Loading...
HomeMy WebLinkAboutS-1723 Map 4GRAVEL DRIVE i 2— 24" 1 4 ;TIIII[*.l 1. ALL WATER LINE CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF CENTRAL ARKANSAS WATER SPECIFICATIONS AND DETAILS, LATEST EDITION. E. MAINTAIN 10-FOOT OF HORIZONTAL AND 18-INCHES OF VERTICAL SEPARATION (WATER OVER SEWER) BETWEEN ALL WATER AND SEWER MAINS. 3. EACH PROPERTY OWNER WILL BE RESPONSIBLE FOR THE COSTS ASSOCIATED WITH THE INDIVIDUAL STEP SYSTEM, 4-INCH PVC GRAVITY SEWER SERVICE, AND 1i-INCH FORCE MAIN REQUIRED FOR THEIR LOT. THE DEVELOPER WILL INSTALL THE WWTP AND TRUNK PRESSURE SEWER COLLECTION SYSTEM REQUIRED FOR THE SUBDIVISION. THE DEVELOPER WILL INSTALL A 1i-INCH BALL VALVE ON THE TRUNK FORCE MAIN AT EACH PROPERTY. EACH INDIVIDUAL PROPERTY OWNER WILL CONNECT TO THE FORCE MAIN AT THE BALL VALVE, WHICH WILL SERVE AS THE X TRANSITION POINT BETWEEN THE DEVELOPER AND INDIVIDUAL PROPERTY OWNER'S CONSTRUCTION RESPONSIBILITIES. a_ I 0 X X XX X X- ---- X I a � X X X X X X x x � I I I PROPOSED FIRE HYDRANT 60 30 0 SCALE: 1"= 60' SCOTT & CHARLOTTE CARDOM ZONE RL m z 0 VI 120 LONGWOOD ROAD (ROW VARIES) I I I I I POND Q LOT 1 I 0.7398 Agree IL I I 349 9Feet 13 � LOT 2 I 0.738 Ames P I E YDRANT I 32140 Sq. Feet LOT 3 I I Acres ax I I I I II 0.798 I I II T P SITE 16'X8' TAPPING 3set LOT 4 EDETAIL DOUBLE SAME 0.7797 Acres LOT 5 SHEET 8 II LOT 7SLEEVE &VALVE WATER METER CTPJ rec 0787 �s LOT 89479q. Feat I I 0.800 Acres _ I I I 34873 Sq. Feet 0.708 Agree LOT 9 33475.9 Sq. Feet I I 0•751 Acres LOT 10 34029.2 Sq. Feet 1}' BALL VALVE I I I 738 q. Fe W/ CAP IN 24'0 LOT 6 I I 357se sq. Feet _ I RISER W/ LID F�2 I I 2 Sq et FUTURE FORCE MAIN 1000WATL MAIN 8' D.I I I CTYP. EACH LOT) I I I ASSEMBLY Y HYDRANT I IN RUN [I REDUCER U. I I �235 LF OF 3' VALVE NJ GATE I I — _ I Cu NOTE 2 I I PVC WATER MAIN � 8'W — — 8'W I PP-31W I SINGLE SAME SIDE / WATER METER CTYPa —� BLOWOFF HYDRANT I E LONG— $IDE WATER o I�ET (TYP.)I FORCE — a II 11T FUTUREM M2FMoEP PACKAGE I PROPERTY OWNER — �- 2•FMY FUTURE _ — P PERBTY OWNER EACH LOT) I WATER METER BLE <TYP.) I I < P. ACH LOT) II ! I0 r I 43o LF OF 2• a I I SDR-21 PVC o I 1}' BALL VALVE I FORCE MAIN 2' MJT WITH I SDR-21 PVC COMBINATION �I I W/ CAP IN 24 0 I 2 _ I FORCE MAIN AIR VALVE FUTURE FORCE MAIN I I VALVES I crYPa VE I I (TYP. EACH Lon I o I I I 103 Acres 20 I LOT 19 I LOT 18 I LOT 17 I LOT 16 48748 Sq. Feet I 0.965 Agrees I L O T 15 I I I 42048 3q. Feet I 76333 4 � 3t I 0.861 Agree I I LOT 14 LOT 13 37485 Sq. Feet 0.861 Acres P I I I I I 7I 7137405 9q. Feet I LOT 113485 S861 q. 94859q. Fat LOT 12 0.861 Acres I i q. Feet 0,845 Acres37485 SFt I I I 38809 Sq.Fed 0.927 Acres a I I I I I I I I I 40399 34. Feet i I I I I I I I I I► I I I I I I 0 PPI APPROXIMATE WATERLINE CO LOCATION F X x x A I - E 1 0 V o 7 eej ::-M i �<a N e- j 0 O E La a,o0_S V ti 00 v p a u. o C W •�+ R G a+ i m o, W C Ch Ln 0 W W o V) to N to t"n v = ON Z =� L to rrm^ m O V O c: � 1= o 0 c, Co U W J C/) I— w Q O H ILL W Z F- Q Q 0 W >_ a Q � � w � Q Q U) J U) CL s AR f REGISTERED WROFESSIONAL11 ",z- ENGINEERttIW; N0.9551 CONTENTS: WATER & SEWER PLAN PROJECT NO: 13042 DATE: MARCH 2O14 SHEET NO: 6