HomeMy WebLinkAboutPC Minutes for S-1992April 10, 2025
ITEM NO.: 7 FILE NO.: S-1992
NAME: Sardis Flats – Minor Subdivision Plat
LOCATION: 11700 Block of Sardis Road (east side)
DEVELOPER:
John McKissick
7625 Perry Lane
Mabelvale, AR 72103
OWNER/AUTHORIZED AGENT:
John McKissick – Owner
Stan Cunningham – Agent
SURVEYOR/ENGINEER:
Cunningham Surveying, LLC
2105 Lorance Drive
Little Rock, AR 72206
AREA: 0.69 acre NUMBER OF LOTS: 4 FT. NEW STREET: 0 LF
WARD: 7 PLANNING DISTRICT: 15 CENSUS TRACT: 41.04
CURRENT ZONING: R-2
VARIANCE/WAIVERS: None requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to subdivide 0.69 acre of property into four (4) lots for
single family residential development.
B. EXISTING CONDITIONS:
A one-story single family residence is located within the south portion of the
property, in the area of the proposed Lot 1. The remainder of the property is
undeveloped and wooded.
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property abutting the site and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS: (PLANNING)
1. Drive on lot 4 shall be an access easement as that is the only access to the
back lot.
ENGINEERING COMMENTS: (PUBLIC WORKS)
1. Sardis Road is classified on the Master Street Plan as a minor arterial. A
dedication of right-of-way 45 feet from centerline will be required.
2. An access and utility easement of at least 20 ft must be platted across proposed
lot 4 of sufficient width for the existing unimproved road and required utilities.
3. The Lot 4 easement will reduce the building area of proposed lot 4. If approved
access to proposed Lot 4 will be taken from the platted access and utility
easement.
4. With site development, provide design of street conforming to the Master Street
Plan. Construct one-half street improvement to Sardis Road including 5-foot
sidewalks with planned development. The new back of curb should be placed
29.5 ft from the centerline.
5. Driveway locations do not meet the traffic access and circulation requirements
of Sections 30-43 and 31-210. Due to the property located adjacent to Sardis
Road which is a minor arterial street on the Master Street Plan, driveway
spacing is 300 ft from streets and other driveways and 150 ft from side property
lines. The width of residential driveways must not exceed 20 feet and
constructed with a concrete apron to the property line.
6. Per Sec. 31-257, residential driveways for each lot accessing a minor arterial
street is not desirable, access to Sardis Road is prohibited and a 10 ft wide
restricted access easement should be platted adjacent to Sardis Road. For
conformance with Sec. 30-43 and 31-210, one (1) driveway within an access
easement or tract land should be constructed accessing the residential lots.
7. Per Sec. 31-256, a 35 ft front building setback is required adjacent to a minor
arterial street.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
3
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met.
Please submit plans for water facilities to Central Arkansas Water for review. Plan
revisions may be required after additional review. Contact Central Arkansas Water
regarding procedures for installation of water facilities. Approval of plans by
Central Arkansas Water, the Arkansas Department of Health Engineering Division
and Little Rock Fire Department is required.
If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
A Capital Investment Charge based on the size of meter connection(s) will apply
to this project in addition to normal charges.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
4
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply
with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval by the fire
code official.
8. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two-Family dwelling residential developments . Developments
of one- or two-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads,
and shall meet the requirements of Section D104.3.
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
5
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with
future development, as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2021 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Jason Lowder 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: : No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Code:
As per 2021 Arkansas Fire Prevention Code Volume III R302.1(1) Single Family
Dwellings have the following requirements when dealing with Dwellings that are
closer than 7’ from the property line:
1. If the soffit assembly extends inside of 5’ from the property line, it must be
constructed with fire -treated materials. 5/8” Type “X” Drywall, stucco, fire
treated plywood or some other fire treated material on underside of the soffit,
fire treated fascia, elimination of soffit vents and gable vents and crawl space
vents on the affected portion of the wall. Note: Vents must be relocated to
ensure proper venting of the attic space.
a. Exceptions to this are to fire block this section of the exterior wall from the
top plate to the underside of the roof decking and to fire caulk the blocking
at all joints.
2. As per 2021 Arkansas Fire Prevention Code Volume III R302.1(1) Single
Family Dwellings have the following requirements when dealing with Dwellings
that are closer than 5’ from the property line:
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
6
a. Exterior walls from 3 to 5’ from the property line must be constructed of
1-hour fire rated material and the soffit must be constructed from 1-hour
fire rated material. Soffit and gable vents are not allowed, and venting
must be relocated to adjacent roof and wall sections.
b. Fire Treated roof decking must extend 4’ up the roof as per the Authority
having jurisdiction.
c. In applications 3’ to 5’ from the dwelling unit to the property line exterior
windows are not allowed to exceed 25% of the wall area.
