HomeMy WebLinkAboutS-1444 Staff AnalysisAugust 26, 2004
ITEM NO.: 5 FILE NO.: S-1444
NAME: McMurry Subdivision Preliminary Plat
LOCATION: Located on the Northwest corner of Vinson Road and Arch Street Pike
DEVELOPER:
McMurry
11200 Arch Street Pike
Little Rock, AR 72206
ENGINEER:
James S. Aunspaugh
510'h South Claremont Avenue
Sherwood, AR 72120
AREA: 2.03 acres
CURRENT ZONING:
PLANNING DISTRICT
CENSUS TRACT:
NUMBER OF LOTS: 2
Not zoned
14 — Geyer Springs West
40.01
FT. NEW STREET: 0
VARIAN C ESMAIVE RS REQUESTED: A five year deferral of street improvements to
Arch Street Pike and Vinson Road.
A. PROPOSAUREQUEST:
The applicant proposes the subdivision of 1.58 acres into two non-residential
lots. The site is located outside the City Limits but within the City's Extraterritorial
Planning Jurisdiction. The site is located within the planning area the City
exercises subdivision control only including the mater street plan requirements.
Proposed Lot 1 contains Arch Street Pharmacy and proposed Lot 2 will contain a
Dollar General Store. The applicant has meet with the Pulaski County Planning
Board and was approved at their August 3, 2004 Public Hearing.
The applicant has indicated Lot 1 will contain 0.92 acres and Lot 2 will contain
0.66 acres. The applicant has submitted an approval of the proposed
wastewater treatment system from the Pulaski County Sanitarian.
August 26, 2004
SUBDIVISION
ITEM NO.: 5 (Cont.) FILE NO.: S-
B. EXISTING CONDITIONS:
The site is vacant and cleared. There is a pharmacy located on proposed Lot 2
of the McMurry Subdivision. The Pharmacy has a continuous curb cut along
Arch Street Pike and Vinson Road. There are non-residential uses located along
Arch Street Pike in this area including the City of Little Rock Fire Training Center
and a Pulaski County Sheriff's sub -station.
Arch Street Pike is a two lane roadway with open ditches for drainage and no
sidewalk. Vinson Road is a narrow roadway also with open ditches for drainage
and no sidewalk.
C. NEIGHBORHOOD COMMENTS:
As of this writing staff has not received any comment from area residents. The
abutting property owners and Southwest Little Rock United for Progress were
notified of the Public Hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Arch Street Pike is classified on the Master Street Plan as a principal arterial.
Dedication of right-of-way 55-feet from centerline will be required (as shown
on the plat).
2. Vinson Road is classified on the Master Street Plan as a minor arterial. A
dedication of right-of-way 45-feet from centerline will be required (not shown
on the plat).
3. With the final platting, provide design of street conforming to the Master
Street Plan. Construct one-half street improvements including a 5-foot
sidewalk with the planned development. This would apply to all property
frontage shown on the plat.
4. Plans for all work in the right-of-way shall be submitted to Public Works for
approval prior to the start of construction. Obtain permits for work in the right-
of-way from AHTD, District 6.
5. For the Dollar Store Site Plan; Ordinance criteria requires commercial
driveways be spaced 150-feet from the property boundary and have a
maximum width of 36-feet. A cross access easement between the properties
with a shared driveway between the properties is suggested.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Outside the service boundary. No comment.
2
August 26, 2004
SUBDIVISION
ITEM NO.: 5 Cont. FILE NO.: S-1444
Entergy: No comment received.
Center -Point Energy: Approved as submitted.
SBC: Approved as submitted.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. Approval of the City of Little
Rock is also required prior to service. A Capital Investment Charge based on the
size of the meter connection(s) will apply to this project in addition to normal
charges. This fee will apply to all meter connections including any metered
connections off the private fire system. Additional fire hydrant(s) may be required.
Contact the Fire Department having jurisdiction to obtain information regarding
fire hydrant requirements and contact Central Arkansas Water regarding
procedures for installation of the hydrant(s).
Fire Department: Place fire hydrants per code. Contact the Little Rock Fire
Department at 918-3752 for additional information.
County Planning: The front building line should be set at 40-feet not the 25-feet
indicated. An engineering certification is required along with the stamp and
signature. Pulaski County supports the applicant's request for a deferral of street
improvements to Arch Street Pike and Vinson Road.
CATA: No comment received.
F. ISSUES/TECHN ICAUDESIGN:
Planning Division: No comment.
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (August 5, 2004)
Mr. James Aunspaugh was present representing the request. Staff presented an
overview of the proposed request indicating the request was located outside the
City Limits but within the City's Planning Jurisdiction. Staff requested the
applicant provide the entire plat area on the preliminary plat.
Public Works comments were addressed. Staff stated right-of-way dedication
and street construction to Arch Street Pike and Vinson Road would be required
per the Master Street Plan standard. Mr. Aunspaugh questioned if a waiver or
deferral could be sought. Staff stated typically on commercial site the Board
would not approve a waiver but would typically support a deferral.
Q
August 26, 2004
SUBDIVISION
ITEM NO.: 5 (Cont.
FILE NO.: S-1444
Staff stated they would recommend a shared driveway adjacent to the site. Staff
stated this would reduce the number of conflicting traffic movements to the site.
