HomeMy WebLinkAboutS-1501-F Map 6NOTES
1. LEASE LINES ARE APPROXIMATE AND ARE SHOWN BASED ON TOPOGRAPHIC SURVEY TIE TO BOUNDARY
l MONUMENTATION. DIMENSIONS PER SURVEY BY GARVER ENGINEERS DATED SEPTEMBER 2013 (JOB NO.
■ \ 13011114). TOTAL LEASE AREA = 130.29 ACRES; PROJECT AREA —26 ACRES.
2. EXISTING HANDICAPPED PARKING FROM PREVIOUS PROJECTS MEETS CODE REQUIREMENTS. NO ADDITIONAL
PARKING INCLUDED IN THIS PROJECT.
1 3. EXISTING BUILDING AND UTILITY LOCATIONS ARE APPROXIMATE. EXISTING TOTAL BUILDING COVERAGE IS
APPROXIMATELY 831,000 SO FT . TOTAL PLANNED 14 BAY HANGAR EXPANSION IS 216,800 SO FT (214,000
SO FT GROUND COVERAGE HANGAR; 400 SO FT PUMP STATION BLDG AND 2400 SO FT MECHANICAL SUPPORT
■ \ BLDG).
4. SITE LIGHTING TO BE LOW LEVEL AND DIRECTIONAL /GRAPMCSCALE
I \ 5. PART OF EXISTING 7 FT CHAINLINK FENCE ON AIRPORT PERIMETER TO REMAIN. NEW SECURITY FENCE 75 — 2 75 1�O 390
■ o (AREA OF ATTAINMENT FOR LITTLE ROCK NATIONAL AIRPORT) SHALL BE 7 FT HIGH CHAINLINK TOPPED WITH (m I1
3 STRANDS BARBED WIRE. NEW PERIMETER FENCE (NORTH LINE) TO BE 7 FT HIGH CHAINLINK WITHOUT 1 inch = 150 ft
l BARBED WIRE. NEW ENTRANCE DRIVE FENCE TO BE ORNAMENTAL WROUGHT IRON/STEEL.
6. REFER TO SHEET SPR-2 FOR LANDSCAPING AREAS.
l 7. AN IRRIGATION SYSTEM SHALL BE PROVIDED FOR NEW LANDSCAPED AREAS. LEGEND
I 8. SEE SHEET SPR-2 FOR DETAILED INFORMATION ON THE PROPOSED 14 BAY HANGAR ADDITION INCLUDING HANDICAP PARKING
I PROPOSED UTILITIES, DRAINAGE AND DETENTION, FENCES, DRIVES, AND STRUCTURES. FIRE HYDRANT
Q ' W EXISTING POTABLE WATER
all SW EXISTING FIRE SUPPLY EXISTING SANITARY SEWER
W PROPOSED POTABLE WATER
l,l FW PROPOSED FIRE SUPPLY
l G NATURAL GAS
■
BUILDING
so PT BUFFER a a APPROXIMATE LEASE LINE
9 FT BUFFER LINE END 9 FT BUFFER LINE _ �pw
l (VARIANCE REQUEST) NEW PERIM VARIANCE BUFFER •R=R I - -
�� AT CHANGE IN � —
APPROXIMATE LEASE--`�� BOUNDARY FENCE DRECOON S02r3S87'4TD0"E 1186.56'
NON 84�
$" SANI763 iR 0 �(-- --�
G 6" NATURAL GAS TO aF m st 1•%' - - - _ __ _ _
gT _ G mum
Ki
rs w s•• w _ __ - ■ — — • — ——v ■ ■ t
EAST s1x sT. w Fr Row) � .— — OR --r- — m — . _�� � — . — — 'b'�•
RR ■
10' SAN?ARY SEWER - - -
Pe I uECNANICAL S87°39'18"E 708.41' "
■ I�
FS 04L
YARD CONTROLED IXIT660.15' _-_ S88°09'44"E 327.9T c� T— • ., --_ NORMALLY CLOSED ■ 9 APPROXIMATE■LEASE SON, Y � •' f� 388 T55+E 355,55' `` TEMPt[� —�,— —•—
- — - _ — OPEN 3:30PM WIM I
zo
NEW 4" GAS �PULL BOGY 60 FT BUFFER W
�p P MAN i PROPOSED COMCAST LINE ICI I �} SO FT BUFFER)//`
0 cl � I RI CABLE RELOCATION I i �TTT'I`j) _ LINE �■ ■ — - } '
ICI P�yoo�l - (u9DExcRaueo) 111999 I gl I �l a I
Q V■ M1 N2
0' 2' GAS TO BE I R
q 0�46 ABANDONEDM111 _ '
I P a 12' GAS TO BE - u 1p1 l O
N08°21'10"W al OA ABANDONED _ u■ ,(L 0)
109.72'i_ I I ��■I OSFO 9sq9�l9P9j �✓C6•�'moo.1 l °g ■�II� . I morl+. \v` TD ENTERGY
ELECTRICAL SERVICE
RELOCATION
RGY (UNDERGROUND)
I I IIIIIIIQI �11QI- IIIIIIIIIO
1 PULL 0%
NO7"W 'P/ \
170.13' ■I
�xQ i W
�
w�o
^ ,
M+ I yq I EI g t q¢¢`�pp ry EXISTING TO SERARY ETRANCE
VICENCENTER.
I R��o ■ P�2 .. I I.• q0% • PNEW ULL BOTERGY ✓ R y NO CONTROLLED ACCESSCON
NOR TROLED MIT
SET -
i G jam//
- -+� OPEN S:30P - -- _ T-"�' -u •P
Foc FOG Foc �— F — Foc roc I oc EAST IaTN V. (ctosEn) �SR' - T SE , S49°36'06"W
N01°54'52"W —Fa •F�Y�j .. _ 16" W eN�9 41.24'
a
POgsO O 40'- n lil i'. 1 i6" W
O f,/ N88°2326"V
N86°26'11"W y Rriao' Pp �;A / jI �I �I �' �I �' /j/[J'/y' �(/y�//`�C//,�\ E+ �
96.1T �}}{-�}}{y4 P¢- - . __ q'$' R I NEw ENTERGY ' / �" RxsOD• - 1� \ d`10 / • .(e9 " 21.19• bl F E '. III
I'IIIIIIIIIIIIIII
�� y��p 9�T Off/ 4 PULL BOX \I \ 9C p[\°11'03"V✓
o � �
N01°15'07"E
132.85' z11
I i I 90
P�2 �P.� P �8 F•a O '� l� � � \. G Z F, \�ta� E . ♦ / 5<\�G /
S� OF
!f P
000 " �, �7 C+ • QJ Z• pi +�vL
J' O FF\ Ob G P 826' CH RD
N516°645'68"E �\P .E gF ':� R�v? v' 0 G J�' \ FW i ®e"� ���sR=630.00'011
\ S�
� 1ti
�„J4Jpi. r 6
460
10'1&V
04ORD
RECEIVED1
OCT p 7 2013
BY:— ----
�=E2
C�
o
O
CfD
I i I.cn
E
IIIn
�
3
Q-4
_y
r�
w
E-1
v L
CD
T--- I
Q
r�0
Cl]
O
CD-1
OQI
A
a
PROJECT NO.
052H-0246-001
DATE 10-7-13
SHEET NO.