3. Zero Lot Line Construction must be processed through Zoning for such
allowances. Once processed the following requirements apply.
a. No part of the footing/foundation is allowed to extend beyond the
property line.
b. No overhang is allowed closer than 2’ from the property line and must
be constructed from 1-hour fire- treated materials.
c. Roof decking must have 4’ of fire treated material for the entire length of
the wall and turning 4’ along the adjacent wall with hip roof construction.
d. No windows or doors are allowed when the exterior wall is less than 3’
from the property line. Windows are required in all sleeping rooms.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the Geyer Springs West Planning District. The Land Use Plan
shows RL for the requested area. The Residential Low Density (RL) category
provides for single family homes at densities not to exceed 6 dwelling units per
acre. Such residential development is typically characterized by conventional
single family homes but may also include patio or garden homes and cluster
homes, provided that the density remains less than 6 units per acre. The
application is for a Minor Subdivision Plat.
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
7
Surrounding the application area on the east side of Sardis Road are single family
residences on large tracts of land in an area of Residential Low Density use. To
the west of the site, across Sardis Road, are single family residences on large
tracts of land in areas of Mixed Commercial Industrial (MCI) and Commercial (C)
uses.
This site is not located in an Overlay District.
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
8
Master Street Plan:
Sardis Rd is a Minor Arterial on the Master Street Plan. Minor Arterials are high
volume roads designed to provide the connections to and through an urban area.
Curb cuts should be minimized to allow for continuous traffic flow while still allowing
some access to adjoining property. Deceleration Lanes are required. Standard
Right-of-way (ROW) is 90 feet. Sidewalks are required on both sides. This street
may require dedication of right-of-way and may require street improvements.
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
9
Bicycle Plan:
Sardis Rd is on the Master Bike Plan as a Proposed Class 2 Bike Lane. Class 2
Bike Lanes provides a portion of the pavement for the sole use of bicycles.
Historic Preservation Plan:
This property is not located in a Historic District.
H. ANALYSIS:
The applicant proposes to subdivide 0.69 acre of property into four (4) lots for
single family residential development. The property is located on the east side of
Sardis Road, within the 11700 block. A one-story single family residence is located
within the south portion of the property, in the area of the proposed Lot 1. The
remainder of the property is undeveloped and wooded.
The approximate sizes for the four (4) proposed lots will be as follows:
Lot 1 – 60 feet by 119 feet (7,137.65 sq. ft.)
Lot 2 – 55 feet by 119 feet (6541.83 sq. ft.)
Lot 3 – 55 feet by 119 feet (6,540.87 sq. ft.)
Lot 4 – 54 feet by 119 feet (6,533.92 sq. ft.)
The property is being subdivided as per the minor subdivision requirements as
found in Section 31-142 of the City’s Subdivision Ordinance as follows:
“Sec. 31-142. - Minor subdivisions.
(a) The staff may authorize a combined preliminary and final review
procedure for minor subdivisions. All plats submitted as minor
subdivisions shall require review and approval by the planning
commission.
(b) In order to qualify as a minor subdivision, a proposed subdivision
must meet the following requirements:
(1) The proposed plat does not create more than four (4) lots,
tracts or parcels of land.
(2) The proposed plat is intended for residential or commercial
use only and is not more than five (5) acres in size.
April 10, 2025
ITEM NO.: 7 (Cont.) FILE NO.: S-1992
10
(3) The proposed plat does not involve dedication of public street
or access easement through rather than adjacent to the lot,
tract or parcel proposed for subdivision.
(c) Request for minor subdivision approval shall be made by the
owner of the land to the department of planning and
development. Subdivision requirements shall be the same as
those required for the final plat. The planning commission shall
review the plat at their next regularly scheduled monthly
meetings. If the final plat is in conformance with the objectives
and standards of this chapter and all required information is
contained thereon, the planning commission shall certify its
approval of the plat, making proper notation on the original
tracing of the plat, and permit the plat's recording in the office of
the circuit clerk.”
The site is located adjacent to Sardis Road which is a minor arterial roadway. The
driveway spacing requirement of Section 31-210 will not allow each of the
proposed lots to have a driveway from Sardis Road. As such, the applicant is
proposing a 20 foot wide access easement along the north property line of the
proposed Lot 4 and along the east property line of proposed Lots 2 thru 4, providing
rear access to the proposed lots.
Section 31-256 requires residential lots which front on a minor arterial roadway to
have front platted building lines of not less than 35 feet. The proposed plat
conforms with that requirement.
To staff’s knowledge, there are no outstanding issues associated with the
proposed minor subdivision plat. The applicant is requesting no variances. Staff
believes that the proposed plat is appropriate for the area.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested minor subdivision plat, subject to
compliance with the comments and conditions outlined in paragraphs D, E and F,
and the staff analysis, of the agenda staff report.
PLANNING COMMISSION ACTION: (APRIL 10, 2025)
The applicant was present. There were no persons registered in opposition. Staff
presented the item, and a recommendation of approval as outlined in the “staff analysis”
above. The item remained on the Consent Agenda for Approval. The vote was 9 ayes,
0 nays and 2 absent The application was approved.