DISTRICT R-2, Single-family 18 — Ellis Mountain CENSUS TRACT: 42.18 VARIANCENVAIVERS: 1. A variance from the Master Street Plan to allow the development of 41 lots on a minor residential street. 2. A variance from the land alteration ordinance to allow advanced grading of the lots with the installation of the infrastructure and streets for the subdivision. 3. A variance from Section 31-232 to allow the creation of lots with a lot width less than the 60-foot required per the R-2, Single-family zoning district and to allow five (5) foot side yard setbacks on all the lots within the subdivision. A. PROPOSAUREQUESTIAPPLICANT'S STATEMENT: The applicant is requesting preliminary plat approval to allow the creation of 41-lots from a 9.36-acre parcel. The development is proposed with a single street extending north from Kanis Road to a hammer -head turn around with a October 30, 2014 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-1735 secondary all weather emergency access drive located along the southern property line. The preliminary plat as presented creates variances for various City ordinances, to allow lot widths less than the typical ordinance standard of 60-feet and to allow five (5) foot side yard setbacks. Lots 10 — 34 are indicated with lot widths of 52 to 53-feet. The request includes the allowance of five (5) foot side yard setbacks on all the proposed lots. All the lots are proposed to comply with the typical standard for lot area (7,000 square feet) per the R-2, Single-family Zoning District. The request also includes a variance from the City's Land Alteration Ordinance to allow grading of the individual lots with the installation of the street and utilities. The request also includes a variance from the City's Master Street Plan to allow the development of 41-lots on a minor residential street. B. EXISTING CONDITIONS: The site is tree covered located on the north side of Kanis Road approximately 2,000-feet west of the Kanis/Cooper Orbit/Kirby Roads intersection. The property immediately west of this site was approved as a PD-R to allow the construction of 30+ single-family homes with a single access to Kanis Road. Other uses in the area further to the west include Baker Elementary School, a gun shop, apartment units and office uses. To the north of the site is a single-family subdivision, the Parkway Place Subdivision. To the southeast of the site is Chenal Pet Palace and vacant property currently being considered by the Commission for development of multi -family housing at a density of 20-units per acre. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received several informational phone calls from area residents. All property owners abutting the site along with the Capital Lakes Estates POA, the Kanis Creek POA, the Parkway Place POA, the Spring Valley Manor POA and the Woodlands Edge Community Association were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45-feet from centerline will be required. 2 October 30, 2014 SUBDIVISION ITEM NO.: FILE NO.: S-1735 2. With site development, provide the design of the street conforming to the Master Street Plan. Construct one-half street improvement to Kanis Road including 5-foot sidewalks with the planned development. The new back of curb should be 29.5-feet from centerline. Striping and transitions should be provided for a left turn lane. 3. With 41-lots, a variance from the Master Street Plan must be requested for the proposed street to be classified as a minor residential street. 4. Since the street is proposed to be 24-feet in width, show on the plan the area of street where parking will be restricted to one side. 5. The bulb in the center of the proposed street is ineffective for traffic calming as required by the Master Street Plan. Show on the plan the proposed means of traffic calming. Contact Nat Banihatti in Traffic Engineer at 501.379.1818 with any questions or for additional information. 6. The frontage along Kanis Road where the storm -drain is proposed should be platted as tract land. 7. A no access easement should be platted on the east side of Lot 19. 8. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is construction of the subdivision proposed to be phased? 9. Stormwater detention ordinance applies to this property. 10. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. 11. The lots on the south side of the street should be graded where the front yards of each lot and roof top drain to the street and the rear yards drain to the south. 12. Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 13. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering 501.379.1813, Greg Simmons, for more information. 14. Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley at 501.371.4537. 3 October 30, 2014 SUBDIVISION ITEM NO.: 2 Cont. FILE NO.: S-1735 15. Per Section 29-102 an evaluation should be conducted on the basis of existing downstream development and any analysis of stormwater runoff with and without the proposed development. If the proposed development will cause or increase downstream flooding conditions, provisions to minimize such flooding conditions should be included in the design of the storm management improvements. Such provisions may include downstream improvements and/or detention of stormwater runoff and its regulated discharge to the downstream storm drainage system. 16. Provide a letter prepared by a registered engineer certifying the sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 17. Show the existing driveways adjacent to this property on the west side of Kanis Road. 18. A driveway apron should be provided for the emergency access. The apron could be constructed of concrete or green pavers. Gravel is not allowed. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required, with easement, if sewer service is required for this project. The property must be annexed into the City limits of Little Rock to receive sewer service. Entergy: Entergy does not object to this proposal. A 3-phase power line is located on Kanis Road. A single phase, overhead power line is located on the rear lot lines of the subdivision to the north. Any service to this subdivision will need to be from the front lot line. Contact Entergy in advance to work out the electrical layout plan. Center -Point Ener4y: No comment received. AT & T: No comment received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas 0 October 30, 2014 SUBDIVISION ITEM NO.: 2 (Cont. LE NO.: S-1 Department of Health Engineering Division and the Little Rock Fire Department is required. 3. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 4. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 5. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). 6. