HomeMy WebLinkAboutZ-10134 Staff Report 032625April 10, 2025
ITEM NO.: 9 FILE NO.: Z-10134
NAME: Baker Accessory Dwelling – Conditional Use Permit
LOCATION: 4424 Lee Avenue
DEVELOPER:
Sarah Baker(Owner)
4424 Lee Avenue
Little Rock, AR 72034
OWNER/AUTHORIZED AGENT:
Brooks Surveying, Inc.
20820Arch Street Pike
Little Rock, AR 72065
AREA: 0.16 acre NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 3 PLANNING DISTRICT: 4 CENSUS TRACT: 15.08
CURRENT ZONING: R-2
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting a conditional use permit to construct a new, one-story
accessory dwelling in the rear yard area of the property. The applicant notes that
the existing single-family residence, and the accessory dwelling will not be rented
or leased. The subject property is within the Hillcrest Design Overlay District.
B. EXISTING CONDITIONS:
The property contains an existing one-story, wood-frame single-family residence,
approximately 1,764 square feet in area and a one-story accessory building
located in the rear yard area of the property.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property within 300 feet of the site and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
April 10, 2025
ITEM NO.: 9 (Cont.) FILE NO.: Z-10134
2
D. ENGINEERING COMMENTS (PLANNING):
1. If Driveway is proposed, then it shall allow adequate room outside of the Right-
of-Way.
ENGINEERING COMMENTS (PUBLIC WORKS):
1. Vehicle on-street parking is prohibited on the east side of Ash St.
2. If a driveway is proposed to be constructed for the proposed structure, the
driveway must be of sufficient length to prevent vehicle parking within the
public right-of-way.
3. Parking is prohibited within the public alley.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
Entergy: No comments received.
Summit Utility: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of the request
for water must be met.
Fire Department:
1. Full Life Safety Inspection.
Parks and Recreation: No comments received.
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
As per 2021 Arkansas Fire Prevention Code Volume III R302.1(1) Single Family
Dwellings have the following requirements when dealing with Dwellings that are
closer than 7’ from the property line:
1. If the soffit assembly extends inside of 5’ from the property line, it must be
constructed with fire -treated materials. 5/8” Type “X” Drywall, stucco, fire
April 10, 2025
ITEM NO.: 9 (Cont.) FILE NO.: Z-10134
3
treated plywood or some other fire treated material on underside of the soffit,
fire treated fascia, elimination of soffit vents and gable vents and crawl space
vents on the affected portion of the wall. Note: Vents must be relocated to
ensure proper venting of the attic space.
a. Exceptions to this are to fire block this section of the exterior wall from the
top plate to the underside of the roof decking and to fire caulk the blocking
at all joints.
2. As per 2021 Arkansas Fire Prevention Code Volume III R302.1(1) Single
Family Dwellings have the following requirements when dealing with Dwellings
that are closer than 5’ from the property line:
a. Exterior walls from 3 to 5’ from the property line must be constructed of
1-hour fire rated material and the soffit must be constructed from 1-hour fire
rated material. Soffit and gable vents are not allowed, and venting must be
relocated to adjacent roof and wall sections.
b. Fire Treated roof decking must extend 4’ up the roof as per the Authority
having jurisdiction.
c. In applications 3’ to 5’ from the dwelling unit to the property line exterior
windows are not allowed to exceed 25% of the wall area.
3. Zero Lot Line Construction must be processed through Zoning for such
allowances. Once processed the following requirements apply.
a. No part of the footing/foundation is allowed to extend beyond the property
line.
b. No overhang is allowed closer than 2’ from the property line and must be
constructed from 1-hour fire- treated materials.
c. Roof decking must have 4’ of fire treated material for the entire length of the
wall and turning 4’ along the adjacent wall with hip roof construction.
d. No windows or doors are allowed when the exterior wall is less than 3’ from
the property line. Windows are required in all sleeping rooms.
Utilities: Utilities are permitted below grade on property but cannot enter where
dwellings are located less than 7’ from the property line. HVAC Units must be
located on dwelling unit property.