Mr. Aunspaugh stated the site had been designed to separate the truck traffic
accessing the Dollar General Store site and the customer traffic accessing the
Pharmacy site. Mr. Aunspaugh stated the pharmacy did not have a dedicated
drives just one continuous curb cut.
Staff suggested the applicant meet with this to discuss alternatives for driveway
design and location. Mr. Aunspaugh stated this was acceptable.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised plan to staff addressing most of the issues
raised at the August 5, 2004 Subdivision Committee meeting. The applicant has
indicated the entire plat area on the proposed preliminary plat as requested by
staff. The applicant has also indicated a dedication of right-of-way along Arch
Street Pike and Vinson Road per the Master Street Plan requirements. The
applicant is requesting a five year deferral of street construction to each of the
streets. Staff is supportive of this request.
The applicant has indicated Lot 1 will contain 0.92 acres and Lot 2 will contain
0.66 acres. Staff is supportive of the indicated lots sizes. The applicant has
submitted an approval of the proposed wastewater treatment system from the
Pulaski County Sanitarian.
The applicant has indicated the shared drive and cross access easement is not
conducive to the development of the site for the Dollar General Store. The
applicant has stated the existing pharmacy preferred the deliveries be taken on
the north side of the building to avoid noise and congestion. The dumpster was
also located on the northern side for the same reason. The perk test and septic
system were designed and approved based on the site plan as submitted. The
septic system is located on the south side of the building and the only area the
septic system could be located. In addition the existing pharmacy patrons
presently park in front of the pharmacy. They pull directly off Arch Street Pike.
Due to the location of the pharmacy and distance off of Arch Street Pike the
Dollar General Store is located there is potential for bottleneck and congestion on
the site. Staff supports the proposed driveway location.
To Staffs knowledge there are no outstanding issues associated with the
proposed request.
0
August 26, 2004
SUBDIVISION
ITEM NO.: 5 (Cont.) FILE NO.: S-1444
STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
conditions outlined in paragraphs D, E and F of the above report.
Staff recommends approval of the applicant's request for a five year deferral of
street improvements to Vinson Road and Arch Street Pike.
PLANNING COMMISSION ACTION: (AUGUST 26, 2004)
The applicant was present representing the request. There were no registered
objectors present. Staff presented a recommendation of approval of the request subject
to compliance with the conditions outlined in paragraphs D, E and F of the above report.
There was no further discussion of the item. The chair entertained a motion to place the
item for inclusion on the consent agenda for approval. The motion carried by a vote of
9 ayes, 0 noes and 2 absent.
Staff also presented a recommendation of approval of the applicant's request for a five
year deferral of street improvements to Vinson Road and Arch Street Pike.
There was no further discussion of the item. The chair entertained a motion to place the
item for inclusion on the consent agenda for approval. The motion carried by a vote of
9 ayes, 0 noes and 2 absent.
67
ITEM NO.: 5 FILE NO.: S-1444
NAME: McMurry Subdivision Preliminary Plat
LOCATION: located on the Northwest corner of Vinson Road and Arch Street Pike� �
Planning Staff Comments:
1. Provide notification of abutting property owners oo sine coMete with the
certified abstract list, notice form with affidavit executed and proof of mailing.
2. The applicant has provided an approval letter from the Pulaski County Sanitarian
concerning the proposed septic system.
3. Indicate the entire plat area on the proposed preliminary plat drawing.
Variance/Waivers: None requested. t�p�A
Public Works:
1. Arch Street Pike is classified on the Master Street Plan as a principal arterial.
Dedication of right-of-way 55-feet from centerline will be required (as shown on the
plat).
2. Vinson Road is classified on the Master Street Plan as a minor arterial. A dedication
of right-of-way 45-feet from centerline will be required (not shown on the plat).
3. With the final platting, provide design of street conforming to the Master Street Plan.
Construct one-half street improvements including a 5-foot sidewalk with the planned
development. This would apply to all property frontage shown on the plat.
4. Plans for all work in the right-of-way shall be submitted to Public Works for approval
prior to the start of construction. Obtain permits for work in the right-of-way from
AHTD, District 6.
5. For the Dollar Store Site Plan; Ordinance criteria requires commercial driveways be
spaced 150-feet from the property boundary and have a maximum width of 36-feet.
A cross access easement between the properties with a shared driveway between
the properties is suggested.
Utilities and Fire Department/County Planning:
Wastewater: Outside the service boundary. No comment.
Entergy: No comment received.
Center -Point Energy: Approved as submitted.
SBC: Approved as submitted.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. Approval of the City of Little Rock is also
required prior to service. A Capital Investment Charge based on the size of the meter
connection(s) will apply to this project in addition to normal charges. This fee will apply
to all meter connections including any metered connections off the private fire system.
Additional fire hydrant(s) may be required. Contact the Fire Department having
jurisdiction to obtain information regarding fire hydrant requirements and contact Central
Arkansas Water regarding procedures for installation of the hydrant(s).
Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department
at 918-3752 for additional information.
County Planning: The front building line should be set at 40-feet not the 25-feet
indicated. An engineering certification is required along with the stamp and signature.
CATA: No comment received.
Planning Division: No comment.
Landscape: No comment.
Revised plat/plan: Submit four (4) copies of a revised preliminary plan (to include the
additional information as noted above) to staff on Wednesday, August 11, 2004.