HomeMy WebLinkAboutS-1515 Map 2�I
T �N
o
a w
430
g
01 ,
W EXECU — x �'_ CERELLE DR
Bilf ST,
49 0
- w ' n
I W, 20TH ST
w 6ND ST- �'�,. m I
TANYA DR
-
s jW 24TH ST
05
SHEPHERD `CV
I I KENSINGT,OVDR - PROJECT $PEE o
m W 29TH ST
W 30THA ST
W 31STjST
��OU TMTH DR k -
L! 11NN
THIS PLAN IS FOR CONCEPT ONLY
AND IS NOT INTENDED FOR USE AS
A CONSTRUCTION DRAWING.
SHEPHERD'S COVE
4-STORY FRAME
200 100 0 200
DRIVE
OPTION B
/ MAINTENANCE BLDG
t 1-STORY METAL FRAME
PR. IND. LIVING FACILITY = -
o� DRIVE
OPTION A
A �A_jr_kl
r
MOORE BLDG --j
7-STORY BRICK
ROBERTS BLDG
2-STORY BRICK
RHINEHART BLE
4-STORY BRICK
w
0
r
it
a
OWNER:
ADDRESS:
PROPERTY USAGE:
ZONE CLASSIFICATION:
TOTAL DEVELOPED AREA:
GROSS FLOOR AREA:
BUILDING DATA:
BUILDING HEIGHT:
PARKING REQUIRED:
PARKING PROVIDED:
GOOD SHEPHERD ECUMENICAL CENTER
ATTN: TERRY HYPES
2701 ALDERSGATE ROAD
LITTLE ROCK, AR 72205
2701 ALDERSGATE RD
LITTLE ROCK, AR 72205
ECUMENICAL COMMUNITY
SEE ABOVE (MF-18 & MF-12)
a 5 ACRES
40,048 SQ. FT.
4 STORY BRICK/FRAME
54 FEET +/-
ELDERLY HOUSING 0.5 SPACES PER UNIT
194 BEDROOMS (0.5) = 97 SPACES REQUIRED
133 PARKING STALLS (INCLUDING 5 HC)
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL & ASSOCIATES, INC., AND IS NOT TO BE USED, IN
WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE
WRITTEN AUTHORIZATION OF CRAFTON, TULL &
ASSOCIATES, INC.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
W
LEGEND
EXISTING POWER POLE
PROPOSED MANHOLE
PROPOSED DRAINAGE INLET
PROPOSED FIRE HYDRANT ASSY.
PROPOSED WATER METER CLUSTER
PROPOSED SIDEWALK
PROPOSED BUILDING SETBACK
EXISTING CHAIN LINK OR WIRE FENCE
EXISTING UNDERGROUND ELECTRIC
EXISTING OVERHEAD ELECTRIC
EXISTING GAS LINE
EXISTING CONCRETE
PROPERTY LINE
SILT FENCE
EXISTING UTILITY EASEMENT
PROPOSED UTILITY EASEMENT
PROPOSED SANITARY SEWER LINE
EXISTING SANITARY SEWER LINE
PROPOSED SANITARY SEWER SERVICE
PROPOSED WATER LINE
EXISTING 6" WATER LINE
PROPOSED CURB & GUTTER
PROPOSED CONTOUR LINE
EXISTING CONTOUR LINE
EXISTING TREE CANOPY
NORMAL WATER ELEVATION
PROPOSED CENTER LINE
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPE
S OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
V r A UT '0
CRAFION, TULL & N
ASSOCIATES, INC. v
Na. 109 +,
� Ot
ggKAASAS ENGIHE�e,.".`
No.10432
is C. GOP,i 10
ti E fn
L
p
m
o N
`' >
•—,++ aI
V w L
O (nn
U) 7; CD
N m (0 U)
v
to
0 LO cD
I?CD
LO 06
NN ..
H �r-U_
C < NL
O C VM
U_ O d
rL00 �, ui
V ao ., CD
J CD
NOWLLI
�i
`Z
U
�
�
Q
W
Z
Q
=
Z¢
w
Z
1z
C-D
Z
_�
W
�
Z
Revisions
Drawn by
MAB
Checked b
-TLC_f
Date
2/20/06
SITE PLAN
Job Number
723-2
Contact Person
T. GRAHAM
Sheet Number
Cl '01