1’ setback shown – No overhand and fire wall construction required. No windows
or doors allowed.
4’ setback shown – Fire wall required. Overhand limited to 12”
Other requirements as listed above.
April 10, 2025
ITEM NO.: 9 (Cont.) FILE NO.: Z-10134
4
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the Heights/Hillcrest Planning District. The Land Use Plan shows
RL for the requested area. The Residential Low Density (RL) category provides
for single family homes at densities not to exceed 6 dwelling units per acre. Such
residential development is typically characterized by conventional single family
homes but may also include patio or garden homes and cluster homes, provided
that the density remains less than 6 units per acre. The application is for a CUP
for an Accessory Dwelling.
April 10, 2025
ITEM NO.: 9 (Cont.) FILE NO.: Z-10134
5
Surrounding the application area are single family homes and to the north is a faith
based institution.
The subject site is located in the Hillcrest Design Overlay District (Ord. 20223).
April 10, 2025
ITEM NO.: 9 (Cont.) FILE NO.: Z-10134
6
Master Street Plan:
Lee Ave is a Collector on the Master Street Plan. Collectors are designed to
connect traffic from Local Streets to Arterials or to activity centers, with the
secondary function of providing access to adjoining property. The standard Right
of way is 60’. Sidewalks are required on one side of Collectors. This street may
require dedication of right-of-way and may require street improvements.
April 10, 2025
ITEM NO.: 9 (Cont.) FILE NO.: Z-10134
7
Bicycle Plan:
Lee Ave is not shown on the Master Bike Plan with existing or proposed facilities
in this area.
Historic Preservation Plan:
This property is not located in a Historic District.
H. ANALYSIS:
The applicant is requesting a conditional use permit to construct a new, one-story
accessory dwelling in the rear yard area of the property. The applicant notes that
the existing single-family residence, and the accessory dwelling will not be rented
or leased. The subject property is within the Hillcrest Design Overlay District.
The property contains an existing one-story, wood-frame single-family residence,
approximately 1,764 square feet in area and a one-story accessory building
located in the rear yard area of the property.
The accessory dwelling will replace the existing accessory building in the rear yard
area of the property and align with the existing single-family dwelling on the property.
Entrance to the accessory dwelling is shown to be from a door (entrance stoop) on
the north side of the building, along the alley in the rear of the property.
The dimensions are shown as 16.0 feet x 31.0 feet (496 square feet) that includes a
244 square foot loft. The loft will be accessed by stairs that lead to the upper area of
the accessory dwelling. The total heated and cooled space will be 740 square feet in
area.
Section 36-502 requires one (1) parking space for accessory dwellings. The applicant
will build a new concrete driveway along Ash Street that will provide the off-street
parking space as required by code. The driveway must comply with ordinance
requirements.
Section 36-156(2)(c) requires an accessory building to be located no closer than
fifteen (15) feet from a street side property line. The site plan shows a twelve (12) foot
side yard setback from the west property line. Therefore, the applicant is requesting
a variance to reduce the side yard setback from fifteen (15) feet to twelve (12) feet,
along Ash Street. All remaining building setbacks, height, separation and rear yard
coverage comply with the code. Staff supports the variance request.
Staff is supportive of the requested conditional use permit to allow for the
construction of the accessory dwelling, as depicted on the site plan. Staff views
April 10, 2025
ITEM NO.: 9 (Cont.) FILE NO.: Z-10134
8
the request as reasonable. To staff’s knowledge, the proposed accessory dwelling
will not exceed the allowed rear yard coverage as required by the Hillcrest DOD
section of the code. Several properties in the general area contain a mixture of
residential zoning and uses that are denser than the proposed use of the subject
property. Staff feels that the proposed use will not be out of character with the
surrounding properties and should have no adverse impact on surrounding
properties in the area.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested conditional use permit subject to
compliance with the comments and conditions noted in paragraphs D, E, and
F, and the staff analysis, of the agenda staff report.