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Fire Department: Turn -around as per Appendix D — 2012 AFC. Access Roads as per Appendix D with fire hydrant D 103.1-2. Hydrants as per 2012 AFAC Code. Contact the Little Rock Fire Department for additional information. County Planning: The property must be annexed into the City limits of the City of Little Rock prior to development. CATA: The area is not currently served by CATA at this location but it is on CATA's long range plans using Kanis Road. The development consists of single family homes. CATA requests consideration of ADA accessible sidewalks at this location and a pullout to enable buses to pull out of traffic to serve this location when improvements are made. Parks and Recreation: No comment received. F. ISSU ES/TECHN ICAL/DESI GN: Buildin Code: No comment. Planning Division: No comment. Landscape: No comment. �i October 30, 2014 SUBDIVISIO ITEM NO.: 2 (Cont. FILE NO.: S-1735 G. SUBDIVISION COMMITTEE COMMENT: (October 8, 2014) The applicant was present. Staff presented an overview of the item stating the request was for a preliminary plat for development of a single-family subdivision. Staff noted there were variances associated with the proposed preliminary plat. Staff stated a number of the lots were indicated with lot widths which were less than the 60-foot typically required within the R-2, Single-family zoning district. Staff requested the applicant provide tracts along Kanis Road which would then eliminated a number of variances associated with the two (2) lots such as double frontage lots, building lines and the need for restrictive access. Public Works comments were addressed. Staff questioned if advanced grading was requested to allow grading of the lots along with the installation of the infrastructure. Staff also questioned the treatment of the emergency access and if the access would be gated. Staff requested the applicant provide a letter prepared by a registered engineer certifying the sight distance at the street entrance to the subdivision. Staff stated streetlights would be required at the time of final platting. Staff noted the comments from the various other agencies. There were no more issues for discussion. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing a number of the issues raised at the October 8, 2014, Subdivision Committee meeting. The revised plat indicates the placement of a tract for Lots 1 and 41 along Kanis Road. The emergency access is indicated as a 25-foot all weather access drive. The plat indicates the emergency drive will be gated with a Knox box to allow fire department and emergency access only. The request is for preliminary plat approval to allow the creation of 41-lots from a 9.36-acre parcel. The preliminary plat as presented does create variances to allow lot widths less than the typical ordinance standard of 60-feet within the R-2, Single-family zoning district. Lots 10 — 34 are indicated with lot widths of 52 to 53-feet. All the lots are proposed to comply with the lot area of the R-2, Single-family Zoning District or 7,000 square feet. The minimum lot size proposed is 7,039 square feet (0.162-acres). The average lot size is 0.320 acres. The preliminary plat indicates 0.560-acres of common usable open space. There are three (3) tracts proposed for open space. The request also includes the allowance of 5-foot side yard setbacks for all the lots within the subdivision. October 30, 2014 SUBDIVISION ITEM NO.: 2 Cont. FILE NO.: S-1735 The development is proposed with a single street extending from Kanis Road and terminating in a hammer -head turn around. The preliminary plat indicates 1,410 linear feet of new street. The request includes a variance from the City's Master Street Plan. Per the Master Street Plan no more than 40-lots can be served by a minor residential street. The request includes a variance to allow the proposed development of 41-lots on a minor residential street. The site is located outside the City limits of Little Rock but abuts the City limits on the north and west sides. The applicant will be required to seek annexation into the City prior to the development to allow City sewer service. The request includes a variance from the City's Land Alteration Ordinance to allow grading of the lots with the installation of the street and the utilities. The applicant has indicated the grading is necessary to balance the site. The applicant has indicated efforts will be made to maintain as many trees as feasible on the site during the installation of the street and utilities. Staff is supportive of the request. Although there are variances associated with the request staff does not feel the variances will adversely impact this proposed development or the abutting property. Staff feels the development of this site with single-family homes at a density of 4.38-units per acre is appropriate for this site. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the comments and conditions as outlined in paragraphs D, E and F of the agenda staff report. Staff recommends approval of the variance request to allow reduced lot widths for Lots 10 — 34. Staff recommends approval of the variance request from the Master Street Plan to allow the proposed residential street to serve 41-lots. Staff recommends approval of the variance request to allow 5-foot side yard setbacks on all the proposed lots. Staff recommends approval of the variance request from the City's Land Alteration Ordinance to allow grading of the lots with the installation of the street and utilities. Staff recommends prior to grading activities on the site the applicant seek approval of annexation to the City of Little Rock. 7 October 30, 2014 SUBDIVISION ITEM NO.: 2 Cont. FILE NO.: S-1735 PLANNING COMMISSION ACTION: (OCTOBER 30, 2014) The applicant was present. There were no registered objectors present. Staff presented the item with a recommendation of approval of the request subject to compliance with the comments and conditions as outlined in paragraphs D, E and F of the agenda staff report. Staff presented a recommendation of approval of the variance request to allow reduced lot widths for Lots 10 — 34. Staff presented a recommendation of approval of the variance request from the Master Street Plan to allow the proposed residential street to serve 41-lots. Staff presented a recommendation of approval of the variance request to allow 5-foot side yard setbacks on all the proposed lots. Staff presented a recommendation of approval of the variance request from the City's Land Alteration Ordinance to allow grading of the lots with the installation of the street and utilities. Staff presented a recommendation prior to grading activities on the site the applicant seek approval of annexation to the City of Little Rock. There was no further discussion of the item. The Chair entertained a motion for approval of the item, as presented by staff. The motion carried by a vote of 11 ayes 0 noes and 0 absent. :3